High-performance liquid chromatographic determination of vinorelbine in human plasma and blood: application to a pharmacokinetic study |
| |
Authors: | Amlie Gauvin Frdric Pinguet Sylvain Poujol Ccile Astre Franoise Bressolle |
| |
Institution: | Amélie Gauvin, Frédéric Pinguet, Sylvain Poujol, Cécile Astre,Françoise Bressolle, |
| |
Abstract: | A sensitive and specific high-performance liquid chromatographic method with fluorescence detection (excitation wavelength: 280 nm; emission wavelength: 360 nm) was developed and validated for the determination of vinorelbine in plasma and blood samples. The sample pretreatment procedure involved two liquid–liquid extraction steps. Vinblastine served as the internal standard. The system uses a Spherisorb cyano analytical column (250×4.6 mm I.D.) packed with 5 μm diameter particles as the stationary phase and a mobile phase of acetonitrile–80 mM ammonium acetate (50:50, v/v) adjusted to pH 2.5 with hydrochloric acid. The assay showed linearity from 1 to 100 ng/ml in plasma and from 2.5 to 100 ng/ml in blood. The limits of quantitation were 1 ng/ml and 2.5 ng/ml, respectively. Precision expressed as RSD was in the range 3.9 to 20% (limit of quantitation). Accuracy ranged from 92 to 120%. Extraction recoveries from plasma and blood averaged 101 and 75%, respectively. This method was used to follow the time course of the concentration of vinorelbine in human plasma and blood samples after a 10-min infusion period of 20 mg/m2 of this drug in patients with metastatic cancer. |
| |
Keywords: | Vinorelbine |
本文献已被 ScienceDirect 等数据库收录! |
|