首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
Xie R  Tu M  Wu Y  Adhikari S 《Bioresource technology》2011,102(7):4938-4942
5-Hydroxymethylfurfural (HMF) and furfural could be separated by the Aminex HPX-87H column chromatography, however, the separation and quantification of acetic acid and levulinic acid in biomass hydrolysate have been difficult with this method. In present study, the HPLC separation of acetic acid and levulinic acid on Aminex HPX-87H column has been investigated by varying column temperature, flow rate, and sulfuric acid content in the mobile phase.The column temperature was found critical in resolving acetic acid and levulinic acid. The resolution for two acids increased dramatically from 0.42 to 1.86 when the column temperature was lowered from 60 to 30 °C. So did the capacity factors for levulinic acid that was increased from 1.20 to 1.44 as the column temperature dropped. The optimum column temperature for the separation was found at 45 °C. Variation in flow rate and sulfuric acid concentration improved not as much as the column temperature did.  相似文献   

2.
A simple, rapid, specific and sensitive high-performance liquid chromatography method has been developed for quantitation of 5-fluorouracil (5-FU) in human plasma. The method involves deproteinization of a small sample volume of plasma (150 μl) followed by HPLC on a cation-exchange resin column, Aminex HPX-87H (300×7.8 mm I.D.), preceded by a similar guard cartridge with UV detection at 265 nm. This method allows a good separation of 5-FU with a retention time of 24 min and a detection limit at 25 ng/ml. The calibration curve was linear from 25 to 2000 ng/ml. The coefficient of variation was ≤4.4% for within-day reproducibility and ≤9.5% for day-to-day reproducibility.  相似文献   

3.
A new high performance liquid chromatographic (HPLC) method is described for the selective determination of small quantities of ketoses obtained by the action of immobilized isomerases on wheat bran hydrolysates, in the concentrated syrups of the corresponding glucose, arabinose, and xylose. This method uses MilliQ water instead of dilute sulfuric acid as a mobile phase on an Aminex HPX-87H column. Excellent discrimination between xylulose and ribulose was achieved. Selective detection of ketoses was made possible by the much higher UV absorbance at 210 nm. The sensitivity limit is 0.5 g/L for D-xylulose and L-ribulose. The response is linear up to a 20 g/L ketose concentration regardless of the presence of less than 50 g/L of D-xylose or L-arabinose.  相似文献   

4.
A high-performance liquid chromatographic (HPLC) method has been developed for identification and quantification of inositol isomers and monosaccharides in inositol-containing glycans. The method, which can determine 10 pmol of inositol, utilizes an Aminex HPX-87C column packed with an 8% crosslinked cation-exchange resin in the calcium form eluted with deionized water at 50 degrees C. NaOH solution is added to the column effluent through a postcolumn tee to increase the pH (pH greater than 11.6) before entering a pulsed amperometric detector which is highly sensitive for polyhydroxylated compounds. Samples in which inositol is linked to sugar through a glycosidic bond are hydrolyzed with 5.5 N trifluoroacetic acid, 100 degrees C, 4 h, and then reduced with NaBH4. Samples in which inositol is linked via a phosphate ester are hydrolyzed with 6 N HCl, 110 degrees C, 24 h. This method has been applied to the analysis of inositol in the hamster prion proteins (PrP) PrP27-30, and PrPSc.  相似文献   

5.
A new high-performance liquid chromatographic (HPLC) method is described for the determination of urinary N-acetyl-S-(N-methylcarbamoyl)cysteine (AMCC), the final product of the conjugation reaction between a metabolic intermediate of N,N-dimethylformamide (DMF) and glutathione. Urine samples were purified by C(18) solid-phase extraction and then directly analysed by HPLC with an Aminex Ion Exclusion HPX-87H column maintained at 25 degrees C and a UV detector set at 196 nm. Under isocratic conditions (2.4 mM sulphuric acid, flow-rate=0.6 ml/min) AMCC eluted at 20.2 min. The reproducibility (C.V.%) was 1.3-2.7% (intra- and inter-assay, N = 5); the accuracy was 98.0+/-1.7% at 10 mg/l and 101.9+/-1.5% at 800 mg/l (mean+/-SD, N = 3). AMCC was measured in urine from 22 exposed subjects. A strong correlation was found between AMCC and environmental DMF [AMCC (mg/g creatinine)=3.40xDMF (mg/m(3)) + 3.07; r=0.95], while in the urine of 20 unexposed subjects the concentration of AMCC was constantly below the detection limit of the method (0.9 mg/l in urine). The method described appears to be useful for the biological monitoring of DMF exposure.  相似文献   

6.
A reliable high-performance liquid chromatographic (HPLC) method which allows the determination in human urine of two important metabolites of N,N-dimethylformamide (DMF), namely N-methylformamide (MMF) and N-methyl-N-(hydroxymethyl)formamide (DMFOH), is reported. A single-step rapid purification of urine was performed on a C18 solid-phase extraction column and the eluate was injected directly on to the HPLC column. HPLC was carried out isocratically on Aminex Ion Exclusion HPX-87H column using 7.5 · 10−4 M sulphuric acid as the mobile phase with ultraviolet detection at 196 nm. The method is specific, accurate, precise and sufficiently sensitive to be applied to the biological monitoring of MMF and DMFOH in workers exposed to DMF.  相似文献   

7.
Two-dimensional high-performance liquid chromatography (HPLC) is increasingly used for the separation and identification of compounds in biological matrices. Conventional two-dimensional HPLC involves either heart-cutting or column-switching techniques. These techniques work well but are very time consuming when the analysis involves many compounds and requires more than a few minutes to completely elute from the column. We have modified the column-switching technique by utilizing two columns in series, an Aminex HPX-87H organic acid column followed by a 15-cm 5-μm C18 analytical column. Both columns are compatible with the isocratic pH 2.5 H2SO4 mobile phase employed in the organic acid profiling. The dual-column system affords better resolution of urinary organic acids than does either column separately. Reversing the column order does not dramatically affect the elution pattern (peak shape, peak height, and Rf values are approximately the same). The dualcolumn HPLC configuration works well as a rapid means of screening urinary carboxylic acids prior to subsequent definitive analyses of abnormal samples.  相似文献   

8.
Ion-exclusion high-pressure liquid chromatography (HPLC) was used to measure poly-beta-hydroxybutyrate (PHB) in Rhizobium japonicum bacteroids. The products in the acid digest of PHB-containing material were fractionated by HPLC on Aminex HPX-87H ion-exclusion resin for organic acid analysis. Crotonic acid formed from PHB during acid digestion was detected by its intense absorbance at 210 nm. The Aminex-HPLC method provides a rapid and simple chromatographic technique for routine analysis of organic acids. Results of PHB analysis by Aminex-HPLC were confirmed by gas chromatography and spectrophotometric analysis.  相似文献   

9.
A high-performance liquid chromatographic (HPLC) procedure has been developed for the separation of phospholipids commonly found in amniotic fluid. The chromatographic separation was achieved on a 25-cm column packed with LiChrosorb DIOL (10 μm). A 3-cm column packed with silica was fitted between the injector and the DIOL column to provide complete separation of lecithin (L) and sphingomyelin (S) from the remaining amniotic fluid phospholipids. The eluted phospholipids were quantitated employing an ultraviolet absorption detector set at 203 nm. The new HPLC separation described herein has improved the resolution and peak sharpness of L and S. Furthermore, phosphatidyl glycerol and phosphatidyl inositol were completely separated and quantitated. Amniotic fluid L/S ratios determined by this technique have been compared to those of an established thin-layer chromatographic procedure.  相似文献   

10.
Ion-exclusion high-pressure liquid chromatography (HPLC) was used to measure poly-β-hydroxybutyrate (PHB) in Rhizobium japonicum bacteroids. The products in the acid digest of PHB-containing material were fractionated by HPLC on Aminex HPX-87H ion-exclusion resin for organic acid analysis. Crotonic acid formed from PHB during acid digestion was detected by its intense absorbance at 210 nm. The Aminex-HPLC method provides a rapid and simple chromatographic technique for routine analysis of organic acids. Results of PHB analysis by Aminex-HPLC were confirmed by gas chromatography and spectrophotometric analysis.  相似文献   

11.
The development of tolerant microorganisms is needed for the efficient fermentation of inhibitory lignocellulose hydrolysates. In the current work, the fermentation performance of six selected strains of Saccharomyces cerevisiae in dilute-acid spruce hydrolysate was compared using two different modes of fermentation; either single pulse addition of hydrolysate to exponentially growing cells or continuous feeding of the same amount of hydrolysate in a controlled fed-batch fermentation was made. All strains performed better in fed-batch mode than when all hydrolysate was added at once. However, the difference between strain performances varied significantly in the two fermentation modes. Large differences were observed between strains during the fed-batch experiments in the in vitro ability to reduce the furan compounds furfural and 5-hydroxymethyl furfural (HMF). A common feature among the strains was the induction of NADPH-coupled reduction of furfural and HMF, with the exception of strain CBS 8066. This strain also performed relatively poorly in both batch and fed-batch fermentations. Strain TMB3000--previously isolated from spent sulphite liquor fermentation--was by far the most efficient strain with respect to specific fermentation rate in both pulse addition and fed-batch mode. This strain was the only strain showing a significant constitutive NADH-coupled in vitro reduction of HMF. The ability to induce NADPH-coupled reduction together with the level of the apparently constitutive NADH-coupled reduction appeared to be key factors for selecting a suitable strain for fed-batch conversion of lignocellulose hydrolysate.  相似文献   

12.
A rapid isocaratic high-performance liquid chromatography (HPLC) method for quantitation of serum N-acetylneuraminic acid (NANA) is described. Separation is achieved on an Aminex HPX-87 cation-exchange resin using a 0.006 N sulfuric acid mobile phase. Compared with the more conventional thiobarbituric acid (TBA) method, HPLC is more reliable and has a much improved maximum sensitivity of 0.8 nmol/ml. In a limited study of malignant melanoma patients' sera, HPLC gave slightly higher values for NANA than TBA. In a more detailed study of breast carcinoma patients with measurable tumour burden, HPLC and TBA methods were used on the same sera and compared with concurrent carcinoembryonic antigen (CEA) determinations. HPLC resulted in a clear improvement in discrimination between tumour burden groups compared with either the TBA method or CEA.  相似文献   

13.
This study investigated the detoxification of a dilute acid pretreated Ponderosa pine slurry using the polyelectrolyte polyethyleneimine (PEI). The addition of polyelectrolyte to remove enzymatic and/or fermentation inhibitory compounds, that is, acetic acid, furfural, and 5-hydroxymethylfurfural (HMF), was performed either before or after enzymatic hydrolysis to determine the optimal process sequence. Negligible acetic acid, glucose, and xylose were removed regardless of where in the process the polymer addition was made. Maximum furfural and HMF separation was achieved with the addition of PEI to a clarified pre-enzymatic hydrolysis liquor, which showed that 88.3% of furfural and 66.4% of HMF could be removed. On the other hand, only 23.1% and 13.4% of furfural and HMF, respectively, were removed from a post-enzymatic hydrolysis sample; thus, the effects of enzymes, glucose, and wood solids on inhibitor removal were also investigated. The presence of solid particles >0.2 μm and unknown soluble components <10 kDa reduced inhibitory compound removal, but the presence of elevated glucose levels and enzymes (cellulases) did not affect the separation. The fermentability of detoxified versus undetoxified hydrolysate was also investigated. An ethanol yield of 92.6% of theoretical was achieved with Saccharomyces cerevisiae fermenting the detoxified hydrolyzate, while no significant ethanol was produced in the undetoxified hydrolyzate. These results indicate that PEI may provide a practical alternative for furan removal and detoxification of lignocellolosic hydrolysates, and that application before enzymatic hydrolysis minimizes separation interferences.  相似文献   

14.
Evidence is provided to show that in the conventional phenol-sulfuric acid reaction procedure, phenol underwent sulfonation in situ and the phenolsulfonic acid formed decreased the color intensity for hydroxymethyl furfural (HMF), furfural, and many hexoses and pentoses tested. A modified method is described to overcome this problem in which phenol was added after the dehydration of carbohydrates by sulfuric acid and after cooling the system. The color intensity around 475-485 nm for different compounds was fairly proportional to the amount of furfural derivatives (absorption at 310-320 nm) formed from the sugars in the modified method unlike in the conventional procedure. The studies also show that for condensation of HMF derivatives with phenol, heat is not necessary. The color intensity in the modified method also increased compared to that in the conventional method. The increase in the modified method compared to that in the conventional method was 6.0-fold for furfural, 9.1-fold for hydroxymethyl furfural, 3.7-fold for fructose, 2.3-fold for xylose, and 2.0-fold for glucose and arabinose. The possible reasons for this differential increase are discussed.  相似文献   

15.
Fermentation to ethanol of pentose-containing spent sulphite liquor   总被引:3,自引:0,他引:3  
Ethanolic fermentation of spent sulphite liquor with ordinary bakers' yeast is incomplete because this yeast cannot ferment the pentose sugars in the liquor. This results in poor alcohol yields, and a residual effluent problem By using the yeast Candida shehatae (R) for fermentation of the spent sulphite liquor from a large Canadian alcohol-producing sulphite pulp and paper mill, pentoses as well as hexoses were fermented nearly completely, alcohol yields were raised by 33%, and sugar removal increased by 46%. Inhibitors were removed prior to fermentation by steam stripping. Major benefits were obtained by careful recycling of this yeast, which was shown to be tolerant both of high sugar concentrations and high alcohol concentrations. When sugar concentrations over 250 g/L (glucose: xylose 70:30) were fermented, ethanol became an inhibitor when its concentration reached 90 g/L. However, when the ethanol was removed by low-temperature vacuum distillation, fermentation continued and resulted in a yield of 0.50 g ethanol/g sugar consumed. Further improvement was achieved by combining enzyme saccharification of sugar oligomers with fermentation. This yeast is able to ferment both hexoses and pentoses simultaneously, efficiently, and rapidly. Present indications are that it is well suited to industrial operations wherever hexoses and pentoses are both to be fermented to ethanol, for example, in wood hydrolysates.  相似文献   

16.
An ion-pairing high-performance liquid chromatographic method for the determination of N-acetylaspartate and N-acetylglutamate using a C-18 column and a UV detection at 210 nm wavelength, by means of a diode array detector, is presented. A buffer containing 2.8 mM tetrabutylammonium hydroxide, 25 mM KH(2)PO(4), 1.25% methanol, pH 7. 00, is utilized for the isocratic separation of these N-acetylated amino acids, at a flow rate of 1 ml/min and a column temperature of 23 degrees C. The suitability of this chromatographic separation (without additional chromatographic steps prior to HPLC assay) to monitor variations both of N-acetylaspartate and of N-acetylglutamate in perchloric acid brain extracts from rats subjected to the impact acceleration model of diffuse brain injury is also reported. According to the data presented, this HPLC method allows the separation of the two N-acetylated amino acids considered from the many possible interfering compounds, commonly present in extracts of cerebral tissue, which have high extinction coefficients at 210 nm wavelength. Values of N-acetylaspartate and N-acetylglutamate determined by this method showed that cerebral trauma negatively affects both compounds, according to the severity of trauma itself.  相似文献   

17.
A fast method is described for the screening of eleven β-blockers, two narcotic analgesics and two stimulants in urine by HPLC with column switching. The urine sample (100 μl), buffered tto pH 9–9.5, is injected onto a short extraction column packed with CN stationary phase. The extraction is flushed with water for 2.5 min to elute polar matrix components to waste. The retained components are then backflushed by means of a six-port valve onto the ODS analytical column where they are separated. Phosphate buffer pH 3.0 and acetonitrile were used as mobile phase. Gradient elution was applied in the screening method to improve separation. Detection was performed with diode-array detector at 220, 235 and 300 nm. Recoveries were near 100%, precision was excellent and sensitivity about 0.25 μg/1. The speed up the quantitative analysis, the same method but with isocratic elution was successfully applied to the determination of acebutolol and metoprolol in urine samples collected 4 h after administration of the compounds as single doses.  相似文献   

18.
SCH 66336 is a novel non-cytotoxic anti-tumor agent that is in phase I/II clinical trials for the treatment of solid tumors. This compound is a single enantiomer with one chiral center. Prior to evaluation of this drug candidate in man, it was necessary to evaluate its pharmacokinetics and possible chiral inversion in animals. Thus, high-performance liquid chromatographic (HPLC) methods have been developed for its determination in cynomolgus monkey plasma and for the evaluation of its chiral inversion in rats and cynomolgus monkeys. The achiral HPLC analysis involved extraction with 30% methylene chloride in hexane followed by separation on a CN column and quantitation by UV absorbance at 280 nm. The method was linear over a concentration range of 0.1 to 20 μg/ml in monkey plasma. The chiral HPLC analysis involved the use of a Chiralpak AD column set at 39°C with a mobile phase of hexane–ethanol–diethylamine mixture and a UV detector set at 280 nm. Plasma samples were subjected to solid-phase extraction on a C2 cartridge prior to HPLC analysis. The method was linear over a concentration range of 0.25 to 10 μg/ml in rat and cynomolgus monkey plasma for both enantiomers. Both methods showed good linearity (r2>0.99), accuracy (bias<13%) and precision (CV<12%). Chiral HPLC analysis indicated that SCH 66336 was not subjected to chiral inversion in rats and cynomolgus monkeys  相似文献   

19.
目的:用RP-HPLC方法对注射用重组人尿激酶原制剂蛋白含量进行定量分析。方法:用反相C18柱、0.1%TFA水溶液与0.1%乙腈进行梯度洗脱,280nm波长紫外检测器监测;以重组人尿激酶原同质标准品作为对照品,根据进样量和相应的峰面积建立标准曲线方程,将待测定样品的峰面积代入标准曲线方程,可测得蛋白含量。结果:按照方法学验证要求对此方法进行了专属性、检测限、定量限、线形、精密度(重复性、中间精密度)、准确度(回收率)考察,线性范围为9~27μg,回收率在97%以上,RSD2.0%,完全满足对制剂蛋白的定量需求。结论:本方法准确,适用于注射用重组人尿激酶原成品制剂蛋白定量测定。  相似文献   

20.
A rapid and simple high-performance liquid chromatographic (HPLC) method has been developed and validated for determination of scopoletin in rat plasma using psoralen as internal standard. Chromatographic separation was achieved on a C(18) column using methanol and distilled water (49:51, v/v) containing 0.05% (v/v) phosphoric acid as mobile phase. The UV detector was set at 345 nm. The calibration curve was linear over the range of 0.165-9.90 microg/ml with a correlation coefficient of 0.9994. The recovery for plasma samples of 0.165, 1.32 and 6.60 microg/ml was 93.2%, 95.9% and 95.5%, respectively. The RSD of intra- and inter-day assay variations was less than 6.7%. This HPLC assay is a precise and reliable method for the analysis of scopoletin in pharmacokinetic studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号