首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Background

Hyperpolarised helium MRI (He3 MRI) is a new technique that enables imaging of the air distribution within the lungs. This allows accurate determination of the ventilation distribution in vivo. The technique has the disadvantages of requiring an expensive helium isotope, complex apparatus and moving the patient to a compatible MRI scanner. Electrical impedance tomography (EIT) a non-invasive bedside technique that allows constant monitoring of lung impedance, which is dependent on changes in air space capacity in the lung. We have used He3MRI measurements of ventilation distribution as the gold standard for assessment of EIT.

Methods

Seven rats were ventilated in supine, prone, left and right lateral position with 70% helium/30% oxygen for EIT measurements and pure helium for He3 MRI. The same ventilator and settings were used for both measurements. Image dimensions, geometric centre and global in homogeneity index were calculated.

Results

EIT images were smaller and of lower resolution and contained less anatomical detail than those from He3 MRI. However, both methods could measure positional induced changes in lung ventilation, as assessed by the geometric centre. The global in homogeneity index were comparable between the techniques.

Conclusion

EIT is a suitable technique for monitoring ventilation distribution and inhomgeneity as assessed by comparison with He3 MRI.  相似文献   

2.
ABSTRACT: The measurement of ventilation distribution is currently performed using inhaled tracer gases for multiple breath inhalation studies or imaging techniques to quantify spatial gas distribution. Most tracer gases used for these studies have properties different from that of air. The effect of gas density on regional ventilation distribution has not been studied. This study aimed to measure the effect of gas density on regional ventilation distribution. METHODS: Ventilation distribution was measured in seven rats using electrical impedance tomography (EIT) in supine, prone, left and right lateral positions while being mechanically ventilated with either air, heliox (30% oxygen, 70% helium) or sulfur hexafluoride (20% SF6, 20% oxygen, 60% air). The effect of gas density on regional ventilation distribution was assessed. RESULTS: Gas density did not impact on regional ventilation distribution. The non-dependent lung was better ventilated in all four body positions. Gas density had no further impact on regional filling characteristics. The filling characteristics followed an anatomical pattern with the anterior and left lung showing a greater impedance change during the initial phase of the inspiration. CONCLUSION: It was shown that gas density did not impact on convection dependent ventilation distribution in rats measured with EIT.  相似文献   

3.

Background

Vibration response imaging (VRI) is a bedside technology to monitor ventilation by detecting lung sound vibrations. It is currently unknown whether VRI is able to accurately monitor the local distribution of ventilation within the lungs. We therefore compared VRI to electrical impedance tomography (EIT), an established technique used for the assessment of regional ventilation.

Methodology/Principal Findings

Simultaneous EIT and VRI measurements were performed in the healthy and injured lungs (ALI; induced by saline lavage) at different PEEP levels (0, 5, 10, 15 mbar) in nine piglets. Vibration energy amplitude (VEA) by VRI, and amplitudes of relative impedance changes (rel.ΔZ) by EIT, were evaluated in seven regions of interest (ROIs). To assess the distribution of tidal volume (VT) by VRI and EIT, absolute values were normalized to the VT obtained by simultaneous spirometry measurements. Redistribution of ventilation by ALI and PEEP was detected by VRI and EIT. The linear correlation between pooled VT by VEA and rel.ΔZ was R2 = 0.96. Bland-Altman analysis showed a bias of −1.07±24.71 ml and limits of agreement of −49.05 to +47.36 ml. Within the different ROIs, correlations of VT-distribution by EIT and VRI ranged between R2 values of 0.29 and 0.96. ALI and PEEP did not alter the agreement of VT between VRI and EIT.

Conclusions/Significance

Measurements of regional ventilation distribution by VRI are comparable to those obtained by EIT.  相似文献   

4.
The aim of the study was to validate the ability of electrical impedance tomography (EIT) to detect local changes in air content, resulting from modified ventilator settings, by comparing EIT findings with electron beam computed tomography (EBCT) scans obtained under identical steady-state conditions. The experiments were carried out on six anesthetized supine pigs ventilated with five tidal volumes (VT) at three positive end-expiratory pressure (PEEP) levels. The lung air content changes were determined both by EIT (Goe-MF1 system) and EBCT (Imatron C-150XP scanner) in six regions of interest, located in the ventral, middle, and dorsal areas of each lung, with respect to the reference air content at the lowest VT and PEEP, as a change in either local electrical impedance or lung tissue density. An increase in local air content with VT and PEEP was identified by both methods at all regions studied. A good correlation between the changes in lung air content determined by EIT and EBCT was revealed. Mean correlation coefficients in the ventral, middle, and dorsal regions were 0.81, 0.87, and 0.93, respectively. The study confirms that EIT is a suitable, noninvasive method for detecting regional changes in air content and monitoring local effects of artificial ventilation.  相似文献   

5.
The assessment of the regional match between alveolar ventilation and perfusion in critically ill patients requires simultaneous measurements of both parameters. Ideally, assessment of lung perfusion should be performed in real-time with an imaging technology that provides, through fast acquisition of sequential images, information about the regional dynamics or regional kinetics of an appropriate tracer. We present a novel electrical impedance tomography (EIT)-based method that quantitatively estimates regional lung perfusion based on first-pass kinetics of a bolus of hypertonic saline contrast. Pulmonary blood flow was measured in six piglets during control and unilateral or bilateral lung collapse conditions. The first-pass kinetics method showed good agreement with the estimates obtained by single-photon-emission computerized tomography (SPECT). The mean difference (SPECT minus EIT) between fractional blood flow to lung areas suffering atelectasis was -0.6%, with a SD of 2.9%. This method outperformed the estimates of lung perfusion based on impedance pulsatility. In conclusion, we describe a novel method based on EIT for estimating regional lung perfusion at the bedside. In both healthy and injured lung conditions, the distribution of pulmonary blood flow as assessed by EIT agreed well with the one obtained by SPECT. The method proposed in this study has the potential to contribute to a better understanding of the behavior of regional perfusion under different lung and therapeutic conditions.  相似文献   

6.
Adler, A., R. Amyot, R. Guardo, J. H. T. Bates, and Y. Berthiaume. Monitoring changes in lung air and liquid volumes withelectrical impedance tomography. J. Appl.Physiol. 83(5): 1762-1767, 1997.Electricalimpedance tomography (EIT) uses electrical measurements at electrodesplaced around the thorax to image changes in the conductivitydistribution within the thorax. This technique is well suited tostudying pulmonary function because the movement of air, blood, andextravascular fluid induces significant conductivity changes within thethorax. We conducted three experimental protocols in a total of 19 dogsto assess the accuracy with which EIT can quantify changes in thevolumes of both gas and fluid in the lungs. In the first protocol, lungvolume increments from 50 to 1,000 ml were applied with a largesyringe. EIT measured these volume changes with an average error of 27 ± 6 ml. In the second protocol, EIT measurements were made at endexpiration and end inspiration during regular ventilation with tidalvolume ranging from 100 to 1,000 ml. The average error in the EITestimates of tidal volume was 90 ± 43 ml. In the third protocol,lung liquid volume was measured by instilling 5% albumin solution intoa lung lobe in increments ranging from 10 to 100 ml. EIT measured thesevolume changes with an average error of 10 ± 10 ml and was alsoable to detect into which lobe the fluid had been instilled. These results indicate that EIT can noninvasively measure changes in thevolumes of both gas and fluid in the lungs with clinically usefulaccuracy.

  相似文献   

7.

Introduction

Electrical impedance tomography (EIT) is an emerging clinical tool for monitoring ventilation distribution in mechanically ventilated patients, for which many image reconstruction algorithms have been suggested. We propose an experimental framework to assess such algorithms with respect to their ability to correctly represent well-defined physiological changes. We defined a set of clinically relevant ventilation conditions and induced them experimentally in 8 pigs by controlling three ventilator settings (tidal volume, positive end-expiratory pressure and the fraction of inspired oxygen). In this way, large and discrete shifts in global and regional lung air content were elicited.

Methods

We use the framework to compare twelve 2D EIT reconstruction algorithms, including backprojection (the original and still most frequently used algorithm), GREIT (a more recent consensus algorithm for lung imaging), truncated singular value decomposition (TSVD), several variants of the one-step Gauss-Newton approach and two iterative algorithms. We consider the effects of using a 3D finite element model, assuming non-uniform background conductivity, noise modeling, reconstructing for electrode movement, total variation (TV) reconstruction, robust error norms, smoothing priors, and using difference vs. normalized difference data.

Results and Conclusions

Our results indicate that, while variation in appearance of images reconstructed from the same data is not negligible, clinically relevant parameters do not vary considerably among the advanced algorithms. Among the analysed algorithms, several advanced algorithms perform well, while some others are significantly worse. Given its vintage and ad-hoc formulation backprojection works surprisingly well, supporting the validity of previous studies in lung EIT.  相似文献   

8.

Background and objectives

We investigated the effect of different breathing aids on ventilation distribution in healthy adults and subjects with cystic fibrosis (CF).

Methods

In 11 healthy adults and 9 adults with CF electrical impedance tomography measurements were performed during spontaneous breathing, continuous positive airway pressure (CPAP) and positive expiratory pressure (PEP) therapy randomly applied in upright and lateral position. Spatial and temporal ventilation distribution was assessed.

Results

The proportion of ventilation directed to the dependent lung significantly increased in lateral position compared to upright in healthy and CF. This effect was enhanced with CPAP but neutralised with PEP, whereas the effect of PEP was larger in the healthy group. Temporal ventilation distribution showed exactly the opposite with homogenisation during CPAP and increased inhomogeneity with PEP.

Conclusions

PEP shows distinct differences to CPAP with respect to its impact on ventilation distribution in healthy adults and CF subjects EIT might be used to individualise respiratory physiotherapy.  相似文献   

9.
Inhalation of hyperpolarized (3)He allows magnetic resonance imaging (MRI) of ventilated airspaces. (3)He hyperpolarization decays more rapidly when interacting with paramagnetic O(2). We describe a method for in vivo determination of intrapulmonary O(2) concentrations ([O(2)]) based on MRI analysis of the fate of measured amounts of inhaled hyperpolarized (3)He in imaged regions of the lung. Anesthetized pigs underwent controlled normoventilation in a 1.5-T MRI unit. The inspired O(2) fraction was varied to achieve different end-tidal [O(2)] fractions (FET(O(2))). With the use of a specifically designed applicator, (3)He (100 ml, 35-45% polarized) was administered at a predefined time within single tidal volumes. During subsequent inspiratory apnea, serial two-dimensional images of airways and lungs were acquired. At least once in each animal studied, the radio-frequency excitation used for imaging was doubled at constant FET(O(2)). Signal intensity measurements in regions of interest of the animals' lungs (volume range, 54-294 cm(3)), taken at two different radio-frequency excitations, permitted calculation of [O(2)] in these regions of interest. The [O(2)] fractions in the regions of interest correlated closely with FET(O(2)) (R = 0.879; P < 0.0001). O(2)-sensitive (3)He-MRI may allow noninvasive study of regional distribution of ventilation and alveolar PO(2) in the lung.  相似文献   

10.
目的 对肺通气过程进行床旁实时连续图像监控,是机械通气患者和临床医生的迫切需求。肺部电阻抗成像(EIT)可反映呼吸引起的胸腔电特性变化分布,在肺通气监测方面具有天然的优势。本文目的在于建立基于径向基函数神经网络(RBFNN)的肺部加权频差电阻抗成像(wfd-EIT)方法,实现对肺通气的高空间分辨率成像。方法 利用肺部wfd-EIT成像方法实时描绘胸腔电导率分布状况,再通过RBFNN将目标区域可视化并精准识别其边界信息。首先通过数值分析模拟,在各个激励频率利用COMSOL与MATLAB软件建立2 028个仿真样本,分为训练样本集和测试样本集,验证所提出成像方法的可行性和有效性。其次,为了验证仿真结果,建立肺部物理模型,选用具有低电导特性的生物组织模拟肺部通气区域,对其进行成像实验,并采用图像相关系数(ICC)和肺区域比(LRR)定量数据衡量成像方法的准确性。结果 wfd-EIT方法可以在任意时刻进行图像重建,并能够准确反映出目标区域的电特性分布;利用基于RBFNN的算法能够增强目标区域的成像精度,ICC可达0.94以上,更好地凸显其边界轮廓信息。结论 通过wfd-EIT成像方法,利用多频阻抗谱同步测量实现目标区域的快速可视化,并结合RBFNN网络逼近任意非线性函数的优点,实现对目标区域电特性变化的精准识别,为下一步进行临床肺通气的EIT图像监测奠定了理论和技术基础。  相似文献   

11.
ABSTRACT: BACKGROUND: Expiratory time constants are used to quantify emptying of the lung as a whole, and emptying of individual lung compartments. Breathing low-density helium/oxygen mixtures may modify regional time constants so as to redistribute ventilation, potentially reducing gas trapping and hyperinflation for patients with obstructive lung disease. In the present work, bench and mathematical models of the lung were used to study the influence of heterogeneous patterns of obstruction on compartmental and whole-lung time constants. METHODS: A two-compartment mechanical test lung was used with the resistance in one compartment held constant, and a series of increasing resistances placed in the opposite compartment. Measurements were made over a range of lung compliances during ventilation with air or with a 8/22% mixture of helium/oxygen. The resistance imposed by the breathing circuit was assessed for both gases. Experimental results were compared with predictions of a mathematical model applied to the test lung and breathing circuit. In addition, compartmental and whole-lung time constants were compared with those reported by the ventilator. RESULTS: Time constants were greater for larger minute ventilation, and were reduced by substituting helium/oxygen in place of air. Notably, where time constants were long due to high lung compliance (i.e. low elasticity), helium/oxygen improved expiratory flow even for a low level of resistance representative of healthy, adult airways. In such circumstances, the resistance imposed by the external breathing circuit was significant. Mathematical predictions were in agreement with experimental results. Time constants reported by the ventilator were wellcorrelated with those determined for the whole-lung and for the low-resistance compartment, but poorly correlated with time constants determined for the high-resistance compartment. CONCLUSIONS: It was concluded that breathing a low-density gas mixture, such as helium/oxygen, can improve expiratory flow from an obstructed lung compartment, but that such improvements will not necessarily affect time constants measured by the ventilator. Further research is required to determine if alternative measurements made at the ventilator level are predictive of regional changes in ventilation. It is anticipated that such efforts will be aided by continued development of mathematical models to include pertinent physiological and pathophysiological phenomena that are difficult to reproduce in mechanical test systems.  相似文献   

12.
Gravity-dependent changes of regional lung function were studied during normogravity, hypergravity, and microgravity induced by parabolic flights. Seven healthy subjects were followed in the right lateral and supine postures during tidal breathing, forced vital capacity, and slow expiratory vital capacity maneuvers. Regional 1) lung ventilation, 2) lung volumes, and 3) lung emptying behavior were studied in a transverse thoracic plane by functional electrical impedance tomography (EIT). The results showed gravity-dependent changes of regional lung ventilation parameters. A significant effect of gravity on regional functional residual capacity with a rapid lung volume redistribution during the gravity transition phases was established. The most homogeneous functional residual capacity distribution was found at microgravity. During vital capacity and forced vital capacity in the right lateral posture, the decrease in lung volume on expiration was larger in the right lung region at all gravity phases. During tidal breathing, the differences in ventilation magnitudes between the right and left lung regions were not significant in either posture or gravity phase. A significant nonlinearity of lung emptying was determined at normogravity and hypergravity. The pattern of lung emptying was homogeneous during microgravity.  相似文献   

13.
A recently developed method for quantitative assessment of regional lung ventilation was employed for the study of posture-dependent ventilation differences in rats. The measurement employed hyperpolarized (3)He MRI to detect the build-up of the signal intensity after increasing numbers of (3)He breaths, which allowed for computation of a regional ventilation parameter. A group of six anesthetized rats was studied in both supine and prone postures. Three-dimensional maps of the ventilation parameter were obtained with high spatial resolution (voxel volume approximately 2 mm(3)). Vertical (dorsal-ventral) gradients of the ventilation index, defined as the regional ventilation normalized by the average ventilation within the whole lung, were investigated. Variations in the regional distribution of the ventilation parameter, as well as of the ventilation index, could be detected, depending on the posture of the rats. In supine posture, ventilation was elevated in the dependent parts of the lungs, with a linear gradient of the ventilation index of -0.11 +/- 0.03 cm(-1). In prone posture, the distribution of ventilation was more uniform, with a significantly (P < 0.001) smaller gradient of the ventilation index of -0.01 +/- 0.02 cm(-1). It is concluded that the (3)He MRI-based method can detect and quantify regional ventilation gradients in animals as small as the rat and that these gradients depend on prone or supine posture of the animal.  相似文献   

14.

Introduction

Patients with acute respiratory distress syndrome (ARDS) typically show a high degree of ventilation inhomogeneity, which is associated with morbidity and unfavorable outcomes. Electrical impedance tomography (EIT) is able to detect ventilation inhomogeneity, but it is unclear which method for defining the region of interest (ROI) should be used for this purpose. The aim of our study was to compare the functional region of interest (fROI) method to both the lung area estimation method (LAEM) and no ROI when analysing global parameters of ventilation inhomogeneity. We assumed that a good method for ROI determination would lead to a high discriminatory power for ventilation inhomogeneity, as defined by the area under the receiver operating characteristics curve (AUC), comparing patients suffering from ARDS and control patients without pulmonary pathologies.

Methods

We retrospectively analysed EIT data from 24 ARDS patients and 12 control patients without pulmonary pathology. In all patients, a standardized low-flow-pressure volume maneuver had been performed and was used for EIT image generation. We compared the AUC for global inhomogeneity (GI) index and coefficient of variation (CV) between ARDS and control patients using all EIT image pixels, the fROI method and the LAEM for ROI determination.

Results

When analysing all EIT image pixels, we found an acceptable AUC both for the GI index (AUC = 0.76; 95% confidence interval (CI) 0.58–0.94) and the CV (AUC = 0.74; 95% CI 0.55–0.92). With the fROI method, we found a deteriorating AUC with increasing threshold criteria. With the LAEM, we found the best AUC both for the GI index (AUC = 0.89; 95% CI 0.78–1.0) and the CV (AUC = 0.89; 95% CI 0.78–1.0) using a threshold criterion of 50% of the maximum tidal impedance change.

Conclusion

In the assessment of ventilation inhomogeneity with EIT, functional regions of interest obscure the difference between patients with ARDS and control patients without pulmonary pathologies. The LAEM is preferable to the fROI method when assessing ventilation inhomogeneity.  相似文献   

15.
Despite a long history of development, diagnostic tools for in vivo regional assessment of lungs in patients with pulmonary emphysema are not yet readily available. Recently, a new imaging technique, in vivo lung morphometry, was introduced by our group. This technique is based on MRI measurements of diffusion of hyperpolarized (3)He gas in lung air spaces and provides quantitative in vivo tomographic information on lung microstructure at the level of the acinar airways. Compared with standard diffusivity measurements that strongly depend on pulse sequence parameters (mainly diffusion time), our approach evaluates a "hard number," the average acinar airway radius. For healthy dogs, we find here a mean acinar airway radius of approximately 0.3 mm compared with 0.36 mm in healthy humans. The purpose of the present study is the application of this technique for quantification of emphysema progression in dogs with experimentally induced disease. The diffusivity measurements and resulting acinar airway geometrical characteristics were correlated with the local lung density and local lung-specific air volume calculated from quantitative computed tomography data obtained on the same dogs. The results establish an important association between the two modalities. The observed sensitivity of our method to emphysema progression suggests that this technique has potential for the diagnosis of emphysema and tracking of disease progression or improvement via a pharmaceutical intervention.  相似文献   

16.
Recently, a Sendai virus (SeV) model of chronic obstructive lung disease has demonstrated an innate immune response in mouse airways that exhibits similarities to the chronic airway inflammation in human chronic obstructive pulmonary disease (COPD) and asthma, but the effect on distal lung parenchyma has not been investigated. The aim of our study is to image the time course and regional distribution of mouse lung microstructural changes in vivo after SeV infection. (1)H and (3)He diffusion magnetic resonance imaging (MRI) were successfully performed on five groups of C57BL/6J mice. (1)H MR images provided precise anatomical localization and lung volume measurements. (3)He lung morphometry was implemented to image and quantify mouse lung geometric microstructural parameters at different time points after SeV infection. (1)H MR images detected the SeV-induced pulmonary inflammation in vivo; spatially resolved maps of acinar airway radius R, alveolar depth h, and mean linear intercept Lm were generated from (3)He diffusion images. The morphometric parameters R and Lm in the infected group were indistinguishable from PBS-treated mice at day 21, increased slightly at day 49, and were increased with statistical significance at day 77 (p = 0.02). Increases in R and Lm of infected mice imply that there is a modest increase in alveolar duct radius distal to airway inflammation, particularly in the lung periphery, indicating airspace enlargement after virus infection. Our results indicate that (3)He lung morphometry has good sensitivity in quantifying small microstructural changes in the mouse lung and that the Sendai mouse model has the potential to be a valid murine model of COPD.  相似文献   

17.
The objective of this study was to evaluate the regional effects of bronchodilator administration in chronic obstructive pulmonary disease (COPD) using hyperpolarized helium-3 ((3)He) MRI apparent diffusion coefficient (ADC). Ten COPD ex-smokers provided written, informed consent and underwent diffusion-weighted, hyperpolarized (3)He MRI, spirometry, and plethysmography before and 25 ± 2 min after bronchodilator administration. Pre- and postsalbutamol whole-lung (WL) ADC maps were generated and registered together to identify the lung regions containing the (3)He signal at both time points, and mean ADC within those regions of interest (ROI) was determined for a measurement of previously ventilated ROI ADC (ADC(P)). Lung ROI with (3)He signal at both time points was used as a binary mask on postsalbutamol WL ADC maps to obtain an ADC measurement for newly ventilated ROI (ADC(N)). Postsalbutamol, no significant differences were detected in WL ADC (P = 0.516). There were no significant differences between ADC(N) and ADC(P) postsalbutamol (P = 1.00), suggesting that the ADC(N) lung regions were not more emphysematous than the lung ROI participating in ventilation before bronchodilator administration. Postsalbutamol, a statistically significant decrease in ADC(P) (P = 0.01) was detected, and there were significant differences between ADC(P) in the most anterior and most posterior image slices (P = 0.02), suggesting a reduction in regional gas trapping following bronchodilator administration. Regional evaluation of tissue microstructure using hyperpolarized (3)He MRI ADC provides insights into lung alterations that accompany improvements in regional (3)He gas distribution after bronchodilator administration.  相似文献   

18.
Xe-enhanced computed tomography (CT; Xe-CT) is a method for the noninvasive measurement of regional pulmonary ventilation in intact subjects, determined from the washin and washout rates of the radiodense, nonradioactive gas Xe, as measured in serial CT scans. We used the Xe-CT ventilation method, along with other quantitative CT measurements, to investigate the distribution of regional lung ventilation and air content in healthy, anesthetized, mechanically ventilated dogs in the prone and supine postures. Vertical gradients in regional ventilation and air content were measured in five mongrel dogs in both prone and supine postures at four axial lung locations. In the supine position, ventilation increased with dependent location, with a mean slope of 7.3%/cm lung height, whereas no ventilation gradients were found at any location in the prone position. These results agree quantitatively with other published studies. In addition, six different animals were studied (3 supine, 3 prone) to examine the longitudinal distribution of ventilation and air content. The prone lungs were more uniformly inflated compared with the supine, which were less well expanded at the base than apex. Ventilation index, a measure of regional ventilation relative to whole lung ventilation, increased steeply from apex to base in the supine animals, whereas it was again more uniform in the prone condition. We conclude that the Xe-CT method provides a reasonable, quantitative measurement of regional ventilation and promises to be a valuable tool for the noninvasive determination of regional lung function.  相似文献   

19.
Aim: To determine the diagnostic efficiency of 3D Eletrical Impedance Tomography (EIT) compared to Mammography (MG) and Ultrasonography (USG) in imaging the breast. Materials and Methods: A group of 88 patients presenting with various breast complaints was examined using combined Mammography and Ultrasonography (MG & USG) or either of these modalities alone. The same patients were then examined using the 3D EIT imaging system "MEIK". The findings were then compared. The sensitivity of these modalities for this group of patients were later determined and statistically analysed. Results: Of the total of 88 patients, 59 findings were "suspicious" by any of the 3 modalities alone or by their combination. EIT had a sensitivity of 77.8 % compared to MG with a sensitivity of 83.3 % and USG with a sensitivity of 94.4 % regarding cases of fibrocystic mastitis. For cases involving cysts, EIT had 100 % sensitivity which was the same as that for USG compared to MG with a sensitivity of only 81 %. Among cases of fibroadenoma, EIT had a sensitivity of just 68.8 % compared to MG with a sensitivity of 87.5 % and USG with a sensitivity of 75 %. Finally among cases of carcinoma, EIT had a sensitivity of 75 % compared to the sensitivity of 100 % of MG and USG in our group of patients. The study revealed that there was no overall significant difference in sensitivity between MG-USG (p = 0.219) and MG-EIT (p = 0.779) and USG-EIT (p = 0.169). However, in regard to identifying cysts there was significant difference in the sensitivity of MG compared to USG & EIT suggesting that EIT has a role in these cases. Conclusion: Electrical impedance could be used as an adjunct to Mammography and Ultrasonography for breast cancer detection. However, the differentiation of malignant from benign lesions based on impedance measurements needs further investigation. Multifrequency electrical impedance imaging appears the most promising for detecting breast malignancies but methodological improvements need to be made to realise its potential.  相似文献   

20.
Mixing for two gases of markedly different gaseous diffusivity, helium (He) (mol wt = 4) and sulfur hexafluoride (SF6) (mol wt = 146) has been studied by a rebreathing method in different postures. In nine normal subjects duplicate measurements were made in the erect (seated), supine, and lateral decubitus posture, at a constant tidal volume (700 ml) and frequency (1 Hz) starting from functional residual capacity (FRC). Additional measurements were made on four of the subjects, rebreathing seated erect at a volume similar to the relaxed FRC supine and supine at a volume similar to the relaxed FRC seated. In the supine posture the mean breath number to reach 99% equilibrium (n99), was not significantly different for the two gases, 8.9 for He and 9.8 for SF6. There was a difference (P less than 0.01) when erect; n99 (He) = 8.2 and n99 (SF6) = 10.9. The greatest He-SF6 difference (P less than 0.001) was in the lateral decubitus position n99 (He) = 10.1 and n99 (SF6) = 15.9. The mean relaxed FRC as percent of seated was 71% supine and 75% in lateral decubitus posture. Rebreathing seated at a lower volume did not abolish the He-SF6 mixing difference nor did rebreathing at a higher volume when supine induce a He-SF6 mixing difference. Thus the effect of posture on gas mixing cannot be due solely to lung volume and must represent a convective and diffusive dependent change in the distribution of ventilation per unit lung volume.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号