首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Implantable cardioverter-defibrillators (ICDs) serve to reduce the risk of sudden death; however, ICD shocks worsen patient prognosis. Therefore, attempts have been made to terminate life-threatening arrhythmias without ICD shocks. A 71-year-old man with non-ischemic cardiomyopathy, who previously underwent cardiac resynchronization therapy-defibrillator (CRT-D) placement, was hospitalized for ventricular tachyarrhythmia (VT) that was refractory to traditional anti-tachycardia pacing (ATP). Endocardial and epicardial ablation failed to prevent VT recurrence. Since the CRT-D battery was exhausted, it was replaced with a Cobalt? XT HF CRT-D (Medtronic, Minneapolis, MN, USA), and the intrinsic ATP (iATP) algorithm was employed. Although VT recurred frequently, recurrent VTs were terminated by the iATP, which created a conduction block in the circuit without VT acceleration or shock. This is the first reported case wherein an iATP algorithm was effective against VT resistant to traditional anti-tachycardia pacing. This novel ATP algorithm has the potential to terminate refractory VT without ICD shocks and provide a better prognosis.  相似文献   

2.
We tested whether biventricular resynchronization explains contractile function changes with univentricular and biventricular pacing in heart failure patients with varying magnitudes of baseline biventricular asynchrony. Thirty patients (New York Hospital Association class > or = III, QRS duration > or =120 ms) were tested. Contractile function was measured by left ventricular maximum first derivative of pressure over time (dP/dtmax). Biventricular mechanical asynchrony was quantified by the normalized pressure-pressure (NPP) loop area formed by the cross-plot of right and left intraventricular pressure curves from each cardiac cycle. Any ventricular pacing increased dP/dtmax if it decreased baseline NPP loop area and almost always worsened dP/dtmax and asynchrony when baseline NPP loop area <0.3. The quantitative relationship between dP/dtmax and NPP loop area change depended on ventricular pacing site and timing relative to intrinsic activation. For similar NPP loop decreases, dP/dtmax increased 16% more with left and biventricular pacing compared with right ventricular pacing. In conclusion, right, left, or biventricular pacing can improve contractile function only in patients having sufficient baseline biventricular asynchrony. However, biventricular resynchronization is only one of the improvement mechanisms.  相似文献   

3.
BackgroundCardiac resynchronization therapy (CRT) has been shown to improve both the functional status and mortality of heart failure patients with left bundle branch block. Multiple recent studies suggest several mechanisms for proarrhythmia associated with CRT device.Case summaryA 51-year-old male with symptomatic non-ischemic cardiomyopathy and no previous history of ventricular arrhythmias underwent placement of a biventricular cardioverter-defibrillator. The patient developed sustained monomorphic ventricular tachycardia (VT) soon after implantation. The VT recurred despite reprogramming to right ventricular only pacing. The electrical storm resolved only after a subsequent discharge from the defibrillator caused inadvertent dislodgement of the coronary sinus lead. No recurrent VT occurred throughout 10-years follow up after urgent coronary sinus lead revision.DiscussionWe describe the first reported case of mechanically induced electrical storm due to the physical presence of the CS lead in a patient with a new CRT-D device. It is important to recognize mechanical proarrhythmia as a potential mechanism of electrical storm, as it may be intractable to device reprogramming. Urgent coronary sinus lead revision should be considered. Further studies on this mechanism of proarrhythmia are needed.  相似文献   

4.
Right Ventricular Apical permanent pacing could have negative hemodynamic effects. A physiologic pacing modality should preserve a correct atrio-ventricular and interventricular synchronization. This can be obtained through biventricular pacing, left ventricular pacing, or from alternative right ventricular pacing sites. Direct His Bundle Pacing (DHBP) was documented as reliable and effective for preventing the desynchronization and negative effects of right ventricular apical pacing. It is, however, a complex method that requires longer average implant times, cannot be carried out on all patients and presents high pacing thresholds. On the contrary, the parahisian pacing, with simpler feasibility and reliability criteria, seems to guarantee an early invasion of the His-Purkinje conduction system, with a physiological ventricular activation, very similar to the one that can be obtained with direct His bundle pacing. We present our experience on 68 patients who underwent a permanent right ventricular pacing in hisian/parahisian region, for advanced AV block and narrow QRS. In the first 17 patients we performed a double-blind randomized controlled study, with two 6-months cross-over periods in parahisian and apical pacing, documenting a significant improvement of NYHA class, exercise tolerance, quality of life score, mitral and tricuspidal regurgitation degree, and interventricular mechanical delay. In the subsequent 51 patients, in a mean follow of 21 months/patient, the pacing threshold remained stable (0.7+/-0.5 V implant; 0.9+/-0.7 V follow-up; p=0.08). The ejection fraction maintained medium-long term stable values, confirming the fact that the parahisian pacing can prevent deterioration of the left ventricular function. Parahisian pacing, therefore, has proven to be a reliable method, easy to apply and effective in preventing the negative effects induced by non-physiological right ventricular apical pacing.  相似文献   

5.
Cardiac resynchronisation therapy (CRT) using biventricular (BIV) pacing has proved its effectiveness to correct myocardial asynchrony and improve clinical status of patients with severe congestive heart failure (CHF) and widened QRS. Despite a different effect on left ventricular electrical dispersion, left univentricular (LV) pacing is able to achieve the same mechanical synchronisation as BIV pacing in experimental studies and in humans. This results in clinical benefits of LV pacing at mid-term follow-up, with significant improvement in functional class, quality of life and exercise tolerance at the same extent as those observed with BIV stimulation in non randomised studies. Furthermore these benefits are obtained at lesser costs and with conventional dual-chamber devices. However, LV pacing has to be compared to BIV pacing in randomised trials before being definitely considered as a cost-effective alternative to BIV pacing.  相似文献   

6.
BackgroundPremature ventricular contractions (PVC) are known to reduce the percentage of biventricular (BiV) pacing in patients with cardiac resynchronization (CRT), decreasing the clinical response. The aim of this study was to evaluate the prevalence of a high PVC burden, as well as therapeutic action (pharmacotherapy, catheter ablation or device programming), in a large CRT implantable-defibrillator (CRT-D) population.MethodsPatients with a CRT-D device from the UMBRELLA multicenter prospective remote monitoring registry were included. The PVC count was collected from each remote monitoring transmission. Patients were divided into two high (≥1 transmission ≥200/≥400 PVC/h, respectively) and one low (all transmissions <200 PVC/h) PVC count groups. The PVC burden following a high PVC count transmission was calculated.ResultsOf 1268 patients, 135 (11%) and 43 (3.4%) presented high PVC count (≥200/≥400 PVC/h, respectively). The majority of patients in the high PVC groups were not treated (61 [79%] and 32 [74%], respectively. Considering the untreated patients in the high PVC groups, median PVC/h was 199 (interquartile range [IQR]: 196) and 271 (IQR: 330), respectively. The PVC burden (proportion of time with PVC/h ≥ 200/≥400) was 40% (IQR 70) and 29% (IQR 59), respectively.ConclusionA significant proportion of CRT-D patients presented a high PVC count, however, few received treatment. In the untreated patients with a high PVC count, the PVC burden during follow-up varied substantially. Several consecutive recordings of a high PVC count should be warranted before considering therapeutic action such as catheter ablation.  相似文献   

7.
Guy Haywood 《Trials》2001,2(6):292-6
Biventricular pacing or resynchronisation therapy is a non-pharmacological therapy for patients with chronic heart failure. Since being originally described in 1994, biventricular pacing has become a subject of intense interest and investigation. This review analyses the results reported in observational series and randomised trials, and seeks to answer two questions. If it works, why does it work? Which heart failure patients will it benefit?  相似文献   

8.
Advances in pacemaker technology in the 1980s have generated a wide variety of complex multiprogrammable pacemakers and pacing modes. The aim of the present review is to address the different rate responsive pacing modalities presently available in respect to physiological situations and pathological conditions. Rate adaptive pacing has been shown to improve exercise capacity in patients with chronotropic incompetence. A number of activity and metabolic sensors have been proposed and used for rate control. However, all sensors used to optimize pacing rate metabolic demands show typical limitations. To overcome these weaknesses the use of two sensors has been proposed. Indeed an unspecific but fast reacting sensor is combined with a more specific but slower metabolic one. Clinical studies have demonstrated that this methodology is suitable to reproduce normal sinus behavior during different types and loads of exercise. Sensor combinations require adequate sensor blending and cross checking possibly controlled by automatic algorithms for sensors optimization and simplicity of programming. Assessment and possibly deactivation of some automatic functions should be also possible to maximize benefits from the dual sensor system in particular conditions. This is of special relevance in patient whose myocardial contractility is limited such as in subjects with implantable defibrillators and biventricular pacemakers. The concept of closed loop pacing, implementing a negative feedback relating pacing rate and the control signal, will provide new opportunities to optimize dual-sensors system and deserves further investigation. The integration of rate adaptive pacing into defibrillators is the natural consequence of technical evolution.  相似文献   

9.
We describe two cases in which a biventricular implantable cardioverter defibrillator for cardiac resynchronization therapy had to be placed on the right side due to unsuitability of the left subclavian vein. Endocardial implantation of a left ventricular lead through the coronary sinus was previously attempted but was unsuccessful. Implantation of the epicardial left ventricular pacing lead was performed through video-assisted thoracic surgery on the left side. The connector end of the left ventricular pacing lead was tunnelized through the anterior mediastinum into the right pleural space. The right-sided pocket was then opened. A tunnel was created from the pocket to the thoracic wall, and the pleural space was entered over the second rib. The lead was retrieved from the right pleural space and connected with the Cardiac resynchronization therapy-device (CRT-D). Both procedures and postoperative periods were uneventful. Intrathoracic left-to-right tunneling of an epicardial left ventricular lead by video-assisted thoracic surgery is feasible and safe. It provides an alternative to subcutaneous tunneling.  相似文献   

10.

Background

Dual chamber pacing improves functional status and reduces left ventricular outflow tract gradients in some, but not all patients with hypertrophic cardiomyopathy (HCM) by altering ventricular depolarisation. We investigated the use of biventricular (BIV) pacing in symptomatic patients with HCM.

Method

8 patients aged 58±7yrs with symptomatic HCM underwent BIV pacing. 5 patients had LVOT gradients >30mmHg. Ventricular electrodes were placed in the right ventricle (RV) and a branch of the coronary sinus. An atrial electrode was inserted to achieve BIV pacing with a short AV delay. The short-term effects of different pacing modalities were assessed using 2-D and Doppler echocardiography. Symptoms and exercise tolerance were assessed after a month of each pacing mode. Long-term follow up data was available for 5 years.

Results

Baseline EF was 67±14% and mean QRS duration was 132±26msecs. BIV pacing reduced QRS duration compared to RV pacing (129±46 vs. 205±54msecs, p<0.005). Five of the seven patients had baseline LVOT gradients (mean 67±25mmHg) that decreased to 41±15mm Hg with RV pacing (p<0.01) and 25±15mmHg with BIV pacing (p<0.005). Improvements in exercise time with active pacing occurred in six out of eight patients (75%), three (37.5%) had optimal exercise times with RV pacing and three with BIV pacing. Of the three patients with short term improvements with BIV pacing, one died 4 years post implant, one deteriorated with LV dilatation and one had the system explanted for infection.

Conclusion

BIV pacing showed short-term beneficial effects in some patients over and above RV pacing alone.  相似文献   

11.
Recently, attention has been focused on comparing left ventricular (LV) endocardial (ENDO) with epicardial (EPI) pacing for cardiac resynchronization therapy. However, the effects of ENDO and EPI lead placement at multiple sites have not been studied in failing hearts. We hypothesized that differences in the improvement of ventricular function due to ENDO vs. EPI pacing in dyssynchronous (DYSS) heart failure may depend on the position of the LV lead in relation to the original activation pattern. In six nonfailing and six failing dogs, electrical DYSS was created by atrioventricular sequential pacing of the right ventricular apex. ENDO was compared with EPI biventricular pacing at five LV sites. In failing hearts, increases in the maximum rate of LV pressure change (dP/dt; r = 0.64), ejection fraction (r = 0.49), and minimum dP/dt (r = 0.51), relative to DYSS, were positively correlated (P < 0.01) with activation time at the LV pacing site during ENDO but not EPI pacing. ENDO pacing at sites with longer activation delays led to greater improvements in hemodynamic parameters and was associated with an overall reduction in electrical DYSS compared with EPI pacing (P < 0.05). These findings were qualitatively similar for nonfailing hearts. Improvement in hemodynamic function increased with activation time at the LV pacing site during ENDO but not EPI pacing. At the anterolateral wall, end-systolic transmural function was greater with local ENDO compared with EPI pacing. ENDO pacing and intrinsic activation delay may have important implications for management of DYSS heart failure.  相似文献   

12.
Cardiac resynchronization therapy (CRT) is a proven treatment for heart failure but ~30% of patients appear to not benefit from the therapy. Left ventricular (LV) endocardial and multisite epicardial [triventricular (TriV)] pacing have been proposed as alternatives to traditional LV transvenous epicardial pacing, but no study has directly compared the hemodynamic effects of these approaches. Left bundle branch block ablation and repeated microembolizations were performed in dogs to induce electrical dysynchrony and to reduce LV ejection fraction to <35%. LVdP/dt(max) and other hemodynamic indexes were measured with a conductance catheter during LV epicardial, LV endocardial, biventricular (BiV) epicardial, BiV endocardial, and TriV pacing performed at three atrioventricular delays. LV endocardial pacing was obtained with a clinically available pacing system. The optimal site was defined as the site that increased dP/dt(max) by the largest percentage. Implantation of the endocardial lead was feasible in all canines (n = 8) without increased mitral regurgitation seen with transesophageal echocardiography and with full access to the different LV endocardial pacing sites. BiV endocardial pacing increased dP/dt(max) more than BiV epicardial and TriV pacing on average (P < 0.01) and at the optimal site (P < 0.01). There were no significant differences between BiV epicardial and TriV pacing. BiV endocardial pacing was superior to BiV epicardial and to TriV pacing in terms of acute hemodynamic response. Further investigation is needed to confirm the chronic benefit of this approach in humans.  相似文献   

13.
Cardiac resynchronization therapy is not commonly used in the early postoperative period in patients undergoing cardiac surgery who have left ventricular (LV) dysfunction and a history of heart failure. We performed a prospective randomized clinical trial to compare atrial synchronous right ventricular (DDD RV) and biventricular (DDD BIV) pacing within 72 hours after cardiac surgery in patients with an EF ≤35 %, a QRS interval longer than 120 msec and who had LV dyssynchrony detected by real-time three-dimensional echocardiography (RT3DE). Epicardial pacing was provided by a modified Medtronic INSYNC III pacemaker. An LV epicardial pacing lead was implanted on the latest activated segment of the LV based on RT3DE. The study included 18 patients with ischemic heart disease, with or without valvular heart disease (14 men, 4 women, average age 71 years). Patients undergoing DDD BIV pacing had a statistically significant greater CO and CI (CO 6.7±1.8 l/min, CI 3.4±0.7 l/min/m(2)) than patients undergoing DDD RV pacing (CO 5.5±1.4 l/min, CI 2.8±0.7 l/min/m(2)), p<0.001. DDD BIV pacing in the early postoperative period after cardiac surgery corrects LV dyssynchrony and has better hemodynamic results than DDD RV pacing.  相似文献   

14.
In patients with sick sinus syndrome and normal atrioventricular conduction, physiological pacing can be accomplished with either a single chamber atrial pacemaker AAI/R or a dual chamber pacemaker DDD/R. The single chamber device has the advantages of simpler implantation and lower initial costs, while the dual chamber device offers protection in case atrioventricular conduction disturbances develop in the future. When rigorous attention is paid to the pre-implantation selection criteria, the incidence of reported second- or third-degree atrioventricular block varied between 0.4 and 1.8% per annum. Medical practice, however, has shifted to predominant implantation of DDD/R pacemakers in more than 95% of patients with sick sinus syndrome. Recent publications have reported an increase in left atrial diameter, decrease in left ventricular fractional shortening and increased incidence of atrial fibrillation in patients with DDD/R pacing as compared with patients with single chamber atrial devices. These changes were proportional to the percentage of ventricular paced beats. New algorithms in dual chamber devices have been developed in order to minimise ventricular stimulation. These are being evaluated at present. In my opinion there is still a place for atrial pacing in selected patients with sick sinus syndrome with a minimum risk of developing complete atrioventricular block. (Neth Heart J 2008;16(suppl 1): S25-S27.)  相似文献   

15.
BackgroundIn patients with cardiac resynchronization therapy defibrillators (CRT-Ds), intracardiac impedance measured by dedicated CRT-D software may be used to monitor hemodynamic changes. We investigated the relationship of hemodynamic parameters assessed by intracardiac impedance and by echocardiography in a controlled clinical setting.MethodsThe study enrolled 68 patients (mean age, 66 ± 9 years; 74% males) at 12 investigational sites. The patients had an indication for CRT-D implantation, New York Heart Association class II/III symptoms, left ventricular ejection fraction 15%–35%, and a QRS duration ≥150 ms. Two months after a CRT-D implantation, hemodynamic changes were provoked by overdrive pacing. Intracardiac impedance was recorded at rest and at four pacing rates ranging from 10 to 40 beats/min above the resting rate. In parallel, echocardiography measurements were performed. We hypothesized that a mean intra-individual correlation coefficient (rmean) between stroke impedance (difference between end-systolic and end-diastolic intracardiac impedance) measured by CRT-D and the aortic velocity time integral (i.e., stroke volume) determined by echocardiography would be significantly larger than 0.65.ResultsThe hypothesis was evaluated in 40 patients with complete data sets. The rmean was 0.797, with a lower confidence interval bound of 0.709. The study hypothesis was met (p = 0.007). A stepwise reduction of stroke impedance and stroke volume was observed with increasing heart rate.ConclusionsIntracardiac impedance measured by implanted CRT-Ds correlated well with the aortic velocity time integral (stroke volume) determined by echocardiography. The impedance measurements bear potential and are readily available technically, not requiring implantation of additional material beyond standard CRT-D system.  相似文献   

16.
Bai R  Pu J  Liu N  Lu JG  Zhou Q  Ruan YF  Niu HY  Wang L 《生理学报》2003,55(6):722-730
实验以正常犬和扩张型心肌病心力衰竭犬(dilated cardiomyopathy congestive heart failure,DCM-CHF)模型为对象、以心肌跨室壁复极离散的相关参数为指标,研究左心室心外膜起搏、双心室起搏(模拟临床上心室再同步治疗的方法)后的心肌电生理特性变化。实验以快速右心室起搏的方法制备DCM-CHF犬模型;正常犬和DCM-CHF犬均经射频消融希氏束制备三度房室传导阻滞模型;采用同步记录犬体表心电图和内膜下、中层、外膜下三层心肌单相动作电位(monophasic action potentials,MAP)的方法,测定不同部位起搏时的QT间期、Tpeak-Tend(Tp-Te)间期和三层心肌的单相动作电位时程(MAP duration,MAPD)、跨室壁复极离散度(transmural dispersion of repolaization,TDR)。结果显示:在正常犬,左室心外膜与双心室起搏后三层心肌的MAPD均延长,同时TDR增大(左室心外膜起搏47.16 ms、双心室起搏37.54 ms、右室心内膜起搏26.75 ms,P<0.001),体表心电图Tp-Te间期的变化与之平行;在DCM-CHF犬较正常犬已表现出中层心肌MAPD延长(276.30 ms vs 257.35 ms,P<0.0001)和TDR(33.8 ms vs 27.58 ms,P=0.002)增大的基础上,左室心外膜参与起搏后仍进一步使三层心肌的MAPD延长和TDR增大。研究结果提示,左室心外膜起搏和双心室起搏后使内膜下、中层  相似文献   

17.
We present a case of a single chamber atrial pacemaker implanted for sinus node dysfunction and treatment of macroreentrant atrial tachycardias with atrial antitachycardia pacing. The patient presented with sustained atrial tachycardia above the detection rate, however, the device was unable to detect the tachycardia and did not deliver the programmed therapy. We discuss the nuances of the atrial tachyarrhythmia detection algorithms, and the programming strategies to maximize detection of atrial arrhythmias in a single chamber atrial pacemaker.  相似文献   

18.
Pacing prevention algorithms have been introduced in order to maximize the benefits of atrial pacing in atrial fibrillation prevention. It has been demonstrated that algorithms actually keep overdrive atrial pacing, reduce atrial premature contractions, and prevent short-long atrial cycle phenomenon, with good patient tolerance. However, clinical studies showed inconsistent benefits on clinical endpoints such as atrial fibrillation burden. Factors which may be responsible for neutral results include an already high atrial pacing percentage in conventional DDDR, non-optimal atrial pacing site and deleterious effects of high percentages of apical ventricular pacing. Atrial antitachycardia pacing (ATP) therapies are effective in treating spontaneous atrial tachyarrhythmias, mainly when delivered early after arrhythmia onset and/or on slower tachycardias. Effective ATP therapies may reduce atrial fibrillation burden, but conflicting evidence does exist as regards this issue, probably because current clinical studies may be underpowered to detect such an efficacy. Wide application of atrial ATP may reduce the need for hospitalizations and electrical cardioversions and favorably impact on quality of life. Consistent monitoring of atrial and ventricular rhythm as well as that of ATP effectiveness may be extremely useful for optimizing device programming and pharmacological therapy.  相似文献   

19.
Asynchronous myocardial contraction in heart failure is associated with poor prognosis. Resynchronization can be achieved by biventricular pacing (BVP), which leads to clinical improvement and reverse remodeling. However, there is a substantial subset of patients with wide QRS complexes in the electrocardiogram that does not improve despite BVP. QRS width does not predict benefit of BVP and only correlates weakly with echocardiographically determined myocardial asynchrony. Determination of asynchrony by Tissue Doppler echocardiography seems to be the best predictor for improvement after BVP, although no consensus on the optimal method to assess asynchrony has been achieved yet. Our own preliminary results show the usefulness of Tissue Doppler Imaging and Tissue Synchronization Imaging to document acute and sustained improvement after BVP. To date, all studies evaluating Tissue Doppler in BVP were performed retrospectively and no prospective studies with patient selection for BVP according to echocardiographic criteria of asynchrony were published yet. We believe that these new echocardiographic tools will help to prospectively select patients for BVP, help to guide implantation and to optimize device programming.  相似文献   

20.
Diaphragmatic pacing is a valuable tool that can significantly benefit certain patients with respiratory insufficiency provided they have an intact phrenic nerve and a functional diaphragm. Careful patient selection is critical to successful long-term results. The main populations that derive benefit from pacing include those with congenital or acquired central hypoventilation syndrome and more commonly those with a high cervical spinal cord injury, where the phrenic nerves remain intact. The pacing electrode of most phrenic nerve pacemakers is implanted directly on the phrenic nerve. A newer device relies on intramuscular implantation of the electrode on the diaphragm at the phrenic nerve motor point. Most patients can be successfully weaned from mechanical ventilation for a substantial time each day, if not completely. This has significant impact on quality of life and implications for healthcare costs. The potential exists for application of this technology to patients with other types of respiratory failure as investigative experience emerges. These include the chronic progressive disease, amyotrophic lateral sclerosis, or temporary scenarios in difficult-to-wean intensive care unit patients. This enabling technology should hold a place in the thoracic surgeon's armamentarium.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号