首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 22 毫秒
1.
A simple, accurate, precise, specific and reproducible high-performance liquid chromatography (HPLC) method was developed for determination of trans-polydatin, a natural strong anti-oxidative compound, in rat plasma and cell suspension. The assay procedure involved simple liquid-liquid extraction, the supernatant liquid was added an equal volume of water to avoid solvent effect. The detection of the analyte peak was achieved by monitoring the eluate using a UV detector set at 303 nm. The analysis used a Hypersil ODS2 C18 column (5 microm, 4.6 mm x 250 mm) and methanol/distilled water as the mobile phase (flow rate=1 mL/min). A total analytical run was achieved within 6.0 min and calibration curve was linear over a wide concentration range of 0.25-40 microg/mL for plasma sample and 1.0-500 microM for cell suspension, the coefficients of correlation were 0.9997 and 0.9999 or better, respectively. There was 80.7+/-7.86%, 96.8+/-3.20% and 102.7+/-9.72% recovery from 0.5, 10, and 40 microg/mL plasma samples, respectively. Intra- and inter-batch accuracy and precision were acceptable for the both matrices. The RSD of intra- and inter-day assay variations were all less than 10%. Both analyte and IS were stable in the battery of stability studies, freeze-thaw cycles. The described assay method was applied to pharmacokinetic studies in rats and a human colon adenocarcinoma cell line (Caco-2) successfully. The application of the assay to determine the pharmacokinetic is described.  相似文献   

2.
A simple and sensitive HPLC method has been developed and validated for the determination of oridonin (ORI) in rabbit plasma. A simple liquid-liquid extraction (LLE) method was applied to extract ORI and the internal standard (IS), isopsoralen, from rabbit plasma. Chromatographic separation of ORI and the IS was achieved with a Kromasil C18 5-mum column (250 mm x 4.6 mm) using methanol-water (50:50, v/v) as mobile phase at a flow rate of 1 mL/min. The ultraviolet (UV) detection wavelength was set at 241 nm. The lower limit of quantification (LLOQ) was 0.02 microg/mL. The calibration curves were linear over a concentration range of 0.02-10 microg/mL. The assay accuracy and precision were within the range of 95.1-113.5% and 5.4-8.6%, respectively. This HPLC method was applied successfully to the pharmacokinetic study of ORI-loaded poly(caprolactone)-poly(ethylene oxide)-poly(caprolactone) copolymer nanoparticles (ORI-PCL-PEO-PCL-NP) in rabbits, given as a single intravenous injection at the dose equivalent to 2mg of ORI/kg, and the pharmacokinetic parameters for ORI were compared with a single intravenous injection of a ORI solution at the same dose.  相似文献   

3.
A rapid and simple high-performance liquid chromatographic (HPLC) method has been developed for the determination of p-coumaric acid in rat plasma and applied to a pharmacokinetic study in rats after administration of a prodrug, E-6-O-p-coumaroyl scandoside methyl ester, isolated from Hedyotis diffusa (Willd.). Sample preparation involved protein precipitation with acetonitrile. The supernatant was then injected onto a Diamonsil C(18) column (250 mm x 4.6mm i.d., 5 microm). The mobile phase consisted of acetonitrile-water (21:79, v/v) with 1% glacial acetic acid. The UV detector was set at 310 nm. The lower limit of quantification of p-coumaric acid in rat plasma was 0.02 microg/mL. The calibration curves were linear over the concentration range 0.02-5 microg/mL with correlations greater than 0.999. The assay procedure was applied to the study of the metabolite pharmacokinetics of E-6-O-p-coumaroyl scandoside methyl ester in rat.  相似文献   

4.
A HPLC method with UV detection at 262nm was developed to analyze inositol hexanicotinate in rat plasma. Plasma samples were extracted with an equal volume of acetonitrile, followed by dilution with mobile phase buffer (5mM phosphate buffer, pH 6.0) to eliminate any solvent effects. Inositol hexanicotinate and the internal standard (mebendazole) were separated isocratically using a mobile phase of acetonitrile/phosphate buffer (35:65, v/v, pH 6.0) at a flow rate of 1.0mL/min and a reverse-phase XTerra MS C(18) column (4.6mmx150mm, 3.5microm). The standard curve was linear over a concentration range of 1.5-100.0microg/mL of inositol hexanicotinate in rat plasma. The HPLC method was validated with intra- and inter-day precisions of 1.55-4.30% and 2.69-21.5%, respectively. The intra- and inter-day biases were -0.75 to 19.8% and 2.58-22.0%, respectively. At plasma concentrations of 1.5-100microg/mL, the mean recovery of inositol hexanicotinate was 99.6%. The results of a stability study indicated that inositol hexanicotinate was unstable in rat plasma samples, but was stable in acetonitrile extracts of rat plasma for up to 24h at 4 degrees C. The assay is simple, rapid, specific, sensitive, and reproducible and has been used successfully to analyze inositol hexanicotinate plasma concentrations in a pharmacokinetic study using the rat as an animal model.  相似文献   

5.
A rapid, selective and sensitive HPLC assay has been developed for the routine analysis of amoxicillin in rat plasma, gastric juice aspirate and gastric tissue which is applicable to low concentrations of amoxicillin (<1 microg mL(-1)) or small sample volumes. Amoxicillin was converted, via an internal rearrangement, to form a fluorescent product which was subsequently recovered using liquid-liquid extraction. A Kromasil ODS 3 microm (150 x 3.2 mm I.D.) column was maintained at 40 degrees C and used with a mobile phase consisting of methanol-water (55:45, v/v). Fluorimetric detection was at an lambda(ex) of 365 nm and an lambda(em) of 445 nm. The limits of quantitation for amoxicillin were 0.1 microg mL(-1) for gastric juice aspirate (500 microL), 0.5 microg mL(-1) for plasma (50 microL) and 0.075 microg g(-1) for gastric tissue (250 mg). The method was linear up to at least 15 microg mL(-1) in gastric juice aspirate, up to 200 microg mL(-1) in plasma and up to 100 microg g(-1) in gastric tissue, with inter- and intra-day RSDs being less than 19%. The assay has been applied to the measurement of amoxicillin in rat plasma, gastric juice aspirate and gastric tissue for pharmacokinetic studies in individual rats.  相似文献   

6.
A simple, rapid and precise HPLC method using ultrafiltration to remove plasma protein was developed to determine biapenem concentrations in human plasma. Plasma was separated by centrifugation at 4 degrees C from blood collected in heparinized vacuum tubes, and biapenem was stabilized by immediate mixing the plasma with 1M 3-morpholinopropanesulfonic acid (MOPS) buffer (pH 7.0) (1:1). Biapenem was detected by ultraviolet absorbance at 300nm with no interfering plasma peak. The calibration curve of biapenem in human plasma was linear from 0.04 to 50microg/mL. The limit of detection was 0.01microg/mL, which was more than 40-fold lower than that of conventional plasma protein precipitation using ammonium sulfate. The assay has been clinically applied to pharmacokinetic studies in patients.  相似文献   

7.
In the present study, we developed a fast and reliable HPLC assay for the determination of the new triazole antifungal agent voriconazole in plasma, using a Chromolith RP 18e (100 mm x 4.6 mm) monolithic silica rod HPLC column. After liquid-liquid extraction, plasma samples were separated with a mobile phase consisting of ammoniumdihydrogencarbonate buffer (pH 5.8)-acetonitrile-tetrahydrofuran (72:25:3) at a flow-rate of 3.5 mL/min and UV detection at 255 nm. The retention times for voriconazole and internal standard (UK-115794) were 2.3 and 2.7 min, respectively, and total run time was 4 min. The calibration curves were linear between 0.05 and 10 microg/mL, and within-assay and between-assay coefficients of variation were <4%. The proposed assay for voriconazole in plasma is fast, sensitive and reliable, and, thus, well suited for routine therapeutic monitoring of patients and for pharmacokinetic studies. It can be predicted that the use of monolithic silica rod chromatography will substantially shorten the turn-around time in the therapeutic drug monitoring laboratory.  相似文献   

8.
A simple, rapid, and precise high-performance liquid chromatography (HPLC) method using ultrafiltration to remove plasma protein was developed to determine meropenem concentrations in human plasma in a clinical setting. Plasma was separated by centrifugation at 4 degrees C from blood collected in heparinized vacuum tubes, and meropenem was stabilized by immediately mixing the plasma with 1M 3-morpholinopropanesulfonic acid buffer (pH 7.0) (1:1). Ultrafiltration was used for plasma deproteinization. Meropenem was detected by ultraviolet absorbance at 300 nm with no interfering plasma peak. The calibration curve of meropenem in human plasma was linear from 0.05 to 100 microg/mL. Intraday and interday precision was less than 7.17% (CV), and accuracy was between 97.7% and 106.3% over 0.05 microg/mL. The limit of detection was 0.01 microg/mL. The assay has been clinically applied to a real-time therapeutic drug monitoring in pediatric patients and pharmacokinetic studies.  相似文献   

9.
A simple high-performance liquid chromatographic (HPLC) method has been developed for the determination of epimedin C in rat plasma and applied to a pharmacokinetic study in rats after administration of Herba Epimedii extract. After addition of carbamazepine as an internal standard plasma samples were extracted with ethyl acetate. HPLC analysis of the extracts was performed on a Hypersil ODS2 analytical column using acetonitrile -0.4% acetic acid (25:75, v/v) as the mobile phase. The UV detector was set at 260 nm. The standard curve was linear over the range 0.05-4.0 microg/mL. The lower limit of quantification was 0.05 microg/mL. The HPLC method developed could be easily applied to the determination and pharmacokinetic study of epimedin C in rat plasma after giving the animals Herba Epimedii extract.  相似文献   

10.
A rapid and simple high-performance liquid chromatographic method for the determination of the R-(-)- and S-(+)-enantiomers of the antiepileptic drug vigabatrin in human plasma is described. After adding the internal standard (1-aminomethyl-cycloheptyl-acetic acid), plasma samples (200 microL) are deproteinized with acetonitrile and the supernatant is derivatized with 2,4,6 trinitrobenzene sulfonic acid (TNBSA). Separation is achieved on a reversed-phase cellulose-based chiral column (Chiralcel-ODR, 250 mm x 4.6 mm i.d.) using 0.05 M potassium hexafluorophosphate (pH 4.5)/acetonitrile/ethanol (50:40:10 vol/vol/vol) as mobile phase at a flow-rate of 0.9 mL/min. Chromatographic selectivity is improved by concentrating the derivatives on High Performance Extraction Disk Cartridges prior to injection. Detection is at 340 nm. Calibration curves are linear (r(2)> or =0.999) over the range of 0.5-40 microg/mL for each enantiomer, with a limit of quantification of 0.5 microg/mL for both analytes. The assay is suitable for therapeutic drug monitoring and for single-dose pharmacokinetic studies in man.  相似文献   

11.
Clinical pharmacokinetic studies of ciprofloxacin require accurate and precise measurement of plasma drug concentrations. We describe a rapid, selective and sensitive HPLC method coupled with fluorescence detection for determination of ciprofloxacin in human plasma. Internal standard (IS; sarafloxacin) was added to plasma aliquots (200 μL) prior to protein precipitation with acetonitrile. Ciprofloxacin and IS were eluted on a Synergi Max-RP analytical column (150 mm×4.6 mm i.d., 5 μm particle size) maintained at 40°C. The mobile phase comprised a mixture of aqueous orthophosphoric acid (0.025 M)/methanol/acetonitrile (75/13/12%, v/v/v); the pH was adjusted to 3.0 with triethylamine. A fluorescence detector (excitation/emission wavelength of 278/450 nm) was used. Retention times for ciprofloxacin and IS were approximately 3.6 and 7.0 min, respectively. Calibration curves of ciprofloxacin were linear over the concentration range of 0.02-4 μg/mL, with correlation coefficients (r(2))≥0.998. Intra- and inter-assay relative standard deviations (SD) were <8.0% and accuracy values ranged from 93% to 105% for quality control samples (0.2, 1.8 and 3.6 μg/mL). The mean (SD) extraction recoveries for ciprofloxacin from spiked plasma at 0.08, 1.8 and 3.6 μg/mL were 72.8±12.5% (n=5), 83.5±5.2% and 77.7±2.0%, respectively (n=8 in both cases). The recovery for IS was 94.5±7.9% (n=15). The limits of detection and quantification were 10 ng/mL and 20 ng/mL, respectively. Ciprofloxacin was stable in plasma for at least one month when stored at -15°C to -25°C and -70°C to -90°C. This method was successfully applied to measure plasma ciprofloxacin concentrations in a population pharmacokinetics study of ciprofloxacin in malnourished children.  相似文献   

12.
A rapid and simple high-performance liquid chromatographic (HPLC) method has been developed and validated for determination of scopoletin in rat plasma using psoralen as internal standard. Chromatographic separation was achieved on a C(18) column using methanol and distilled water (49:51, v/v) containing 0.05% (v/v) phosphoric acid as mobile phase. The UV detector was set at 345 nm. The calibration curve was linear over the range of 0.165-9.90 microg/ml with a correlation coefficient of 0.9994. The recovery for plasma samples of 0.165, 1.32 and 6.60 microg/ml was 93.2%, 95.9% and 95.5%, respectively. The RSD of intra- and inter-day assay variations was less than 6.7%. This HPLC assay is a precise and reliable method for the analysis of scopoletin in pharmacokinetic studies.  相似文献   

13.
建立大鼠血浆和脑中Z-槀苯内酯(LIG)浓度测定的高效液相色谱法。采用Agilent Hypersil ODS C18色谱柱(150mm×4.6mm,5μm),流动相为甲醇-5%异丙醇水溶液(60:40,v/v),流速为1.0mL/min,检测波长为280nm。血浆与脑中槀苯内酯浓度线性检测范围分别为93.75~3750ng/m(r=0.9999)和93.75~3750ng/g(r=0.9997),日内及日间精密度RSD10%。本法适用于大鼠口服LIG后血浆及脑中药物浓度的研究。  相似文献   

14.
A 96-well protein precipitation, liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and fully validated for the determination of fudosteine in human plasma. After protein precipitation of the plasma samples (50 microL) by the methanol (150 microL) containing the internal standard (IS), erdosteine, the 96-well plate was vortexed for 5 min and centrifuged for 15 min. The 100 microL supernatant and 100 microL mobile phase were added to another plate and mixed and then the mixture was directly injected into the LC-MS/MS system in the negative ionization mode. The separation was performed on a XB-CN column for 3.0 min per sample using an eluent of methanol-water (60:40, v/v) containing 0.005% formic acid. Multiple reaction monitoring (MRM) using the precursor-product ion transitions m/z 178-->91 and m/z 284-->91 was performed to quantify fudosteine and erdosteine, respectively. The method was sensitive with a lower limit of quantification (LLOQ) of 0.02 microg mL(-1), with good linearity (r>0.999) over the linear range of 0.02-10 microg mL(-1). The within- and between-run precision was less than 5.5% and accuracy ranged from 94.2 to 106.7% for quality control (QC) samples at three concentrations of 0.05, 1 and 8 microg mL(-1). The method was employed in the clinical pharmacokinetic study of fudosteine formulation product after oral administration to healthy volunteers.  相似文献   

15.
A simple and rapid HPLC method that includes ultrafiltration to remove plasma and peritoneal fluid protein was developed to determine doripenem concentrations in human plasma and peritoneal fluid. Doripenem was stabilized by immediate mixing of the plasma or peritoneal fluid with 1M 3-morpholinopropanesulfonic acid buffer (pH 7.0) (1:1). Doripenem and an internal standard were detected by measuring their ultraviolet absorbance at 300 nm. The calibration curves for doripenem in human plasma and peritoneal fluid were linear from 0.05 to 100 microg/mL. For plasma, both the intra- and the interday precision were less than 3.41% (CV), and the accuracy was between 97.4 and 101.7% above 0.05 microg/mL. For peritoneal fluid, the intra- and the interday precision were less than 2.98% (CV), and the accuracy was between 94.4 and 103.9% above 0.05 microg/mL. The limit of detection was 0.02 microg/mL in both plasma and peritoneal fluid. The assay has been applied to the therapeutic drug monitoring of doripenem in both plasma and peritoneal fluid.  相似文献   

16.
A sensitive assay for the determination of unbound ertapenem in human plasma and bronchoalveolar lavage (BAL) was developed using ultrafiltration of plasma and BAL samples. A rapid HPLC method was used with ultraviolet detection set at a wavelength of 305 nm and a separation on a Prontosil AQ C18 column, with imipenem used as internal standard. This assay was linear over the concentration range of 0.5-100 microg/mL and 0.25-50 microg/mL in plasma and BAL, respectively. Limits of detection and quantitation were respectively 0.05 and 0.25 microg/mL. Validation data for accuracy and precision were CV<2.48 and 8.25%, accuracy in the range 98.1-104.2% and 102.2-108.4%, respectively, for intra and inter-day.  相似文献   

17.
A high-performance liquid chromatography (HPLC) method was developed to measure levels of d-threo-1-phenyl-2-palmitoylamino-3-morpholino-1-propanol (d-threo-PPMP) in mouse plasma and liver. d-threo-PPMP was measured by HPLC with a Luna Pheny-Hexyl column (5 microm, 250 mm x 4.6 mm) employing UV detection at 210 nm using a mobile phase of potassium phosphate buffer (20mM, pH 3.0)-acetonitrile in a 45:55 (v/v) ratio. d-threo-1-phenyl-2-pentadecanoylamino-3-morpholino-1-propanol (PC15MP) was employed as an internal standard (IS). The lower limit of quantitation (LLOQ) was 0.3 microg/ml. The assay was linear over a concentration range of 0.3-10 microg/ml, with acceptable precision and accuracy. Assayed in plasma, the intra- and inter-day validation for all coefficients of variation (R.S.D.%) were found less than 15%. The method was applied to samples from athymic (nu/nu) mice treated with d-threo-PPMP by intraperitoneal injection. d-threo-PPMP levels of approximately 10-20 microg/ml ( approximately 20-40 microM) in plasma and approximately 45 microg/g in liver were obtained. The present method can be used to quantify d-threo-PPMP in mice for bioavailability and dose-response studies.  相似文献   

18.
An HPLC system using a new, simple and rapid liquid-liquid extraction and high-performance liquid chromatography-diode array detector method (HPLC-DAD) detection was validated to determine tramadol concentration in rabbit plasma. The method described was applied to a pharmacokinetic study of intravenous tramadol injections in rabbits. The extraction with ethylacetate yielded good response. The recovery of tramadol from plasma averaged 90.40%. Serial plasma samples were obtained prior to, during and after completion of the infusion for determination of tramadol concentrations. Tramadol concentrations were measured using reverse-phase high-performance liquid chromatography and pharmacokinetic application with intravenous tramadol in rabbits revealed that tramadol followed one-compartment open model. Maximum plasma concentration (C(max)) and area under the plasma concentration-time curve (AUC) for tramadol were 14.3 microg mL(-1) and 42.2 microg h mL(-1), respectively. The method developed was successfully applied to a simple, rapid, specific, sensitive and accurate HPLC method for investigation of the pharmacokinetics of tramadol in rabbit plasma.  相似文献   

19.
20.
An isocratic and sensitive HPLC assay was developed allowing the determination of the new anticancer drug nilotinib (AMN107) in human plasma, urine, culture medium and cell samples. After protein precipitation with perchloric acid, AMN107 underwent an online enrichment using a Zirchrom-PBD precolumn, was separated on a Macherey-Nagel C18-HD column and finally quantified by UV-detection at 258 nm. The total run time is 25 min. The assay demonstrates linearity within a concentration range of 0.005-5.0 microg/ml in plasma (r(2)=0.9998) and 0.1-10.0 microg/ml in urine (r(2)=0.9913). The intra-day precision expressed as coefficients of variation ranged depending on the spiked concentration between 1.27-9.23% in plasma and 1.77-3.29% in urine, respectively. The coefficients of variation of inter-day precision was lower than 10%. Limit of detection was 0.002 microg/ml in plasma and 0.01 microg/ml in urine. The described method is stable, simple, economic and is routinely used for in vivo and in vitro pharmacokinetic studies of AMN107.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号