1.
Patients who receive prosthetic heart valve (PHV) implants require mandatory anticoagulation medication after implantation due to the thrombogenic potential of the valve. Optimization of PHV designs may facilitate reduction of flow-induced thrombogenicity and reduce or eliminate the need for post-implant anticoagulants. We present a methodology entitled Device Thrombogenicty Emulator (DTE) for optimizing the thrombo-resistance performance of PHV by combining numerical and experimental approaches. Two bileaflet mechanical heart valves (MHV) designs, St. Jude Medical (SJM) and ATS, were investigated by studying the effect of distinct flow phases on platelet activation. Transient turbulent and direct numerical simulations (DNS) were conducted, and stress loading histories experienced by the platelets were calculated along flow trajectories. The numerical simulations indicated distinct design dependent differences between the two valves. The stress loading waveforms extracted from the numerical simulations were programmed into a hemodynamic shearing device (HSD), emulating the flow conditions past the valves in distinct ‘hot-spot’ flow regions that are implicated in MHV thrombogenicity. The resultant platelet activity was measured with a modified prothrombinase assay, and was found to be significantly higher in the SJM valve, mostly during the regurgitation phase. The experimental results were in excellent agreement with the calculated platelet activation potential. This establishes the utility of the DTE methodology for serving as a test bed for evaluating design modifications for achieving better thrombogenic performance for such devices.  相似文献   

2.
Blood recirculating devices, such as ventricular assist devices and prosthetic heart valves, are burdened by thromboembolic complications requiring complex and lifelong anticoagulant therapy with its inherent hemorrhagic risks. Pathologic flow patterns occurring in such devices chronically activate platelets, and the optimization of their thrombogenic performance requires the development of flow-induced platelet activation models. However, existing models are based on empirical correlations using the well-established power law paradigm of constant levels of shear stress during certain exposure times as factors for mechanical platelet activation. These models are limited by their range of application and do not account for other relevant phenomena, such as loading rate dependence and platelet sensitization to high stress conditions, which characterize the dynamic flow conditions in devices. These limitations were addressed by developing a new class of phenomenological stress-induced platelet activation models that specifies the rate of platelet activation as a function of the entire stress history and results in a differential equation that can be directly integrated to calculate the cumulative levels of activation. The proposed model reverts to the power law under constant shear stress conditions and is able to describe experimental results in response to a diverse range of highly dynamic stress conditions found in blood recirculating devices. The model was tested in vitro under emulated device flow conditions and correlates well with experimental results. This new model provides a reliable and robust mathematical tool that can be incorporated into computational fluid dynamic studies in order to optimize design, with the goal of improving the thrombogenic performance of blood recirculating devices.  相似文献   

3.
The total cavopulmonary connection (TCPC) is a palliative cardiothoracic surgical procedure used in patients with one functioning ventricle that excludes the heart from the systemic venous to pulmonary artery pathway. Blood in the superior and inferior vena cavae (SVC, IVC) is diverted directly to the pulmonary arteries. Since only one ventricle is left in the circulation, minimizing pressure drop by optimizing connection geometry becomes crucial. Although there have been numerical and in-vitro studies documenting the effect of connection geometry on overall pressure drop, there is little published data examining the effect of SVC-IVC flow rate ratio on detailed fluid mechanical structures within the various connection geometries. We present here results from a numerical study of the TCPC connection, configured with various connections and SVC:IVC flow ratios. The role of major flow parameters: shear stress, secondary flow, recirculation regions, flow stagnation regions, and flow separation, was examined. Results show a complex interplay among connection geometry, flow rate ratio and the types and effects of the various flow parameters described above. Significant changes in flow structures affected local distribution of pressure, which in turn changed overall pressure drop. Likewise, changes in local flow structure also produced changes in maximum shear stress values; this may have consequences for platelet activation and thrombus formation in the clinical situation. This study sheds light on the local flow structures created by the various connections andflow configurations and as such, provides an additional step toward understanding the detailed fluid mechanical behavior of the more complex physiological configurations seen clinically.  相似文献   

4.
Bone loss is a serious health problem. In vivo studies have found that mechanical stimulation may inhibit bone loss as elevated strain in bone induces osteogenesis, i.e. new bone formation. However, the exact relationship between mechanical environment and osteogenesis is less clear. Normal strain is considered as a prime stimulus of osteogenic activity; however, there are some instances in the literature where osteogenesis is observed in the vicinity of minimal normal strain, specifically near the neutral axis of bending in long bones. It suggests that osteogenesis may also be induced by other or secondary components of mechanical environment such as shear strain or canalicular fluid flow. As it is evident from the literature, shear strain and fluid flow can be potent stimuli of osteogenesis. This study presents a computational model to investigate the roles of these stimuli in bone adaptation. The model assumes that bone formation rate is roughly proportional to the normal, shear and fluid shear strain energy density above their osteogenic thresholds. In vivo osteogenesis due to cyclic cantilever bending of a murine tibia has been simulated. The model predicts results close to experimental findings when normal strain, and shear strain or fluid shear were combined. This study also gives a new perspective on the relation between osteogenic potential of micro-level fluid shear and that of macro-level bending shear. Attempts to establish such relations among the components of mechanical environment and corresponding osteogenesis may ultimately aid in the development of effective approaches to mitigating bone loss.  相似文献   

5.
The present study addresses the question whether platelets are activated by mechanical stresses as they occur in pathologically accelerated blood flow. Their potential mechanoreceptive properties were tested by subjecting human platelets to defined fluid mechanical forces for periods of milliseconds. Platelet activation was assessed by quantitative morphology, revealing besides activated platelets, irreversibly ballooned, lytic platelets. However, this morphometrically documented "shear activation" of platelets can be suppressed almost completely by the addition of enzyme-substrate systems, capable of removing adenosine diphosphate from the suspending medium. This is in keeping with a recent study from our laboratory showing that the behaviour of lactic dehydrogenase as marker for platelet lysis and beta-thromboglobulin as release marker refuted earlier data, suggesting a direct activation of platelets by shear. It is concluded that former evidence of "shear induced platelet activation" must be interpreted as the consequence of lytic damage to a small proportion of platelets.  相似文献   

6.
The fundamental mechanisms that underlie platelet activation in atherothrombosis are still obscure. Oxidative stress is involved in central features of atherosclerosis. Platelet-derived microvesicles (PMVs) could be important mediators between oxidative stress and platelet activation. CD36 could be a receptor of PMVs, thus generating a PMV–CD36 complex. We aimed to investigate the detailed pathway by which oxidative damage contributes to platelet activation by the PMV–CD36 complex. We found that oxidized low-density lipoprotein stimulated the generation of PMVs. PMVs enhanced normal platelet activation, as assessed by the expression of integrin αIIbβ3, secretion of soluble P-selectin and platelet aggregation, but CD36-deficient platelets were not activated by PMVs. The function of the PMV–CD36 complex was mediated by the MKK4/JNK2 signaling axis. Meanwhile, PMVs increased the level of 8-iso-prostaglandin-F2α, a marker of oxidative stress, in a CD36- and phosphatidylserine-dependent manner. We concluded that PMVs are important mediators between oxidative stress and platelet activation. PMVs and CD36 may be effective targets for preventing platelet activation in cardiovascular diseases.  相似文献   

7.
Recently, it has been discovered that apoptosis of anucleate platelets can be induced by chemical agonists. Other studies demonstrated that mechanical forces (shear stresses) stimulate platelet activation and signaling in the absence of exogenous chemical stimuli. We analyzed whether shear stresses can trigger platelet apoptosis, a question that has not yet been studied. Using a cone-and-plate viscometer, we exposed human platelet-rich plasma to different shear stresses, ranging from physiologic arterial and arteriole levels (10-44 dyn/cm2) to pathologic high levels (117-388 dyn/cm2) occurring in stenotic vessels. We found that pathologic shear stresses induce not only platelet activation (P-selectin upregulation and GPIbalpha downregulation) but also trigger apoptosis events, including mitochondrial transmembrane potential depolarization, caspase 3 activation, phosphatidylserine exposure, and platelet shrinkage and fragmentation, whereas physiological shear stresses are not effective.This novel finding suggests that shear-induced platelet apoptosis can be mediated by mechanoreceptors, does not require nuclear participation, and may affect platelet clearance.  相似文献   

8.
The high incidence of thromboembolic complications of mechanical heart valves (MHV), primarily due to platelet activation by contact with foreign surfaces and by non-physiological flow patterns past the valve, still limits their success as permanent implants. The latter include elevated shear and turbulent stresses and shed vortices formed in the wake of the valve's leaflets during the deceleration phase, potentially entrapping activated and aggregated platelets. It is hypothesized that these flow patterns induce the formation of free emboli which are the source of cerebrovascular microemboli associated with MHV. Implicit to this hypothesis is that free emboli formation will be affected by the implantation technique employed and the valve orientation, as those will alter the flow characteristics past the valve and the interaction of the platelets with the flow. In this study, numerical simulations of turbulent pulsatile flow past a St. Jude Medical bi-leaflet MHV were conducted. Platelet shear histories were calculated along pertinent turbulent platelet trajectories, and the effect of a misaligned valve on platelet activation was quantified and compared to that of an aligned valve. It demonstrated that the combination of a tilted valve and subannularly sutured pledgets had an explicit detrimental effect on platelet activation, with the following entrapment of the platelets within the shed vortices of the wake leading to a significant increase of the thromboembolic potential of the valve. This numerical model depicted a viable course for free emboli formation, and indicated how the implantation technique may enhance the risk of cardioembolism.  相似文献   

9.
Blood flow can modulate vascular cell functions. We studied interactions between integrins and Flk-1 in transducing the mechanical shear stress due to flow. This application of a step shear stress caused Flk-1. Casitas B-lineage lymphoma (Cbl) activation (Flk-1. Cbl association, tyrosine phosphorylation of the Cbl-bound Flk-1, and tyrosine phosphorylation of Cbl) in bovine aortic endothelial cells (BAECs). The activation of integrins by plating BAECs on vitronectin or fibronectin also induced this Flk-1. Cbl activation. The shear-induced Flk-1. Cbl activation was blocked by inhibitory antibodies for alphavbeta3- or beta1-integrin, suggesting that it is mediated by integrins. Inhibition of Flk-1 by SU1498 also abolished this shear-induced Flk-1. Cbl activation. In contrast to the requirement of integrins for Flk-1. Cbl activation, the Flk-1 blocker SU1498 had no detectable effect on the shear-induced integrin activation, suggesting that integrins and Flk-1 play sequential roles in the signal transduction hierarchy induced by shear stress. Integrins are essential for the mechanical activation of Flk-1 by shear stress but not for the chemical activation of Flk-1 by VEGF.  相似文献   

10.
Hemodynamic shear is known to stimulate blood and endothelial cells and induce platelet activation. Many studies of shear-induced platelet stimulation have employed rotational viscometers in which secondary flow effects are assumed to be negligible. Shear induced platelet activation occurs at elevated shear rates where secondary flows may contribute a significant percentage of the total hydrodynamic force experienced by the sample. Elongational stress, one component of this secondary flow, has been shown to alter transmembrane ion flux in intact cell and the permeability of synthetic membrane preparations. Elongational flow also occurs in the vasculature at sites of elevated shear stress. Secondary flow components may contribute to platelet activation induced during shear stress application in rotational viscometry. A unique 'constrained convergence' elongational flow chamber was designed and fabricated to study platelet response to elongational stress exposure. The elongational flow chamber was capable of producing an elongation rate of 2.1 s-1 with a corresponding volume averaged shear rate of 58.33 s-1. Significant changes were observed in the total platelet volume distribution and measured response to added chemical antagonists after elongational stress exposure. The total platelet volume histogram shifted toward larger particle sizes, suggesting the formation of large aggregates as a result of elongational stress exposure. Platelets exposed to elongational stress demonstrated a dose dependent decrease in added ADP-induced aggregation rate and extent of aggregation.  相似文献   

11.
The hemostatic activity of blood shows a circadian variation with a higher frequency of acute coronary events in the morning. The thrombotic tendency of blood is influenced by many factors, including platelets. Diurnal changes of in vivo platelet activation were investigated by whole blood flow cytometry in 10 young healthy male volunteers using anti-GMP-140 (anti-α-granule membrane protein 140 kD) monoclonal antibody at 3h intervals from 06:00 to 24:00. We also studied circulating platelet aggregates to investigate whether there exists a similarity between the results of these methods. Results of flow cytometric analysis indicate that there is an increase in platelet activation during the period from 06:00 to 09:00. Platelet activation then decreases gradually during the period from noon to midnight. These changes are accompanied by a similar trend in circulating platelet aggregates. This suggests that GMP-140 expression on platelets is synchronized with or followed by platelet aggregate formation in vivo, and increased platelet activation may predispose individuals to thrombosis at this time.  相似文献   

12.
13.
The hemostatic activity of blood shows a circadian variation with a higher frequency of acute coronary events in the morning. The thrombotic tendency of blood is influenced by many factors, including platelets. Diurnal changes of in vivo platelet activation were investigated by whole blood flow cytometry in 10 young healthy male volunteers using anti-GMP-140 (anti-alpha-granule membrane protein 140 kD) monoclonal antibody at 3h intervals from 06:00 to 24:00. We also studied circulating platelet aggregates to investigate whether there exists a similarity between the results of these methods. Results of flow cytometric analysis indicate that there is an increase in platelet activation during the period from 06:00 to 09:00. Platelet activation then decreases gradually during the period from noon to midnight. These changes are accompanied by a similar trend in circulating platelet aggregates. This suggests that GMP-140 expression on platelets is synchronized with or followed by platelet aggregate formation in vivo, and increased platelet activation may predispose individuals to thrombosis at this time.  相似文献   

14.
Platelet activation under blood flow is thought to be critically dependent on the autologous secretion of soluble platelet agonists (chemical activators) such as ADP and thromboxane. However, recent evidence challenging this model suggests that platelet activation can occur independent of soluble agonist signalling, in response to the mechanical effects of micro-scale shear gradients. A key experimental tool utilized to define the effect of shear gradients on platelet aggregation is the murine intravital microscopy model of platelet thrombosis under conditions of acute controlled arteriolar stenosis. This paper presents a computational structural and hydrodynamic simulation of acute stenotic blood flow in the small bowel mesenteric vessels of mice. Using a homogeneous fluid at low Reynolds number (0.45) we investigated the relationship between the local hydrodynamic strain-rates and the severity of arteriolar stensosis. We conclude that the critical rates of blood flow acceleration and deceleration at sites of artificially induced stenosis (vessel side-wall compression or ligation) are a function of tissue elasticity. By implementing a structural simulation of arteriolar side wall compression, we present a mechanistic model that provides accurate simulations of stenosis in vivo and allows for predictions of the effects on local haemodynamics in the murine small bowel mesenteric thrombosis model.  相似文献   

15.
In the vasculature, reactive oxidant species, including reactive oxygen, nitrogen, or halogenating species, and thiyl, tyrosyl, or protein radicals may oxidatively modify lipids and proteins with deleterious consequences for vascular function. These biologically active free radical and nonradical species may be produced by increased activation of oxidant-generating sources and/or decreased cellular antioxidant capacity. Once formed, these species may engage in reactions to yield more potent oxidants that promote transition of the homeostatic vascular phenotype to a pathobiological state that is permissive for atherothrombogenesis. This dysfunctional vasculature is characterized by lipid peroxidation and aberrant lipid deposition, inflammation, immune cell activation, platelet activation, thrombus formation, and disturbed hemodynamic flow. Each of these pathobiological states is associated with an increase in the vascular burden of free radical species-derived oxidation products and, thereby, implicates increased oxidant stress in the pathogenesis of atherothrombotic vascular disease.  相似文献   

16.
Although it is established that endothelial cells can respond to external mechanical cues (e.g., alignment in the direction of fluid shear stress), the extent to which mechanical stress and strain applied via the endothelial cell substrate impact biomolecular and cellular processes is not well-understood. This issue is particularly important in the context of inflammation, vascular remodeling, and cancer progression, as each of these processes occurs concurrently with localized increases in strain and marked changes in molecules secreted by adjacent cells. Here, we systematically vary the level and duration of cyclic tensile strain applied to human dermal microvascular and bovine capillary endothelial cells via substrate deflection, and then correlate these cues with the secretion of extracellular matrix-degrading enzymes and a morphological transition from confluent monolayers to well-defined multicellular networks that resemble capillary tube-like structures. For a constant chemical environment, we find that super-physiological mechanical strain stimulates both endothelial cell secretion of latent matrix metalloprotease-2 and multicellular networks in a time- and strain-dependent manner. These results demonstrate coupling between the mechanical and biochemical states of microvascular endothelial cells, and indicate that elevated local stress may directly impact new capillary growth (angiogenesis) toward growing tumors and at capillary wall defect sites.  相似文献   

17.
Cardiac fibroblasts are exposed to both cyclic strain and interstitial fluid flow in the myocardium. The balance of these stimuli is affected by fibrotic scarring, during which the fibroblasts transition to a myofibroblast phenotype. The present study investigates the mechanisms by which cardiac fibroblasts seeded in three-dimensional (3D) collagen gels differentiate between strain and fluid flow. Neonatal cardiac fibroblast-seeded 3D collagen gels were exposed to interstitial flow and/or cyclic strain and message levels of collagens type I and III, transforming growth factor β1 (TGF-β1), and α-smooth muscle actin (α-SMA) were assessed. Flow was found to significantly increase and strain to decrease expression of myofibroblast markers. Corresponding immunofluorescence indicated that flow and strain differentially regulated α-SMA protein expression. The effect of flow was inhibited by exposure to losartan, an angiotensin II type 1 receptor (AT1R) blocker, and by introduction of shRNA constructs limiting AT1R expression. Blocking of TGF-β also inhibited the myofibroblast transition, suggesting that flow-mediated cell signaling involved both AT1R and TGF-β1. Reduced smad2 phosphorylation in response to cyclic strain suggested that TGF-β is part of the mechanism by which cardiac fibroblasts differentiate between strain-induced and flow-induced mechanical stress. Our experiments show that fluid flow and mechanical deformation have distinct effects on cardiac fibroblast phenotype. Our data suggest a mechanism in which fluid flow directly acts on AT1R and causes increased TGF-β1 expression, whereas cyclic strain reduces activation of smad proteins. These results have relevance to the pathogenesis and treatment of heart failure.  相似文献   

18.
Aortic valve (AV) disease is often characterized by the formation of calcific nodules within AV leaflets that alter functional biomechanics. In vitro, formation of these nodules is associated with osteogenic differentiation and/or increased contraction and apoptosis of AV interstitial cells (AVICs), leading to growth of calcium phosphate crystal structures. In several other cell types, increased intracellular Ca(2+) has been shown to be an important part in activation of osteogenic differentiability. However, elevated intracellular Ca(2+) is known to mediate cell contraction, and has also been shown to lead to apoptosis in many cell types. Therefore, a rise in intracellular Ca(2+) may precede cellular changes that lead to calcification, and fibroblasts similar to AVICs have been shown to exhibit increases in intracellular Ca(2+) in response to mechanical strain. In this study, we hypothesized that strain induces intracellular Ca(2+) accumulation through stretch-activated calcium channels. We were also interested in assessing possible correlations between intracellular Ca(2+) increases and apoptosis in AVICs. To test our hypothesis, cultured porcine AVICs were used to assess correlates between strain, intracellular Ca(2+), and apoptosis. Ca(2+) sensitive fluorescent dyes were utilized to measure real-time intracellular Ca(2+) changes in strained AVICs. Ca(2+) changes were then correlated with AVIC apoptosis using flow cytometric Annexin V apoptosis assays. These data indicate that strain-dependent accumulation of intracellular Ca(2+) is correlated with apoptosis in AVICs. We believe that these findings indicate early mechanotransductive events that may initiate AV calcification pathways.  相似文献   

19.
20.
The hemodynamic and the thrombogenic performance of two commercially available bileaflet mechanical heart valves (MHVs)--the ATS Open Pivot Valve (ATS) and the St. Jude Regent Valve (SJM), was compared using a state of the art computational fluid dynamics-fluid structure interaction (CFD-FSI) methodology. A transient simulation of the ATS and SJM valves was conducted in a three-dimensional model geometry of a straight conduit with sudden expansion distal the valves, including the valve housing and detailed hinge geometry. An aortic flow waveform (60 beats/min, cardiac output 4 l/min) was applied at the inlet. The FSI formulation utilized a fully implicit coupling procedure using a separate solver for the fluid problem (FLUENT) and for the structural problem. Valve leaflet excursion and pressure differences were calculated, as well as shear stress on the leaflets and accumulated shear stress on particles released during both forward and backward flow phases through the open and closed valve, respectively. In contrast to the SJM, the ATS valve opened to less than maximal opening angle. Nevertheless, maximal and mean pressure gradients and velocity patterns through the valve orifices were comparable. Platelet stress accumulation during forward flow indicated that no platelets experienced a stress accumulation higher than 35 dyne x s/cm2, the threshold for platelet activation (Hellums criterion). However, during the regurgitation flow phase, 0.81% of the platelets in the SJM valve experienced a stress accumulation higher than 35 dyne x s/cm2, compared with 0.63% for the ATS valve. The numerical results indicate that the designs of the ATS and SJM valves, which differ mostly in their hinge mechanism, lead to different potential for platelet activation, especially during the regurgitation phase. This numerical methodology can be used to assess the effects of design parameters on the flow induced thrombogenic potential of blood recirculating devices.  相似文献   