首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A europium‐sensitized fluorescence spectrophotometry method using an anionic surfactant, sodium dodecyl benzene sulphonate (SDBS), was developed for the determination of gatifloxacin (GFLX). The GFLX–Eu3+–SDBS system was studied and it was found that SDBS significantly enhanced the fluorescence intensity of the GFLX–Eu3+ complex (about 25‐fold). The optimal experimental conditions were determined as follows: excitation and emission wavelengths of 338 and 617 nm, pH 7.5, 3.0 × 10–6 mol/L europium(III), and 5.0 × 10–5 mol/L SDBS. The enhanced fluorescence intensity of the system (ΔIf) showed a good linear relationship with the concentration of GFLX over the range 1.0 × 10–8–8.0 × 10–7 mol/L with a correlation coefficient of 0.9990. The detection limit (S:N = 3) was determined as 1.0 × 10–9 mol/L. This method has been successfully applied for the determination of GFLX in pharmaceuticals and human urine/serum samples. Compared with most other methods reported, the rapid and simple procedure proposed here offered higher sensitivity, wider linear range and good stability. The luminescence mechanism of the system is also discussed in detail. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

2.
A rapid, simple, inexpensive and highly sensitive spectrofluorimetric method was developed for the determination of trace amounts of some tetracyclines (TCs), namely tetracycline hydrochloride (TCH), oxytetracycline hydrochloride (OTCH) and minocycline hydrochloride (MCH). Binding rhodamine B (RhB) to gold nanoparticles (Au NPs) resulted in quenching of the fluorescence of RhB by a resonance energy transfer (FRET) mechanism, with Au NPs as the energy acceptors. The presence of TCs caused the release of RhB molecules and recovered their fluorescence, and this was used as a basis for the quantitative determination of TCs. The reaction was monitored spectrofluorimetrically by measuring the increase in fluorescence of RhB at 572 nm starting 5 min after mixing the reagents in Tris buffer solution (pH 6.5). The effect of various experimental factors such as buffer type, pH, concentrations of the involved reagents and reaction time were studied to optimize the reaction conditions. Under optimum conditions, the calibration graphs were linear within the ranges 2.08 × 10?9–1.04 × 10?6 mol/L, 2.01 × 10?9–1.00 × 10?6 mol/L and 2.02 × 10?9–1.01 × 10?6 mol/L and detection limits (LODs) of 0.61 × 10?9, 0.32 × 10?9 and 0.66 × 10?9 mol/L were calculated for TCH, OTCH and MCH, respectively, with corresponding percent relative standard deviations (%RSDs) of 1.18, 1.21 and 1.54 (n = 5). The method was successfully applied to the determination of TCs in drinking water, human urine, bovine milk and breast milk samples. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

3.
A new sensitive quaternary photoluminescence enhancement system has been successfully developed to determine trace amounts of Eu3+ and Zn2+. The photoluminescence intensity of Eu ? N‐(o‐vanilin)‐1,8‐diaminonaphthalene systems was greatly increased by the addition of specific concentrations of 1, 10‐phenanthroline and Zn2+. The excitation and emission wavelengths were 274 and 617 nm, respectively. Under optimal system conditions, the photoluminescence intensity showed a linear response toward Eu3+ in the range of 5.0 × 10–6 ~ 2.0 × 10–5 M with a limit of detection (= 2.2 × 10–9 M) and the photoluminescence intensity of the system decreased linearly by increasing the Zn2+ concentration in the range of 5.0 × 10–8 ~ 1.0 × 10–6 M with a limit of detection (= 8.8 × 10–11 M). This system was successfully applied for the determination of trace amounts of Eu3+ in a high purity La2O3 matrix and in the synthetic rare earth oxide mixture, and of Zn2+ in a high purity Mg(NO3)2 · 6H2O matrix and in synthetic coexisting ionic matrixes. The energy transfer mechanism, photoluminescence enhancement of the system and interference of other lanthanide ions and common coexisting ions were also studied in detail. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

4.
Eu3+‐doped transparent glass ceramics containing MF2 (M = Ba, Ca, Sr) nanocrystals were fabricated using a melt–quenching method, and the resulting structures were studied using X‐ray diffraction. Levels 5D1 and 5D0 of Eu3+ ions were verified as thermally coupled levels using the fluorescence intensity ratio method. The fluorescence intensity ratios, optical temperature sensitivity and thermal quenching ratios of the transparent glass ceramics were studied as a function of temperature. With an increase in temperature, the relative sensitivity (S R) decreased sharply at first, then slowly increased, before finally decreasing. The minimum S R values of GCBaF2 (GCB), GCCaF2 (GCC) and GCSrF2 (GCS) were 2.8 × 10?4, 0.8 × 10?4 and 1.9 × 10?4 K?1 at 360, 269 and 319 K, respectively. Glass ceramics with an intense emission intensity can be used to convert the measured spectrum into temperature and may have an important role in temperature detectors.  相似文献   

5.
《Luminescence》2018,33(3):625-629
A simple, sensitive and efficient fluorescence method has been established for the quantitative analysis of bilirubin. The fluorometric determination method was based on the kinetic quenching of ruthenium(II) fluorescence. The quenching effect may be due to the complexation reaction of bilirubin with ruthenium(II). Therefore, the effects of ruthenium concentrations and different surfactants have been studied. Under the optimized experimental parameters, the fluorescence intensity decreased proportionally with the bilirubin concentration and linearity was established in the range of 3.3 × 10−7 to 3.0 × 10−4 M bilirubin. The detection limit calculated from the calibration graph was found to be 5.2 × 10−8 M. The relative standard deviation (RSD) of 10 consecutive measurements of 8.0 × 10−6 M bilirubin was 3.0%, while the recoveries of bilirubin in both human serum and urine samples were obtained in the range 94.0–99.5%. The interference study shows that the developed fluorescence based technique is fast, easy to carry out and shows negligible interference. The developed technique was successfully applied for the analysis of bilirubin in human urine and serum samples. All the experimental results and quality parameters confirmed the sensitivity and reproducibility of the proposed technique for bilirubin determination in human urine and serum samples .  相似文献   

6.
Yttrium‐sensitized fluorescence was used to develop a sensitive and simple spectrofluorimetric method for the determination of sparfloxacin. The method is based on the strong fluorescence of sparfloxacin after adding the fluorescence probe yttrium in buffer solution (pH = 8), and various factors influencing fluorescence were investigated. Under optimum conditions, the enhanced fluorescence intensity of the system showed a good linear relationship with the concentration of sparfloxacin over the range 8 × 10?7 to 1.4 × 10?5 mol L?1 with a correlation coefficient of 0.9997. The detection limit (S/N = 3) was determined as 9.01 × 10?8 mol L?1. The mechanism of the sensitizing effect of probe was discussed. This method has been successfully applied for the determination of sparfloxacin in pharmaceuticals, human urine and serum samples; the result obtained was satisfactory. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
A novel, rapid and sensitive chemiluminescence (CL) method for the determination of oxytetracycline hydrochloride (OTCH) is described in this paper. The presented method was based on the fact that OTCH could immensely enhance the CL of the reaction of cerium sulfate and tris(2,2‐bipyridyl) ruthenium (II) in acidic medium. Under optimal experimental conditions, CL intensity was favorably linear for OTCH in the range 5.0 × 10?7 to 5.0 × 10?5 g/ml, with a detection limit of 1.5 × 10?7 g/ml (S/N = 3). The relative standard detection was 4.76% for 5.0 × 10?6 g/ml (n = 11). This method was successfully applied to the analysis of OTCH in milk and egg white samples. According to the results of the kinetic curves for OTCH in the Ru(bipy)32+–Ce(SO4)2 CL system, together with CL and ultraviolet (UV)–visible spectra, the possible mechanism of the CL reaction is discussed briefly.  相似文献   

8.
A simple spectrofluorimetric method is described for the determination of DNA, based on its enhancement of the fluorescence intensity of prulifloxacin (PUFX)–Tb3+. The luminescence intensity of the PUFX–Tb3+ complex increased up to 10‐fold after adding DNA. The excitation and emission wavelengths were 345 and 545 nm, respectively. Under optimum conditions, variations in the fluorescence intensity showed a good linear relationship with the concentration of hsDNA in the range of 3.0 × 10‐9 to 1.0 × 10‐6 g/mL, with a correlation coefficient (R) of 0.997, and the detection limit was 2.1 × 10‐9 g/mL. The method was successfully applied to the determination of DNA in synthetic samples, and recoveries were in the range 97.3–102.0%. The mechanism of fluorescence enhancement of the PUFX–Tb3+ complex by DNA is also discussed. The mechanism may involve formation of a ternary complex mainly by intercalation binding together with weak electrostatic interaction, which will increase the energy transition from ligand to Tb3+, increasing the rigidity of the complex, and decreasing the radiationless energy loss through O–H vibration of the H2O molecule in the PUFX–Tb3+ compl+osed method is not only more robust and friendly to the environment, but also of relatively higher sensitivity. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
A post‐chemiluminescence (PCL) phenomenon was observed when chloramphenicol was injected into a mixture of luminol and potassium periodate after the chemiluminescence (CL) reaction of luminol–potassium periodate had finished. The possible reaction mechanism was proposed based on studies of the CL kinetic characteristics, the CL spectra, the fluorescence spectra and the UV‐vis absorption spectra of the related substances. Based on the PCL reaction, a rapid and sensitive method for the determination of chloramphenicol was established. The linear response range was 6.0 × 10?7–1.0 × 10?5 mol/L, with a correlation coefficient of 0.9986. The relative standard deviation (RSD) for 5.0 × 10?6 mol/L chloramphenicol was 2.3% (n = 11). The detection limit was 1.6 × 10?7 mol/L. The method has been applied to the determination of chloramphenicol in pharmaceutical samples with satisfactory results. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

10.
A novel flow‐injection chemiluminescence method was developed for the selective determination of human immunoglobulin G (IgG) in the presence of thiomersal by changing the flow rates of peristaltic pump. The study was based on the independence and additivity of the CL signals of human IgG and thiomersal in the galangin–potassium permanganate–polyphosphoric acid system. In meantime, two equations relating to the concentrations of mixing solutions of human IgG and thiomersal vs the CL intensity were established and solved, on the basis of which the content of thiomersal included in samples was simultaneously determined too. The enhanced CL intensity was in proportion to concerntrations in the range 8.0 × 10?7 to 8.0 × 10?5 g/mL for human IgG and 1.0 × 10?7 to 2.0 × 10?6 g/mL for thiomersal with the detection limits of 5.0 × 10?7 g/mL for human IgG and 6.0 × 10?8 g/mL for thiomersal, respectively. The relative standard deviation for 1.0 × 10?5 g/mL human IgG was 0.8% and for 2.0 × 10?7 g/mL thiomersal it was 2.0% (n = 10). The proposed method was applied to determine three synthetic samples with recoveries of 91.5–109.5%. In addition, the possible chemiluminescence mechanisms are discussed as well. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

11.
A sensitive time‐resolved luminescence method for the determination of amlodipine (AM) in methanol and in aqueous solution is described. The method is based on the luminescence sensitization of terbium (Tb3+) by formation of a ternary complex with AM in the presence of tri‐n‐octylphosphine oxide (TOPO) as co‐ligand, dodecylbenzenesulfate as surfactant and europium ion as a co‐luminescence reagent. The signal for Tb–AM–TOPO is monitored at λex = 242 nm and λem = 550 nm. Optimum conditions for the formation of the complex in aqueous system were 0.015 m Tris (hydroxylmethyl) amino methane buffer, pH 9.0, TOPO (1.0 × 10–4 m ), Eu3+ (2.0 × 10–7 m ), dodecylbenzenesulfate (0.14%) and 6.0 × 10–5 m of Tb3+, which allows the determination of 10–50 ppb of AM with a limit of detection of 1.2 ppb. The relative standard deviations of the method range between 0.1 and 0.2% indicated excellent reproducibility of the method. The proposed method was successfully applied for the assay of AM in pharmaceutical formulations and in plasma samples. Average recoveries of 98.5 ± 0.2% and 95.2 ± 0.2% were obtained for AM in tablet and plasma samples respectively. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
A terbium‐sensitized spectrofluorimetric method has been developed for determination of catecholamines such as norepinephrine (NE), epinephrine (EP) and dopamine (DA), using sodium dodecyl benzene sulphonate (SDBS). Fluorescence sensitization of terbium ions (Tb3+) by complexation with catecholamines in the presence of SDBS was observed. The fluorescence intensities of the Tb3+–catecholamine complexes were highly enhanced by introducing SDBS with an emission maximum at 545 nm after excitation at 290 nm. The conditions for the complex formation of Tb3+–catecholamine were investigated systematically and optimized to determine catecholamines in a serum sample. Under the optimum conditions, the fluorescence intensities of the Tb3+–catecholamine complexes were increased linearly with the concentration of NE, EP and DA over the ranges 2.5 × 10–10–1.0 × 10–8, 2.5 × 10–10–1.0 × 10–8 and 2.5 × 10–9–1.0 × 10–7 g/mL with correlation coefficients of 0.999, 0.999 and 0.9996, respectively. The limits of detection (3δ) of NE, EP and DA were found to be 4.6 × 10–11, 7.8 × 10–11 and 8.38 × 10–10 g/mL, respectively. Precision of the method was tested at the concentration level of 1.2 × 10?7 g/mL for five replicate measurements of NE, EP and DA, giving relative standard deviations (RSDs) of 1.41%, 1.23% and 1.89%, respectively. The interaction mechanism of the Tb3+–catecholamine complexes system was investigated and presented with ultraviolet absorption spectra. The proposed method has been applied for the quantitative determination of NE, EP and DA in a spiked serum sample and a pharmaceutical preparation sample. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

13.
Eu2+ single-doped SiO2 (SiO2/Eu2+) and Eu2+, Ag nanowires co-doped SiO2 (SiO2/Eu2+–Ag) luminescent nanomaterials were prepared by an efficient one-step sol–gel method. Their microstructure and optical properties were characterized, and the fluorescence enhancement of Eu2+ by Ag nanowires was investigated. The experimental results indicate that the average diameter of Ag nanowires doped is 12.5 nm, and the length–diameter ratio is 30. The Ag nanowires cannot only enhance the light absorption of SiO2/Eu2+ in the range of 230–350 nm, but also reduce the fluorescence lifetime of Eu2+. More importantly, the emission intensity is enhanced after doping Ag nanowires, and the red shift phenomenon of the emission spectrum is observed, red shift occurs between 10 and 56 nm. The highest fluorescence intensity is accessed under the Ag doping concentration of 0.10 %. Additionally, the emission of SiO2/Eu2+ with 0.10 % of Ag doping at 456 nm is 16 times stronger than that of pure SiO2/Eu2+. The present results indicate that the fluorescence enhancement is attributed to the local field enhancement and the increased radiative decay rates induced by Ag nanowires.  相似文献   

14.
The reduction of nuclear fast red (NFR) stain by sodium tetrahydroboron was catalyzed in the presence of silver ions (Ag+). The fluorescence properties of reduced NFR differed from that of NFR. The product showed fluorescence emission at 480 nm with excitation at 369 nm. Furthermore, the fluorescence intensity of the mixture increased strongly in the presence of Ag+ and Britton–Robinson buffer at pH 4.78. There was a good linear relationship between increased fluorescence intensity (ΔI) and Ag+ concentration in the range 5.0 × 10?9 to 5.0 × 10?8 M. The correlation coefficient was 0.998, and the detection limit (3σ/k) was 1.5 × 10?9 M. The colour of the reaction system changed with variation in Ag+ concentration over a wide range. Based on the colour change, a visual semiquantitative detection method for recognition and sensing of Ag+ was developed for the range 1.0 × 10?8 to 5.0 × 10?4 M, with an indicator that was visible to the naked eye. Therefore, a sensitive, simple method for determination of Ag+ was developed. Optimum conditions for Ag+ detection, the effect of other ions and the analytical application of Ag+ detection of synthesized sample were investigated.  相似文献   

15.
Hu Y  Li G  Zhang Z 《Luminescence》2011,26(5):313-318
In this paper, the novel trivalent copper–periodate complex {K5[Cu(HIO6)2], DPC} has been applied in a luminol‐based chemiluminescence (CL) reaction. Coupled with flow injection (FI) technology, the FI‐CL method was proposed for the determination of lincomycin hydrochloride. The CL reaction between luminol and DPC occurred in an alkaline medium. The CL intensity could be greatly enhanced by lincomycin hydrochloride. The relative CL intensity was proportional to the concentration of lincomycin hydrochloride in the range of 1 × 10?8 to 5 × 10?6 g mL?1 and the detection limit was at the 3.5 × 10?9 g mL?1 level. The relative standard deviation at 5 × 10?8 g mL?1 was 1.7% (n = 9). The sensitive method was successfully applied to the direct determination of lincomycin hydrochloride (ng mL?1) in serum. A possible mechanism of the lumonol–DPC CL reaction was discussed by the study of the CL kinetic characteristics and the spectra of CL reaction. The oxidability of DPC was studied by means of its electrochemical response. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

16.
Based on the inhibition effect of methimazole (MMI) on the reaction of luminol–H2O2 catalyzed by gold nanoparticles, a novel chemiluminescence (CL) method was developed for the determination of MMI. Under the optimum conditions, the relative CL intensity was linearly related to MMI concentration in the range from 5.0 × 10?8 to 5.0 × 10?5 mol L?1. The detection limit was 1.6 × 10?8 mol L?1 (S/N = 3), and the RSD for 6.0 × 10?6 mol L?1 MMI was 4.83 (n = 11). This method has high sensitivity, wide linear range, inexpensive instrumentation and has been applied to detect MMI in pharmaceutical tablets and pig serum samples. Furthermore, a possible reaction mechanism is discussed. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
A novel chemiluminescence method for the determination of 6‐mercaptopurine was established based on 6‐mercaptopurine inhibition of the chemiluminescence emission of potassium permanganate–thioacetamide–sodium hexametaphosphate system. The peak height was proportional to log 6‐mercaptopurine concentration in the range 7.0 × 10?10 to 1.0 × 10?7 g/mL and the detection limit was 1.9 × 10?11 g/mL (S/N = 3). The relative standard deviation was 1.5% for the determination of 8.0 × 10?8 g/mL 6‐mercaptopurine (n = 11). The proposed sensor was successfully applied to the analysis of 6‐mercaptopurine in human serum samples. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

18.
Two novel sensitive sequential injection chemiluminescence analysis and fluorescence methods for trovafloxacin mesylate detection have been developed. The methods were based on the enhancement effect of gold nanoparticles on luminol–ferricyanide–trovafloxacin and europium(III)–trovafloxacin complex systems. The optimum conditions for both detection methods were investigated. The chemiluminescence signal was emitted due to the enhanced effect of gold nanoparticles on the reaction of luminol–ferricyanide–trovafloxacin in an alkaline medium. The response was linear over a concentration range of 1.0 × 10–9 to 1.0 × 10–2 mol/L (%RSD = 1.3), (n = 9, r = 0.9991) with a detection limit of 1.7 × 10–10 mol/L (S/N = 3). The weak fluorescence intensity signal of the oxidation complex of europium(III)–trovafloxacin was strongly enhanced by gold nanoparticles and detected at λex = 330 and λem = 540 nm. Fluorescence detection enabled the determination of trovafloxacin mesylate over a linear range of 1.0 × 10–8 to 1.0 × 10–3 mol/L (%RSD = 1.2), (n = 6, r = 0.9993) with a detection limit of 3.3 × 10–9 mol/L. The proposed methods were successfully applied to the determination of the studied drug in its bulk form and in pharmaceutical preparations. The results were treated statistically and compared with those obtained from other reported methods. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

19.
Based on the fluorescence quenching of Terbium (III)‐sodium hexametaphosphate (Tb/SHMP) chelates in the presence chromate (III), a sensitive fluorimetric method was developed for the determination of trace amounts of chromium (III) in aqueous solutions. Under the optimum conditions, the linear calibration graph was obtained (R = 0.996). The linear range and detection limit of Cr (III) were 7.69 × 10?7 to 1.15 × 10?4 mol L?1 and 4.50 × 10?7 mol L?1, respectively. The proposed method had a wider linear range and was proved to be very sensitive, rapid and simple. The method was applied successfully to the determination of chromium (III) in the synthetic samples and real water samples. Moreover, the reaction mechanism was discussed through the fluorescence lifetime and proved to be dynamic quenching behavior. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

20.
A sensitive and selective fluorimetric sensor for the assay of ascorbic acid (AA) using silver nanoparticles as emission reagent was investigated. In this study, silver nanoparticles were prepared based on aqueous–gaseous phase reaction of silver nitrate solution and ammonia gas. The nanoparticles were water‐soluble, stable and had a narrow emission band. They were used as a fluorescence probe for the assay of ascorbic acid on its quenching effect on the emission of silver nanoparticles. The principal reason for quenching is likely to be a complexation between ascorbic acid and silver nanoparticles. The quenching mechanism was established by Stern–Volmer law. Under the optimum conditions, the quenched fluorescence intensity was linear with the concentration of ascorbic acid in the range of 4.1 × 10?6 to 1.0 ×10?4 m (= 0.9985) with a detection limit of 1.0 × 10?7 m . The RSD for repeatability of the sensor for the assay of ascorbic acid concentration of 3.0 × 10?5 and 4.0 × 10?6 m was found to be 1.5 and 1.3%, respectively. The proposed method was applied to the determination of ascorbic acid in vegetables and vitamin C tablets. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号