首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 421 毫秒
1.
A sensitive liquid chromatography-mass spectrometric (LC/MS) method for the quantification of schizandrin in rat plasma was developed and validated after solid-phase extraction (SPE). Chromatographic separation was achieved on a reversed-phase Shimadzu C(18) column with the mobile phase of acetonitrile-sodium acetate (10 micromol/L) and step gradient elution resulted in a total run time of about 11.7 min. The analytes were detected using an electrospray positive ionization mass spectrometry in the selected ion monitoring (SIM) mode. A good linear relationship was obtained in the concentration range studied (0.005-2.000 microg/mL) (r=0.9999). Lower limit of quantification (LLOQ) was 5 ng/mL and the lower limit of detection (LLOD) was 2 ng/mL using 100 microL plasma sample. Average recoveries ranged from 75.85 to 88.51% in plasma at the concentrations of 0.005, 0.100 and 1.000 microg/mL. Intra- and inter-day relative standard deviations were 5.95-12.93% and 3.87-14.53%, respectively. This method was successfully applied for the pharmacokinetic studies in rats.  相似文献   

2.
A bioanalytical method for the analysis of oseltamivir (OP) and its metabolite oseltamivir carboxylate (OC) in human plasma, saliva and urine using off-line solid-phase extraction and liquid chromatography coupled to positive tandem mass spectroscopy has been developed and validated. OP and OC were analysed on a ZIC-HILIC column (50 mm x 2.1 mm) using a mobile phase gradient containing acetonitrile-ammonium acetate buffer (pH 3.5; 10mM) at a flow rate of 500 microL/min. The method was validated according to published FDA guidelines and showed excellent performance. The lower limit of quantification for OP was determined to be 1, 1 and 5 ng/mL for plasma, saliva and urine, respectively and for OC was 10, 10 and 30 ng/mL for plasma, saliva and urine, respectively. The upper limit of quantification for OP was determined to be 600, 300 and 1500 ng/mL for plasma, saliva and urine, respectively and for OC was 10,000, 10,000 and 30,000 ng/mL for plasma, saliva and urine, respectively. The within-day and between-day precisions expressed as R.S.D., were lower than 5% at all tested concentrations for all matrices and below 12% at the lower limit of quantification. Validation of over-curve samples ensured that it would be possible with dilution if samples went outside the calibration range. Matrix effects were thoroughly evaluated both graphically and quantitatively. No matrix effects were detected for OP or OC in plasma or saliva. Residues from the urine matrix (most likely salts) caused some ion suppression for both OP and its deuterated internal standard but had no effect on OC or its deuterated internal standard. The suppression did not affect the quantification of OP.  相似文献   

3.
A sensitive, specific and rapid liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method was developed and validated for quantification of nalmefene in human plasma. An aliquot of 200 microL plasma sample was simply precipitated by 400 microL methanol. Separation of nalmefene and the internal standard hydromorphone from the interferences was achieved on a C(18) column followed by MS/MS detection. The analytes were monitored in the positive ionization mode with a TurboIonspray source. The method had a total chromatographic run time of 4.5 min and linear calibration curves over the concentration range of 10-5000 pg/mL. The lower limit of quantification (LLOQ) was 10 pg/mL. The intra- and inter-day precision was less than 10.1% determined from QC samples at concentrations of 30, 300 and 4500 pg/mL, and the accuracy was within +/-3.4%. As the method was more sensitive (10 times higher) than those reported previously, we investigated the pharmacokinetics of nalmefene in healthy volunteers after a single intravenous injection of low dose (30 microg) of nalmefene hydrochloride for the first time.  相似文献   

4.
A sensitive liquid chromatography-mass spectrometric (LC/MS) method for the quantification of ginsenoside Rd in dog plasma was developed and validated after solid-phase extraction (SPE).Chromatographic separation was achieved on a reversed-phase Cromosil C(18) column with the mobile phase of acetonitrile-ammonium chloride (500 micromol/L) and step gradient elution resulted in a total run time of about 5.5 min. The analytes were detected by using an electrospray negative ionization mass spectrometry in the selected ion monitoring (SIM) mode. A good linear relationship was obtained in the concentration range studied (0.005-2.500 microg/mL) (r=0.9998). Lower limit of quantification (LLOQ) was 5 ng/mL by using 500 microL plasma sample. Average recoveries ranged from 70.71 to 75.89% in plasma at the concentrations of 0.010, 0.100 and 2.500 microg/mL. Intra- and inter-day relative standard deviations were 8.49-11.71 and 5.71-16.48%, respectively. This method was successfully applied to the pharmacokinetic studies on dogs. The absolute bioavailability of Rd in dogs was 0.26%.  相似文献   

5.
A sensitive method for the determination of lapatinib (GW572016) in human plasma was developed using high-performance liquid chromatographic separation with tandem mass spectrometric detection. Plasma samples (100 microL) were prepared using solid phase extraction (SPE) columns, and 6.0 microL of the reconstituted eluate was injected onto a Phenomenex CuroSil-PFP 3 mu analytical column (50 mm x 2.0mm) with an isocratic mobile phase. Analytes were detected with a PE SCIEX API-365 LC-MS/MS system at unit (Q1) and low (Q3) resolution in positive multiple reaction monitoring mode (m/z 581 (precursor ion) to m/z 364 (product ion) for lapatinib). The mean recovery for lapatinib was 75% with a lower limit of quantification of 15 ng/mL (S/N=11.3, CV< or =14%). This method was validated over a linear range of 100-10,000 ng/mL, and results from a 5-day validation study demonstrated good within-day and between-day precision and accuracy. This method has been used to measure plasma lapatinib concentrations in a Phase I study in children with cancer.  相似文献   

6.
A selective and sensitive spectrofluorimetric method was developed and validated for the determination of amoxapine in human plasma and urine. The developed method is based on labeling with 5‐dimethylaminonaphthalene‐1‐sulfonyl chloride (dansyl chloride) and monitoring at 397 nm (excitation)/514 nm (emission). The method was validated for linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, recovery and robustness. The calibration curves were linear over a concentration range of 250–2500 and 50–1250 ng/mL for plasma and urine, respectively. The LOD values were calculated to be 13.31 and 13.17 ng/mL for plasma and urine, respectively. The proposed method was applied to study of amoxapine in human plasma and urine. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

7.
A screening procedure was developed for the identification and quantification of distigmine bromide in serum samples by using liquid chromatography (LC)-electrospray ionization (ESI)-mass spectrometry (MS). In this method, distigmine bromide was analyzed in 0.5 mL serum by using pancuronium bromide as the internal standard, and gradient elution was performed using a reversed-phase column and a mixture of 10 mM-ammonium formate and methanol as the mobile phase. A highly sensitive assay could be performed with simple solid phase extraction using a cation exchange cartridge column by carrying out selected ion monitoring analysis in the positive ion detection mode. The procedure was validated in terms of linearity (0.9973 at 2.5 ng/mL). The inter- and intra-day precisions (coefficient of variation; CV%) were <8.5% and < 9.7%, respectively. The analytes were evaluated for stability and were found to be stable in serum for 1 week at 4 degrees C and 4 weeks at -30 degrees C, and successfully applied to in the analysis of two overdose cases. This method is sensitive and useful for the detection, quantification, and confirmation of distigmine bromide in serum.  相似文献   

8.
A sensitive liquid chromatography-mass spectrometric (LC-MS) method for quantification of an active psychedelic hallucinogenic drugs (trimethoxyamphetamines) in human urine after solid-phase extraction (SPE) with C(18) cartridge was developed and validated. Chromatographic separation was achieved on reversed-phase Phenomenex 3.0 microm Polar Plus column (150 mm x 2.1 mm) with acetonitrile -0.2% acetic acid as mobile-phase and the step gradient elution resulted in a total run time of about 20 min. The analytes were detected by using an electrospray positive ionization mass spectrometry in selected ion monitoring (SIM) mode. In the evaluated concentration range (10-200 ng/mL) (R(2) > or = 0.998) a good linear relationship was obtained. The lower limits of detection (LLODs) and quantification (LLOQs) ranged from 4.26 to 9.12 ng/mL and from 13.18 to 29.22 ng/mL, respectively. Average recoveries ranged from 68.52 to 97.90% in urine at the concentrations of 25, 50 and 100 ng/mL. Intra- and inter-day relative standard deviations were 3.70-10.77% and 7.63-12.94%, respectively. This LC-MS method proved to be robust and reliable, and suitable for the use as a confirmation method in clinical urine drug testing.  相似文献   

9.
A LC-MS/MS method was validated for the determination of BA011FZ041, a styrylquinoline derivative. After addition of BA011FZ055 as internal standard (IS), the method involved solid phase extraction (SPE), LC separation with an ether-phenyl column and quantification by MS/MS after positive ESI. The calibration curve, ranging from 1 to 500 ng/mL was fitted to a 1/x-weighted quadratic regression model. Lower limit of quantification (LLOQ) was 1 ng/mL using 100 microL of plasma. Intra- and inter-assay precision and accuracy values were within the regulatory limits. The method was successfully applied to the determination of BA011FZ041 in rat plasma and PBMCs after i.v. dosing.  相似文献   

10.
A hydrophilic interaction liquid chromatography-time-of-flight mass spectrometry (HILIC-TOFMS) method for the quantification and confirmation of morphine (M), codeine (C), morphine-3-glucuronide (M3G), morphine-6-glucuronide (M6G) and codeine-6-glucuronide (C6G) is presented. The method was validated in terms of specificity, selectivity, extraction recovery, accuracy, repeatability, linearity and matrix effect. After a straightforward sample preparation by solid phase extraction (SPE) the compounds were analyzed directly without the need for hydrolysis, solvent transfer, evaporation or reconstitution. The HILIC technique provided good chromatographic separation which was critical for isomers M3G and M6G. The analytes were detected after electrospray ionization (ESI) in positive mode with mass accuracies below 2 mDa using a 5-mDa window. A measurement range of 50-5000 ng/ml was applied for calibration using deuterated analogs as internal standards. The precision of the method was 5.7% and 10.2% (RSD) within and between days, respectively. The applicability of the method was demonstrated with authentic urine samples known to contain codeine and/or morphine and their intact glucuronide conjugates. Identification of the analytes was based on in-source collision induced dissociation (ISCID), applying three diagnostic ions with accurate mass.  相似文献   

11.
A precise, sensitive and high throughput liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of trazodone (TRZ) and its primary metabolite, m-chlorophenylpiperazine (mCPP), in human plasma was developed and validated. The analytes and the internal standard-nefazodone were extracted from 500 microL aliquots of human plasma via liquid-liquid extraction in n-hexane. Chromatographic separation was achieved in a run time of 2.5 min on a Betabasic cyano column (100 mm x 2.1 mm, 5 microm) under isocratic conditions. Detection of analytes and IS was done by tandem mass spectrometry, operating in positive ion and multiple reaction monitoring (MRM) acquisition mode. The protonated precursor to product ion transitions monitored for TRZ, mCPP and IS were m/z 372.2-->176.2, 197.2-->118.1 and 470.5-->274.6 respectively. The method was fully validated for its sensitivity, selectivity, accuracy and precision, matrix effect, stability study and dilution integrity. A linear dynamic range of 10.0-3000.0 ng/mL for TRZ and 0.2-60.0 ng/mL for mCPP was evaluated with mean correlation coefficient (r) of 0.9986 and 0.9990 respectively. The intra-batch and inter-batch precision (%CV) across five validation runs (LLOQ, lower limit of quantitation; LQC, low quality control; MQC, middle quality control; HQC, high quality control and ULOQ, upper limit of quantitation) was < or =8.4% for both the analytes. The method was successfully applied to a bioequivalence study of 100mg trazodone tablet formulation in 36 healthy Indian male subjects under fasting and fed conditions.  相似文献   

12.
Dihydroartemisinin (DHA) is a sesquiterpene used in the world as an antimalarial. To evaluate the pharmacokinetics of dihydroartemisinin in rats, a sensitive and specific liquid chromatography/tandem mass spectrometric (LC-MS/MS) method was developed and validated for the quantitation of dihydroartemisinin in rat plasma. For detection, a Sciex API 4000 LC-MS/MS with a TurboIonSpray ionization (ESI) inlet in the positive ion-multiple reaction monitoring (MRM) mode was used. The plasma samples were pre-treated by a simple liquid-liquid extraction with diethyl ether. The statistical evaluation for this method reveals excellent linearity, accuracy and precision for the range of concentrations 0.2-100.0 ng/mL. The method had a lower limit of quantification (LLOQ) of 0.2 ng/mL for beta-dihydroartemisinin in 100 microL of plasma. The method was successfully applied to the characterization of the pharmacokinetic profile of beta-dihydroartemisinin in rats after oral administration.  相似文献   

13.
A simple, selective and sensitive isocratic HPLC method with triple quadrupole mass spectrometry detection has been developed and validated for simultaneous quantification of zopiclone and its metabolites in human plasma. The analytes were extracted using solid phase extraction, separated on Symmetry shield RP8 column (150 mm x 4.6 mm i.d., 3.5 microm particle size) and detected by tandem mass spectrometry with a turbo ion spray interface. Metaxalone was used as an internal standard. The method had a chromatographic run time of 4.5 min and linear calibration curves over the concentration range of 0.5-150 ng/mL for both zopiclone and N-desmethyl zopiclone and 1-150 ng/mL for zopiclone-N-oxide. The intra-batch and inter-batch accuracy and precision evaluated at lower limit of quantification and quality control levels were within 89.5-109.1% and 3.0-14.7%, respectively, for all the analytes. The recoveries calculated for the analytes and internal standard were > or = 90% from spiked plasma samples. The validated method was successfully employed for a comparative bioavailability study after oral administration of 7.5 mg zopiclone (test and reference) to 16 healthy volunteers under fasted condition.  相似文献   

14.
Methadone and buprenorphine are two of the drugs most frequently used for abstinence from illicit opioids and in the treatment of pain. A sensitive and selective high-performance liquid chromatographic method with diode array detection for the simultaneous determination of methadone, buprenorphine and norbuprenorphine has been developed. Separation of the three analytes was obtained by using a reversed-phase column (C8, 250mmx4.6mm i.d., 5microm) and a mobile phase composed of 40% phosphate buffer containing triethylamine, 50% methanol and 10% acetonitrile (final apparent pH 6.0). Loxapine was used as the internal standard. An accurate pre-treatment procedure of biological samples was developed, using solid-phase extraction with C8 cartridges (100mg, 1mL) and needing small amounts of plasma or urine (300microL). The calibration curves were linear over a working range of 10.0-1500.0ng/mL for methadone and of 5.0-500.0ng/mL for buprenorphine and norbuprenorphine in both matrices. The limit of quantitation (LOQ) and the limit of detection (LOD) were 1.0 and 0.4ng/mL for methadone and 0.5 and 0.2ng/mL for both buprenorphine and norbuprenorphine, respectively. The method was successfully applied to the analysis of plasma and urine samples from patients undergoing treatment with these drugs. Precision and accuracy results were satisfactory and no interference from endogenous or exogenous compounds was found. The method is suitable for the simultaneous determination of methadone and buprenorphine in human plasma and urine for therapeutic drug monitoring purposes.  相似文献   

15.
Current analytical methods used for screening drugs and their metabolites in biological samples from victims of drug-facilitated sexual assault (DFSA) or other vulnerable groups can lack sufficient sensitivity. The application of liquid chromatography, employing small particle sizes, with tandem mass spectrometry (MS/MS) is likely to offer the sensitivity required for detecting candidate drugs and/or their metabolites in urine, as demonstrated here for ketamine. Ultra-performance liquid chromatography-mass spectrometry (UPLC-MS/MS) was performed following extraction of urine (4 mL) using mixed-mode (cation and C8) solid-phase cartridges. Only 20 microL of the 250 microL extract was injected, leaving sufficient volume for other assays important in DFSA cases. Three ion transitions were chosen for confirmatory purposes. As ketamine and norketamine (including their stable isotopes) are available as reference standards, the assay was additionally validated for quantification purposes to study elimination of the drug and primary metabolite following a small oral dose of ketamine (50 mg) in 6 volunteers. Dehydronorketamine, a secondary metabolite, was also analyzed qualitatively to determine whether monitoring could improve retrospective detection of administration. The detection limit for ketamine and norketamine was 0.03 ng/mL and 0.05 ng/mL, respectively, and these compounds could be confirmed in urine for up to 5 and 6 days, respectively. Dehydronorketamine was confirmed up to 10 days, providing a very broad window of detection.  相似文献   

16.
We developed a sensitive, selective and precise method for measuring herbicide metabolites in human urine. Our method uses automated liquid delivery of internal standards and acetate buffer and a mixed polarity polymeric phase solid phase extraction of a 2 mL urine sample. The concentrated eluate is analyzed using high-performance liquid chromatography-tandem mass spectrometry. Isotope dilution calibration is used for quantification of all analytes. The limits of detection of our method range from 0.036 to 0.075 ng/mL. The within- and between-day variation in pooled quality control samples range from 2.5 to 9.0% and from 3.2 to 16%, respectively, for all analytes at concentrations ranging from 0.6 to 12 ng/mL. Precision was similar with samples fortified with 0.1 and 0.25 ng/mL that were analyzed in each run. We validated our selective method against a less selective method used previously in our laboratory by analyzing human specimens using both methods. The methods produced results that were in agreement, with no significant bias observed.  相似文献   

17.
A simple, rapid and sensitive ultra performance liquid chromatography tandem mass spectrometry method was developed and fully validated for the quantitative determination of seven amphetamines and metabolites in urine. The method was validated for selectivity, linearity, LOQ, LOD, imprecision, bias, analyte and processed sample stability, matrix effect, recovery, carryover and dilution integrity. A classic liquid–liquid extraction with ethyl acetate was used as sample preparation procedure. The compounds were separated on an Acquity UPLC HSS C18 column in 6.8 min. The linear dynamic range was established from 25 to 500 ng/mL. The limit of quantification was fixed to the lowest calibrator level and the limit of detection ranged from 0.125 to 2.5 ng/mL. The method presented an excellent intra- and inter-assay imprecision and bias (<10.7%) at each measured concentration of two external quality controls (QC) and three “in house” QC. No matrix effects were observed and good recoveries (>70%) were obtained for all the compounds. No carryover was observed after the analysis of high concentrated samples (8000 ng/mL). The method was subsequently applied to authentic samples.  相似文献   

18.
A highly sensitive and specific LC-MS method was developed and validated for the quantification of digoxin in human plasma and urine using d5-dihydrodigoxin as internal standard (IS). The assay procedure involved extraction of digoxin and IS from human plasma with chloroform-isopropanol (95:5, v/v). Chromatogrphic separation was achieved on a Spherisorb ODS2 column using a gradient mobile phase with 5 mmol/L ammonium acetate in water with 1% acetic acid and acetonitrile. The mass spectrometer was operated in the selected ion monitoring mode using the respective [M+K](+) ions, m/z 819.4 for digoxin and m/z 826.4 for IS. The method was proved to be accurate and precise at linearity range of 0.12-19.60 ng/mL in plasma with a correlation coefficient (r(2)) of >or=0.9968 and 1.2-196.0 ng/mL in urine. The limit of quantification achieved with this method was 0.12 ng/mL in plasma and 1.2 ng/mL in urine. The intra- and inter-assay precision and accuracy values were found to be within the assay variability limits as per the FDA guidelines. The developed assay method was successfully applied to a pharmacokinetic study in human volunteers following intravenous administration of digoxin.  相似文献   

19.
A sensitive method for the determination of Cloretazine (VNP40101M) and its metabolite (VNP4090CE) with an internal standard (ISTD) in human plasma was developed using high-performance liquid chromatographic separation with tandem mass spectrometric detection. Acidified plasma samples (500 microL) were prepared using solid phase extraction (SPE) columns, and 25 microL of the reconstituted sample was injected onto an Ascentis C18 HPLC column (3 microm, 5 cmx2.1 mm) with an isocratic mobile phase. Analytes were detected with an API-3000 LC-MS/MS System at unit (Q1) and low (Q3) resolution in negative multiple reaction monitoring mode: m/z 249.0 (precursor ion) to m/z 114.9 (product ion) for both Cloretazine (at 3.64 min) and VNP4090CE (at 2.91 min), and m/z 253.0 (precursor ion) to m/z 116.9 (product ion) for the ISTD. The mean recovery for Cloretazine (VNP40101M) and its metabolite (VNP4090CE) was greater than 87% with a lower limit of quantification of 1.0 ng/mL for Cloretazine (S/N=9.7, CV相似文献   

20.
A sensitive, rapid liquid chromatographic-electrospray ionization mass spectrometric method for determination of erythromycylamine in human plasma was developed and validated. Erythromycylamine in plasma (0.2 mL) was extracted with ethyl acetate, the organic phase was transferred to another clear 1.5 mL Eppendorf tube and evaporated to dryness under gentle nitrogen stream at 45 degrees C, and the residue was dissolved in 100 microL of mobile phase. The samples were separated using a Thermo Hypersil HyPURITY C18 reversed-phase column (150 mm x 2.1 mm I.D., 5 microm). A mobile phase containing 10 mM of ammonium acetate (pH = 6.4)-acetonitrile-methanol (50:10:40, v/v/v) was used isocratically eluting at a flow rate of 0.2 mL/min. Erythromycylamine and its internal standard (IS), midecamycin, were measured by electrospray ion source in positive selective ion monitoring mode. The method demonstrated that good linearity ranged from 4.5 to 720 ng/mL with r = 0.9997. The limit of quantification for erythromycylamine in plasma was 4.5 ng/mL with good accuracy and precision. The mean extraction recovery of the method was higher than 75.1% and 72.7% for erythromycylamine and IS, respectively. The intra-day and inter-day precision ranged from 5.2% to 6.4% and 5.6-9.3% (relative standard deviation, RSD), respectively. The established method has been successfully applied to a bioequivalence study of two dirithromycin formulations for 18 healthy volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号