首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
Analytical methods for the determination of melagatran (H 319/68) in biological samples by liquid chromatography (LC)-positive electrospray ionization mass spectrometry using multiple reaction monitoring are described. Melagatran in plasma was isolated by solid-phase extraction on octylsilica, either in separate extraction tubes or in 96-well plates. Absolute recovery of melagatran from plasma was >92%. Melagatran and the internal standard, H 319/68 D2 13C2, were separated from other sample components by LC utilizing a C18 stationary phase and a mobile phase comprising 35% acetonitrile and 0.08% formic acid in 0.0013 mol/l ammonium acetate solution. After dilution, urine was injected directly onto the LC column and subjected to gradient LC. The relative standard deviation was 1-5% for concentrations above the limit of quantification, which was estimated for plasma at 10 or 25 nmol/l for sample volumes of 500 or 200 microl, respectively, and 100 nmol/l for urine.  相似文献   

2.
A high-performance liquid chromatographic method using liquid-liquid extraction was developed for the determination of 1-(3-fluoro-4-hydroxy-5-mercaptomethyl-tetrahydrofuran-2-yl)-5-methyl-1H-pyrimidine-2,4-dione (l-FMAUS; I) in rat plasma and urine. A 100 microl aliquot of distilled water containing l-cysteine (100 mg/ml) was added to a 100 microl aliquot of biological sample. l-Cysteine was employed to protect binding between the 5'-thiol of I and protein in the biological sample. After vortex-mixing for 30s and adding a 50 microl aliquot of the mobile phase containing the internal standard (10 microg/ml of 3-aminophenyl sulfone), 1 ml of ethyl acetate was used for extraction. After vortex-mixing, centrifugation, and evaporating the ethyl acetate, the residue was reconstituted with a 100 microl aliquot of the mobile phase. A 50 microl aliquot was injected onto a C(18) reversed-phase column. The mobile phases, 50 mM KH(2)PO(4) (pH = 2.5):acetonitrile (85:15, v/v) for rat plasma and 50 mM KH(2)PO(4) (pH 2.5):acetonitrile:methanol (85:10:5, v/v/v) for urine samples, were run at a flow-rate of 1.2 ml/min. The column effluent was monitored by an ultraviolet detector set at 265 nm. The retention times for I and the internal standard were approximately 9.7 and 12.5 min, respectively, in plasma samples and the corresponding values in urine samples were 16.8 and 14.9 min. The quantitation limits of I in rat plasma and urine were 0.1 and 0.5 microg/ml, respectively.  相似文献   

3.
A gas chromatographic method with nitrogen–phosphorus detection involving a solid–liquid extraction phase was developed and validated for the simultaneous quantification of 3,4-methylenedioxymethamphetamine (MDMA) and 3,4-methylenedioxyamphetamine (MDA) in plasma. A modification of this method was validated for the analysis of MDMA, MDA, 4-hydroxy-3-methoxymethamphetamine (HMMA) and, 4-hydroxy-3-methoxyamphetamine (HMA) in urine. Under the analytical conditions described, the limits of detection in plasma and urine were less than 1.6 μg/l and 47 μg/l, respectively, for all the compounds studied. Good linearity was observed in the concentration range evaluated in plasma (5–400 μg/l) and urine (100–2000 μg/l) for all compounds tested. The recoveries obtained from plasma were 85.1% and 91.6% for MDMA and MDA, respectively. Urine recoveries were higher than 90% for MDMA and MDA, 74% for HMMA, and 64% for HMA. Methods have been successfully used in the assessment of plasma and urine concentrations of MDMA and its main metabolites in samples from clinical studies in healthy volunteers.  相似文献   

4.
Astragaloside IV is a novel cardioprotective agent extracted from the Chinese medical herb Astragalus membranaceus (Fisch) Bge. This agent is being developed for treatment for cardiovascular disease. Further development of Astragaloside IV will require detailed pharmacokinetic studies in preclinical animal models. Therefore, we established a sensitive and accurate high performance liquid chromatography (HPLC) coupled with tandem mass spectrometry (LC/MS/MS) quantitative detection method for measurement of Astragaloside IV levels in plasma, urine as well as other biological samples including bile fluid, feces and various tissues. Extraction of Astragaloside IV from plasma and other biological samples was performed by Waters OASIS(trade mark) solid phase extraction column by washing with water and eluting with methanol, respectively. An aliquot of extracted residues was injected into LC/MS/MS system with separation by a Cosmosil C18 5 microm, 150 mm x 2.0 mm) column. Acetonitrile:water containing 5 microM NaAc (40:60, v/v) was used as a mobile phase. The eluted compounds were detected by tandem mass spectrometry. The average extraction recoveries were greater than 89% for Astragaloside IV and digoxin from plasma, while extraction recovery of Astragaloside IV and digoxin from tissues, bile fluid, urine and fece ranged from 61 to 85%, respectively. Good linearity (R2>0.9999) was observed throughout the range of 10-5000 ng/ml in 0.5 ml rat plasma and 5-5000 ng/ml in 0.5 ml dog plasma. In addition, good linearity (R2>0.9999) was also observed in urine, bile fluid, feces samples and various tissue samples. The overall accuracy of this method was 93-110% for both rat plasma and dog plasma. Intra-assay and inter-assay variabilities were less than 15.03% in plasma. The lowest quantitation limit of Astragaloside IV was 10 ng/ml in 0.5 ml rat plasma and 5 ng/ml in 0.5 ml dog plasma, respectively. Practical utility of this new LC/MS/MS method was confirmed in pilot pharmacokinetic studies in both rats and dogs following intravenous administration.  相似文献   

5.
Existing methods to determine neferine, a bisbenzylisoquinline alkaloid, either have no internal standard or lack selectivity, or take longer time. Here an improved reverse-phase high-performance liquid chromatographic (RP-HPLC) method was established in biological samples. The extraction recovery was 90.9% for neferine at concentration level of 0.2 microg/ml and 77.7% for dauricine (the internal standard) at 5 microg/ml in dog plasma, respectively. The linear quantification range of the method was 25-2000 ng/ml in dog plasma, with linear correlation coefficients greater than 0.999. The intra-day and inter-day relative standard deviations (R.S.D.s) for neferine at 50, 200 and 1000 ng/ml levels in dog plasma fell in the range of 3.0-5.4% and 4.3-9.5%, respectively. The RP-HPLC method was successfully applied to a pharmacokinetics study, in which experimental dogs received a single dose of neferine (5 mg/kg i.v. or 10 mg/kg p.o.). The pharmacokinetic result was presented.  相似文献   

6.
A sensitive method has been developed for the determination of the vasoactive compounds cinnarizine and flunarizine in plasma, urine and milk samples from man and animals. The procedure involves the extraction of the drugs and their internal standard from the biological samples at alkaline pH, back-extraction into sulphuric acid and re-extraction into the organic phase (heptane—isoamyl alcohol).The analyses were carried out by gas chromatography using a nitrogen-selective thermionic specific detector. The detection limit was 0.5 ng/ml of biological fluid and extraction recoveries were sufficiently high (87–94%).The method was applied to plasma samples from bioavailability studies of both cinnarizine and flunarizine in healthy volunteers, and to plasma, urine and milk samples from flunarizine-treated dogs.  相似文献   

7.
A simple and sensitive method was developed for the quantification of amikacin in human plasma and urine samples. The method involves centrifugation of body fluid plasma after dilution with an ethanol/sodium carbonate mixture, and then an aliquot of the supernatant is directly injected into the chromatograph. After separation on a reversed-phase C18 column (runtime 20 min), aminoglycoside is detected on the basis of its complex formation reaction with Cu(II), the catalyst of the luminol/hydrogen peroxide chemiluminescence system. Using a volume of 500 microl biological sample, linearity is established over the concentration range 0.15-2.0 microg/ml and the limit of detection (LOD) is ca. 50 microg/l in plasma or urine. The intra-day and inter-day precision (measured by relative standard deviation, R.S.D.%) are always less than 9%, and relative recoveries are found to be over 92%.  相似文献   

8.
A gas chromatography-mass spectrometry (GC-MS) method was developed for the quantitative analysis of free amino acids as their propyl chloroformate derivatives in biological fluids. Derivatization with propyl chloroformate is carried out directly in the biological samples without prior protein precipitation or solid-phase extraction of the amino acids, thereby allowing automation of the entire procedure, including addition of reagents, extraction and injection into the GC-MS. The total analysis time was 30 min and 30 amino acids could be reliably quantified using 19 stable isotope-labeled amino acids as internal standards. Limits of detection (LOD) and lower limits of quantification (LLOQ) were in the range of 0.03-12 microM and 0.3-30 microM, respectively. The method was validated using a certified amino acid standard and reference plasma, and its applicability to different biological fluids was shown. Intra-day precision for the analysis of human urine, blood plasma, and cell culture medium was 2.0-8.8%, 0.9-8.3%, and 2.0-14.3%, respectively, while the inter-day precision for human urine was 1.5-14.1%.  相似文献   

9.
A method for the determination of piracetam in human plasma and urine by liquid chromatography with absorbance detection at 206 nm and isocratic elution is proposed. The assay involved a liquid-liquid extraction into hexane-2-propanol at pH 9.2. The calibration graphs were linear in the range 3–40 mg/l in plasma and 100–2000 mg/l in urine. Bias was negligible and coefficients of variation were less than 10% throughout the working range except at 100 mg/l in urine. The limits of quantification were 3 mg/l in plasma and 100 mg/l in urine. The assay was reliably used for pharmacokinetic studies in humans after administration of 800 mg of piracetam per os.  相似文献   

10.
The paper describes a method for the sensitive and selective determination of zearalenone and its metabolites in urine, plasma and faeces of horses by high performance liquid chromatography and atmospheric pressure chemical ionisation (APCI) mass spectrometry (MS). While only one step sample clean-up by an immunoaffinity column (IAC) was sufficient for plasma samples, urine and faeces samples had to be prepared by a combination of a solid-phase extraction (SPE) and an immunoaffinity column. The method allows the simultaneous determination of zearalenone and all of its metabolites; alpha-zearalenol, beta-zearalenol, alpha-zearalanol, beta-zearalanol and zearalanone. Dideuterated zearalanone was used as internal standard for quantification and the study of the matrix effect. Recovery rates between 56 and slightly above 100% were achieved in urine samples, and more than 80% in plasma and faeces samples. The limits of detection ranged from 0.1-0.5 microg/l or microg/kg, the limits of quantification from 0.5-1.0 microg/l or microg/kg. The practical use of the method is demonstrated by the analysis of spiked and naturally contaminated urine, plasma and faeces of horses.  相似文献   

11.
A simple and rapid analytical method is presented for the determination of amitraz in canine plasma samples using solid-phase microextraction (SPME) and gas chromatography with thermionic specific detection (GC-TSD). The best conditions for the SPME procedure were: direct extraction on a polydimethlysiloxane (PDMS) fiber with 100-microm film thickness; 400 µl of sample plasma matrix modified with 4 ml sodium borate solution (0.01 mol l(-1), pH 6.5); extraction temperature 70 degrees C, with stirring at 2500 rpm for 45 min. The method was linear between 20 and 400 ng ml(-1) with regression coefficients corresponding to 0.998 and coefficient of the variation of the points of the calibration curve lower than 15%. The lowest limit of quantification (LOQ) for amitraz in plasma was 20 ng ml(-1). This LOQ was determined as the lowest concentration on the calibration curve in which the coefficient of variation was lower than 15%. The proposed method was applied to determine amitraz concentrations in canine plasma to look for toxicity after treatment with amitraz in a dipping bath.  相似文献   

12.
This article describes two methods for the determination of 1,4-butanediol and gamma-hydroxybutyrate in human plasma and urine using capillary gas chromatography. For 1,4-butanediol, plasma or urine samples (500 microl) were extracted by protein precipitation whereas for gamma-hydroxybutyrate, plasma or urine samples (500 microl) were extracted and derivatised with BF3-butanol. The compounds were separated on a Supelcowax-10 column and detection was achieved using a flame ionization detector. The methods are linear over the specific ranges investigated, accurate (with a percentage of the nominal concentration <109.8%) and showed intra-day and inter-day precision within the ranges of 5.0-12.0 and 7.0-10.1%, respectively. No interferences were observed in plasma and urine from hospitalized patients.  相似文献   

13.
In the present work, a method was developed and optimized aiming to determinate the herbicides paraquat (PQ) and diquat (DQ) in human plasma and urine samples. An initial procedure of chemical reduction of the analytes by adding NaBH4 directly in the buffered samples (pH 8.0) was performed. This procedure was necessary to convert the quaternary ammonium substances into more volatile compounds for gas chromatographic analysis. The reduction compounds were extracted with C18 cartridges (solid-phase extraction). Ethyl paraquat (EPQ) was used as internal standard (IS). Gas chromatography-mass spectrometry (GC-MS) was used to identify and quantify the analytes in selected ion monitoring (SIM) mode. The limits of detection were 0.05 mg/l for both PQ and DQ. By using the weighted least squares linear regression (1/x1/2 for plasma and 1/y for urine), the accuracy of the analytical method was improved at the lower end of the calibration curve (from 0.1 to 50 mg/l; r>0.98). This method can be readily utilized as an important tool to confirm the suspicion of PQ and/or DQ poisoning and evaluate the extent of the intoxication.  相似文献   

14.
A sensitive high-performance liquid chromatographic (HPLC) method with ultraviolet absorption detection (292 nm) was developed and validated for the determination of the new phosphodiesterase V inhibitor, DA-8159 (DA), in human plasma and urine. A single step liquid-liquid extraction procedure using ethyl ether was performed to recover DA and the internal standard (sildenafil citrate) from 1.0 ml of biological matrices combined with 200 microl of 0.1M sodium carbonate buffer. A Capcell Pak C18 UG120 column (150 mm x 4.6 mm I.D., 5 microm) was used as a stationary phase and the mobile phase consisted of 30% acetonitrile and 70% 20mM potassium phosphate buffer (pH 4.5) at a flow rate of 1.0 ml/min. The lower limit for quantification was 5 ng/ml for plasma and 10 ng/ml for urine samples. Within- and between-run accuracy and precision were < or =15 and < or =10%, respectively, in both plasma and urine samples. The recovery of DA from human plasma and urine was greater than 70%. Separate stability studies showed that DA is stable under the conditions of analysis. This validated assay was used for the pharmacokinetic analysis of DA during a phase I, rising dose study.  相似文献   

15.
A gas chromatographic–mass spectrometric method was developed for the enantioselective analysis of levetiracetam and its enantiomer (R)-α-ethyl-2-oxo-pyrrolidine acetamide in dog plasma and urine. A solid-phase extraction procedure was followed by gas chromatographic separation of the enantiomers on a chiral cyclodextrin capillary column and detection using ion trap mass spectrometry. The fragmentation pattern of the enantiomers was further investigated using tandem mass spectrometry. For quantitative analysis three single ions were selected from the enantiomers, enabling selected ion monitoring in detection. The calibration curves were linear from 1 μM to 2 mM for plasma samples and from 0.5 mM to 38 mM for urine samples. In plasma and urine samples the inter-day precision, expressed as relative standard deviation was around 10% in all concentrations. Selected ion monitoring mass spectrometry is suitable for quantitative analysis of a wide concentration range of levetiracetam and its enantiomer in biological samples. The method was successfully applied to a pharmacokinetic study of levetiracetam and (R)-α-ethyl-2-oxo-pyrrolidine acetamide in a dog.  相似文献   

16.
A reversed-phase high-performance liquid chromatographic method is described for the simultaneous determination of the skeletal muscle relaxant dantrolene and its metabolites, 5-hydroxydantrolene and nitro-reduced acetylated dantrolene (F 490), in plasma and urine of man and dog. The substances are detected spectrophotometrically at 375 nm. The detection limits are 0.02 mg/l. A preliminary extraction step into a chloroform—butanol mixture is required for the plasma samples. The method is suitable for pharmacokinetic studies of dantrolene.  相似文献   

17.
A sensitive and highly automated high-performance liquid chromatography (HPLC) column-switching method has been developed for the simultaneous determination of the active metabolite III and its prodrug II, both derivatives of the oral platelet inhibitor Ro 48-3657 (I), in plasma and urine of man and dog. Plasma samples were deproteinated with perchloric acid (0.5 M), while urine samples could be processed directly after dilution with phosphate buffer. The prepared samples were injected onto a pre-column of a HPLC column switching system. Polar plasma or urine components were removed by flushing the precolumn with phosphate buffer (0.1 M, pH 3.5). Retained compounds (including II and III) were backflushed onto the analytical column, separated by gradient elution and detected by means of UV detection at 240 nm. The limit of quantification for both compounds was 1 ng/ml (500 μl of plasma) and 25 ng/ml (50 μl of urine) for plasma and urine, respectively. The practicability of the new method was demonstrated by the analysis of about 6000 plasma and 1300 urine samples from various toxicokinetic studies in dogs and phase 1 studies in man.  相似文献   

18.
A high-performance liquid chromatographic (HPLC) procedure has been developed for the quantification of L-365,260 (I), a cholecystokinin and gastrin receptor antagonist, in dog and rat plasma. The method involves liquid—liquid extraction and HPLC with ultraviolet detection. Standard curves were linear over the range 7.5–2000 ng/ml for rat and dog plasma. The method is reproducible and reliable with a detection limit of 7.5 ng/ml in biological fluids. The mean coefficients of variation for concentrations within the range of the standard curve range were 3.84 and 2.56%, respectively, for intra-day analysis and 4.48 and 4.26%, respectively, for inter-day analysis. Application of the development was successfully demonstrated by quantifying the concentration of I in both dog and rat plasma samples following an intravenous or oral dose of 5 mg/kg I.  相似文献   

19.
A modified specific, sensitive and reproducible chiral gas chromatographic (GC) method for the resolution and quantification of ethosuximide enantiomers in urine and plasma was developed. The samples were extracted by liquid-liquid extraction, using diethylether and the enantiomers were separated and quantified on a chiral gas chromatographic column (25QC2 / CYDEX- beta 0.25). The method involved the use of GC/MS instrumentation for the acquisition of data in the electron impact selective-ion monitoring mode, collecting ions characteristic of both ethosuximide and alpha, alpha - dimethyl - beta - methylsuccinimide, the internal standard and of mass-to-charge ratio (m/z) exactly equal to 55 and 70 units. The limit of quantitation of the method was 2.5 microg/ml for both urine and plasma with both enantiomers. The method proved to be linear, precise and reproducible in the 5-300 microg/ml concentration range for urine samples and in the 10-250 microg/ml concentration range for plasma samples. Future research work envisaged the application of this method in pharmacokinetic and pharmacodynamic studies.  相似文献   

20.
F2-isoprostanes (F2-iPs) comprise four classes of isomers produced non-enzymatically by free radical attack on arachidonic acid, a component of the cell membrane. This paper describes a new method for the quantification of F2-isoprostanes in urine samples from thoroughly diagnosed Alzheimer's disease (AD) patients. The sample pretreatment consisted of liquid extraction of 900 microl urine with diethyl ether, its subsequent evaporation, and finally, reconstitution in 50 microl water. Of this, 20 microl was injected into a HPLC system with a 15 mm x 1 mm porous graphitic carbon column coupled to a triple quadrupole mass spectrometer running in negative electrospray ionization mode. The F2-isoprostanes were separated in 15 min using a linear solvent gradient comprising water, methanol, acetonitrile and ammonium hydroxide at a pH of 9.5. The average recovery obtained was approximately 75%. The limit of detection (3S/N) was calculated for iPF2alpha-III to be 0.7 pg injected on column, corresponding to 0.1 nM. The average level of iPF2alpha was 241 +/- 163 pg/mg creatinine in the urine samples from AD patients (average +/- standard deviation). The corresponding control values were 216 +/- 101 pg/mg creatinine, i.e. no statistically significant difference was noticed. No correlation pattern specific to Alzheimer's disease was revealed by principal component analysis of the isoprostane peaks obtained either. The results from this study support earlier findings that levels of peripheral isoprostanes are not increased in patients with Alzheimer's disease.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号