首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 312 毫秒
1.
A novel derivatization method employing 1,2-dimethylimidazole-4-sulfonyl chloride (DMISC) to improve the mass spectrometric response for phenolic compounds in liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS) and tandem mass spectrometry (LC-ESI-MS/MS) is described. Several environmentally relevant compounds, including chloro-, aryl- and alkylphenols, steroidal estrogens, and hydroxy-polycyclic aromatic hydrocarbons (OHPAHs), were selected to evaluate this technique. A facile derivatization procedure employing DMISC results in dimethylimidazolesulfonyl (DMIS) derivatives that are stable in aqueous solution. These DMIS derivatives produced intense [M+H](+) ions in positive-ion LC-ESI-MS. The product ion spectra of the [M+H](+) ions of simple phenols were dominated by ions representing the DMIS and dimethylimidazole moieties, whereas product ion spectra of the DMIS derivatives of OHPAHs with three or more fused aromatic rings showed prominent ArO(+) ions, the relative intensity of which increased with the number of rings. The DMIS derivatives of the selected phenolic compounds showed excellent chromatographic properties. To substantiate the utility of derivatization with DMISC, an analytical method employing enzyme hydrolysis, solid phase extraction, derivatization with DMISC, and analysis by LC-ESI-MS/MS with multiple reaction monitoring for determination in human urine of 1-hydroxypyrene, a widely used biomarker for the assessment of human exposure to PAHs, was developed and validated.  相似文献   

2.
The applicability of LC–MS/MS in precursor ion scan mode for the detection of urinary stanozolol metabolites has been studied. The product ion at m/z 81 has been selected as specific for stanozolol metabolites without a modification in A- or N-rings and the product ions at m/z 97 and 145 for the metabolites hydroxylated in the N-ring and 4-hydroxy-stanozolol metabolites, respectively. Under these conditions, the parent drug and up to 15 metabolites were found in a positive doping test sample. The study of a sample from a chimeric uPA-SCID mouse collected after the administration of stanozolol revealed the presence of 4 additional metabolites. The information obtained from the product ion spectra was used to develop a SRM method for the detection of 19 compounds. This SRM method was applied to several doping positive samples. All the metabolites were detected in both the uPA-SCID mouse sample and positive human samples and were not detected in none of the blank samples tested; confirming the metabolic nature of all the detected compounds. In addition, the application of the SRM method to a single human excretion study revealed that one of the metabolites (4ξ,16ξ-dihydroxy-stanozolol) could be detected in negative ionization mode for a longer period than those commonly used in the screening for stanozolol misuse (3′-hydroxy-stanozolol, 16β-hydroxy-stanozolol and 4β-hydroxy-stanozolol) in doping analysis. The application of the developed approach to several positive doping samples confirmed the usefulness of this metabolite for the screening of stanozolol misuse. Finally, a tentative structure for each detected metabolite has been proposed based on the product ion spectra measured with accurate masses using UPLC–QTOF MS.  相似文献   

3.
After intragastric administration of 100 mumol kg-1 [14C]felodipine to rats eight urinary metabolites were isolated. Batch extraction at pH 2.2 and semipreparative reversed-phase liquid chromatography were used for trace enrichment of the metabolites. Trimethylsilylation followed by transesterification with diazomethane blocked the carboxylic acid and alcohol groups selectively before gas chromatography/mass spectrometry (GC/MS) in the electron impact (EI) mode. Deuterated derivatives of the metabolites and chemical ionization measurements added complementary structural information. All metabolites reported in this study were formed from oxidized felodipine by ester hydrolysis. Hydroxylation of the pyridine methyl group represented an important metabolic pathway and metabolites oxidized to the corresponding carboxylic acids were detected as well. Lactone formation from hydroxy acid metabolites in urine as a possible analytical artefact is discussed.  相似文献   

4.
A liquid chromatography-electrospray ionisation-tandem mass spectrometry (LC-ESI-MS/MS) method for the quantification of major chlorpyrifos (CP) metabolites, i.e. diethyl thiophosphate (DETP), diethyl phosphate (DEP), and 3,5,6-trichloro-2-pyridinol (TCP), in human urine was developed. Simultaneous separation of the parent compound and its primary biotransformation products was achieved within 20 min in gradient elution mode employing a mixed-mode reversed-phase/weak anion exchange (RP/WAX) separation principle. The analytical method was developed for a toxicokinetic study of an acute poisoning incidence with a CP containing pesticide formulation. An initial mass spectrometric screening performed with unprocessed urine samples revealed that CP is not excreted unchanged by the kidney. Hence, the quantitative assay was validated for DETP (quantifier transition: m/z 169-->95, qualifier transition: m/z 169-->141), DEP (m/z 153-->79, 153-->125), and TCP (m/z 196-->35, 198-->35) taking dibutyl phosphate (DBP) (m/z 209-->79, 209-->153) as internal standard. Clean-up of urine samples prior to LC-ESI-MS/MS analysis was carried out by a liquid-liquid extraction step with a mixture of ethylacetate and acetonitrile (70:30; v/v). Linearity was observed between 0.25 and 75 mgL(-1), and the signal-to-noise ratio at 0.25 mgL(-1) was better than six for the individual analytes. Recoveries, precision, and accuracies were all adequate across the validated range of 1-75 mgL(-1) for the present toxicological case study.  相似文献   

5.
Rapid resolution liquid chromatography/tandem multi-stage mass spectrometry (RRLC-MS(n)) and rapid resolution liquid chromatography/tandem mass spectrometry (RRLC/MS/MS) methods were developed for the identification and quantification of ergosterol and its metabolites from rat plasma, urine and faeces. Two metabolites (ERG1 and ERG2) were identified by RRLC/MS(n). The concentrations of the ergosterol were determined by RRLC/MS/MS. The separation was performed on an Agilent Zorbax SB-C18 with the mobile phase consisting of methanol and water (containing 0.1% formic acid). The detection was carried out by means of atmospheric pressure chemical ionization mass spectrometry in positive ion mode with multiple reaction monitoring (MRM). Linear calibration curves were obtained in the concentration range of 7-2000, 6-2000 and 8-7500 ng/mL for plasma, urine and faecal homogenate, respectively. The intra- and inter-day precision values (RSD) were below 10%. The method was applied to the pharmacokinetic properties and elimination pathway of ergosterol in rats.  相似文献   

6.
The applicability of LC–MS/MS in precursor ion scan mode for the detection of urinary stanozolol metabolites has been studied. The product ion at m/z 81 has been selected as specific for stanozolol metabolites without a modification in A- or N-rings and the product ions at m/z 97 and 145 for the metabolites hydroxylated in the N-ring and 4-hydroxy-stanozolol metabolites, respectively. Under these conditions, the parent drug and up to 15 metabolites were found in a positive doping test sample. The study of a sample from a chimeric uPA-SCID mouse collected after the administration of stanozolol revealed the presence of 4 additional metabolites. The information obtained from the product ion spectra was used to develop a SRM method for the detection of 19 compounds. This SRM method was applied to several doping positive samples. All the metabolites were detected in both the uPA-SCID mouse sample and positive human samples and were not detected in none of the blank samples tested; confirming the metabolic nature of all the detected compounds. In addition, the application of the SRM method to a single human excretion study revealed that one of the metabolites (4ξ,16ξ-dihydroxy-stanozolol) could be detected in negative ionization mode for a longer period than those commonly used in the screening for stanozolol misuse (3′-hydroxy-stanozolol, 16β-hydroxy-stanozolol and 4β-hydroxy-stanozolol) in doping analysis. The application of the developed approach to several positive doping samples confirmed the usefulness of this metabolite for the screening of stanozolol misuse. Finally, a tentative structure for each detected metabolite has been proposed based on the product ion spectra measured with accurate masses using UPLC–QTOF MS.  相似文献   

7.
A solvent system that extracts a maximum number of metabolites belonging to diverse chemical classes from complex biofluids, such as plasma, may offer useful inputs to understand the metabolic and physiological state of an individual. The present study compared seven solvent systems for extraction of metabolites from plasma. The extracts were analyzed by mass spectrometry (MS) and MS/MS (MS2) using a quadrupole time-of-flight liquid chromatography/MS system in positive and negative modes of ionization. Metabolites with molecular mass below 400 were identified using Human Metabolome Database MS2 and MS search interfaces. The acetone/isopropanol (2:1) system yielded promising results in positive ionization mode, as the maximum number of MS and MS2 features was detected in the extract. It was found to be superior in extraction of various classes of metabolites, especially organic acids, nucleosides and nucleoside derivatives, and heterocyclic molecules. Glycerophosphocholines in the mass range of 400–700 were found to be efficiently extracted by the methanol/chloroform/water (8:1:1) system. In negative mode as well, the maximum number of MS2 features was detected in methanol/chloroform/water and acetone/isopropanol extracts. The fingerprints of molecular features obtained in the negative and positive modes differed from each other to a significant extent.  相似文献   

8.
A gas chromatography–mass spectrometry (GC–MS) procedure was developed for the detection of 4-hydroxycoumarin anticoagulants and their metabolites in urine as part of a systematic toxicological analysis procedure for acidic drugs and poisons after extractive methylation. The part of the phase-transfer catalyst remaining in the organic phase was removed by solid-phase extraction on a diol phase. The compounds were separated by capillary GC and identified by computerized MS in the full scan mode. Using mass chromatography with the ions m/z 291, 294, 295, 309, 313, 322, 324, 336, 343 and 354, the possible presence of 4-hydroxycoumarin anticoagulants and/or their metabolites could be indicated. The identity of positive signals in such mass chromatograms was confirmed by comparison of the peaks underlying full mass spectra with the reference spectra recorded during this study. This method allowed the detection of therapeutic concentrations of phenprocoumon and warfarin in human urine samples. In absence of human urine, acenocoumarol, coumachlor, coumatetrayl, pyranocoumarin (cyclocumarol) could be detected only in rat urine.  相似文献   

9.
In this study, a method using liquid chromatography triple quadrupole mass spectrometry (LC/MS/MS) is described for the analysis of the plant growth regulator chlormequat (CCC) in human urine. Analysis was carried out using selected reaction monitoring (SRM) in the positive ion mode. [(2)H(4)] labeled CCC as internal standard (IS) was used for quantification of CCC. The limit of detection (LOD) was determined to 0.1 ng/mL. The method was linear in the range 0.3-800 ng/mL urine and had a within-run precision of 4-9%. The between-run precision was determined at urine levels of 7.0 and 31 ng/mL and found to be 5 and 6% respectively. The reproducibility was 3-6%. To validate CCC as a biomarker of exposure, the method was applied in a human experimental oral exposure to CCC. Two healthy volunteers received 25 μg/kg b.w. CCC in a single oral dose followed by urine sampling for 46 h post-exposure. The CCC was estimated to follow a first order kinetic and a two compartment model with an elimination half-life of 2-3h and 10-14 h respectively. One hundred 24h urine samples were collected from non-occupationally exposed individuals in the general population in southern Sweden. All samples had detectable levels above the LOD 0.1 ng/mL urine. The median levels were 4 ng/mL of CCC in unadjusted urine. The levels found in the population samples are several magnitudes lower than those found in the experimental exposure, which corresponds to an oral exposure of 50% of the ADI for CCC.  相似文献   

10.
Uric acid (UA) can be directly converted to allantoin enzymatically by uricase in most mammals except humans or by reaction with superoxide. UA can react directly with nitric oxide to generate 6-aminouracil and with peroxynitrite to yield triuret; both of these metabolites have been identified in biological samples. We now report a validated high-performance liquid chromatography and tandem mass spectrometry method for the determination of these urinary UA metabolites. Urine samples were diluted 10-fold, filtered and directly injected onto HPLC for LC–MS/MS analysis. The urinary metabolites of UA were separated using gradient HPLC. Identification and quantification of UA urinary metabolites was performed with electrospray in positive ion mode by selected-reaction monitoring (SRM). Correlation coefficients were 0.991–0.999 from the calibration curve. The intra- and inter-day precision (R.S.D., %) of the metabolites ranged from 0.5% to 13.4% and 2.5–12.2%, respectively. In normal individuals (n = 21), urinary allantoin, 6-aminouracil and triuret, were 15.30 (±8.96), 0.22 (±0.12), and 0.12 (±0.10) μg/mg of urinary creatinine (mean (±S.D.)), respectively. The new method was used to show that smoking, which can induce oxidative stress, is associated with elevated triuret levels in urine. Thus, the method may be helpful in identifying pathways of oxidative stress in biological samples.  相似文献   

11.
[1,2,3,4-13C]cortisol was i.v. administered to two sisters aged 11 yr (patient I) and 3 yr (patient II) who suffer from 17 alpha-hydroxylase deficiency. This is the first time that the cortisol production rate (CPR) in patients with 17 alpha-hydroxylase deficiency has been measured with a stable labelled tracer using the urinary method. The urine was collected for 3 days. High-performance liquid chromatography (HPLC) of approximately 100 ml urine extracts was carried out to isolate the small amount of cortisol metabolites excreted. The cortisol metabolites were oxidized to 11-oxo-aetiocholanolone. The isotope dilution in the methyl oxime tert-butyldimethylsilyl ether derivatives was measured by selected ion monitoring gas chromatography/mass spectrometry (GC/MS). The CPR calculated from tetrahydrocortisone (THE) and the cortolones was 765 and 536 nmol/day, respectively in patient I. The CPR in patient II was only calculated from THE and was 62 nmol/day. If radioactive labelled cortisol had been used, much larger quantities of urine would have been needed for isolation of sufficient mass of metabolites, even then purification may have been difficult. Steroid profiling of 1 ml urine samples by GC and identification by GC/MS revealed high concentrations of pregnenolone, progesterone, 11 beta-hydroxy progesterone and corticosterone metabolites. Tetrahydrocorticosterone and 5 alpha-tetrahydrocorticosterone were found in urine at elevated excretions of 2.5 and 5.7, 0.9 and 2.0 mumols/24 h, in patients I and II respectively. No cortisol metabolites were detected by routine GC or GC/MS as the low amounts excreted co-eluted with the relatively abundant corticosterone metabolites.  相似文献   

12.
A sensitive and specific high-performance liquid chromatographic assay with electrospray ionization mass spectrometry detection (LC-ESI-MS) has been developed and validated for the identification and quantification of the novel anticholinergic drug phencynonate in rat blood and urine. The sample pretreatment involves basification and iterative liquid-liquid extraction with ethyl ether-dichloromethane (2:1, v/v) solution, followed by LC separation and positive electrospray ionization mass spectrometry detection. The chromatography was on BetaBasic-18 column (150 mm x 2.1mm i.d., 3 microm). The mobile phase was composed of methanol-water (85:15, v/v), containing 0.5 per thousand formic acid, which was pumped at a flow-rate of 0.2 ml/min. Thiencynonate was selected as the internal standard (IS). Simultaneous MS detection of phencynonate and IS was performed at m/z 358.4 (phencynonate), m/z 364 (thiencynonate), and the selected reaction ion monitoring (SRM) of the two compounds was at 156. Phencynonate eluted at approximately 5.25 min, thiencynonate eluted at approximately 5.10 min and no endogenous materials interfered with their measurement. Linearity was obtained over the concentration range of 1-100 ng/ml in rat blood and 1-500 ng/ml in rat urine. The lower limit of quantification (LLOQ) was reproducible at 1 ng/ml in both of rat blood and urine. The precision measured was obtained from 2.92 to 9.76% in rat blood and 4.17 to 9.76% in rat urine. Extraction recoveries were in the range of 69.57-79.49% in blood and 56.85-64.86% in urine. This method was successfully applied to the identification and quantification of phencynonate in pharmacokinetic studies.  相似文献   

13.
A multi-residues method using pressurized liquid extraction (PLE) and liquid chromatography combined with mass spectrometry (LC-MS/MS) has been developed for determination of eight glucocorticoids (prednisone, prednisolone, hydrocortisone, methylprednisolone, dexamethasone, betamethasone, beclomethasone, fludrocortisone) in muscle of swine, cattle, and sheep. Parameters affecting PLE extraction including extraction solvent, extraction temperature, extraction pressure and extraction cycles were optimized. The optimized method employed 11 ml extraction cells, hexane-ethyl acetate (50:50, v/v) as extraction solvent, 1500 psi of extraction pressure and 50°C of extraction temperature. The samples were detected by LC-ESI-MS/MS in negative mode with selected reaction monitoring (SRM) mode. The recovery of glucocorticoids spiked at levels of 0.5-6 μg kg(-1) ranged from 70.1% to 103.1%; the between-day relative standard deviations were no more than 9.6%. The limits of quantification were 0.5-2 μg kg(-1) in muscle. The results demonstrated that the method is simple, fast, robust, and suitable for identification and quantification of glucocorticoids residues in foods of animal origin.  相似文献   

14.
A rapid, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed for identification of potassium dehydroandrographolidi succinas and its metabolites in rat urine. Five male rats were administrated a single dose (100 mg/kg) of potassium dehydroandrographolidi succinas by i.v. injection. The urine were sampled from 0 to 24 h and purified by using Oasis? HLB extraction cartridge, then the purified urine samples were separated on a reversed-phase C18 column with a linear gradient and detected by an on-line MS detector. Identification and structural elucidation of the metabolites were performed by comparing their changes in molecular mass (Δm) and MS/MS spectra with those of the parent drug. Seven metabolites and the parent drug were found in rat urine. All these metabolites were reported for the first time.  相似文献   

15.
16.
Sulfonyl chlorides substituted with functional groups having high proton affinity can serve as derivatization reagents to enhance the sensitivity for steroidal estrogens in liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). The most commonly used reagent for derivatization of estrogens for LC-ESI-MS/MS is dansyl chloride. In this study, we compared dansyl chloride, 1,2-dimethylimidazole-4-sulfonyl (DMIS) chloride, pyridine-3-sulfonyl (PS) chloride, and 4-(1H-pyrazol-1-yl)benzenesulfonyl (PBS) chloride for derivatization of 17beta-estradiol (E2) prior to LC-ESI-MS/MS. The product ion spectra of the dansyl and DMIS derivatives were dominated by ions representing derivatization reagent moieties. In contrast, the product ion spectrum of the PS derivative of E2 and, to a lesser extent, the PBS derivative, showed analyte-specific fragment ions. Derivatization with PS chloride was therefore chosen for further investigation. The product ion spectrum of the PS derivative of E2 showed intense ions at m/z 272, assigned to the radical E2 cation, and at m/z 350, attributed to the loss of SO(2) from the [M+H](+) ion. Third-stage mass spectrometry of the PS derivative of E2 with isolation and collisional activation of the m/z 272 ion resulted in steroid C and D ring cleavages analogous to those observed in electron ionization mass spectrometry. The product ion spectra of the PS derivatives of estrone, 17alpha-ethinylestradiol, equilin, and equilenin showed similar estrogen-specific ions. Using derivatization with PS chloride, we developed an LC-ESI-MS/MS method with multiple reaction monitoring of primary and confirmatory precursor-to-product ion transitions for the determination of E2 in serum.  相似文献   

17.
Circadian disruption can have several possible health consequences, but is not well studied. In order to measure circadian disruption, in relation to shift or night work, we developed a simple and sensitive method for the simultaneous determination of melatonin, cortisol and testosterone in human saliva. We used liquid-liquid extraction (LLE) followed by liquid chromatography coupled to electrospray tandem mass spectrometry (LC-ESI-MS/MS) recorded in positive ion mode. Saliva samples were collected by spitting directly into tubes and 250 μL were used for analysis. The limits of detection were 4.1 pmol/L, 0.27 nmol/L and 10.8 pmol/L for melatonin, cortisol, and testosterone, respectively. The developed method was sensitive enough to measure circadian rhythms of all 3 hormones in a pilot study among four healthy volunteers. It can therefor be used to study the impact of night work and working in artificial light on the workers circadian rhythms. To our knowledge this is the first LC-ESI-MS/MS method for simultaneous determination of salivary melatonin, cortisol and testosterone.  相似文献   

18.
AIM: In forensic toxicology it is important to have specific and sensitive analysis for quantification of illicit drugs in biological matrices. This paper describes a quantitative method for determination of cocaine and its major metabolites (ecgonine methyl ester, benzoylecgonine, norcocaine and ethylene cocaine) in whole blood and urine by liquid chromatography coupled with tandem mass spectrometry LC/MS/MS. METHOD: The sample pre-treatment (0.20 g) consisted of acid precipitation, followed by centrifugation and solid phase extraction of supernatant using mixed mode sorbent columns (SPEC MP1 Ansys Diag. Inc.). Chromatographic separation was performed at 30 degrees C on a reverse phase Zorbax C18 column with a gradient system consisting of formic acid, water and acetonitrile. The analysis was performed by positive electrospray ionisation with a triple quadropole mass spectrometer operating in multiple reaction monitoring (MRM) mode. Two MRM transitions of each analyte were established and identification criteria were set up based on the retention time and the ion ratio. The quantification was performed using deuterated internal analytes of cocaine, benzoylecgonine and ecgonine methyl ester. The calibration curves of extracted standards were linear over a working range of 0.001-2.00 mg/kg whole blood for all analytes. The limit of quantification was 0.008 mg/kg; the interday precision (measured by relative standard deviation-%RSD) was less than 10% and the accuracy (BIAS) less than 12% for all analytes in whole blood. Urine samples were estimated semi-quantitatively at a cut-off level of 0.15 mg/kg with an interday precision of 15%. CONCLUSION: A liquid chromatography mass spectrometric (LC/MS/MS) method has been developed for confirmation and quantification of cocaine and its metabolites (ecgonine methyl ester, benzoylecgonine, norcocaine and ethylene cocaine) in whole blood and semi-quantitative in urine. The method is specific and sensitive and offers thereby an excellent alternative to other methods such as GC-MS that involves derivatisation.  相似文献   

19.
A rapid, simple and highly sensitive method was developed for the quantitative determination of lansoprazole and rabeprazole concentrations in 20 microL of human serum using high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS). Analytes, along with an internal standard (lansoprazole deuterium derivatives), were separated using a mobile phase of acetonitrile/1mM ammonium formate (140/60, v/v) on a C18 analytical column and analyzed in the selected reaction-monitoring (SRM) mode. The lower limit of quantification was 0.25 ng/mL. A good linear response was observed for each analyte (from 0.25 ng to 2.5 microg/mL). This method was useful for therapeutic drug monitoring and pharmacokinetic studies.  相似文献   

20.
We have developed an analytical method used to quantify sphingolipids, including deoxysphingoid bases, in lipid extracts prepared from human plasma. In total, 39 analytes were identified and analyzed in a single chromatographic run in less than 5 min. The new method is 4-8 times faster and more sensitive than previously published methods. We also describe a simple sample preparation method that allows medium-throughput screening of human plasma samples. Mass spectrometric analyses were performed online using liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) in the positive multiple reaction monitoring mode. Samples were extracted using a one-phase extraction method (methanol-dichloromethane) with appropriate internal standards. Sphingolipid analytes were linear over a wide range of concentrations, from 0.01 to 50 ng/ml, with a high correlation coefficient (r2 = 0.999). We successfully applied this method to analyze the levels of sphingolipid metabolites in healthy human plasma. The ceramide, dihydroceramide, hexosylceramide, and GM3 levels observed in females were slightly higher than those observed in males.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号