首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We report a novel and simple method for mutation detection in DNA oligonucleotides using a double-stranded DNA specific dye (SYBR Green I) in nanostructured molecular assemblies, called reverse micelles. The intercalation of SYBR Green I into the duplex DNA exhibits fluorescent emission in a CTAB/isooctane reverse micellar system as well as in an aqueous solution. We found marked differences in the fluorescence intensity between perfectly matched and mismatched 52-mer synthetic oligonucleotides, which were designed to contain the YMDD motif of the hepatitis B virus (HBV) polymerase gene, in a reverse micellar solution. Using this method, we successfully detected a mutation in PCR-amplified oligonucleotides of the HBV polymerase gene in sera of four patients with chronic hepatitis B. This detection method does not require DNA immobilization, chemical modification of DNA, or any special apparatus; it only needs a normal fluorescence spectrophotometer, an inexpensive dye, and just 10 pmol of sample DNA.  相似文献   

2.
Xue Q  Jiang D  Wang L  Jiang W 《Bioconjugate chemistry》2010,21(11):1987-1993
An ultrasensitive fluorescence immunoassay method for quantitative detection of single molecules is developed on the basis of counting single magnetic nanobeads (MNBs) with combined amplification of DNA and dye/DNA conjugate. Highly amplified fluorescence signal and low background signal are achieved by using mutilabel bioconjugates made by linking multiple dye/DNA conjugates to streptavidin-coated magnetic nanobeads (SA-MNBs) and magnetic separation. In this method, human IgG (Ag) is captured on the silanized glass substrate surface, followed by immunoreaction with biotinylated mouse antihuman antibody (BT-Ab). Then, SA-MNBs are attached to the BT-Ab through the biotin/streptavidin interaction at a ratio of 1:1. Subsequently, a 30 base pair double-stranded oligonucleotide terminated with biotin (BT-dsDNA) is conjugated to the SA-MNBs. The resultant Ag-BT-Ab-SA-MNBs/BT-dsDNA/SYBR Green I is achieved after a fluorescent DNA probe, SYBR Green I, is added to the substrate and bound to the oligonucleotide at high ratios. Finally, epifluorescence microscopy coupled with a high-sensitivity electron multiplying charge-coupled device is employed for human IgG fluorescence imaging and detection. The number of fluorescent spots corresponding to single protein molecules on the images is counted. It is found that the number of fluorescent spots resulting from the SA-MNBs/BT-dsDNA/SYBR Green I immuotargeted on the glass slides is correlated with the concentration of human IgG target antigen in the range 3.0-50 fM.  相似文献   

3.
基于SYBR Green I的双链DNA定量方法   总被引:2,自引:0,他引:2  
摘要 基于SYBR Green I荧光染料与双链DNA(dsDNA)结合产生荧光的原理,建立一种高精度、高通量的双链DNA 定量方法。将梯度稀释后的基因组DNA及已知浓度的?DNA与等体积的SYBR Green I(4×)充分混合后,利用荧光定量PCR仪采集荧光信号,以ROX(1×)作为校正染料进行定量分析;同时利用紫外分光光度计对样品进行平行测定,比较该方法与紫外分光光度法的检测限与准确度。紫外分光光度法的检测限为2 ng/?l,而SYBR Green I荧光定量法的检测限可达到0.015 ng/?l,并且在0.015~2 ng/?l范围内,SYBR Green I荧光强度与?DNA浓度呈线性关系(R2=0.9999),比紫外分光光度法灵敏100倍以上,并可准确定量低纯度的DNA样品。此方法具有重复性好、高通量的特点,仅需少量的生物样本即可满足定量要求,为分子生物学研究及临床检验等多个领域提供了一种可靠的dsDNA定量方法。  相似文献   

4.
A high-throughput, 96-well microplate fluorescence assay (MFA) was developed for DNA quantification using the double-stranded DNA-binding dye SYBR Green I. Samples mixed with SYBR Green I in the wells of a microtiter plate produced fluorescence in proportion with DNA concentration which was measured using a fluorescence plate reader. The performance characteristics of the assay were compared with spectrophotometric quantification based on ultraviolet absorption and the Hoefer DyNA Quant assay utilizing the fluorescent dye, Hoechst 33258. The MFA accurately quantified different types of DNA over a broad linear dynamic range of concentrations (0.25–2,500 pg/μl), and was not affected by a variety of contaminants in the assay mixture.  相似文献   

5.
The highest sensitivity nucleic acid gel stains developed to date are optimally excited using short-wavelength ultraviolet or visible light. This is a disadvantage for laboratories equipped only with 306- or 312-nm UV transilluminators. We have developed a new unsymmetrical cyanine dye that overcomes this problem. This new dye, SYBR Gold nucleic acid gel stain, has two fluorescence excitation maxima when bound to DNA, one centered at approximately 300 nm and one at approximately 495 nm. We found that when used with 300-nm transillumination and Polaroid black-and-white photography, SYBR Gold stain is more sensitive than ethidium bromide, SYBR Green I stain, and SYBR Green II stain for detecting double-stranded DNA, single-stranded DNA, and RNA. SYBR Gold stain's superior sensitivity is due to the high fluorescence quantum yield of the dye-nucleic acid complexes ( approximately 0.7), the dye's large fluorescence enhancement upon binding to nucleic acids ( approximately 1000-fold), and its capacity to more fully penetrate gels than do the SYBR Green gel stains. We found that SYBR Gold stain is as sensitive as silver staining for detecting DNA-with a single-step staining procedure. Finally, we found that staining nucleic acids with SYBR Gold stain does not interfere with subsequent molecular biology protocols.  相似文献   

6.
A comparative study was conducted of a novel real-time quantitative PCR test (LightCycler System) with FastStart DNA Master(PLUS) SYBR Green I dye to detect DNA of human herpes virus 6 (HHV-6). Results were compared with those of a real-time quantitative PCR with hybridization probe (HP) formats using the fluorescence resonance energy transfer method, and with those of a single qualitative PCR test. The detection limit of the test with SYBR Green I dye was 20 copies of the virus, similar to that of the other two tests. The reproducibility was satisfactory. The new test has the same advantages as real-time PCR with HP formats and offers a greater versatility at lower cost.  相似文献   

7.
mRNA quantification has become a research hotspot. Quantitative real-time RT-PCR is a popular method but is known to lack precision. To rapidly monitor the kinetics of mRNA levels for the control of microbial fermentation processes, we developed an SYBR Green I-based universal method to directly quantify mRNA from fermentation samples. After total RNA was extracted, the mRNA was hybridized and protected by a longer DNA oligonucleotide. The probe length determined the strength of signal amplification. S1 nuclease and RNase A were used to remove excess probe, single-stranded RNA, and mis-matched RNA/DNA hybrids. Finally, the perfect-matched RNA/DNA hybrid was quantified by SYBR Green I dye. The conditions of liquid hybridization and enzyme digestion were systemically optimized. The kinetic tendency of phzC mRNA levels during phenazine-1-carboxylic acid fermentation was consistent with the results from MB hybridization in our previous report. The detection of mRNA levels of ten genes in Pseudomonas sp. M18G proved that this method is universal and feasible for mRNA quantification, and has great potential for application in mRNA quantification in various organisms.  相似文献   

8.
Following the initial report of the use of SYBR Green I for real-time polymerase chain reaction (PCR) in 1997, little attention has been given to the development of alternative intercalating dyes for this application. This is surprising considering the reported limitations of SYBR Green I, which include limited dye stability, dye-dependent PCR inhibition, and selective detection of amplicons during DNA melting curve analysis of multiplex PCRs. We have tested an alternative to SYBR Green I and report the first detailed evaluation of the intercalating dye SYTO9. Our findings demonstrate that SYTO9 produces highly reproducible DNA melting curves over a broader range of dye concentrations than does SYBR Green I, is far less inhibitory to PCR than SYBR Green I, and does not appear to selectively detect particular amplicons. The low inhibition and high melting curve reproducibility of SYTO9 means that it can be readily incorporated into a conventional PCR at a broad range of concentrations, allowing closed tube analysis by DNA melting curve analysis. These features simplify the use of intercalating dyes in real-time PCR and the improved reproducibility of DNA melting curve analysis will make SYTO9 useful in a diagnostic context.  相似文献   

9.
10.
In this work, a biosensor based on luminescence resonance energy transfer (LRET) from NaYF4:Yb,Tm upconversion nanoparticles (UCNPs) to SYBR Green I has been developed. The aptamers are covalently linked to UCNPs and hybridized with their complementary strands. The subsequent addition of SYBR Green allows SYBR Green I to insert into the formed double-stranded DNA (dsDNA) duplex and brings the energy donor and acceptor into close proximity, leading to the fluorescence of UCNPs transferred to SYBR Green I. When excited at 980 nm, the UCNPs emit luminescence at 477 nm, and this energy is transferred to SYBR Green I, which emits luminescence at 530 nm. In the presence of oxytetracycline (OTC), the aptamers prefer to bind to its corresponding analyte and dehybridize with the complementary DNA. This dehybridization leads to the liberation of SYBR Green I, which distances SYBR Green I from the UCNPs and recovers the UCNPs' luminescence. Under optimal conditions, a linear calibration is obtained between the ratio of I530 to I477 nm (I530/I477) and the OTC concentration, which ranges from 0.1 to 10 ng/ml with a limit of detection (LOD) of 0.054 ng/ml.  相似文献   

11.
针对传统电泳检测方法存在操作复杂、费时等缺点,提出一种用于检测K-ras癌基因点突变的实时荧光等位基因特异性扩增(Allele specific amplification,ASA)方法。该法采用突变型引物对结肠癌基因组中的K-ras基因进行等位基因特异性扩增,只有突变型样品能被顺利扩增出双链DNA产物,该产物能与双链DNA染料SYBR GreenⅠ结合,产生荧光信号从而被检测到。通过对荧光域值和溶解曲线分析来区分不同的基因突变类型。该法可以检测到野生型DNA中含量为1/1 000的突变型DNA,整个检测时间小于1 h。我们用该法检测31例结肠癌样品中K-ras基因密码子12发生的点突变,其中有15例检出为阳性。此外,还采用等位基因特异性扩增结合电泳分析对样品进行了检测,并对两种方法进行了比较。结果显示:实时荧光等位基因特异性扩增方法具有操作简便、快速、检测成本低等优点,为临床诊断基因突变引起的疾病提供了一种可行的手段。  相似文献   

12.
SYBR Gold is a commonly used and particularly bright fluorescent DNA stain, however, its chemical structure is unknown and its binding mode to DNA remains controversial. Here, we solve the structure of SYBR Gold by NMR and mass spectrometry to be [2-(4-{[diethyl(methyl)ammonio]methyl}phenyl)-6-methoxy-1-methyl-4-{[(2Z)-3-methyl-1,3-benzoxazol-2-ylidene]methyl}quinolin-1-ium] and determine its extinction coefficient. We quantitate SYBR Gold binding to DNA using two complementary approaches. First, we use single-molecule magnetic tweezers (MT) to determine the effects of SYBR Gold binding on DNA length and twist. The MT assay reveals systematic lengthening and unwinding of DNA by 19.1° ± 0.7° per molecule upon binding, consistent with intercalation, similar to the related dye SYBR Green I. We complement the MT data with spectroscopic characterization of SYBR Gold. The data are well described by a global binding model for dye concentrations ≤2.5 μM, with parameters that quantitatively agree with the MT results. The fluorescence increases linearly with the number of intercalated SYBR Gold molecules up to dye concentrations of ∼2.5 μM, where quenching and inner filter effects become relevant. In summary, we provide a mechanistic understanding of DNA-SYBR Gold interactions and present practical guidelines for optimal DNA detection and quantitative DNA sensing applications using SYBR Gold.  相似文献   

13.
A quantitative real-time polymerase chain reaction (PCR) procedure followed by melting curve analysis, using the green fluorescence dye SYBR Green I, was developed for rapid detection and differentiation of mycoplasma contaminants in cell cultures. This method showed that the detection of the target sequence was linear over a range from 10(4) to 10 colony-forming units (CFU) of the mycoplasma cells. Analysis of the melting temperature of the PCR products allowed differentiation of the major mycoplasma contaminants. These results demonstrate that the protocol described in the present study can decrease the time to obtain reproducible results by simultaneous detection and differentiation of the Mycoplasma species contaminating cell cultures.  相似文献   

14.
Various assays are available for quantification of DNA in solution, but none has been described that is both sensitive and specific for double-stranded (ds) DNA and features practical properties such as low dye and equipment costs, speed, and highly parallel microplate formats. Here we show that quantitative and sensitive measurement of ds DNA in solution is achieved using a 96-well microplate SYBR Green I assay and a standard uv transillumination-based gel-imaging system for detection. Specific detection of ds DNA was obtained over a broad concentration range of 0.5-500 ng using a single low dye concentration of up to 1/6250. Measured SYBR Green I fluorescence was not significantly affected by pH variation (4-10), assay volume (50-250 microliter l), and time (4-15 min), and measurements were appreciably compatile with commonly encountered concentrations of contaminating salts, organics, detergents, and other substances. ds DNA yielded up to 13-fold higher fluorescence compared to single-stranded DNA or RNA, but this ratio was dependent somewhat on GC content and fragment size. Of note, linear ds DNA fluoresced significantly stronger than supercoiled plasmid DNA. Our method should be broadly applicable for sensitive, rapid, and inexpensive ds DNA quantification in the average molecular biology laboratory.  相似文献   

15.
A FRET-based analysis of SNPs without fluorescent probes   总被引:2,自引:0,他引:2  
Fluorescence resonance energy transfer (FRET) is a simple procedure for detecting specific DNA sequences, and is therefore used in many fields. However, the cost is relatively high, because FRET-based methods usually require fluorescent probes. We have designed a cost-effective way of using FRET, and developed a novel approach for the genotyping of single nucleotide polymorphisms (SNPs) and allele frequency estimation. The key feature of this method is that it uses a DNA-binding fluorogenic molecule, SYBR Green I, as an energy donor for FRET. In this method, single base extension is performed with dideoxynucleotides labeled with an orange dye and a red dye in the presence of SYBR Green I. The dyes incorporated into the extended products accept energy from SYBR Green I and emit fluorescence. We have validated the method with ten SNPs, which were successfully discriminated by end-point measurements of orange and red fluorescence intensity in a microplate fluorescence reader. Using a mixture of homozygous samples, we also confirmed the potential of this method for estimation of allele frequency. Application of this strategy to large-scale studies will reduce the time and cost of genotyping a vast number of SNPs.  相似文献   

16.
为了建立对昆虫核型多角体病毒(nucleopolyhedrovirus)进行定量检测方法,本研究选用美国白蛾Hyphantria cunea核型多角体病毒的polyhedrin基因为目的基因,经引物设计、PCR 扩增、目的片段与载体连接转化以及重组质粒的鉴定,并对重组质粒标准品和样品DNA进行检测,构建出美国白蛾核型多角体病毒SYBR GreenⅠ荧光定量标准曲线。统计学分析显示标准品浓度的对数值与Ct 值之间存在良好的线性关系(R=0.998)。该方法的检测灵敏度为101~102拷贝/μL,线性范围达5个数量级,扩增产物形成单一的特异性熔解峰,组内组间的变异系数均小于3%。根据已建立的方法对不同感染时间段的感病幼虫进行检测,每毫克幼虫样本内病毒polyhedrin基因拷贝数增殖倍数对数值与感染时间(d)呈正相关(R=0.987)。这些结果表明,建立的美国白蛾核型多角体病毒荧光定量 PCR检测方法是可靠的,具有灵敏度高、重复性好等特点,可为昆虫核型多角体病毒体内增殖动态研究及昆虫病毒的标准化生产提供参考。  相似文献   

17.
针对转基因大豆中普遍含有的35S启动子进行引物设计,以双链DNA染料SYBR GreenⅠ为荧光标记物,利用实时荧光定量PCR方法对大豆样品进行检测。该法检测转基因大豆的检测低限为0.005 nmol/L的35S启动子,线性范围达3个数量级,可快速区分转基因大豆和非转基因大豆,具有快速、简便、灵敏、安全、高通量、低成本等优点,可推广用于转基因植物产品的快速定量检测。  相似文献   

18.
Tetraalkylammonium (TAA) derivatives have been reported to serve as stabilizers of asymmetrical cyanine dyes in aqueous solutions and to increase the yield and efficiency of polymerase chain reaction (PCR) detected by end-point analysis. In this study, we compared the ability of various TAA derivatives (with alkyl chain ranging from 1 to 5 carbons) and some other compounds to serve as enhancers of real-time PCR based on fluorescence detection from intercalating dye SYBR Green I (SGI). Our data indicate that TAA chlorides and some other TAA derivatives serve as potent enhancers of SGI-monitored real-time PCR. Optimal results were obtained with 10-16 mM tetrapropylammonium chloride. The effect of TAA compounds was dependent on the nature of counter ions present and composition of the reaction mixtures used. Based on measurements of SGI-generated fluorescence signal in the presence of PCR-amplified DNA fragments, oligonucleotide primers and/or various additives, we propose that TAA-derivatives reduce the binding of SGI to oligonucleotide primers and thus enhance primer-template interactions during annealing phase. Furthermore, these compounds serve as stabilizers of SGI-containing PCR mixtures. The combined data indicate that TAA derivatives might be a new class of additives contributing to robustness of real-time PCR monitored by asymmetrical cyanine dye SGI.  相似文献   

19.
用前染和后染两种不同的染色方法,研究比较SYBRGreenI和溴化乙锭(EB)两种核酸染料对凝胶中DNA的染色效果和灵敏度,及SYBRGreenI取代EB用于常规凝胶中核酸染色的可能性。结果表明,用前染法染色SYBRGreenI对琼脂糖凝胶中的核酸染色效果与EB相当;用后染法染色前者要优于后者,可显示5ng以下的DNA条带,在完全相同的操作条件下,其染色DNA条带背景清晰,灵敏度较高。因此,无致突变性新型染料SYBRGreenI可替代强致突变性染料EB用于检测凝胶中DNA片段大小、含量等,从而减少由于使用EB带来的环境污染和人体健康危害。  相似文献   

20.
A group testing (or pooling) method for DNA strands that identifies at least one strand in a pair of cross-hybridized oligonucleotides is given. This pooling method can be extended to any population of objects where certain pairs together produce an observable function or signal. Pairs of objects may work together to produce an undesirable result or a detrimental function. If just a single element of such a pair is identified and eliminated, then the undesirable function of that pair is destroyed. In particular, the ability to ensure that a set DNA probes do not yield undesired cross-hybridizations is important when these probes and/or their complements are used in the production of a hybridization signal that is intended to convey information. Here we report a "proof of principle" method, similar to those used to screen DNA libraries, that screens pools of probes for unwanted cross-hybridization events and identifies the offending probes. In the reported experiment, a cross-hybridized duplex in a pool of probes is detected by using the fluorescent dye SYBR Green I. This dye is known to produce greater fluorescence when bound to duplex DNA as opposed to single-stranded DNA. The method described here is sensitive, fast, and simple.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号