首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
Apigenin is a flavone and is being developed for treatment of cardiovascular disease. A sensitive and accurate quantitative detection method using liquid chromatography coupled with tandem mass spectrometry (LC/MS/MS) for the measurement of apigenin and luteolin levels in rat plasma is described. Analytes were separated on a separation by a Luna C(18) (5 microm, 100 mm x 2.0 mm) column with acetonitrile:methanol:water (35:40:60, v/v/v) as a mobile phase. The eluted compounds were detected by tandem mass spectrometry. Good linearity (R(2)>0.9997) was observed for both analytes over the range of 2.5-5000 ng/mL in 0.1mL of rat plasma. The overall accuracy of this method was 93-105% for apigenin and 95-112% for luteolin in rat plasma. Intra-assay and inter-assay variabilities were less than 11% in plasma. The lowest quantitation limit for both apigenin and luteolin was 2.5 ng/mL in 0.1 mL of rat plasma. Practical utility of this new LC/MS/MS method was demonstrated in a pilot pharmacokinetic study in rats following intravenous administration of apigenin. Metabolism of apigenin to luteolin in vivo was established.  相似文献   

2.
A liquid chromatography/tandem mass spectrometric (LC/MS/MS) assay was developed for the quantitative determination of salirasib (S-trans,trans-farnesylthiosalicylic acid, FTS) in human plasma. Sample pretreatment involved liquid-liquid extraction with methyl t-butyl ether of 0.5-mL aliquots of lithium heparin plasma spiked with the internal standard, S-trans,trans-5-fluoro-farnesylthiosalicylic acid (5-F-FTS). Separation was achieved on Waters X-Terra C(18) (50 mm x 2.1 mm i.d., 3.5 microm) at room temperature using isocratic elution with acetonitrile/10 mM ammonium acetate buffer mobile phase (80:20, v/v) containing 0.1% formic acid at a flow rate of 0.20 mL/min. Detection was performed using electrospray MS/MS by monitoring the ion transitions from m/z 357.2-->153.0 (salirasib) and m/z 375.1-->138.8 (5-F-FTS). Calibration curves were linear in the concentration range of 1-1000 ng/mL. A 5000 ng/mL sample that was diluted 1:10 (v/v) with plasma was accurately quantitated. The values for both within day and between day precision and accuracy were well within the generally accepted criteria for analytical method (<8.0%). This assay was subsequently used for the determination of salirasib concentrations in plasma of cancer patients after oral administration of salirasib at a dose of 400 mg.  相似文献   

3.
Nifedipine (NIF), a calcium channel antagonist, is metabolized primarily by cytochrome P450 (CYP3A4) to dehydronifedipine (DNIF). As such, NIF is often used as a probe drug for determining CYP3A4 activity in human studies. A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated to simultaneously determine NIF and DNIF in human plasma using nitrendipine as the internal standard (IS). After extraction of the plasma samples by ether-n-hexane (3:1, v/v), NIF, DNIF and the IS were subjected to LC/MS/MS analysis using electro-spray ionization (ESI). Chromatographic separation was performed on a Hypersil BDS C(18) column (50 mm x 2.1 mm, i.d., 3 microm). The method had a chromatographic running time of approximately 2.5 min and linear calibration curves over the concentrations of 0.5-100 ng/mL for NIF and DNIF. The recoveries of the one-step liquid extraction method were 81.3-89.1% for NIF and 71.6-80.4% for DNIF. The lower limit of quantification (LLOQ) of the analytical method was 0.5 ng/mL for both analytes. The intra- and inter-day precision was less than 15% for all quality control samples at concentrations of 2, 10, and 50 ng/mL. The validated LC/MS/MS method has been successfully used to study pharmacokinetic interactions of NIF with the herbal antidepressant St. John's wort in healthy volunteers. These results indicated that the developed LC/MS/MS method was efficient with a significantly shorter running time (2.5 min) for NIF and DNIF compared to those methods previously reported in the literature. The presented LC/MS/MS method had acceptable accuracy, precision and sensitivity and was used in a clinical pharmacokinetic interaction study of NIF with St. John's wort, a known herbal inducer of CYP3A4. St. John's wort was shown to induce NIF metabolism with increased plasma concentrations of DNIF.  相似文献   

4.
A sensitive and rapid method was developed and validated for the quantitative analysis of the novel anticancer agent SZ-685C in rat plasma using high-performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) in negative ion mode in order to support the following pre-clinical and clinical studies. SZ-685C and the internal standard (IS, emodin) were extracted from rat plasma by a simple liquid-liquid extraction technique using ethyl acetate as extraction solvent. Chromatographic separation was performed on an Elite Hypersil BDS C18 column (100 mm × 2.1 mm i.d., 3 μm). Elution was carried out using methanol/acetonitrile/2mM ammonium formate (pH 4) (80:15:5 (v/v/v)) at a flow-rate of 0.3 mL/min with a run time of 2.5 min. This assay was linear over a concentration range of 50-10,000 ng/mL with a lower limit of quantification of 50 ng/mL. The intra- and inter-batch precision was less than 15% for all quality control samples at concentrations of 100, 1000 and 7500 ng/mL. These results indicate that the method was efficient with a short run time and acceptable accuracy, precision and sensitivity. This method was successfully applied to explore pharmacokinetics of SZ-685C in rats after oral and intravenous administration of this agent. The absolute bioavailability is about 54.8-66.8% and the t(1/2) is 5.7-9.2h, these results provide basic information for further comprehensive pre-clinical research.  相似文献   

5.
Astragaloside IV is a novel cardioprotective agent extracted from the Chinese medical herb Astragalus membranaceus (Fisch) Bge. This agent is being developed for treatment for cardiovascular disease. Further development of Astragaloside IV will require detailed pharmacokinetic studies in preclinical animal models. Therefore, we established a sensitive and accurate high performance liquid chromatography (HPLC) coupled with tandem mass spectrometry (LC/MS/MS) quantitative detection method for measurement of Astragaloside IV levels in plasma, urine as well as other biological samples including bile fluid, feces and various tissues. Extraction of Astragaloside IV from plasma and other biological samples was performed by Waters OASIS(trade mark) solid phase extraction column by washing with water and eluting with methanol, respectively. An aliquot of extracted residues was injected into LC/MS/MS system with separation by a Cosmosil C18 5 microm, 150 mm x 2.0 mm) column. Acetonitrile:water containing 5 microM NaAc (40:60, v/v) was used as a mobile phase. The eluted compounds were detected by tandem mass spectrometry. The average extraction recoveries were greater than 89% for Astragaloside IV and digoxin from plasma, while extraction recovery of Astragaloside IV and digoxin from tissues, bile fluid, urine and fece ranged from 61 to 85%, respectively. Good linearity (R2>0.9999) was observed throughout the range of 10-5000 ng/ml in 0.5 ml rat plasma and 5-5000 ng/ml in 0.5 ml dog plasma. In addition, good linearity (R2>0.9999) was also observed in urine, bile fluid, feces samples and various tissue samples. The overall accuracy of this method was 93-110% for both rat plasma and dog plasma. Intra-assay and inter-assay variabilities were less than 15.03% in plasma. The lowest quantitation limit of Astragaloside IV was 10 ng/ml in 0.5 ml rat plasma and 5 ng/ml in 0.5 ml dog plasma, respectively. Practical utility of this new LC/MS/MS method was confirmed in pilot pharmacokinetic studies in both rats and dogs following intravenous administration.  相似文献   

6.
A rapid, sensitive and specific method was developed and validated using liquid chromatography-tandem mass spectrometry (LC/MS/MS) for determination of gefitinib in human plasma and mouse plasma and tissue. Sample preparation involved a single protein precipitation step by the addition of 0.1 mL of plasma or a 200 mg/mL tissue homogenate diluted 1/10 in human plasma with 0.3 mL acetonitrile. Separation of the compounds of interest, including the internal standard (d8)-gefitinib, was achieved on a Waters X-Terra C18 (50 mm x 2.1 mm i.d., 3.5 microm) analytical column using a mobile phase consisting of acetonitrile-water (70:30, v/v) containing 0.1% formic acid and isocratic flow at 0.15 mL/min for 3 min. The analytes were monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the range of 1-1000 ng/mL for the human plasma samples and 5-1000 ng/mL for mouse plasma and tissue samples with values for the coefficient of determination of > 0.99. The values for both within- and between-day precision and accuracy were well within the generally accepted criteria for analytical methods (< 15%). This method was subsequently used to measure concentrations of gefitinib in mice following administration of a single dose of 150 mg/kg intraperitoneally and in cancer patients receiving an oral daily dose of 250 mg.  相似文献   

7.
A rapid, sensitive and specific method was developed and validated using LC/MS/MS for determination of sorafenib in human plasma. Sample preparation involved a single protein precipitation step by the addition of 0.1 mL of plasma with 0.5 mL acetonitrile. Analysis of the compounds of interest including the internal standard ([(2)H(3)(15)N] sorafenib) was achieved on a Waters X-Terra C(18) (150 mm x 2.1mm i.d., 3.5 microm) analytical column using a mobile phase consisting of acetonitrile/10 mM ammonium acetate (65:35, v/v) containing 0.1% formic acid and isocratic flow at 0.2 mL/min for 6 min. The analytes were monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the range of 7.3-7260 ng/mL for the human plasma samples with values for the coefficient of determination of >0.96. The values for both within day and between day precision and accuracy were well within the generally accepted criteria for analytical methods (<15%).  相似文献   

8.
A rapid, sensitive and specific method was developed and validated using LC/MS/MS for determination of sunitinib in human plasma. Sample preparation involved a liquid-liquid extraction by the addition of 0.2mL of plasma with 4.0mL tert-butyl-methyl-ether extraction solution containing 25ng/mL of the internal standard clozapine. Separation of compounds was achieved on a C18 (50mmx2.1mm i.d., 3.5microm) analytical column using a mobile phase consisting of acetonitrile/H20 (65:35, v/v) containing 0.1% formic acid and isocratic flow at 0.150mL/min for 3min. The analytes were monitored by tandem-mass spectrometry with electrospray positive ionization. Linear calibration curves in human plasma were generated over the range of 0.2-500ng/mL with values for the coefficient of determination of >0.9950. Within- and between day precision and accuracy were < or =10%. The method was applied to the quantitation of sunitinib in plasma samples from a patient receiving daily oral therapy with sunitinib.  相似文献   

9.
A rapid, sensitive, and specific LC/MS/MS-based method was developed for determining the concentration of DMXAA in human and mouse plasma. Sample preparation involved a single protein precipitation step using acetonitrile. Separation of DMXAA and 6-isopropoxy-9-oxoxanthene-2-carboxylic acid, the internal standard, was achieved on a Waters X-Terra C(18) (50 mm x 2.1mm i.d., 3.5 microm) analytical column using a mobile phase consisting of acetonitrile/10 mM ammonium acetate (55:45, v/v) containing 0.1% formic acid and isocratic flow at 0.2 mL/min for 3 min. The analytes were monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the range of 5-3000 ng/mL. The values for precision and accuracy were <9.6%, except at the LLOQ (5 ng/mL) level, which was within 16.8%. Recovery of DMXAA in mouse plasma was >65%. DMXAA was stable through 2 freeze/thaw cycles, to 2h in mouse plasma or 50% acetonitrile, and on the autosampler to 5.1h. This method was subsequently used to measure concentrations of DMXAA in mice following intraperitoneal administration.  相似文献   

10.
A highly sensitive and ultra-fast high performance liquid chromatography- tandem mass spectrometry (LC–MS/MS) assay is developed and validated for the quantification of Lenalidomide in human plasma. Lenalidomide is extracted from human plasma by Liquid- Liquid Extraction by Ethyl Acetate and analyzed using a reversed phase isocratic elution on a XTerra RP18, (4.6 × 50 mM, 5 µm) column. A 0.1% Formic acid: Methanol (10:90% v/v), is used as mobile phase and detection was performed by Triple quadrupole mass spectrometry LC-MS/MS using electrospray ionization in positive mode. Fluconazole is used as the internal standard. The lower limit of quantification is 9.999 ng/mL for Lenalidomide. The calibration curves are consistently accurate and precise over the concentration range of 9.999 to 1010.011 ng/mL in plasma for Lenalidomide. This novel LC–MS/MS method competes with all the regulatory requirements and shows satisfactory accuracy and precision and is sufficiently sensitive for the performance of pharmacokinetic and bioequivalence studies in humans.  相似文献   

11.
In the present work, a high-throughput LC/MS/MS method using a Chromolith RP-18 (50 mm x 4.6 mm) monolithic column was developed and partially validated for the determination of bupropion (BUP), an anti-depressant drug, and its metabolites, hydroxybupropion and threo-hydrobupropion (TB), in human, mouse, and rat plasma. A modern integrated liquid chromatograph and an LC/MS/MS system with a TurboIonSpray (TIS) interface were used for the positive electrospray selected reaction monitoring (SRM) LC/MS analyses. Spiked control plasma calibration standards and quality control (QC) samples were extracted by semi-automated 96-well liquid-liquid extraction (LLE) using ethyl acetate. A mobile phase consisting of 8mM ammonium acetate-acetonitrile (55:45, v/v) delivered isocratically at 5 ml/min, and split post-column to 2 ml/min directed to the TIS, provided the optimum conditions for the chromatographic separation of bupropion and its metabolites within 23s. The isotope-labeled D(6)-bupropion and D(6)-hydroxybupropion were used as internal standards. The method was linear over a concentration range of 0.25-200 ng/ml (bupropion and threo-hydrobupropion), and 1.25-1000 ng/ml (hydroxybupropion). The intra- and inter-day assay accuracy and precision were within 15% for all analytes in each of the biological matrices. The monolithic column performance as a function of column backpressure, peak asymmetry, and retention time reproducibility was adequately maintained over 864 extracted plasma injections.  相似文献   

12.
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection (LC-MS/MS) was developed for the determination of a potent 5-HT(1B/1D) receptor agonist, rizatriptan in human plasma using granisetron as the internal standard. The analyte and internal standard were isolated from 100 microL plasma samples by liquid-liquid extraction (LLE) and chromatographed on a Lichrospher C18 column (4.6mm x 50mm, 5 microm) with a mobile phase consisting of acetonitrile-10mM aqueous ammonium acetate-acetic acid (50:50:0.5, v/v/v) pumped at 1.0 mL/min. The method had a chromatographic total run time of 2 min. A Varian 1200 L electrospray tandem mass spectrometer equipped with an electrospray ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 270-->201 (rizatriptan) and 313.4-->138 (granisetron) used for quantitation. The assay was validated over the concentration range of 0.05-50 ng/mL and was found to have acceptable accuracy, precision, linearity, and selectivity. The mean extraction recovery from spiked plasma samples was above 98%. The intra-day accuracy of the assay was within 12% of nominal and intra-day precision was better than 13% C.V. Following a 10mg dose of the compound administered to human subjects, mean concentrations of rizatriptan ranged from 0.2 to 70.6 ng/mL in plasma samples collected up to 24h after dosing. Inter-day accuracy and precision results for quality control samples run over a 5-day period alongside clinical samples showed mean accuracies of within 12% of nominal and precision better than 9.5% C.V.  相似文献   

13.
A 96-well single-pot protein precipitation, liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for the determination of muraglitazar, a PPAR alpha/gamma dual agonist, in human plasma. The internal standard, a chemical analogue, was dissolved in acetonitrile containing 0.1% formic acid. The solvent system was also served as a protein precipitation reagent. Human plasma samples (0.1 mL) and the internal standard solution (0.3 mL) were added to a 96-well plate. The plate was vortexed for 1 min and centrifuged for 5 min. Then the supernatant layers were directly injected into the LC/MS/MS system. The chromatographic separation was achieved isocratically on a Phenomenox C18(2) Luna column (2 mm x 50 mm, 5 microm). The mobile phase contained 20/80 (v/v) of water and acetonitrile containing 0.1% formic acid. Detection was by positive ion electrospray tandem mass spectrometry on a Sciex API 3000. The standard curve, which ranged from 1 to 1000 ng/mL, was fitted to a 1/x weighted quadratic regression model. This single-pot approach effectively eliminated three time consuming sample preparation steps: sample transfer, dry-down, and reconstitution before the injection, while it preserved all the benefits of the traditional protein precipitation. By properly adjusting the autosampler needle offset level, only the supernatant was injected, without disturbing the precipitated proteins in the bottom. As a result, the quality of chromatography and column life were not compromised. After more than 600 injections, there was only slightly increase of column back-pressure. The validation results demonstrated that this method was rugged and provide satisfactory precision and accuracy. The method has been successfully applied to analyze human plasma samples in support of a first-in-man study. This method has also been validated in monkey and mouse plasma for the determination of muraglitazar.  相似文献   

14.
The predominant circulating folate monoglutamate in human plasma (>90%), and thus the most significant folate for accurately diagnosing folate deficiency, is 5-methyltetrahydrofolic acid (5 MT). Folate deficiency is typically indicated when circulating folate levels are < or = 3 ng/mL. The quantitative determination of plasma folates in general, and of 5 MT in particular, is complicated by their naturally low levels (pg/mL to ng/mL), their instability, and their tendency to interconvert. Highly specific and sensitive analytical methods are needed to accurately quantify endogenous 5 MT in human plasma. A method that utilizes the specific high-affinity binding sites of bovine folate binding protein (FBP) and the selectivity and sensitivity of selected ion monitoring mode isotope-dilution liquid chromatography/mass spectrometry (LC/MS) to quantify plasma 5 MT has been developed. The method is based on the solid-phase affinity extraction (SPAE) of 5 MT and its stable isotopically labeled analogue ([13C(5)]5 MT) from plasma (1 mL) using FBP immobilized to polymeric beads. The excess high-affinity binding sites on the affinity columns enable quantitative extraction of 5 MT from plasma under optimized sample pH conditions. Additionally, it is demonstrated that plasma proteins do not hinder the determination of 5 MT; therefore, protein precipitation is not required before the affinity extraction step. Detection and quantification of the extracted 5 MT is provided by positive-ion mode LC/MS in which the protonated molecular ions [M+H](+) of the analyte and the internal standard are monitored. The method shows linearity over three orders of magnitude (0.04-40 ng/mL) and has limits of detection and quantification of 0.04 and 0.4 ng/mL, respectively. Calibration curves obtained by spiking 5 MT into plasma exhibited good linearity between 0 and 25 ng/mL and both the plasma calibration standards and the plasma samples were stable for at least 48 h at room temperature. The recovery (average +/- % RSD) of 5 MT spiked into plasma from 5 to 25 ng/mL was 98.0% +/- 1.6% (n = 15). 5 MT levels determined by SPAE-LC/MS compared to "total folate" levels determined by radioassay and microbiological assay were discordant. Reasons for the discordancy are theorized, but it is clear that there exists an urgent need for clinical reference materials containing certified folate levels.  相似文献   

15.
Tacrolimus (FK506) is a potent immunosuppressant widely used for organ transplantation patients while diltiazem (DTZ), a calcium-channel inhibitor, is often used in renal transplantation patients to prevent post-transplant hypertension. However, DTZ has a significant pharmacokinetic interaction with FK506. In this study, a rapid and sensitive ammonium-adduct based liquid chromatography-tandem mass spectrometry (LC/MS/MS) method has been developed and validated for the simultaneous determination of FK506 and DTZ in human whole blood using ascomycin as the internal standard (IS). After extraction of the whole blood samples by ethyl acetate, FK506, DTZ and the IS were subjected to LC/MS/MS analysis using electro-spray positive-ion mode ionization (ESI(+)). Chromatographic separation was performed on a Hypersil BDS C18 column (50 mm x 2.1 mm, i.d., 3 microm). The MS/MS detection was conducted by monitoring the fragmentation of 821.7-->768.9 (m/z) for FK506, 415.5-->310.3 (m/z) for DTZ and 809.8-->757.0 (m/z) for IS. The method had a chromatographic running time of approximately 2 min and linear calibration curves over the concentrations of 0.5-200 ng/mL for FK506 and 2-250 ng/mL for DTZ. The recoveries of liquid-liquid extraction method were 58.3-62.6% for FK506 and 50.4-58.8% for DTZ. The lower limit of quantification (LLOQ) of the analytical method was 0.5 ng/mL for FK506 and 2 ng/mL for DTZ. The intra- and inter-day precision was less than 15% for all quality control samples at concentrations of 2, 10, and 50 ng/mL for FK506 and 5, 25, and 100 ng/mL for DTZ. The validated LC/MS/MS method has been successfully used to analyze the concentrations of FK506 and DTZ in whole blood samples from pharmacokinetic studies in renal transplanted patients.  相似文献   

16.
Cyclophosphamide is a cytotoxic prodrug with a very narrow therapeutic index. To study the clinical pharmacology of cyclophosphamide in a large cohort of patients a previously published method for the simultaneous quantitative determination of cyclophosphamide and 4-hydroxycyclophosphamide in human plasma using liquid chromatography tandem mass spectrometry (LC-MS/MS) was optimized. Addition of an isotopically labelled internal standard and adaptation of the gradient resulted in a fast, robust and sensitive assay. Because 4-hydroxycyclophosphamide is not stable in plasma, the compound is derivatized with semicarbazide immediately after sample collection. Sample preparation was carried out by protein precipitation with methanol-acetonitrile (1:1, v/v), containing isotopically labelled cyclophosphamide and hexamethylphosphoramide as internal standards. The LC separation was performed on a Zorbax Extend C18 column (150 mm x 2.1 mm ID, particle size 5 microm) with 1 mM ammonium hydroxide in water-acetonitrile (90:10, v/v) as the starting gradient, at a flow-rate of 0.40 mL/min with a total run time of 6 min. The lower limit of quantification (LLQ, using a 100 microL sample volume) was 200 ng/mL and the linear dynamic range extended to 40,000 ng/mL for cyclophosphamide and 50-5000 ng/mL for 4-hydroxycyclophosphamide. Accuracies as well as precisions were lower than 20% at the LLQ concentration and lower than 15% for all other concentrations. This method has been successfully applied in our institute to support ongoing studies into the pharmacokinetics and pharmacogenetics of cyclophosphamide.  相似文献   

17.
A sensitive, specific and fast high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) assay for the determination of vinorelbine in mouse and human plasma is presented. A 200 microL aliquot was extracted with solid-phase extraction (SPE) using Bond-Elut C(2) cartridges. Dried extracts were reconstituted in 100 microL 1 mM ammonium acetate pH 10.5-acetonitrile-methanol (21:9:70, v/v/v) containing the internal standard vintriptol (100 ng/mL) and 10 microL volumes were injected onto the HPLC system. Separation was achieved on a 50 mm x 2.0 mm i.d. Gemini C(18) column using isocratic elution with 1 mM ammonium acetate pH 10.5-acetonitrile-methanol (21:9:70, v/v/v) at a flow rate of 0.4 mL/min. HPLC run time was only 5 min. Detection was performed using positive ion electrospray ionization followed by tandem mass spectrometry (ESI-MS/MS). The assay quantifies vinorelbine from 0.1 to 100 ng/mL using human plasma sample volumes of 200 microL. With this method vinorelbine can be measured in mouse plasma samples when these samples are diluted eight times in control human plasma. Calibration samples prepared in control human plasma can be used for the quantification of the drug. The lower limit of quantification in mouse plasma is 0.8 ng/mL. This assay is used to support preclinical and clinical pharmacologic studies with vinorelbine.  相似文献   

18.
A reverse-phase liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS) method was developed and validated for determination of aminoflavone (AF) in human plasma. Sample preparation involved a liquid–liquid extraction by the addition of 0.25 mL of plasma with 1.0 mL ethyl acetate containing 50 ng/mL of the internal standard zileuton. The analytes were separated on a Waters X-Terra? MS C18 column using a mobile phase consisting of methanol/water containing 0.45% formic acid (70:30, v/v) and isocratic flow at 0.2 mL/min for 6 min. The analytes were monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the AF concentration range of 5–2000 ng/mL in human plasma. The lower limit of quantitation (LLOQ) was 5 ng/mL for AF in human plasma. The accuracy and within- and between-day precisions were within the generally accepted criteria for bioanalytical method (<15%). This method was successfully applied to characterize AF plasma concentration-time profile in the cancer patients in a phase I trial.  相似文献   

19.
A liquid chromatography-mass spectrometry (LC/MS) assay method was developed for the quantification of PSC 833 in rat plasma, using amiodarone as internal standard (IS). Separation was achieved using a C(8) 3.5 microm (2.1 mm x 50 mm) column heated to 60 degrees C with a mobile phase consisting of acetonitrile-ammonium hydroxide 0.2% (90:10 v/v) pumped at a rate of 0.2 mL/min. Detection was accomplished by mass spectrometer using selected ion monitoring (SIM) in positive mode. An excellent linear relationship was present between peak height ratios and rat plasma concentrations of PSC 833 ranging from 10 to 5000 ng/mL (R(2)>0.99). Intra-day and inter-day coefficients of variation (CV%) were less than 15%, and mean error was less than 10% for the concentrations above the limit of quantification. The validated limit of quantification of the assay was 10 ng/mL based on 0.1 mL rat plasma. The method limit of detection, based on an average signal-to-noise (S/N) ratio of 3, was found to be 2.5 ng/mL. The assay was capable of measuring the plasma concentrations of PSC 833 in rats injected with a single dose of 5 mg/kg of the drug. PSC 833 and IS eluted within 4 min, free of interfering peaks. The method was found to be fast, sensitive, and specific for the quantification of PSC 833 in rat plasma.  相似文献   

20.
Tubeimoside I is an important component isolated from Bolbostemma paniculatum. Tubeimoside I has been demonstrated to possess many pharmacological activities, including anti-inflammatory, antitumor, and antitumor-promoting effects. The purpose of the present study was to examine in vivo pharmacokinetics and bioavailability of tubeimoside I in rats by using a liquid chromatography coupled with mass spectrometry quantitative detection method (LC/MS). The plasma samples were deproteinated, evaporated and reconstituted in 100 microl methanol prior to analysis. The separation was performed by Waters Symmetry C18 reversed-phase column (3.5 microm, 150 mm x 2.1mm, Waters Inc., USA) and a SB-C18 guard column (5 microm, 20 mm x 4.0mm). The mobile phase was a mixture of acetonitrile and water containing 5 microM NaAc (60:40, v/v). The method was validated within the concentration range 20-5000 ng/ml, and the calibration curves were linear with correlation coefficients >0.999. The lowest limit of quantitation (LLOQ) for tubeimoside I was 20 ng/ml in 0.1 ml rat plasma. The intra-assay accuracy and precision ranged from 92.4 to 104.9% and from 5.8 to 10.5%, respectively, while inter-assay accuracy and precision ranged from 94.2 to 95.0% and from 5.1 to 8.8%, respectively. The method was further applied to assess pharmacokinetics and oral bioavailability of tubeimoside I after intravenous and oral administration to rats. The oral bioavailability of tubeimoside I is only 0.23%, which indicates that tubeimoside I has poor absorption or undergoes acid-induced degradation. Practical utility of this new LC/MS method was confirmed in pilot pharmacokinetic studies in rats following both intravenous and oral administration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号