首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
Carbamazepine (CBZ) and oxcarbazepine (OXCBZ) are both antiepileptic drugs, which are prescribed as first-line drugs for the treatment of partial and generalized tonic-clonic epileptic seizures. In this paper, a specific and sensitive liquid chromatography-electrospray ionization mass spectrometry method was described for the simultaneous determination of carbamazepine (CBZ), oxcarbazepine (OXCBZ) and eight of their metabolites [CBZ-10,11-epoxide (CBZ-EP), 10,11-dihydro-10,11-trans-dihydroxy-carbamazepine (DiOH-CBZ), 10-hydroxy-10,11-dihydroCBZ (10-OH-CBZ), 2-hydroxycarbamazepine (2-OH-CBZ), 3-hydroxycarbamazepine (3-OH-CBZ), iminostilbene (IM), acridone (AO) and acridine (AI)] in human plasma. The work-up procedure involved a simple precipitation with acetone. Separation of the analytes was achieved within 50 min using a Zorbax eclipse XD8 C8 analytical column. The mobile phase consisted of a mixture of acetonitrile-formate buffer (2 mM, pH 3). Detection was performed using a quadrupole mass spectrometer fitted with an electrospray ion source. Mass spectrometric data were acquired in single ion recording mode at m/z 237 for CBZ, m/z 180 for CBZ-EP and AI, m/z 236 for OXCBZ, m/z 237 for 10-OH-CBZ, m/z 253 for 2-OH-CBZ, 3-OH-CBZ and DiOH-CBZ, m/z 196 for AO and m/z 194 for IM. For all analytes, the drug/internal standard peak height ratios were linked via a quadratic relationship to plasma concentrations. The extraction recovery averaged 90% for CBZ, 80% for OXCBZ and was 80-105% for the metabolites. The lower limit of quantitation was 0.5mg/l for CBZ, 0.4 mg/l for OXCBZ and ranged from 0.02 to 0.3 mg/l for the metabolites. Precision ranged from 2 to 13% and accuracy was between 86 and 112%. This method was found suitable for the analysis of plasma samples collected during therapeutic drug monitoring of patients treated with CBZ or OXCBZ.  相似文献   

2.
A high-performance liquid chromatographic method with UV detection for the simultaneous analysis of the antiepileptic drug carbamazepine and five of its metabolites in human plasma has been developed. The analysis was carried out on a reversed-phase column (C8, 150×4.6 mm I.D., 5 μm) using acetonitrile, methanol and a pH 1.9 phosphate buffer as the mobile phase. Under these chromatographic conditions, carbamazepine and its metabolites 10,11-dihydro-10,11-epoxycarbamazepine, 10,11-dihydro-10,11-dihydroxycarbamazepine, 2-hydroxycarbamazepine, 3-hydroxycarbamazepine and 10,11-dihydro-10-hydroxycarbamazepine are baseline separated in less than 18 min. The extraction of the analytes from plasma samples was performed by means of an original solid-phase extraction procedure using Oasis HLB cartridges. The method requires only 250 μl of plasma for one complete analysis. The repeatability (RSD%<2.4), intermediate precision (RSD%<3.5) and extraction yield (84.8–103.0%) were very good for all analytes. The method is suitable for reliable therapeutic drug monitoring of patients undergoing chronic treatment with carbamazepine and for kinetic–metabolic studies of this drug.  相似文献   

3.
High-performance liquid chromatography (HPLC) was used for simultaneous quantitation of carbamazepine (CBZ) and carbamazepine 10,11-epoxide (CBZ-EP) in plasma and saliva. Because concentrations of CBZ can greatly exceed those of CBZ-EP after single doses, two internal standards, lorazepam and N-desmethyldiazepam were added to all samples. Following extraction with chloroform, the components are separated on a μBondapak CN column with a mobile phase composed of 30% acetonitrile in water. Total chromatography time is 10 min. Concentrations of CBZ and CBZ-EP as low as 18 and 56 ng/ml, respectively, can be detected using 0.5 ml of plasma or saliva. The maximum within-day and day-to-day coefficients of variation for both compounds are 6.3 and 7.0%, respectively. Specificity of the method was supported by a significant correlation (r = 0.99) between assay results of the present method and those of a previously published HPLC assay. Application of the method to protein binding and salivary measurements in a single-dose CBZ disposition study is demonstrated.  相似文献   

4.
A rapid, sensitive and accurate liquid chromatographic-tandem mass spectrometric method is described for the determination of tamsulosin in dog plasma. Tamsulosin was extracted from plasma using a mixture of hexane-ethyl acetate (2:1, v/v) and separated on a C18 column interfaced with a triple quadrupole tandem mass spectrometer. The mobile phase consisting of a mixture of methanol, water and formic acid (80:20:1, v/v/v) was delivered at a flow rate of 0.5 ml/min. Atmospheric pressure chemical ionization (APCI) source was operated in positive ion mode. Selected reaction monitoring (SRM) mode using the transitions of m/z 409-->m/z 228 and m/z 256-->m/z 166.9 were used to quantify tamsulosin and the internal standard, respectively. The linearity was obtained over the concentration range of 0.1-50.0 ng/ml for tamsulosin and the lower limit of quantitation was 0.1 ng/ml. For each level of QC samples, inter- and intra-run precision was less than 5.0 and 4.0% (relative standard deviation (R.S.D.)), respectively, and accuracy was within +/-0.3% (relative error (R.E.)). This method was successfully applied to pharmacokinetic study of a tamsulosin formulation product after oral administration to beagle dogs.  相似文献   

5.
A rapid, selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) method with positive electrospray ionization (ESI) was developed for the quantification of ranolazine in human plasma. After liquid-liquid extraction of ranolazine and internal standard (ISTD) phenoprolamine from a 100 microl specimen of plasma, HPLC separation was achieved on a Nova-Pak C(18) column, using acetonitrile-water-formic acid-10% n-butylamine (70:30:0.5:0.08, v/v/v/v) as the mobile phase. The mass spectrometer was operated in multiple reaction monitoring (MRM) mode using the transition m/z 428.5-->m/z 279.1 for ranolazine and m/z 344.3-->m/z 165.1 for the internal standard, respectively. Linear calibration curves were obtained in the concentration range of 5-4000 ng/ml, with a lower limit of quantitation (LLOQ) of 5 ng/ml. The intra- and inter-day precision values were below 3.7% and accuracy was within +/-3.2% at all three quality control (QC) levels. This method was found suitable for the analysis of plasma samples collected during the phase I pharmacokinetic studies of ranolazine performed in 28 healthy volunteers after single oral doses from 200 mg to 800 mg.  相似文献   

6.
A rapid, selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method with electrospray ionization (ESI) was developed and validated for the simultaneous determination of pitavastatin and its lactone in human plasma and urine. Following a liquid-liquid extraction, both the analytes and internal standard racemic i-prolact were separated on a BDS Hypersil C(8) column, using methanol-0.2% acetic acid in water (70: 30, v/v) as the mobile phase. The mass spectrometer was operated in multiple reaction monitoring (MRM) mode using the transition m/z 422.4-->m/z 290.3 for pitavastatin, m/z 404.3-->m/z 290.3 for pitavastatin lactone and m/z 406.3-->m/z 318.3 for the internal standard, respectively. Linear calibration curves of pitavastatin and its lactone were obtained in the concentration range of 1-200 ng/ml, with a lower limit of quantitation of 1 ng/ml. The intra- and inter-day precision values were less than 4.2%, and accuracies were between -8.1 and 3.5% for both analytes. The proposed method was utilized to support clinical pharmacokinetic studies of pitavastatin in healthy subjects following oral administration.  相似文献   

7.
To study the use of hair analysis in monitoring drug compliance and historical changes in pharmacokinetics we developed a method for the quantitative determination of the anti-epileptic drug carbamazepine (CBZ) and trans-10,11-dihydro-10,11-dihydroxy-carbamazepine (CBZ-diol) in hair from carbamazepine users. Digestion by 1 M NaOH was found to be the best method for isolating CBZ and CBZ-diol from hair, followed by solid-phase extraction and reversed-phase HPLC with UV detection. Recoveries from spiked hair samples were 76–86%. Within-day precision (C.V.; n=10) for CBZ and CBZ-diol in hair of a CBZ user containing 10.9 μg/g CBZ and 3.2 μg/g CBZ-diol were 1.7 and 5.0%, respectively. Sectional hair analysis of a patient on a constant dosage of CBZ demonstrates an exponential decrease in hair concentrations of CBZ and CBZ-diol with increasing distance from the root, probably caused by shampooing. No CBZ-10,11-epoxide (CBZ-epox) could be detected. However, one component in the chromatogram is probably CBZ-β-hydroxythioether, an adduct of CBZ-epox with cysteine, or acridinethioacetal, its rearrangement product. The concentration of this component does not decrease with increasing distance from the root.  相似文献   

8.
A rapid, sensitive and accurate liquid chromatographic-tandem mass spectrometry (LC-MS-MS) method is described for the determination of duloxetine in human plasma. Duloxetine was extracted from plasma using methanol and separated on a C18 column. The mobile phase consisting of a mixture of acetonitrile and 5mM ammonium acetate (45:55, v/v, pH 3.5) was delivered at a flow rate of 0.3 ml/min. Atmospheric pressure ionization (API) source was operated in positive ion mode. Multiple reaction monitoring (MRM) mode using the transitions of m/z 298.1-->m/z 44.0 and m/z 376.2-->m/z 123.2 were used to quantify duloxetine and internal standard (I.S.), respectively. The linearity was obtained over the concentration range of 0.1-50.0 ng/ml and the lower limit of quantitation (LLOQ) was 0.1 ng/ml. This method was successfully applied to pharmacokinetic study of a duloxetine formulation product after oral administration to healthy human subjects.  相似文献   

9.
A rapid and feasible method was developed for the analysis of carbamazepine and its five metabolites (10,11-dihydro-10,11-epoxycarbamazepine, 10,11-dihydro-10,11-dihydroxycarbamazepine, 10,11-dihydro-10-hydroxycarbamazepine, 2-hydroxycarbamazepine and 3-hydroxycarbamazepine) in human plasma. Separation of the analytes is based on micellar electrokinetic chromatography, in untreated fused-silica capillary (48.5/40.0 cm length, 50 microm I.D.) with phosphate buffer (30 mM, pH 8.00) as background electrolyte, containing 50 mM sodium dodecylsulfate, and methanol (15%, v/v) as organic modifier. Clean up of human plasma samples was carried out by means of a solid-phase extraction procedure, which gave a high extraction yield for all six carbamazepines (>88%). The overall precision of the method gives a mean RSD of about 1.8%. The limit of quantitation for all analytes is < or = 0.30 microg ml(-1), the limit of detection < or = 0.12 microg ml(-1).  相似文献   

10.
A rapid, sensitive and accurate liquid chromatographic-tandem mass spectrometry method is described for the simultaneous determination of nebivolol and valsartan in human plasma. Nebivolol and valsartan were extracted from plasma using acetonitrile and separated on a C18 column. The mobile phase consisting of a mixture of acetonitrile and 0.05 mM formic acid (50:50 v/v, pH 3.5) was delivered at a flow rate of 0.25 ml/min. Atmospheric pressure ionization (API) source was operated in both positive and negative ion mode for nebivolol and valsartan, respectively. Selected reaction monitoring mode (SRM) using the transitions of m/z 406.1-->m/z 150.9; m/z 434.2-->m/z 179.0 and m/z 409.4-->m/z 228.1 were used to quantify nebivolol, valsartan and internal standard (IS), respectively. The linearity was obtained over the concentration range of 0.01-50.0 ng/ml and 1.0-2000.0 ng/ml and the lower limits of quantitation were 0.01 ng/ml and 1.0 ng/ml for nebivolol and valsartan, respectively. This method was successfully applied to the pharmacokinetic study of fixed dose combination (FDC) of nebivolol and valsartan formulation product after an oral administration to healthy human subjects.  相似文献   

11.
A simple, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of metoprolol succinate (MPS) and amlodipine besylate (AM) using hydrochlorothiazide (HCTZ) as IS in human plasma. Both the drugs were extracted by simple liquid-liquid extraction with chloroform. The chromatographic separation was performed on a reversed-phase peerless basic C18 column with a mobile phase of methanol-water containing 0.5% formic acid (8:2, v/v). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The method was validated over the concentration range of 1-100ng/ml for MPS and 1-15ng/ml AM in human plasma. The MRM transition of m/z 268.10-103.10, m/z 409.10-334.20 and m/z 296.00-205.10 were used to measure MPS, AM and HCTZ (IS), respectively. This method was successfully applied to the pharmacokinetic study of fixed dose combination (FDC) of MPS and AM formulation product after an oral administration to Indian healthy human volunteers.  相似文献   

12.
A rapid, sensitive and reliable method was developed to quantitate omeprazole in human plasma using liquid chromatography-tandem mass spectrometry. The assay is based on protein precipitation with acetonitrile and reversed-phase liquid chromatography performed on an octadecylsilica column (55 mm x 2mm, 3 microm particles), the mobile phase consisted of methanol-10 mM ammonium acetate (60:40, v/v). Omeprazole and flunitrazepam, the internal standard, elute at 0.80+/-0.10 min with a total run time 1.35 min. Quantification was through positive ion mode and selected reaction monitoring mode at m/z 346.1-->197.9 for omeprazole and m/z 314.0-->268.0 for flunitrazepam, respectively. The lower limit of quantitation was 1.2 ng/ml using 0.25 ml of plasma and linearity was observed from 1.2 to 1200 ng/ml. Within-day and between-day precision expressed by relative standard deviation was less than 5% and inaccuracy did not exceed 12%. The assay was applied to the analysis of samples from a pharmacokinetic study.  相似文献   

13.
A sensitive and specific method for determination of viaminate in human plasma by using high-performance liquid chromatography coupled with electrospray tandem mass spectrometry (LC-MS/MS) was developed in this study. The plasma samples were simply deproteinated, extracted, evaporated, and then reconstituted in 200 microl of methanol prior to analysis. Chromatographic separation was carried out on a Shimadzu VP-ODS column (250 mm x 2.0 mm, 5 microm) with a mobile phase of methanol-water (95:5, v/v) at a flow rate of 0.2 ml/min. Quantification was performed in the negative-ion electrospray ionization mode by selected ion monitoring of the product ions at m/z 164 for viaminate and m/z 109 for testosterone propionate which was used as the internal standard. The corresponding parent ions were m/z 446 and m/z 345. A linear calibration curve was observed within the concentration range of 0.10-200 ng/ml. The lowest limit of quantitation (LLOQ) was 0.1 ng/ml. The extraction-efficiency at three concentrations was 100.7, 93.6, and 99.7%. Practical utility of this new LC-MS/MS method was confirmed in pilot pharmacokinetic studies in humans following oral administration.  相似文献   

14.
A sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the determination of hydroxysafflor yellow A (HSYA) in human plasma. HSYA was extracted from human plasma by using solid-phase extraction technique. Puerarin was used as the internal standard. A Shim-pack VP-ODS C(18) (150mm x 4.6mm, 5 microm) column and isocratic elution system composing of methanol and 5mM ammonium acetate (80:20, v/v) provided chromatographic separation of analytes followed by detection with mass spectrometry. The mass transition ion-pair was followed as m/z 611.19-->491.19 for HSYA and m/z 415.19-->295.10 for puerarin. The proposed method has been validated with a linear range of 1-1000 ng/ml for HSYA with a correlation coefficient >/=0.999. The lower limit of quantitation was 1 ng/ml. The intra-batch and inter-batch precision and accuracy were within 10%. The average extraction recovery was 81.7%. The total run time was 5.5 min. The validated method was successfully applied to the study on pharmacokinetics of HSYA in 12 healthy volunteers after a single oral administration of safflower oral solution containing 140 mg of HSYA.  相似文献   

15.
A liquid chromatography-mass spectrometry method is described for the determination of tetramethylpyrazine (TMP) and its active metabolite, 2-hydroxymethyl-3,5,6-trimethylpyrazine (HTMP) in dog plasma. This method involves a plasma clean-up step using protein precipitation procedure followed by LC separation and positive electrospray ionization mass spectrometry detection (ESI-MS). Chromatographic separation of the analytes was achieved on a C18 column using a mobile phase of methanol, water and acetic acid (50:50:0.6, v/v/v) at a flow rate of 1.0 ml/min. Selected ion monitoring (SIM) mode was used for analyte quantitation at m/z 137.2 for TMP, m/z 153.2 for HTMP and m/z 195.2 for caffeine. The linearity was obtained over the concentration ranges of 20-6000 ng/ml for TMP and 20-4000 ng/ml for HTMP and the lower limit of quantitation was 20 ng/ml for both analytes. For each level of QC samples, both inter- and intra-day precisions (R.S.D.) were 相似文献   

16.
A selective and sensitive high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (ESI-MS/MS) method for simultaneous determination of metformin and rosiglitazone in human plasma using phenformin as internal standard (IS) has been first developed and validated. Plasma samples were precipitated by acetonitrile and the analytes were separated on a prepacked Phenomenex Luna 5u CN 100A (150 mm x 2.0 mm I.D.) column using a mobile phase comprised of methanol:30 mM ammonium acetate pH 5.0 (80:20, v/v) delivered at 0.2 ml/min. Detection was performed on a Finnigan TSQ triple-quadrupole tandem mass spectrometer in positive ion selected reaction monitoring (SRM) mode using electrospray ionization. The ion transitions monitored were m/z 130.27-->71.11 for metformin, m/z 358.14-->135.07 for rosiglitazone and m/z 206.20-->105.19 for the IS. The standard curves were linear (r(2)>0.99) over the concentration range of 5-3000 ng/ml for metformin and 1.5-500 ng/ml for rosiglitazone with acceptable accuracy and precision, respectively. The within- and between-batch precisions were less than 15% of the relative standard deviation. The limit of detection (LOD) of both metformin and rosiglitazone was 1 ng/ml. The method described is precise and sensitive and has been successfully applied to the study of pharmacokinetics of compound metformin and rosiglitazone capsules in 12 healthy Chinese volunteers.  相似文献   

17.
A highly sensitive method for quantitation of tamsulosin in human plasma using 1-(2,6-dimethyl-3-hydroxylphenoxy)-2-(3,4-methoxyphenylethylamino)-propane hydrochloride as the internal standard (I.S.) was established using liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS). After alkalization with saturated sodium bicarbonate, plasma were extracted by ethyl acetate and separated by HPLC on a C18 reversed-phase column using a mobile phase of methanol-water-acetic acid-triethylamine (620:380:1.5:1.5, v/v). Analytes were quantitated using positive electrospray ionization in a quadrupole spectrometer. LC-ESI-MS was performed in the selected ion monitoring (SIM) mode using target ions at m/z 228 for tamsulosin and m/z 222 for the I.S. Calibration curves, which were linear over the range 0.2-30 ng/ml, were analyzed contemporaneously with each batch of samples, along with low (0.5 ng/ml), medium (3 ng/ml) and high (30 ng/ml) quality control samples. The intra- and inter-assay variability ranged from 2.14 to 8.87% for the low, medium and high quality control samples. The extraction recovery of tamsulosin from plasma was in the range of 84.2-94.5%. The method has been used successfully to study tamsulosin pharmacokinetics in adult humans.  相似文献   

18.
Glipizide and rosiglitazone are widely used to treat Type 2 diabetes. In order to investigate drug-drug protein binding interaction between glipizide and rosiglitazone, a method was developed and validated for simultaneously determining the free (unbound) fraction of glipizide and rosiglitazone in plasma employing equilibrium dialysis for the separation of free drug and liquid chromatography-tandem mass spectrometry (LC-MS/MS) for quantitation. Post-dialysis human plasma or buffer samples of 0.2 ml were extracted using a liquid-liquid extraction procedure and analyzed by a high performance liquid chromatography electrospray tandem mass spectrometer system. The compounds were eluted isocratically on a Zorbax SB-Phenyl column, ionized using an atmospheric pressure electrospray ionization source and analyzed in positive ion mode with multiple reaction monitoring. The ion transitions monitored were m/z 446-->321 for glipizide, m/z 358-->135 for rosiglitazone, and m/z 271-->155 for tolbutamide (internal standard, IS). The chromatographic run time was 5 min per injection, with retention times of 2.3, 3.4 and 2.3 min for glipizide, rosiglitazone and IS, respectively. The calibration curves of glipizide and rosiglitazone were over the range of 1-2000 ng/ml (r(2)>0.9969) in the combined matrix of human plasma and isotonic sodium phosphate buffer (1:1, v/v). The inter-assay precision and accuracy of the quality control samples were <10.9% of coefficient of variability and >93.5% and 94.5% of nominal concentration for glipizide and rosiglitazone, respectively. The lower limit of quantitation of both glipizide and rosiglitazone was 1.0 ng/ml. Both glipizide and rosiglitazone bound to plasma protein extensively (>99% bound). Glipizide and rosiglitazone free fraction averaged 0.678+/-0.071 and 0.389+/-0.061%, respectively, at plasma concentration of 1000 ng/ml. This developed method proves reproducible and sensitive and its application to clinical samples is also reported.  相似文献   

19.
A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of metoprolol tartrate (MT) and ramipril, in human plasma. Both the drugs were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v). The chromatographic separation was performed on a reversed-phase C8 column with a mobile phase of 10 mM ammonium formate-methanol (3:97, v/v). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The method was validated over the concentration range of 5-500 ng/ml for metoprolol and ramipril in human plasma. The precursor to product ion transitions of m/z 268.0-103.10 and m/z 417.20-117.20 were used to measure metoprolol and ramipril, respectively.  相似文献   

20.
A sensitive method was developed for the simultaneous determination of omeprazole and its major metabolites 5-hydroxyomeprazole and omeprazole sulfone in human plasma by HPLC-electrospray mass spectrometry. Following liquid-liquid extraction HPLC separation was achieved on a ProntoSil AQ, C18 column using a gradient with 10 mM ammonium acetate in water (pH 7.25) and acetonitrile. The mass spectrometer was operated in the selected ion monitoring mode using the respective MH(+) ions, m/z 346 for omeprazole, m/z 362 for 5-hydroxy-omeprazole and omeprazol-sulfone and m/z 300 for the internal standard (2-{[(3,5-dimethylpyridine-2-yl)methyl]thio}-1H-benzimidazole-5-yl)methanol. The limit of quantification (LOQ) achieved with this method was 5 ng/ml for 5-hydroxyomeprazole and 10 ng/ml for omeprazole and omeprazole-sulfone using 0.25 ml of plasma. Intra- and inter-assay variability was below 11% over the whole concentration range from 5 to 250 ng/ml for 5-hydroxyomeprazol and from 10 to 750 ng/ml for omeprazole and omeprazole-sulfone. The method was successfully applied to the determination of pharmacokinetic parameters of esomeprazole and the two major metabolites after a single dose and under steady state conditions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号