首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of metoprolol tartrate (MT) and ramipril, in human plasma. Both the drugs were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v). The chromatographic separation was performed on a reversed-phase C8 column with a mobile phase of 10 mM ammonium formate-methanol (3:97, v/v). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The method was validated over the concentration range of 5-500 ng/ml for metoprolol and ramipril in human plasma. The precursor to product ion transitions of m/z 268.0-103.10 and m/z 417.20-117.20 were used to measure metoprolol and ramipril, respectively.  相似文献   

2.
A simple method using a one-step liquid-liquid extraction (LLE) with methyl-t-butyl ether (MTBE) followed by high-performance liquid chromatography (HPLC) with negative-ion electrospray ionization tandem mass spectrometric (ESI-MS/MS) detection was developed for the determination of cilnidipine in human plasma using benidipine as an internal standard (IS). Acquisition was performed in multiple reaction monitoring (MRM) mode, by monitoring the transitions: m/z 491.1>121.8 for cilnidipine and m/z 504.2>122.1 for IS, respectively. Analytes were chromatographed on a CN column by isocratic elution using 10mM ammonium acetate buffer-methanol (30:70, v/v; adjusted with acetic acid to pH 5.0). Results were linear (r2=0.99998) over the studied range (0.1-20ng/ml) with a total LC-MS/MS analysis time per run of 3min. The developed method was validated and successfully applied to a cilnidipine bioequivalence study in 24 healthy male volunteers.  相似文献   

3.
A rapid, sensitive and accurate liquid chromatographic-tandem mass spectrometry method is described for the simultaneous determination of nebivolol and valsartan in human plasma. Nebivolol and valsartan were extracted from plasma using acetonitrile and separated on a C18 column. The mobile phase consisting of a mixture of acetonitrile and 0.05 mM formic acid (50:50 v/v, pH 3.5) was delivered at a flow rate of 0.25 ml/min. Atmospheric pressure ionization (API) source was operated in both positive and negative ion mode for nebivolol and valsartan, respectively. Selected reaction monitoring mode (SRM) using the transitions of m/z 406.1-->m/z 150.9; m/z 434.2-->m/z 179.0 and m/z 409.4-->m/z 228.1 were used to quantify nebivolol, valsartan and internal standard (IS), respectively. The linearity was obtained over the concentration range of 0.01-50.0 ng/ml and 1.0-2000.0 ng/ml and the lower limits of quantitation were 0.01 ng/ml and 1.0 ng/ml for nebivolol and valsartan, respectively. This method was successfully applied to the pharmacokinetic study of fixed dose combination (FDC) of nebivolol and valsartan formulation product after an oral administration to healthy human subjects.  相似文献   

4.
A selective and sensitive high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (ESI-MS/MS) method for simultaneous determination of metformin and rosiglitazone in human plasma using phenformin as internal standard (IS) has been first developed and validated. Plasma samples were precipitated by acetonitrile and the analytes were separated on a prepacked Phenomenex Luna 5u CN 100A (150 mm x 2.0 mm I.D.) column using a mobile phase comprised of methanol:30 mM ammonium acetate pH 5.0 (80:20, v/v) delivered at 0.2 ml/min. Detection was performed on a Finnigan TSQ triple-quadrupole tandem mass spectrometer in positive ion selected reaction monitoring (SRM) mode using electrospray ionization. The ion transitions monitored were m/z 130.27-->71.11 for metformin, m/z 358.14-->135.07 for rosiglitazone and m/z 206.20-->105.19 for the IS. The standard curves were linear (r(2)>0.99) over the concentration range of 5-3000 ng/ml for metformin and 1.5-500 ng/ml for rosiglitazone with acceptable accuracy and precision, respectively. The within- and between-batch precisions were less than 15% of the relative standard deviation. The limit of detection (LOD) of both metformin and rosiglitazone was 1 ng/ml. The method described is precise and sensitive and has been successfully applied to the study of pharmacokinetics of compound metformin and rosiglitazone capsules in 12 healthy Chinese volunteers.  相似文献   

5.
A simple, sensitive and rapid liquid chromatography/tandem mass spectrometric (LC-MS/MS) method was developed and validated for quantification of chloroquine, an antimalarial drug, in plasma using its structural analogue, piperazine bis chloroquinoline as internal standard (IS). The method is based on simple protein precipitation with methanol followed by a rapid isocratic elution with 10 mM ammonium acetate buffer/methanol (25/75, v/v, pH 4.6) on Chromolith SpeedROD RP-18e reversed phase chromatographic column and subsequent analysis by mass spectrometry in the multiple reaction monitoring mode (MRM). The precursor to product ion transitions of m/z 320.3-->247.2 and m/z 409.1-->205.2 were used to measure the analyte and the IS, respectively. The assay exhibited a linear dynamic range of 2.0-489.1 ng/mL for chloroquine in dog plasma. The limit of detection (LOD) and lower limit of quantification (LLOQ) were 0.4 and 2.0 ng/mL, respectively in 0.05 mL plasma. Acceptable precision and accuracy were obtained for concentrations over the standard curve range of 2.0-489.1 ng/mL. A run time of 2.0 min for a sample made it possible to achieve a throughput of more than 400 plasma samples analyzed per day. The validated method was successfully used to analyze samples of dog plasma during non-clinical study of chloroquine.  相似文献   

6.
A simple, sensitive and specific HPLC method with tandem mass spectrometry (HPLC/MS/MS) detection has been developed and validated for the simultaneous quantification of tiloronoxim and its major active metabolite, tilorone, in human urine. The analytes, together with metoprolol, which was employed as an internal standard (IS), were extracted with a mixture solvent of chloroform/ethyl ether (1/2, v/v). The chromatographic separation was performed on a narrow-bore reversed phase HPLC column with a gradient mobile phase of methanol/water containing 15 mM ammonium bicarbonate (pH 10.5). The API 3,000 mass spectrometer was equipped with a TurboIonSpray interface and was operated on positive-ion, multiple reaction-monitoring (MRM) mode. The mass transitions monitored were m/z 426.3-->100.0, m/z 411.3-->100.0 and m/z 268.3-->116.1 for tiloronoxim, tilorone and the IS, respectively. The assay exhibited a linear dynamic range of 1-100 ng/ml for both tiloronoxim and tilorone based on the analysis of 0.2 ml aliquots of urine. The lower limit of quantification was 1 ng/ml for both compounds. Acceptable precision and accuracies were obtained for concentrations over the standard curve ranges. Run time of 8 min for each injection made it possible to analyze a high throughput of urine samples. The assay has been successfully used to analyze human urine samples from healthy volunteers.  相似文献   

7.
Glipizide and rosiglitazone are widely used to treat Type 2 diabetes. In order to investigate drug-drug protein binding interaction between glipizide and rosiglitazone, a method was developed and validated for simultaneously determining the free (unbound) fraction of glipizide and rosiglitazone in plasma employing equilibrium dialysis for the separation of free drug and liquid chromatography-tandem mass spectrometry (LC-MS/MS) for quantitation. Post-dialysis human plasma or buffer samples of 0.2 ml were extracted using a liquid-liquid extraction procedure and analyzed by a high performance liquid chromatography electrospray tandem mass spectrometer system. The compounds were eluted isocratically on a Zorbax SB-Phenyl column, ionized using an atmospheric pressure electrospray ionization source and analyzed in positive ion mode with multiple reaction monitoring. The ion transitions monitored were m/z 446-->321 for glipizide, m/z 358-->135 for rosiglitazone, and m/z 271-->155 for tolbutamide (internal standard, IS). The chromatographic run time was 5 min per injection, with retention times of 2.3, 3.4 and 2.3 min for glipizide, rosiglitazone and IS, respectively. The calibration curves of glipizide and rosiglitazone were over the range of 1-2000 ng/ml (r(2)>0.9969) in the combined matrix of human plasma and isotonic sodium phosphate buffer (1:1, v/v). The inter-assay precision and accuracy of the quality control samples were <10.9% of coefficient of variability and >93.5% and 94.5% of nominal concentration for glipizide and rosiglitazone, respectively. The lower limit of quantitation of both glipizide and rosiglitazone was 1.0 ng/ml. Both glipizide and rosiglitazone bound to plasma protein extensively (>99% bound). Glipizide and rosiglitazone free fraction averaged 0.678+/-0.071 and 0.389+/-0.061%, respectively, at plasma concentration of 1000 ng/ml. This developed method proves reproducible and sensitive and its application to clinical samples is also reported.  相似文献   

8.
A rapid, sensitive and selective LC-MS/MS method was developed and validated for the quantification of aniracetam in human plasma using estazolam as internal standard (IS). Following liquid-liquid extraction, the analytes were separated using a mobile phase of methanol-water (60:40, v/v) on a reverse phase C18 column and analyzed by a triple-quadrupole mass spectrometer in the selected reaction monitoring (SRM) mode using the respective [M+H]+ ions, m/z 220-->135 for aniracetam and m/z 295-->205 for the IS. The assay exhibited a linear dynamic range of 0.2-100 ng/mL for aniracetam in human plasma. The lower limit of quantification (LLOQ) was 0.2 ng/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated LC-MS/MS method has been successfully applied to study the pharmacokinetics of aniracetam in healthy male Chinese volunteers.  相似文献   

9.
An HPLC/MS/MS method for determination of butenafine hydrochloride in human plasma with testosterone propionate as the internal standard (IS) was developed and validated. Plasma samples were extracted with an n-hexane/diethyl ether (1:2, v/v) mixture and separated using a C(18) column by a gradient elution with the mobile phase containing acetonitrile and 5mM ammonium acetate buffer. Quantification was performed using multiple reaction monitoring (MRM) mode with transition of m/z 318.4→141.0 for butenafine hydrochloride and m/z 345.5→97.0 for testosterone propionate (IS). This method was validated in terms of specificity, linearity, precision, accuracy, and stability. The lower limit of quantification (LLOQ) of this method was 0.0182 ng/ml and the calibration curve was linear over the 0.0182-1.82 ng/ml. The intra- and inter-run coefficient of variance was less than 11.53% and 10.07%, respectively. The samples were stable under all the tested conditions. The method was successfully applied to study the pharmacokinetics of butenafine hydrochloride in healthy Chinese volunteers following its topical administration.  相似文献   

10.
A highly sensitive and specific LC-MS method was developed and validated for the quantification of digoxin in human plasma and urine using d5-dihydrodigoxin as internal standard (IS). The assay procedure involved extraction of digoxin and IS from human plasma with chloroform-isopropanol (95:5, v/v). Chromatogrphic separation was achieved on a Spherisorb ODS2 column using a gradient mobile phase with 5 mmol/L ammonium acetate in water with 1% acetic acid and acetonitrile. The mass spectrometer was operated in the selected ion monitoring mode using the respective [M+K](+) ions, m/z 819.4 for digoxin and m/z 826.4 for IS. The method was proved to be accurate and precise at linearity range of 0.12-19.60 ng/mL in plasma with a correlation coefficient (r(2)) of >or=0.9968 and 1.2-196.0 ng/mL in urine. The limit of quantification achieved with this method was 0.12 ng/mL in plasma and 1.2 ng/mL in urine. The intra- and inter-assay precision and accuracy values were found to be within the assay variability limits as per the FDA guidelines. The developed assay method was successfully applied to a pharmacokinetic study in human volunteers following intravenous administration of digoxin.  相似文献   

11.
A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) method has been developed and validated for simultaneous quantification of venlafaxine (VEN) and O-desmethyl venlafaxine (ODV) in human plasma. The analytes were extracted from human plasma by using solid-phase extraction (SPE) technique. Escitalopram (ESC) was used as the internal standard. A Betasil C18 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The mass transition ion-pair has been followed as m/z 278.27-->121.11 for VEN, m/z 264.28-->107.10 for ODV and m/z 325.00-->262.00 for ESC. The method involves a solid phase extraction from plasma, simple isocratic chromatography conditions and mass spectrometric detection that enables detection at nanogram levels. The proposed method has been validated with linear range of 3-300 ng/ml for VEN and 6-600 ng/ml for ODV. The intrarun and interrun precision and accuracy values are within 10%. The overall recoveries for VEN and ODV were 95.9 and 81.7%, respectively. Total elution time as low as 3 min only.  相似文献   

12.
A sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the determination of hydroxysafflor yellow A (HSYA) in human plasma. HSYA was extracted from human plasma by using solid-phase extraction technique. Puerarin was used as the internal standard. A Shim-pack VP-ODS C(18) (150mm x 4.6mm, 5 microm) column and isocratic elution system composing of methanol and 5mM ammonium acetate (80:20, v/v) provided chromatographic separation of analytes followed by detection with mass spectrometry. The mass transition ion-pair was followed as m/z 611.19-->491.19 for HSYA and m/z 415.19-->295.10 for puerarin. The proposed method has been validated with a linear range of 1-1000 ng/ml for HSYA with a correlation coefficient >/=0.999. The lower limit of quantitation was 1 ng/ml. The intra-batch and inter-batch precision and accuracy were within 10%. The average extraction recovery was 81.7%. The total run time was 5.5 min. The validated method was successfully applied to the study on pharmacokinetics of HSYA in 12 healthy volunteers after a single oral administration of safflower oral solution containing 140 mg of HSYA.  相似文献   

13.
A rapid, selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method with electrospray ionization (ESI) was developed and validated for the simultaneous determination of pitavastatin and its lactone in human plasma and urine. Following a liquid-liquid extraction, both the analytes and internal standard racemic i-prolact were separated on a BDS Hypersil C(8) column, using methanol-0.2% acetic acid in water (70: 30, v/v) as the mobile phase. The mass spectrometer was operated in multiple reaction monitoring (MRM) mode using the transition m/z 422.4-->m/z 290.3 for pitavastatin, m/z 404.3-->m/z 290.3 for pitavastatin lactone and m/z 406.3-->m/z 318.3 for the internal standard, respectively. Linear calibration curves of pitavastatin and its lactone were obtained in the concentration range of 1-200 ng/ml, with a lower limit of quantitation of 1 ng/ml. The intra- and inter-day precision values were less than 4.2%, and accuracies were between -8.1 and 3.5% for both analytes. The proposed method was utilized to support clinical pharmacokinetic studies of pitavastatin in healthy subjects following oral administration.  相似文献   

14.
The validation of a LC/MS/MS method for the determination of 8-methoxypsoralen (8-MOP) in human plasma and microdialysates after topical application is described. Plasma samples were extracted by liquid-liquid extraction with diisopropylether using 4,5',8-trimethylpsoralen (TMP) as internal standard. Chromatographic separation of plasma sample extracts was carried out using a short narrow-bore Nucleosil C18 column (30 mm x 2.0 mm i.d.) with acetonitrile/(2 mM ammonium acetate buffer, 2 mM acetic acid) (80:20, v/v). For mass spectrometric analysis an API 3000 triple quadrupole mass spectrometer was employed. The mass transitions used were m/z 217.2-->174.0 for 8-MOP and m/z 229.1-->142.1 for TMP. Microdialysis samples diluted with an equal amount of acetonitrile did not require any extraction and were analyzed directly on a narrow-bore Nucleosil C18 column (70 mm x 2.0mm i.d.) with acetonitrile/(2 mM ammonium acetate buffer, 2 mM acetic acid) (50:50, v/v) with the mass transition m/z 217.2-->174.0. The assays were validated over the concentration ranges of 0.5-50 ng/ml for plasma samples and 0.25-50 ng/ml for microdialysates, respectively.  相似文献   

15.
The method describes quantification and confirmation of flunixin in equine plasma by liquid chromatography-quadrupole time-of-flight mass spectrometry (LC/Q-TOF/MS/MS). Samples were screened by enzyme-linked immunosorbent assay (ELISA) and only those samples presumptively declared positive were subjected to quantification and confirmation for the presence of flunixin by this method. The method is also readily adaptable to instrumental screening for the analyte. Flunixin was recovered from plasma by liquid-liquid extraction (LLE). The sample was diluted with 2 ml saturated phosphate buffer (pH 3.10) prior to LLE. The dried extract was reconstituted in acetonitrile:water:formic acid (50:50:0.1, v/v/v) and subsequently analyzed on a Q-TOF tandem mass spectrometer (Micromass) operated under electrospray ionization positive ion mode. The concentration of flunixin was determined by the internal standard (IS) calibration method using the peak area ratio with clonixin as the IS. The limits of detection (LOD) and quantification (LOQ) for flunixin in equine plasma were 0.1 and 1 ng/ml, respectively, whereas the limit of confirmation (LOC) was 2.5 ng/ml. The qualifying ions for the identification of flunixin were m/z 297 [M+H](+), 279 (BP), 264, 259, 239 and those for clonixin (IS) were m/z 263 [M+H](+), 245 (BP) and 210. The measurement uncertainty about the result was 8.7%. The method is simple, sensitive, robust and reliably fast in the quantification and confirmation of flunixin in equine plasma. Application of this method will assist racing authorities in the enforcement of tolerance plasma concentration of flunixin in the racehorse on race day.  相似文献   

16.
Liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) was used for a quantitative estimation of entecavir (EV) in human plasma using lamivudine (LM) as internal standard (IS). The method herein described is simple, sensitive, and specific. Chromatographic separation was performed on XBridge-C18, 4.6 mm × 50 mm, 5-μm column with an isocratic mobile phase composed of 10 mM ammonium hydrogen carbonate (pH 10.5):methanol (85:15 v/v), pumped at 0.3 ml/min. EV and LM were detected using proton adducts at m/z 278.1→152.1 and 230.2→112.0 in multiple reaction monitoring (MRM) positive mode. Solid phase extraction method was employed in the extraction of EV and LM from the biological matrix. This method was validated over a linear concentration range of 50.0-20000.0 pg/ml with a correlation coefficient (r) ≥0.9983. Intra and inter-day precision of EV was found within the range of 1.2-4.2 for EV and 4.4-4.5 for LM. EV was stable throughout three freeze/thaw cycles, bench top and postoperative studies. This method was successfully used in the analysis of plasma samples following oral administration of EV (0.5 mg) in 26 healthy human volunteers.  相似文献   

17.
本文建立了一种快速、高灵敏的HPLC-MS/MS法用于检测人血浆中的草乌甲素浓度。血浆样品采用沃特斯HLB小柱进行固相萃取,汉邦C18色谱柱(150 mm×4.6 mm,5μm)进行分离,流动相为甲醇∶水(85∶15,v/v),水相含10 mmol/L的醋酸铵和0.1%的甲酸。采用ESI源和多反应监测(MRM)的方式进行检测,草乌甲素及内标的反应离子对分别为644.4/584.4和237.2/194.2,草乌甲素血药浓度在0.010~1.0 ng/mL范围内线性关系良好,最低定量限为0.010 ng/mL可以满足口服0.4 mg草乌甲素后血药浓度的检测,日内日间及质控样品精密度及准确度均在允许范围内。本检测方法被成功的应用在中国健康志愿者生物等效性研究中,20名志愿者口服0.4 mg草乌甲素试验制剂和参比制剂后主要药代动力学参数分别如下:Cmax(0.325±0.110),(0.323±0.115)ng/mL;AUC0-16(1.627±0.489),(1.732±0.556)ng.h/mL;AUC0-∞(1.730±0.498),(1.831±0.562)ng.h/mL;t1/2(4.26±0.95),(3.80±0.90)h;Tmax(1.34±0.54),(1.83±0.99)h。  相似文献   

18.
A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantitation of tadalafil (I) in human plasma, a new selective, reversible phosphodiesterase 5 inhibitor. The analyte and internal standard (sildenafil, II) were extracted by liquid-liquid extraction with diethyl ether/dichloromethane (70/30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on reverse phase Xterra MS C18 column with a mobile phase of 10mM ammonium formate/acetonitrile (10/90, v/v, pH adjusted to 3.0 with formic acid). The protonate of analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 390.4 --> 268.0 and m/z 475.5 --> 58.3 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 10-1000 ng/mL for tadalafil in human plasma. The lower limit of quantitation was 10 ng/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. Run time of 1.2 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

19.
A sensitive high performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS) assay was developed to determine raltitrexed in human plasma. After addition of benazeprilat as the internal standard (IS), methanol was used to produce a protein-free extract. Chromatographic separation was achieved with a Zorbax SB-C18 column (Narrow-Bore 2.1 mmx150 mm, 5-microm) using a mobile phase of acetonitrile-water containing 0.1% formic acid and 2% methanol (21.9:78.1, v/v). Raltitrexed was determined with electrospray ionization-mass spectrometry. HPLC-ESI-MS was performed in the selected ion monitoring (SIM) mode using target ions at [M+H]+ m/z 459.1 for raltitrexed and [M+H]+ m/z 397.1 for IS. Calibration curves were linear over the range of 2.0-3000 ng/ml. The lower limit of quantification was 2.0 ng/ml. The intra- and inter-batch variability values were less than 6.7% and 10.3%, respectively. The mean plasma extraction recovery of raltitrexed was in the range of 85.2-91.1%. The method was successfully applied to determine the plasma concentrations of raltitrexed in eight Chinese colorectal cancer patients.  相似文献   

20.
Flurogestone (FGA) is a synthetic progesterone, with a progestational action higher than that of progesterone itself. It is intended for vaginal use in large animals to induce oestrus synchronization. A quantitative method for the analysis of flurogestone acetate (FGA) in ovine plasma by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) has been developed. After the incorporation of megestrol acetate (MGA) as internal standard (IS) and followed by a liquid-liquid extraction from plasma, FGA and MGA were chromatographed using a reverse-phase HPLC column and detected by tandem mass spectrometry with a TurboIonSpray source. Multiple reaction-monitoring (MRM) mode was used for the quantitative determination of FGA in ovine plasma. The precursor ions [M+H](+) at m/z 407.2 and 385.1 for FGA and MGA, respectively, produced product ions at m/z 267.1/285.1 for FGA and m/z 267.1/224.0 for MGA. The validated concentration range was 0.2-5.0 ng/ml based on 500 microl plasma aliquots. The lower limit of quantitation was 0.2 ng/ml. Fully validated selectivity, accuracy, precision and reproducibility criteria for routine use in pharmacokinetic studies were demonstrated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号