首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 173 毫秒
1.
We report here the characterisation of a preparation of diphtheria toxoid, adsorbed, and its calibration by twenty laboratories in fourteen countries in terms of the Second International Standard (I.S.) for Diphtheria Toxoid, Adsorbed, coded sample A (DIXA) using the established World Health Organisation (WHO)/European Pharmacopoeia (Ph Eur) challenge methods. The replacement standard preparation was found to have a unitage of 160 IU/ampoule on the basis of its calibration by in vivo bioassay. Stability was assessed within the collaborative study, and as part of candidate characterisation. Results suggest that the replacement standard will have satisfactory stability. This study also provided an opportunity to investigate serology as alternative to in vivo bioassay for potency testing of diphtheria vaccines. Six laboratories participated by performing serology according to in-house protocol. The calibration of the replacement standard in a mouse Vero cell assay gave a significantly higher results than in the established WHO/Ph Eur methods. Based on the results of this study and with the agreement of participants, the candidate standard was established as the Third International Standard for Diphtheria Toxoid, Adsorbed (coded 98/560) by the WHO Expert Committee of Biological Standardization in October 1999. The same preparation was also established as the second Ph Eur Biological Reference Preparation (Ph Eur BRP, batch no. 3) by the Steering Committee of the Biological Standardisation Programme of the European Directorate for the Quality of Medicines and approved by the European Pharmacopoeia Commission.  相似文献   

2.
We present the results of a collaborative study for the establishment of a replacement International Standard (IS) for Tetanus Toxoid Adsorbed. Two candidate preparations were included in the study, one of which was established as the 4th IS for Tetanus Toxoid Adsorbed at the WHO Expert Committee on Biological Standardization meeting in October 2010. This preparation was found to have a unitage of 490 IU/ampoule, based on calibration in guinea pig challenge assays. Results from mouse challenge assays suggest that the relative performance of two candidate preparations may differ significantly between guinea pigs and mice. The authors note that the number of laboratories that performed guinea pig challenge assays, which are used to calibrate and assign IU, is much lower than in previous collaborative studies and this may have implications for calibration of replacement standards in the future. The issue of assigning separate units to the IS for guinea pig and mouse assays is discussed. The study also assessed performance of the replacement standard in serological assays which are used as alternative procedures to challenge assays for tetanus potency testing. Results suggest that the replacement standard is suitable for use as the reference vaccine in serological assays.  相似文献   

3.
Here we report the characterisation of a preparation of tetanus toxoid, adsorbed, and its calibration by 27 laboratories in 19 countries in a joint international collaborative study co-sponsored by World Health Organization (WHO) Expert Committee of Biological Standardization (ECBS) and the European Biological Standardisation Programme of European Directorate for the Quality of Medicines (EDQM), Council of Europe. Calibration was in terms of the Second International Standard (I.S.) for Tetanus Toxoid, Adsorbed, by the established WHO/European Pharmacopoeia (Ph Eur) challenge methods. The replacement standard preparation was found to have a unitage of 469 IU/ampoule on the basis of its calibration in guinea-pigs and 496 IU/ampoule on the basis of its calibration in mice. Assessment, both within the collaborative study and as part of candidate characterisation, indicated satisfactory stability of the candidate preparation. This study also provided some information on the effect of mouse strain on potency testing of tetanus vaccines. A limited assessment of the impact of the replacement standard on testing of current production batches of vaccines was also carried out by four manufacturers. This study did not directly address the serological approaches to potency testing. However, one laboratory offered data from mouse serology assay, which gave comparable estimates to in vivo mouse bioassay.Based on the results of this study and with the agreement of participants, the candidate standard was established as the Third International Standard for Tetanus Toxoid, Adsorbed (coded 98/552) by the WHO Expert Committee of Biological Standardization (ECBS) in November 2000. The same preparation was also established as the second Ph Eur Biological Reference Preparation (Ph Eur BRP, batch no. 2) by the Steering Committee of the Biological Standardisation Programme of the EDQM and approved by the European Pharmacopoeia Commission.  相似文献   

4.
J Lyng 《Biologicals》1990,18(1):11-17
The Lf-unit, which is used in the control of diphtheria and tetanus toxoid production and in some countries also to follow immunization of horses for production of antitoxins, has hitherto been defined by means of antitoxin preparations. A diphtheria toxoid and a tetanus toxoid preparation, both freeze-dried, were examined in an international collaborative study for their suitability to serve as reference reagents in the flocculation tests and for defining the Lf-units. It was shown that flocculation tests using the reference toxoids are very reproducible and reliable and the WHO Expert Committee on Biological Standardization established: the toxoid called DIFT as the International Reference Reagent of Diphtheria Toxoid for Flocculation Test with a defined content of 900 Lf-units of diphtheria toxoid per ampoule; and the toxoid called TEFT as the International Reference Reagent of Tetanus Toxoid for Flocculation Test with a defined content of 1000 Lf-units of diphtheria toxoid per ampoule.  相似文献   

5.
The 1st International Reference Reagents (IRR) of Diphtheria and Tetanus Toxoids for Flocculation Test (DIFT and TEFT) were established by the WHO in 1988. These reagents are essential for the standardization of assays used to calculate Lf units of toxoids. Candidate replacement materials were provided by several European vaccine manufacturers and were formulated and freeze-dried at NIBSC. This paper provides a summary of the results of an international collaborative study including 18 laboratories from 16 countries, which examined the candidate replacement materials in a variety of methods. Materials 02/176 and 04/150 were proposed and adopted by the Expert Committee on Biological Standardization of WHO in October 2007 as 2nd WHO International Standards of Diphtheria and Tetanus Toxoid for use in Flocculation Test. The replacement standards were assigned the value of 1100 and 690Lf/ampoule, respectively, based on results of flocculation tests carried out using provided reagents. Material coded 02/176 fully complied with the WHO specifications for stability, residual moisture content, precision of fill and sterility. Stability of material coded 04/150 was slightly lower than expected but predictions were based only on 2-year data and were to be further monitored, post-adoption.  相似文献   

6.
Tetanus toxoid is a vital primary reference material used for standardization of assays required to establish the antigenic purity of tetanus toxoid for vaccine production. Several formulations were assessed and ampouled fills of each formulation lyophilised. The relative Lf content determined by Ramon flocculation, SRD, and ELISA assays was measured. The stability of the tetanus toxoid activity in each formulation was assessed by accelerated degradation studies. Formulations containing glycine were not suitable in flocculation tests but both sorbitol and trehalose formulations were. The trehalose/sodium chloride formulation had a good appearance, showed good activity in all assays and maintained its activity best under stress conditions. This formulation has been applied to a large scale batch of ampoules prepared as a WHO candidate replacement standard, evaluated in a collaborative study and accepted as a replacement WHO IS for use in flocculation test (WHO ECBS, October 2007, ref no BS/07.2061). The stability of this formulation was also excellent for the large scale batch. The benefits of using thermal analysis and freeze drying microscopy coupled with small scale lyophilisation trials in order to screen formulations for the preparation of batches of biological reference materials are demonstrated.  相似文献   

7.
The 1st International Standard for Diphtheria Antitoxin Human (coded 10/262) was established by the World Health Organization Expert Committee on Biological Standardization in 2012. This paper describes the production, characterization and calibration of the new standard which is intended for use in the standardization of assays used to measure diphtheria antibody responses in human serum. The new standard was calibrated in terms of the International Standard for Diphtheria Antitoxin Equine in an international collaborative study. A total of 8 participants from 8 different countries performed in vivo and/or in vitro toxin neutralization tests and returned data that was used to assign units to the proposed new standard. The new standard has a diphtheria antitoxin potency of 2 IU/ampoule and is predicted to be stable. A follow up study was performed to assess commutability of the new standard. The follow up study was an existing external quality assessment, modified to include the new standard. Results obtained suggest that the new standard is commutable, showing comparable behaviour to native human serum samples in the majority of the assays compared, and is therefore suitable for use as a reference preparation in assays used to measure the level of anti-diphtheria antibodies in human serum.  相似文献   

8.
Whole cell pertussis vaccine is still widely used in many countries. An International Standard is needed for its potency control. The Third International Standard for Pertussis Vaccine was prepared about 40 years ago and its replacement was recommended by the Expert Committee for Biological Standardisation (ECBS) of the WHO. Material in ampoules coded 94/532 was prepared as a candidate replacement and has been evaluated in international collaborative studies which consisted of two parts. The first part, to assess the suitability of the candidate standard by comparing it with the Second International Standard for Pertussis Vaccine (IS2) involved 14 laboratories in 11 countries. The second part to compare the candidate standard with the Third International Standard for Pertussis Vaccine (IS3) involved 16 laboratories in 14 countries. Since 1995 various other studies have included the international standards and the results of these are also considered in assessing likely continuity of the IU for potency of whole cell pertussis vaccine. The preparation in ampoules coded 94/532 was adopted by the WHO ECBS in October 2006 as the 4th International Standard for whole cell pertussis vaccine and assigned an activity of 40 IU per ampoule on the basis of the studies reported here.  相似文献   

9.
The main purpose of these investigations was the comparison of two potency tests of Tetanus Toxoid. It was found that two doses test with reduced number of animals can be used in assay of different vaccines containing Tetanus component. One dose test is agreeable with requirements of WHO. It is credible and not complicated method of estimation Diphtheria and Tetanus Toxoids. This test required minimal number of animals.  相似文献   

10.
A collaborative study was organised by the European Directorate For the Quality of Medicines (EDQM) to assess the suitability of a candidate mouse antiserum as a European Pharmacopoeia Biological reference preparation (BRP) for acellular pertussis vaccine potency testing. The candidate antiserum was obtained by immunising mice with a five-component acellular pertussis vaccine: pertussis toxin (PT), filamentous haemagglutinin (FHA), pertactin (PRN) and Fimbrial 2/Fimbrial 3 (Fim 2&3).The study has been divided into two separate phases. Phase I was a pre-qualification study including three laboratories. This phase was aimed at pre-qualifying the candidate BRP (cBRP) and at documenting the impact of differences in the antibody detection methodology enzyme linked immunosorbent assay (ELISA) procedures on results of pertussis antisera calibration versus the currently used standard US standard pertussis antiserum (mouse) Lot 1 (SPAM-1) (United States Food and Drug Administration (USFDA) reference serum) and the cBRP. As no significant difference between the antibody titres determined by using the different ELISA methodologies was found, a large-scale study enrolling 13 laboratories (Phase II) was carried out, each participant performing its in-house methodology. Its aim was to calibrate the cBRP (in terms of the SPAM-1 reference) and to demonstrate its equivalence or superiority to internal references. The study showed that there was no difference in positive sera titres expressed relative to their corresponding internal reference (homologous situation) or the proposed standard (heterologous situation) reference. The cBRP can, therefore, reliably act as replacement for the in-house reference preparations. Further analysis of the outcome of this study enabled to assign to the cBRP a potency of 39, 138, 34 and 56 ELISA unit per millilitre, respectively, to its anti-PT, anti-FHA, anti-PRN and anti-Fim 2&3 antibody contents. The cBRP has been adopted by the European Pharmacopoeia Commission at its June 2000 session as Bordetella pertussis mouse anti-serum Ph Eur. BRP batch 1.  相似文献   

11.
Due to the increase in the number of infliximab products, the need for global harmonization of the bioactivity of this monoclonal antibody was recognized by the World Health Organization (WHO). In response, the National Institute for Biological Standards and Control (NIBSC) developed the first international standard (IS) for infliximab, which targets tumour necrosis factor (TNF). Each ampoule is assigned values of 500 IU of TNF neutralizing activity and 500 IU of binding activity. Two preparations of infliximab were formulated and lyophilized at NIBSC prior to evaluation in a collaborative study for their suitability to serve as an IS for the in vitro biological activity of infliximab. The study involved participants using in vitro cell-based bioassays (TNF neutralization, antibody-dependent cell-mediated cytotoxicity and complement-dependent cytotoxicity) and binding assays. The results of this study showed that the candidate preparation, coded 16/170, is suitable as an IS for infliximab bioactivity. This infliximab IS from NIBSC, is intended to support in vitro bioassay calibration and validation by defining international units of bioactivity. The proposed unitages, however, are not intended to revise product labelling or dosing requirements, as any decisions regarding this relies solely with the regulatory authorities. Furthermore, the infliximab IS is not intended for determining the specific activity of products, nor to serve any regulatory role in defining biosimilarity. We briefly discuss the future use of WHO international standards in supporting the global harmonisation of biosimilar infliximab products.  相似文献   

12.
On the basis of the experimentally established dependence of the degree of binding of diphtheria toxoid with standard diphtheria antitoxin on the duration of their joint incubation with the maximum binding occurring in 3-4 hours of incubation at 37 degrees C, the method of the in vitro determination of the antigenic activity of diphtheria toxoid in liquid and adsorbed preparations is proposed. The method is based on the principle of double binding with the use of diphtheria antigenic (toxoid) erythrocyte diagnosticum. The antigenic activity of diphtheria toxoid, evaluated by the degree of its maximum binding with diphtheria antitoxin, correlated with its antitoxin-binding activity in animal experiments and did not correlate with its flocculating activity. The antigenic activity of diphtheria toxoid in adsorbed preparations, evaluated by their maximum binding with standard diphtheria antitoxin, was shown to be closely related to the immunogenic potency of these vaccines in animals.  相似文献   

13.
Clostridium botulinum produces the most potent known toxins, with seven distinct serotypes currently defined (A-G). These toxins can cause a life threatening systemic toxicity whether through natural causes such as food poisoning, infant botulism, wound botulism, or through use as bio-terror agents (e.g. inhalational botulism). It was realised early on that standard reference botulinum antitoxins were required to reduce the variation between assays and ensure a consistent potency of therapeutic antitoxins and vaccines, and to define the serotype. This led to the International Unit being defined by the World Health Organisation (WHO) in the 1960s with the establishment of the first International Standards (IS) for serotypes A-F. Since then botulinum antitoxin ISs have been used world wide as the 'yard stick' to measure the neutralising potency of antitoxins. These primary WHO ISs are used to calibrate in house working reagents that are more extensively utilised. A definition of the International Unit for serotype G antitoxin has yet to be defined or accepted by the WHO and urgently needs addressing. However, before September 11th 2001 there was very little interest in botulinum antitoxin IS and as a result stocks of most of the original preparations are now completely exhausted or depleted and replacements long overdue. We have reviewed the extensive history and availability of the primary WHO ISs and interim materials. All type A and B antitoxin materials were recently assayed and their relative activities confirmed against the original IS preparations. The recent increase in demand for these materials has further exacerbated the shortage. We describe here the production and characterization of stable freeze dried potential candidate replacements along with a new prospective first IS for type G antitoxin. Available toxin A reference preparations are also briefly reviewed.  相似文献   

14.
J Lyng  I Heron 《Biologicals》1992,20(2):101-108
Two diphtheria toxoid preparations were compared in potency assays in guinea-pigs using different methods for evaluation of the responses to vaccination. The methods used were the direct skin challenge (Schick test) and ELISA and VERO cell titration of antibodies. The different evaluation methods resulted in the same relative potencies between the toxoids. It was observed that when first-vaccination sera were compared with a second-vaccination serum, the relative antibody concentration depended on whether ELISA or VERO cell titration was used.  相似文献   

15.
A radioimmunodiffusion technique for detecting low levels of diphtheria antitoxin was developed. Diphtheria toxoid was labelled with 125I to facilitate detection of lines of precipitation by the use of X-ray film, the lower limit of detection being 0.001 unit per millilitre of diphtheria antitoxin.  相似文献   

16.
Lukas Bruckner 《Biologicals》2013,41(5):303-304
In Europe, the legal basis for requirements for medicinal products is described in the European Pharmacopoeia (Ph. Eur.) In the European Union, the Ph. Eur. is supplemented by several guidelines issued by the European Medicines Agency. Immunological veterinary products must comply with the Ph. Eur. monograph on veterinary vaccines and the accompanying texts, as well as specific monographs. The Ph. Eur. includes monographs on canine leptospirosis and bovine leptospirosis vaccines (inactivated). Both monographs require that an immunogenicity test be performed once in the target species during the life of a vaccine. The hamster challenge test is applied for batch potency testing of canine vaccines. Alternatively, serological tests or suitable validated in vitro tests to determine the content of one or more antigenic components indicative of protection may be performed. Vaccines for use in cattle are tested in a serological test in guinea pigs. The acceptance criteria in alternative tests are set with reference to a batch of vaccine that has given satisfactory results in the immunogenicity test. At a January 2012 European workshop, the suitability of the hamster potency test was questioned and unanimous agreement was reached that moving toward complete in vitro testing is possible and should be promoted.  相似文献   

17.
Nucleic acid amplification technique (NAT)-based assays (referred to here as NAT assays) are increasingly used as an alternative to culture-based approaches for the detection of mycoplasma contamination of cell cultures. Assay features, like the limit of detection or quantification, vary widely between different mycoplasma NAT assays. Biological reference materials may be useful for harmonization of mycoplasma NAT assays. An international feasibility study included lyophilized preparations of four distantly related mycoplasma species (Acholeplasma laidlawii, Mycoplasma fermentans, M. orale, M. pneumoniae) at different concentrations which were analyzed by 21 laboratories using 26 NAT assays with a qualitative, semiquantitative, or quantitative design. An M. fermentans preparation was shown to decrease the interassay variation when used as a common reference material. The preparation was remanufactured and characterized in a comparability study, and its potency (in NAT-detectable units) across different NATs was determined. The World Health Organization (WHO) Expert Committee on Biological Standardization (ECBS) established this preparation to be the “1st World Health Organization international standard for mycoplasma DNA for nucleic acid amplification technique-based assays designed for generic mycoplasma detection” (WHO Tech Rep Ser 987:42, 2014) with a potency of 200,000 IU/ml. This WHO international standard is now available as a reference preparation for characterization of NAT assays, e.g., for determination of analytic sensitivity, for calibration of quantitative assays in a common unitage, and for defining regulatory requirements in the field of mycoplasma testing.  相似文献   

18.
Yellow fever vaccines are routinely assayed by plaque assay. However, the results of these assays are then converted into mouse LD(50) using correlations/conversion factors which, in many cases, were established many years ago. The minimum required potency in WHO Recommendations is 10(3) LD(50)/dose. Thirteen participants from 8 countries participated in a collaborative study whose aim was to assess the suitability of two candidate preparations to serve as an International Standard for yellow fever vaccine. In addition, the study investigated the relationship between the mouse LD(50) test and plaque forming units with a view to updating the WHO recommendations. Plaque assays were more reproducible than mouse assays, as expected. Differences in sensitivities of plaque assays were observed between laboratories but these differences appear to be consistent within a laboratory for all samples and the expression of potency relative to the candidate standard vaccine improved the reproducibility of assays between laboratories. However, the use of potencies had little effect on the between laboratory variability in mouse LD(50) assays. There appears to be a consistent relationship between overall mean LD(50) and plaques titre for all study preparations other than sample E. The slope of the correlation curve is >1 and it would appear that 10(3) LD(50) is approximately equivalent to 10(4) plaque forming units (PFU), based on the overall means of all laboratory results. The First International Standard for yellow fever vaccine, NIBSC Code 99/616, has been established as the First International Standard for yellow fever vaccine by the Expert Committee of Biological Standards of the World Health Organisation. The International Standard has been arbitrarily assigned a potency of 10(4.5) International Units (IU) per ampoule. Manufacturers and National Control Laboratories are including the First International Standard for yellow fever vaccine in routine assays so that the minimum potency in IU of vaccines released for use and which meet the current minimum potency of 10(3) LD(50) in mouse assays, can be determined. These data will be analysed before a review of the WHO requirements, including the minimum potency per dose, is undertaken.  相似文献   

19.
Adsorbed DPT vaccine and adsorbed DT toxoids with normal and reduced antigen content were used for the immunization of rabbits. The levels of IgM and IgG and the dynamics of antibodies to diphtheria and tetanus toxins and to Bordetella pertussis in the blood sera of the animals were studied in the postvaccinal period (on days 15 and 34). This study revealed that the reduction of the antigen content of adsorbed DT toxoid to 5 Lf of diphtheria toxoid and 5 binding units of tetanus toxoid did not decrease the capacity of the preparation for increasing the levels of IgG and IgM, antibodies to diphtheria and tetanus toxins in the sera of the rabbits. The reduced content of these toxoids in adsorbed DPT vaccine did not affect its capacity for inducing the enhanced synthesis of IgG, antibodies to diphtheria and tetanus toxins, while the production of IgM and IgA remained unchanged. At the same time an increase in the titers of antibodies to B. pertussis in the animals was less pronounced than that observed after the injection of commercial adsorbed DPT vaccine. Additional investigations are necessary in order to establish the protective potency of the pertussis component in adsorbed DPT vaccine with the reduced content of toxoids and to find out the optimum antigenic composition for this preparation.  相似文献   

20.
本文对吸附精制百白破混合制剂的不同配方进行了实验,结果表明,新一代吸附精制百白破混合制剂最佳配方为:精制百日咳菌苗18μgPN/ml、精制白喉类毒素为30Lf/ml、精制破伤风类毒素为10Lf/ml。由该配方组成的吸附精制百白破混合制剂,其中百日咳菌苗的毒性试验BWDU/ml、LPU/ml、HSU/ml三种指标均符合制检规程要求。其效力单位(IU/ml)超过规程要求一倍以上,精制白喉和破伤风类毒素的安全试验均符合规程要求,白类效力试验≥80-100%,破类效力试验≥0.5-4.5IU/ml。上述结果说明本文提出的配方作为新一代精制百白破混合制剂的配方是适宜和实用的。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号