首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper presents specific and sensitive high-performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS) assays for the quantification of the novel anticancer agent eribulin in human plasma, whole blood, urine and faeces. These assays, developed to support clinical pharmacological studies with the drug, quantify eribulin concentration ranges of 0.2-100ng/mL for plasma, 0.5-100 ng/mL for whole blood and urine and 0.1-25 μg/g for faeces, using sample volumes of 500 μL or 250 μg (faeces). Samples were prepared with liquid-liquid extraction, separated on a C18 column with gradient elution and analysed with a triple quadrupole MS, in positive ion mode. A structural analogue of eribulin was used as internal standard for the quantification. The assays were linear with correlation coefficients (r(2)) of 0.99 and better, whereby the deviation from nominal concentrations ranged from -8.2 to 8.9% with CV values of maximally 14.2%. Stability assessments demonstrated that eribulin is stable at -20°C in plasma, whole blood, urine and faeces for at least 38, 4, 10.5 and 5 months, respectively. In conclusion, the validation results show that the assays are specific and accurate and can therefore adequately be applied to support clinical studies of eribulin.  相似文献   

2.
A liquid chromatography/electrospray ionization mass spectrometry (LC-ESI-MS) method was developed for the first time for the determination of ibogaine and noribogaine in human plasma and whole blood. The method involved solid phase extraction of the compounds and the internal standard (fluorescein) from the two matrices using OasisHLB columns. LC separation was performed on a Zorbax eclipse XD8 C8 column (5 microm) with a mobile phase of acetonitrile containing 0.02% (v/v) trimethylamine and 2mM ammonium formate buffer. MS data were acquired in single ion monitoring mode at m/z 311.2, 297.2 and 332.5 for ibogaine, noribogaine and fluorescein, respectively. The drug/internal standard peak area ratios were linked via a quadratic relationship to plasma (0.89-179 microg/l for ibogaine; 1-200 microg/l for noribogaine) and to whole blood concentrations (1.78-358 microg/kg for ibogaine; 2-400 microg/kg for noribogaine). Precision ranged from 4.5 to 13% and accuracy was 89-102%. Dilution of the samples had no influence on the performance of the method. Extraction recoveries were > or =94% in plasma and > or =57% in whole blood. The lower limits of quantitation were 0.89 microg/l for ibogaine and 1 microg/l for noribogaine in plasma, and 1.78 microg/kg for ibogaine and 2 microg/kg for noribogaine in whole blood. In frozen plasma samples, the two drugs were stable for at least 1 year. In blood, ibogaine and noribogaine were stable for 4h at 4 degrees C and 20 degrees C and 2 months at -20 degrees C. The method was successfully used for the analysis of a poisoning involving Tabernanthe iboga root.  相似文献   

3.
A sensitive and reliable method for the determination of gamma-aminobutyric acid (GABA), a major inhibitory neurotransmitter, in human plasma and cerebrospinal fluid (CSF) has been developed. The method is based on capillary liquid chromatography (LC)/tandem mass spectrometry (MS/MS) using deuterium-labeled GABA (gamma-aminobutyric acid-2,2-D(2), GABA-d(2)) as internal standard. Pre-column derivatization with 7-fluoro-4-nitrobenzoxadiazole (NBD-F) was deployed, allowing both effective in-line pre-concentration and sensitive tandem MS detection of the analyte. An extraction column (10 mm x 0.25 mm, 7 microm, C(18)) was used for preconcentrating and stacking the sample. Separation was carried out on an analytical column (50 mm x 0.25 mm, 5 microm, C(18)). Characteristic precursor-to-product ion transitions, m/z 267--> 249 (for NBD-GABA) and m/z 269--> 251 (for NBD-GABA-d(2)) were monitored for the quantification. A linear calibration curve from 10 to 250 ng/mL GABA with an r(2) value of 0.9994 was obtained. Detection limit was estimated to be 5.00 ng/mL GABA (S/N = 3). Human plasma and CSF samples were analyzed. The concentrations of GABA were found to be 98.6 +/- 33.9 ng/mL (mean +/- S.D., n = 12), and 44.3 +/- 10.0 ng/mL (n = 6) in plasma and CSF, respectively.  相似文献   

4.
A rapid, sensitive and specific method was developed and validated using LC/MS/MS for determination of sunitinib in human plasma. Sample preparation involved a liquid-liquid extraction by the addition of 0.2mL of plasma with 4.0mL tert-butyl-methyl-ether extraction solution containing 25ng/mL of the internal standard clozapine. Separation of compounds was achieved on a C18 (50mmx2.1mm i.d., 3.5microm) analytical column using a mobile phase consisting of acetonitrile/H20 (65:35, v/v) containing 0.1% formic acid and isocratic flow at 0.150mL/min for 3min. The analytes were monitored by tandem-mass spectrometry with electrospray positive ionization. Linear calibration curves in human plasma were generated over the range of 0.2-500ng/mL with values for the coefficient of determination of >0.9950. Within- and between day precision and accuracy were < or =10%. The method was applied to the quantitation of sunitinib in plasma samples from a patient receiving daily oral therapy with sunitinib.  相似文献   

5.
The validation of a LC/MS/MS method for the determination of 8-methoxypsoralen (8-MOP) in human plasma and microdialysates after topical application is described. Plasma samples were extracted by liquid-liquid extraction with diisopropylether using 4,5',8-trimethylpsoralen (TMP) as internal standard. Chromatographic separation of plasma sample extracts was carried out using a short narrow-bore Nucleosil C18 column (30 mm x 2.0 mm i.d.) with acetonitrile/(2 mM ammonium acetate buffer, 2 mM acetic acid) (80:20, v/v). For mass spectrometric analysis an API 3000 triple quadrupole mass spectrometer was employed. The mass transitions used were m/z 217.2-->174.0 for 8-MOP and m/z 229.1-->142.1 for TMP. Microdialysis samples diluted with an equal amount of acetonitrile did not require any extraction and were analyzed directly on a narrow-bore Nucleosil C18 column (70 mm x 2.0mm i.d.) with acetonitrile/(2 mM ammonium acetate buffer, 2 mM acetic acid) (50:50, v/v) with the mass transition m/z 217.2-->174.0. The assays were validated over the concentration ranges of 0.5-50 ng/ml for plasma samples and 0.25-50 ng/ml for microdialysates, respectively.  相似文献   

6.
Nifedipine (NIF), a calcium channel antagonist, is metabolized primarily by cytochrome P450 (CYP3A4) to dehydronifedipine (DNIF). As such, NIF is often used as a probe drug for determining CYP3A4 activity in human studies. A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated to simultaneously determine NIF and DNIF in human plasma using nitrendipine as the internal standard (IS). After extraction of the plasma samples by ether-n-hexane (3:1, v/v), NIF, DNIF and the IS were subjected to LC/MS/MS analysis using electro-spray ionization (ESI). Chromatographic separation was performed on a Hypersil BDS C(18) column (50 mm x 2.1 mm, i.d., 3 microm). The method had a chromatographic running time of approximately 2.5 min and linear calibration curves over the concentrations of 0.5-100 ng/mL for NIF and DNIF. The recoveries of the one-step liquid extraction method were 81.3-89.1% for NIF and 71.6-80.4% for DNIF. The lower limit of quantification (LLOQ) of the analytical method was 0.5 ng/mL for both analytes. The intra- and inter-day precision was less than 15% for all quality control samples at concentrations of 2, 10, and 50 ng/mL. The validated LC/MS/MS method has been successfully used to study pharmacokinetic interactions of NIF with the herbal antidepressant St. John's wort in healthy volunteers. These results indicated that the developed LC/MS/MS method was efficient with a significantly shorter running time (2.5 min) for NIF and DNIF compared to those methods previously reported in the literature. The presented LC/MS/MS method had acceptable accuracy, precision and sensitivity and was used in a clinical pharmacokinetic interaction study of NIF with St. John's wort, a known herbal inducer of CYP3A4. St. John's wort was shown to induce NIF metabolism with increased plasma concentrations of DNIF.  相似文献   

7.
Glabridin is a major flavonoid included specifically in licorice (Glycyrrhiza glabra L.), and has various physiological activities including antioxidant and anti-inflammatory effects. We have developed and validated an analytical method for determination of glabridin in human plasma by solid-phase extraction (SPE) and LC-MS/MS. Glabridin was extracted from plasma by SPE using a C8 cartridge and analyzed by LC-MS/MS using mefenamic acid as an internal standard (IS). The analyte were separated by a C18 column on LC, and monitored with a fragment ion of m/z 201 formed from a molecular ion of m/z 323 for glabridin and that of m/z 196 from m/z 240 for IS during negative ion mode with tandem MS detection. The lower limit of quantitation (LLOQ) of glabridin was 0.1 ng/mL in plasma, corresponding to 1.25 pg injected on-column. The calibration curves exhibited excellent linearity (r>0.997) between 0.1 and 50 ng/mL. Precision and accuracy were <17 and <+/-7% at LLOQ, and <11 and <+/-5% at other concentrations. Glabridin was recovered >90%, and was stable when kept at 10 degrees C for 72 h, at -20 degrees C until 12 weeks, and after three freeze-thaw cycles. This is the first report on determination of glabridin in body fluids by the selective, sensitive, and reproducible method.  相似文献   

8.
A validated, quantitative LC-APCI-MS/MS method for methadone, EDDP and EMDP in 200-microL plasma is presented. Specimen preparation was limited to protein precipitation and centrifugation. Chromatographic separation was achieved on a Synergi Hydro-RP 80A (50 mm x 2.0 m, 4 microm) column with gradient elution. The assay was linear from 1 to 500 ng/mL, with intra- and inter-assay accuracy >or=87.5% and intra- and inter-assay precision <13.4% R.S.D. and recovery >or=87.5% for all analytes at 40 ng/mL. This analytical method is suitable for the accurate and precise determination of methadone and metabolites in human plasma specimens.  相似文献   

9.
Thirty human EDTA plasma samples from male and female subjects ranging in age from 24 to 74 years were collected on ice, processed ice cold and stored frozen at ?80 °C, in liquid nitrogen (LN2), or freeze dried and stored at room temperature in a desiccator (FDRT) or freeze dried and stored at ?20 °C for 1 year (FD-20). In a separate experiment, EDTA plasma samples were collected onto ice, processed ice cold and maintained on ice ± protease inhibitors versus incubated at room temperature for up to 96 h. Random and independent sampling by liquid chromatography and tandem mass spectrometry (LC–ESI–MS/MS), as correlated by the MASCOT, OMSSA, X!TANDEM and SEQUEST algorithms, showed that tryptic peptides from complement component 4B (C4B) were rapidly released in plasma at room temperature. Random sampling by LC–ESI–MS/MS showed that peptides from C4B were undetectable on ice, but peptides were cleaved from the mature C4B protein including NGFKSHALQLNNR within as little as 1 h at room temperature. The frequency and intensity of precursors within ± 3 m/z of the C4B peptide NGFKSHALQLNNR was confirmed by automated targeted analysis where the precursors from MS/MS spectra that correlated to the target sequence were analyzed in SQL/R. The C4B preproprotein was processed at the N terminus to release the mature chain that was cleaved on the carboxyl side of the isoprene C2 domain within a polar C terminal sequence of the mature C4B protein, to reveal the thioester reaction site, consistent with LC–ESI–MS/MS and Western blot. Random sampling showed that proteolytic peptides from complement component C4B were rarely observed with long term storage at ? 80 °C in a freezer or in liquid nitrogen (LN2), freeze drying with storage at ? 20 °C (FD-20 °C) or freeze drying and storage at room temperature (FDRT). Plasma samples maintained at room temperature (RT) showed at least 10-fold to 100-fold greater frequency of peptide correlation to C4B and measured peptide intensity compared to samples on ice for up to 72 h or stored at ? 80 °C, LN2, FDRT or FD-20 °C for up to a year.  相似文献   

10.
A highly sensitive and ultra-fast high performance liquid chromatography- tandem mass spectrometry (LC–MS/MS) assay is developed and validated for the quantification of Lenalidomide in human plasma. Lenalidomide is extracted from human plasma by Liquid- Liquid Extraction by Ethyl Acetate and analyzed using a reversed phase isocratic elution on a XTerra RP18, (4.6 × 50 mM, 5 µm) column. A 0.1% Formic acid: Methanol (10:90% v/v), is used as mobile phase and detection was performed by Triple quadrupole mass spectrometry LC-MS/MS using electrospray ionization in positive mode. Fluconazole is used as the internal standard. The lower limit of quantification is 9.999 ng/mL for Lenalidomide. The calibration curves are consistently accurate and precise over the concentration range of 9.999 to 1010.011 ng/mL in plasma for Lenalidomide. This novel LC–MS/MS method competes with all the regulatory requirements and shows satisfactory accuracy and precision and is sufficiently sensitive for the performance of pharmacokinetic and bioequivalence studies in humans.  相似文献   

11.
Prostanoids are bioactive substances that contribute to various biological and pathological processes. To evaluate both extracellular and intracellular levels of prostanoids at the same time, we developed methods for quantification of extracellular and intracellular levels of prostanoids, including prostaglandin E(2) (PGE(2)), PGD(2), PGF(2α), 6-keto PGF(1α), and TXB(2), in cultured cells using liquid chromatography/tandem mass spectrometry (LC/MS/MS), and we validated the LC/MS/MS methods. A solid-phase extraction cartridge was used for extraction of prostanoids. The prostanoids were separated by a C(18) column with an isocratic flow of acetonitrile/water/acetic acid (40:60:0.1, v/v/v). Calibration curves of extracellular measurement for the prostanoids were linear in the range from 0.1 to 100 ng/mL (r(2)>0.999), and those of intracellular measurement were linear in the range from 0.05 to 50 ng (r(2)>0.999). Validation assessment showed that both methods of extracellular and intracellular measurements were highly reliable with good accuracy and precision. We also applied the methods to human airway epithelial Calu-3 cells and human lung adenocarcinoma epithelial A549 cells.  相似文献   

12.
BMS-068645 is a selective adenosine 2A agonist that contains a methyl ester group which undergoes esterase hydrolysis to its acid metabolite. To permit accurate determinations of circulating BMS-068645 and its acid metabolite, blood samples must be rapidly stabilized at the time of collection. A sensitive, rapid and specific liquid chromatography-tandem mass spectrometry (LC/MS/MS) method for the simultaneous quantitation of BMS-068645 and its acid metabolite in human plasma has been developed and validated using diisopropyl fluorophosphate (DFP) as the esterase inhibitor to prevent BMS-068645 from converting to its acid metabolite. The D(5)-stable isotope labeled analogs of BMS-068645 and its metabolite were used as the internal standards (IS). Analytes and IS in plasma containing 20 mM DFP were acidified and extracted into methyl tert-butyl ether. The liquid-liquid extraction effectively eliminated the strong matrix effect caused by the esterase inhibitor. The chromatographic separation was achieved on a Waters Atlantis C18 column with a run time of 4 min. Detection was performed on a Sciex API 4000 with positive ion electrospray mode (ESI/MS/MS), monitoring the ion transitions m/z 487>314 and 473>300 for BMS-068645 and its acid metabolite, respectively. The method was validated over the range from 0.020 to 10.0 ng/mL for BMS-068645 and 0.050 to 10.0 ng/mL for its acid metabolite. Inter- and intra-run precision for the quality control samples during validation were less than 8.7% and 4.0%, respectively, for the two analytes. The assay accuracy was within +/-5.4% of the nominal values. The esterase inhibitor effectively stabilized BMS-068645 during blood collection and storage. Blood collection tubes containing DFP were easily prepared and used at the clinical sites and could be stored at -30 degrees C for 3 months. This method demonstrated adequate sensitivity, specificity, accuracy, precision, stability and ruggedness to support the analysis of human plasma samples in pharmacokinetic studies.  相似文献   

13.
In the present work, a high-throughput LC/MS/MS method using a Chromolith RP-18 (50 mm x 4.6 mm) monolithic column was developed and partially validated for the determination of bupropion (BUP), an anti-depressant drug, and its metabolites, hydroxybupropion and threo-hydrobupropion (TB), in human, mouse, and rat plasma. A modern integrated liquid chromatograph and an LC/MS/MS system with a TurboIonSpray (TIS) interface were used for the positive electrospray selected reaction monitoring (SRM) LC/MS analyses. Spiked control plasma calibration standards and quality control (QC) samples were extracted by semi-automated 96-well liquid-liquid extraction (LLE) using ethyl acetate. A mobile phase consisting of 8mM ammonium acetate-acetonitrile (55:45, v/v) delivered isocratically at 5 ml/min, and split post-column to 2 ml/min directed to the TIS, provided the optimum conditions for the chromatographic separation of bupropion and its metabolites within 23s. The isotope-labeled D(6)-bupropion and D(6)-hydroxybupropion were used as internal standards. The method was linear over a concentration range of 0.25-200 ng/ml (bupropion and threo-hydrobupropion), and 1.25-1000 ng/ml (hydroxybupropion). The intra- and inter-day assay accuracy and precision were within 15% for all analytes in each of the biological matrices. The monolithic column performance as a function of column backpressure, peak asymmetry, and retention time reproducibility was adequately maintained over 864 extracted plasma injections.  相似文献   

14.
An HPLC method was developed and validated for the determination of mifepristone in human plasma. C(18) solid-phase extraction cartridges were used to extract plasma samples. Separation was by C(18) column; mobile phase, methanol-acetonitrile-water (50:25:25, v/v/v); flow rate, 0.8 ml/min; UV detection at 302 nm. The calibration curve was linear in the concentration range of 10 ng/ml to 20 microg/ml (r=0.9991). Within- and between-day variability were acceptable. The limit of detection for the assay was 6 ng/ml. Plasma samples were stable for at least 7 days in the state of plasma or residue treated at -20 degrees C. The method was simple, sensitive and accurate, and allowed to determine ng mifepristone in human plasma. It could be applied to assess the plasma level of mifepristone in women receiving low oral doses of mifepristone.  相似文献   

15.
A simple, high throughput, direct-injection high-performance liquid chromatography tandem mass spectrometry method (LC/MS/MS) has been developed and validated for the quantitation of pioglitazone in human serum. After mixing the internal standard with a sample, a 10 microl portion of the mixture was directly injected into a high-flow LC/MS/MS system, which included an extraction column, an analytical column and a six-port switching valve. The on-line extraction was achieved on an Oasis HLB column (1 mm x 50 mm, 30 microm) with a 100% aqueous loading mobile phase containing 5 mM ammonium acetate (pH 4.0) at a flow rate of 4 ml/min. The extracted analyte was eluted by a mobile phase which contained 5 mM ammonium acetate and acetonitrile. The analytical column was a Luna C18 column (4.6 mm x 50 mm, 5 microm). Detection was achieved by positive ion electrospray tandem mass spectrometry. The lower limit of quantitation of the method was 9 ng/ml. The standard curve, which ranged from 9 to 1350 ng/ml, was fitted by a weighted (1/x2) quadratic regression model. The validation results demonstrated that this method had satisfactory precision and accuracy across the calibration range. There was no evidence of instability of the analyte in human serum following three freeze-thaw cycles, and samples could be stored for at least 2 weeks at -30 degrees C. This method was used to analyze pioglitazone concentrations in human serum samples from a bioequivalence study of a blinded Actos formulation (encapsulated 15 mg tablet) and an Actos 15 mg tablet. The blinded formulation was shown to be bioequivalent to an Actos 15 mg tablet.  相似文献   

16.
A new simple method was developed for the quantitative determination of the docetaxel (Taxotere) vehicle, polysorbate 80 (Tween 80), in human plasma. Calibration curves were constructed in the range of 1-100 microg/ml, using paclitaxel (0.01 mM) as internal standard, and were analyzed using a power fit with equal weighting. Sample pretreatment involved a one-step extraction with acetonitrile-n-butyl chloride (1:4, v/v). The analytes were separated on a Waters X-Terra MS column (50x2.1 mm I.D.) packed with 3.5-microm ODS material, and eluted with methanol-water (9:1, v/v) containing 0.1% formic acid. The column effluent was monitored by tandem mass spectrometry with electrospray ionization. The overall extraction efficiency was 50-60%, with values for precision and accuracy of < or =16% and <15% relative error, respectively. Our current method is approximately 60-100-fold more sensitive than previous assays, and will be used to define Tween 80 disposition in patients receiving Taxotere.  相似文献   

17.

Background

Normal human EDTA plasma samples were collected on ice, processed ice cold, and stored in a freezer at – 80 °C prior to experiments. Plasma test samples from the – 80 °C freezer were thawed on ice or intentionally warmed to room temperature.

Methods

Protein content was measured by CBBR binding and the release of alcohol soluble amines by the Cd ninhydrin assay. Plasma peptides released over time were collected over C18 for random and independent sampling by liquid chromatography micro electrospray ionization and tandem mass spectrometry (LC–ESI–MS/MS) and correlated with X!TANDEM.

Results

Fully tryptic peptides by X!TANDEM returned a similar set of proteins, but was more computationally efficient, than “no enzyme” correlations. Plasma samples maintained on ice, or ice with a cocktail of protease inhibitors, showed lower background amounts of plasma peptides compared to samples incubated at room temperature. Regression analysis indicated that warming plasma to room temperature, versus ice cold, resulted in a ~ twofold increase in the frequency of peptide identification over hours–days of incubation at room temperature. The type I error rate of the protein identification from the X!TANDEM algorithm combined was estimated to be low compared to a null model of computer generated random MS/MS spectra.

Conclusion

The peptides of human plasma were identified and quantified with low error rates by random and independent sampling that revealed 1000s of peptides from hundreds of human plasma proteins from endogenous tryptic peptides.
  相似文献   

18.
A rapid, sensitive and specific method was developed and validated using liquid chromatography-tandem mass spectrometry (LC/MS/MS) for determination of gefitinib in human plasma and mouse plasma and tissue. Sample preparation involved a single protein precipitation step by the addition of 0.1 mL of plasma or a 200 mg/mL tissue homogenate diluted 1/10 in human plasma with 0.3 mL acetonitrile. Separation of the compounds of interest, including the internal standard (d8)-gefitinib, was achieved on a Waters X-Terra C18 (50 mm x 2.1 mm i.d., 3.5 microm) analytical column using a mobile phase consisting of acetonitrile-water (70:30, v/v) containing 0.1% formic acid and isocratic flow at 0.15 mL/min for 3 min. The analytes were monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the range of 1-1000 ng/mL for the human plasma samples and 5-1000 ng/mL for mouse plasma and tissue samples with values for the coefficient of determination of > 0.99. The values for both within- and between-day precision and accuracy were well within the generally accepted criteria for analytical methods (< 15%). This method was subsequently used to measure concentrations of gefitinib in mice following administration of a single dose of 150 mg/kg intraperitoneally and in cancer patients receiving an oral daily dose of 250 mg.  相似文献   

19.
Analytical methods for the determination of ximelagatran, an oral direct thrombin inhibitor, its active metabolite melagatran, and intermediate metabolites, melagatran hydroxyamidine and melagatran ethyl ester, in biological samples by liquid chromatography (LC) positive electrospray ionization mass spectrometry (MS) using selected reaction monitoring are described. Isolation from human plasma was achieved by solid-phase extraction on octylsilica. Analytes and isotope-labelled internal standards were separated by LC utilising a C(18) analytical column and a mobile phase comprising acetonitrile-4 mmol/l ammonium acetate (35:65, v/v) containing 0.1% formic acid, at a flow-rate of 0.75 ml/min. Absolute recovery was approximately 80% for ximelagatran, approximately 60% for melagatran ethyl ester and >90% for melagatran and melagatran hydroxyamidine. Limit of quantification was 10 nmol/l, with a relative standard deviation <20% for each analyte and <5% above 100 nmol/l. Procedures for determination of these analytes in human urine and breast milk, plus whole blood from rat and mouse are also described.  相似文献   

20.
A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC/MS/MS) method for the determination of tiropramide in human plasma was developed. Tiropramide and internal standard, cisapride were extracted from human plasma by liquid-liquid extraction and analyzed on a Luna C8 column with the mobile phase of acetonitrile-ammonium formate (10mM, pH 4.5) (50:50, v/v). The analytes was detected using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. The standard curve was linear (r=0.998) over the concentration range of 2.0-200 ng/ml. The intra- and inter-assay coefficients of variation ranged from 2.8 to 7.8 and 6.7 to 8.9%, respectively. The recoveries of tiropramide ranged from 50.2 to 53.1%, with that of cisapride (internal standard) being 60.9+/-5.3%. The lower limit of quantification for tiropramide was 2.0 ng/ml using 100 microl plasma sample. This method was applied to the pharmacokinetic study of tiropramide in human.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号