Olanzapine is a commonly used atypical antipsychotic medication for which therapeutic drug monitoring has been proposed as clinically useful. A sensitive method was developed for the determination of olanzapine concentrations in plasma and urine by high-performance liquid chromatography with low-wavelength ultraviolet absorption detection (214 nm). A single-step liquid–liquid extraction procedure using heptane-iso-amyl alcohol (97.5:2.5 v/v) was employed to recover olanzapine and the internal standard (a 2-ethylated olanzapine derivative) from the biological matrices which were adjusted to pH 10 with 1 M carbonate buffer. Detector response was linear from 1–5000 ng (r2>0.98). The limit of detection of the assay (signal:noise=3:1) and the lower limit of quantitation were 0.75 ng and 1 ng/ml of olanzapine, respectively. Interday variation for olanzapine 50 ng/ml in plasma and urine was 5.2% and 7.1% (n=5), respectively, and 9.5 and 12.3% at 1 ng/ml (n=5). Intraday variation for olanzapine 50 ng/ml in plasma and urine was 8.1% and 9.6% (n=15), respectively, and 14.2 and 17.1% at 1 ng/ml (n=15). The recoveries of olanzapine (50 ng/ml) and the internal standard were 83±6 and 92±6% in plasma, respectively, and 79±7 and 89±7% in urine, respectively. Accuracy was 96% and 93% at 50 and 1 ng/ml, respectively. The applicability of the assay was demonstrated by determining plasma concentrations of olanzapine in a healthy male volunteer for 48 h following a single oral dose of 5 mg olanzapine. This method is suitable for studying olanzapine disposition in single or multiple-dose pharmacokinetic studies.  相似文献   

2.
A rapid and sensitive method for extracting temazepam from human serum and urine is presented. Free temazepam is extracted from plasma and urine samples using n-butyl chloride with nitrazepam as the internal standard. Temazepam glucuronide is analyzed as free temazepam after incubating extracts with β-glucuronidase. Separation is achieved using a C8 reversed-phase column with a methanol—water—phosphate buffer mobile phase. An ultraviolet detector operated at 230 nm is used and a linear response is observed from 20 ng/ml to 10 μg/ml. The limit of detection is 15.5 ng/ml and the limit of quantitation is 46.5 ng/ml. Coefficients of variation are less than 10% for concentrations greater than 50 ng/ml. Application of the methodology is demonstrated in a pharmacokinetic study using eight healthy male subjects.  相似文献   

3.
Karenitecin is a novel, highly lipophilic camptothecin derivative with potent anticancer potential. We have developed a sensitive high-performance liquid chromatographic method for the determination of karenitecin concentration in human plasma and urine. Karenitecin was isolated from human plasma and urine using solid-phase extraction. Separation was achieved by gradient elution, using a water and acetonitrile mobile phase, on an ODS analytical column. Karenitecin was detected using fluorescence detection at excitation and emission wavelengths of 370 and 490 nm, respectively. Retention time for karenitecin was 16.2±0.5 min and 8.0±0.2 min for camptothecin, the internal standard. The karenitecin peak was baseline resolved, with the nearest peak at 3.1 min distance. Using normal volunteer plasma and urine from multiple individuals, as well as samples from the 50 patients analyzed to date, no interfering peaks were detected. Inter- and intra-day coefficients of variance were <4.4 and 7.1% for plasma and <4.9 and 11.6% for urine. Assay precision, based on an extracted karenitecin standard plasma sample of 2.5 ng/ml, was +4.46% with a mean accuracy of 92.4%. For extracted karenitecin standard urine samples of 2.5 ng/ml assay precision was +2.35% with a mean accuracy of 99.5%. The mean recovery of karenitecin, at plasma concentrations of 1.0 and 50 ng/ml, was 81.9 and 87.8% respectively. In urine, at concentrations of 1.5 and 50 ng/ml, the mean recoveries were 90.3 and 78.4% respectively. The lower limit of detection (LLD) for karenitecin was 0.5 ng/ml in plasma and 1.0 ng/ml in urine. The lower limit of quantification (LLQ) for karenitecin was 1 ng/ml and 1.5 ng/ml for plasma and urine, respectively. Stability studies indicate that when frozen at −70°C, karenitecin is stable in human plasma for up to 3 months and in human urine for up to 1 month. This method is useful for the quantification of karenitecin in plasma and urine samples for clinical pharmacology studies in patients receiving this agent in clinical trials.  相似文献   

4.
An HPLC system using solid-phase extraction and HPLC with UV detection has been validated in order to determine tramadol and o-desmethyltramadol (M1) concentrations in human plasma. The method developed was selective and linear for concentrations ranging from 50 to 3500 ng/ml (tramadol) and 50 to 500 ng/ml (M1) with mean recoveries of 94.36±12.53% and 93.52±7.88%, respectively. Limit of quantitation (LOQ) was 50 ng/ml. For tramadol, the intra-day accuracy ranged from 95.48 to 114.64% and the inter-day accuracy, 97.21 to 103.24%. Good precision (0.51 and 18.32% for intra- and inter-day, respectively) was obtained at LOQ. The system has been applied to determine tramadol concentrations in human plasma samples for a pharmacokinetic study.  相似文献   

5.
GS4071 is a potent inhibitor of influenza neuraminidase. A precolumn fluorescence derivatization HPLC method is described for the analysis of GS4071 in rat plasma. Plasma samples were subjected to solid-phase extraction on C18 extraction columns. After extraction, GS4071 was derivatized with naphthalenedialdehyde in the presence of potassium cyanide to produce highly fluorescent cyano[f]benzoisoindole derivatives. Derivatized samples were stable for >24 h at 4°C. The samples were analyzed by an isocratic HPLC method using fluorescence detection at 420 nm excitation and 470 nm emission wavelength. The method was validated and applied to the analysis of plasma samples from pre-clinical pharmacokinetic studies in rats. The limit of detection for GS4071 was 20 ng/ml. For five replicate samples at 50, 400, and 1000 ng/ml, the within-day precision values were 16.9, 9.4 and 4.5%, respectively, and the between-day precision values were 16.9, 7.9, and 2.1%, respectively. The method was linear from 25 to 1600 ng/ml and the total recovery was >68% over this concentration range.  相似文献   

6.
A sensitive and selective high-performance liquid chromatographic (HPLC) method was developed for the determination of pramipexole in human plasma and urine. Plasma/urine is made alkaline before pramipexole and BHT-920 (internal standard) are extracted by ethyl ether and back-extracted with a solution that contains heptanesulfonic acid. Separation is achieved by ion-pair chromatography on a Zorbax Rx C8 column with electrochemical detection at 0.6 V for plasma and ultraviolet detection at 286 nm for urine. The retention times of pramipexole and internal standard are approximately 14.4 and 10.7 min, respectively. The assay is linear in concentration ranges of 50 to 15 000 pg/ml (plasma) and 10 to 10 000 ng/ml (urine). The correlation coefficients are greater than 0.9992 for all curves. For the plasma method, the analysis of pooled quality controls (300, 3000, and 10 000 pg/ml) demonstrates excellent precision with relative standard deviations (R.S.D.) (n=18) of 1.1%, 2.3%, and 6.8%, respectively. For the urine method, quality control pools prepared at 30, 300, and 3000 ng/ml had R.S.D. values (n=18) of 2.9%, 1.7%, and 3.0%, respectively. The plasma and urine controls were stable for more than nine and three months, respectively. The mean recoveries for pramipexole and internal standard from plasma were 97.7% and 98.2%, respectively. The mean recoveries for pramipexole and internal standard from urine were 89.8% and 95.1%, respectively. The method is accurate with all intra-day (n=6) and overall (n=18) mean values for the quality control samples being less than 6.4 and 5.8% from theoretical for plasma and urine, respectively.  相似文献   

7.
A high-performance liquid chromatographic method was developed for the determination of a new non-narcotic analgesic, DA-5018 (I), in rat plasma, urine and bile samples, using propranolol for plasma samples and protriptyline for urine and bile samples as internal standards. The method involved extraction followed by injection of 100 μl of the aqueous layer onto a C18 reversed-phase column. The mobile phases were 5 mM methanesulfonic acid with 10 mM NaH2PO4 (pH 2.5)-acetonitrile, 70:30 (v/v) for plasma samples and 75:25 (v/v) for urine and bile samples. The flow-rates were 1.0 ml/min for plasma samples and 1.2 ml/min for urine and bile samples. The column effluent was monitored by a fluorescence detector with an excitation wavelength of 270 nm and an emission wavelength of 330 nm. The retention time for I was 4.8 min in plasma samples and 10.0 min in urine and bile samples. The detection limits for I in rat plasma, urine and bile were 20, 100 and 100 ng/ml, respectively. There was no interference from endogenous substances.  相似文献   

8.
A rapid and simple high-performance liquid chromatographic method with amperometric detection has been developed for the quantitation of cilazapril and its active metabolite and degradation product cilazaprilat in urine and tablets. The chromatographic system consisted of a μBondapak C18 column, using a mixture of methanol–5 mM phosphoric acid (50:50, v/v) as mobile phase, which was pumped at a flow-rate of 1.0 ml/min. The column was kept at a constant temperature of (40±0.2)°C. Detection was performed using a glassy carbon electrode at a potential of 1350 mV. Sample preparation for urine consisted of a solid-phase extraction using C8 cartridges. This procedure allowed recoveries greater than 85% for both compounds. The method proved to be accurate, precise and sensitive enough to be applied to pharmacokinetic studies and it has been applied to urine samples obtained from four hypertensive patients (detection limit of 50 ng/ml for cilazapril and 40 ng/ml for cilazaprilat in urine). Results were in good agreement with pharmacokinetic data.  相似文献   

9.
Sensitive and specific high-performance liquid chromatographic methods with fluorescence detection are described for the determination of the metabolites of mox sylyte (4-(2-dimethylaminoethoxy)-5-isopropyl-2-methylphenyl acetate) in human plasma and urine. Deacetylmoxisylyte glucuroconjugate (DAM-G) was hydrolysed enzymatically using β-glucuronidase and quantified as the difference between the DAM concentrations determined after and before hydrolysis. The two sulphate derivatives (deacetylmoxisy;yte sulphoconjugate, DAM-S and monomethyldeacetylmoxisylyte sulphoconjugate, MDAM-S), were analysed without prior hydrolysis. Their extraction from plasma and urine, as well as that of DAM from plasma, involved the use of C18 cartridges adapted on a Benchmate workstation. DAM in urine was quantified after liquid-liquid extraction. The two methods were validated for specificity, linearity, intra- and inter-day precision and accuracy. Precision was generally ≤15% and accuracy ≤12%. In plasma, the limits of quantification were 2.5 ng/ml for DAM and 2.8 ng/ml for the two sulphates; in urine, they were 40 ng/ml for DAM and 200 ng/ml for the sulphates. These methods were used for pharmacokinetic studies in healthy subjects.  相似文献   

10.
A method for the determination of L-756 423, a novel HIV protease inhibitor, in human plasma and urine is described. Plasma and urine samples were extracted using 3M Empore extraction disk cartridges in the C18 and MPC (mixed-phase cation-exchange) formats, respectively. The extract was analyzed using HPLC with fluorescence detection (ex 248 nm, em 300 nm), and included a column switching procedure to reduce run-time. The assay was linear in the concentration range 5 to 1000 ng/ml when 1-ml aliquots of plasma and urine were extracted. Recoveries of L-756 423 were greater than 84% over the calibration curve range using the described sample preparation procedures. Intra-day precision and accuracy for this assay was less than 9% RSD and within 7%, respectively. Inter-day variabilities for the plasma (n=17) and urine (n=10) were less than 5% and 3% for low (15 ng/ml) and high (750 ng/ml) quality control samples. Bovine serum albumin (0.5%) was used as an additive to urine to prevent precipitation of L-756 423 during the storage of clinical samples. The assay was used in support of human clinical trials.  相似文献   

11.
An efficient method for the determination of atenolol in human plasma and urine was developed and validated. α-Hydroxymetoprolol, a compound with a similar polarity to atenolol, was used as the internal standard in the present high-performance liquid chromatographic analysis with fluorescence detection. The assay was validated for the concentration range of 2 to 5000 ng/ml in plasma and 1 to 20 μg.ml in urine. For both plasma and urine, the lower limit of detection was 1 ng/ml. The intra-day and inter-day variabilities for plasma samples at 40 and 900 ng/ml, and urine samples at 9.5 μg/ml were <3% (n=5).  相似文献   

12.
We have established a highly sensitive high-performance liquid chromatographic method for the determination of an anticancer drug, UCN-01, in human plasma or urine. Using a fluorescence detector set at an excitation wavelength of 310 nm and emission monitored at 410 nm, there was a good linearity for UCN-01 in human plasma (r=0.999) or urine (r=0.999) at concentrations ranging from 0.2 to 100 ng/ml or 1 to 400 ng/ml, respectively. For intra-day assay, in plasma samples, the precision and accuracy were 1.8% to 5.6% and −10.0% to 5.2%, respectively. For inter-day assay, the precision and accuracy were 2.0% to 18.2% and 2.4% to 10.0%, respectively. In urine samples, the intra- and inter-day precision and accuracy were within 3.9% and ±2.7%, respectively. The lower limit of quantification (LLOQ) was set at 0.2 ng/ml in plasma and 1 ng/ml in urine. UCN-01 in plasma samples was stable up to two weeks at −80°C and also up to four weeks in urine samples. This method could be very useful for studying the human pharmacokinetics of UCN-01.  相似文献   

13.
A liquid chromatographic method with photometric detection for the determination of cilazapril and its active metabolite and degradation product cilazaprilat in urine and pharmaceuticals has been developed. The chromatographic method consisted of a μBondapak C18 column maintained at 30±0.2°C, using a mixture of methanol-10 mM phosphoric acid (50:50 v/v) as mobile phase at a flow-rate of 1.0 ml/min. Enalapril maleate was used as internal standard. The detection was performed at a wavelength of 206 nm. A study of the retention of cilazapril and cilazaprilat using solid–liquid extraction has been carried out in order to optimise the clean-up procedure for urine samples, which consisted of a solid–liquid extraction using C8 cartridges. Recoveries greater than 85% are obtained for both compounds. The method was sensitive, precise and accurate enough to be applied to the determination of urine samples obtained from three hypertensive patients up to 24 h after intake of a therapeutic dose (detection limit of 70 ng/ml for cilazapril and cilazaprilat in urine). A comparison of the method developed using photometric and amperometric detection has been carried out.  相似文献   

14.
An analytical method for the detection in biological samples of the novel tricyclic compound adosupine (10-acetoamido-5-methyl-5,6-dihydro-11H-dibenzo[b,e]azepin-6,11-dione), which is capable of influencing various forms of urinary bladder hyperreflexia has been developed using high-performance liquid chromatography with UV detection. Liquid—liquid extraction was used to isolate the parent compound, three metabolites and an analogue (added as internal standard) from plasma and brain of rat. Adosupine was well separated from its three metabolites with 0.01 M disodium hydrogenphosphate—acetonitrile—methanol—nonylamine (59.986:38:2:0.014) at pH 4.5 as mobile phase using a C18 reversed-phase column. The standard curves were linear in the range 50–5000 ng/ml (or ng/g) for adosupine and metabolites in both plasma and brain. The between- and within-assay variations for high and low concentrations of the parent compound and the three metabolites were 8.2–14%. In the range 50–5000 ng/ml (or ng/g) the accuracy of the method was satisfactory, with the relative error always lower than 10%. Analytical recoveries of added adosupine and the three metabolites were higher than 82%. The method has been applied successfully, to investigate the pharmacokinetics of the drug and its distribution in the central nervous system of rats.  相似文献   

15.
A sensitive, selective and reproducible reversed-phase HPLC method with ultraviolet detection was developed for the quantification of diazepam in small plasma samples from children with severe malaria. The method involves plasma deproteinization with acetonitrile, followed by liquid–liquid extraction with ethyl acetate–n-hexane. Diazepam was eluted at ambient temperatures from a reversed-phase C18 column with an acidic (pH 3.5) aqueous mobile phase (10 mM KH2PO4–acetonitrile, 69:31, v/v). Calibration curves in spiked plasma were linear from 10 to 200 ng (r2≥0.99). The limit of detection was 5.0 ng/ml, and relative recoveries at 25 and 180 ng were >87%. Intra- and inter-assay relative standard deviations were <15%. There was no interference from drugs commonly administered to children with severe malaria (phenobarbitone, phenytoin, chloroquine, quinine, sulfadoxine, pyrimethamine, halofantrine, cycloguanil, chlorcycloguanil, acetaminophen and salicylate). This method has been used for monitoring plasma diazepam concentrations in children with seizures associated with severe malaria.  相似文献   

16.
A highly sensitive and selective method for determining 8-oxoguanine in plasma and urine was developed by high-performance liquid chromatography with electrochemical detection. The compound was separated by gradient elution on a C18 reversed-phase column with a mobile phase of acetonitrile and 0.1 M sodium acetate, pH 5.2. 8-Hydroxy-2′-deoxyguanosine was used as internal standard. 8-Oxoguanine was detected electrochemically by setting the potential to +300 mV vs. Pd reference. The sensitivity of the assay was 22 ng/ml with a signal-to-noise ratio of 7:1. The within-day relative standard deviations for 8-oxoguanine quality control samples with concentrations of 3340, 1340 and 84 ng/ml were 3.6, 4.3 and 5.7% for plasma, and 4.1, 4.6 and 6.2% for urine, respectively. The day-to-day relative standard deviations for the same samples were 3.8, 6.8 and 7.1% for plasma, and 3.9, 7.0 and 7.9% for urine, respectively. The method is designed to study the pharmacokinetics and metabolic fate of O6-benzylguanine in a phase I clinical trial. Previously, O6-benzyl-8-oxoguanine was identified as the primary metabolite of O6-benzylguanine in humans. We now demonstrate that 8-oxoguanine is a further metabolite of O6-benzylguanine.  相似文献   

17.
A simple extraction procedure and a sensitive high-performance liquid chromatographic (HPLC) method are described for the determination of the photodynamic therapeutic agent 5, 10, 15, 20-tetra(m-hydroxyphenyl)chlorin (mTHPC) in plasma and tumour tissue. Reversed-phase high-performance liquid chromatography was performed on a C18 column (70×4.6 mm I.D.) with a mobile phase of 0.01 M potassium dihydrogenphosphate buffer, pH 2.5-acetonitrile (55:45, v/v) and a coulometric detection (+0.80 V). The mean recoveries of mTHPC in the concentration ranges (5–2000 and 10–1000 ng/ml) were 90 and 89% for plasma and tumour samples, respectively. The procedure for plasma and tissue preparation involved solvent precipitation using methanol combined with ammonia solution and dimethyl sulphoxide (4, 0.2, 0.1, v/v/v) and (2, 0.1, 0.1, v/v/v) for plasma and tissue, respectively. For mTHPC at concentrations ranging from 5 to 2000 ng/ml, the within-day relative standard deviations, based on triplicate determinations were less than 8% and the between-day relative standard deviations calculated by performing extraction procedure of plasma samples on three different days ranged from 3 to 18%. This highly sensitive method, 5 and 10 ng/ml for plasma and tissue respectively, was applied successfully to the determination of mTHPC in mouse tumours for pharmacokinetic studies.  相似文献   

18.
AG 331 is a novel thymidylate synthase inhibitor currently in Phase I clinical trial. To determine the pharmacokinetic parameters of AG 331 in human subjects, a suitable analytical method was developed using high-performance liquid chromatography. Serum and urine samples were prepared using both solid-phase extraction and solvent extraction. Either 4,4′-diaminodiphenyl sulfone or benz[cd]indole-2(1H)-one were used as internal standards for the method. A reversed-phase C18 analytical column completely resolved the drug and internal standard peaks from non-specific substances present in biological matrix. The method was validated for precision, accuracy, and reproducibility in serum and was linear over a concentration range of 50–2000 ng/ml, with a limit of detection of 20.0 ng/ml and a quantifiable limit of 50 ng/ml.  相似文献   

19.
A high-performance liquid chromatographic method for the measurement of bumetamide in plasma and urine is described. Following precipitation of proteins with acetonitrile, bumetanide was extracted from plasma or urine on a 1-ml bonded-phase C18 column and eluted with acetonitrile. Piretanide dissolved in methanol was used as the internal standard. A C18 Radial Pak column and fluorescence detection (excitation wavelength 228 nm; emission wavelength 418 nm) were used. The mobile phase consisted of methanol—water—glacial acetic acid (66:34:1, v/v) delivered isocratically at a flow-rate of 1.2 ml/min. The lower limit of detection for this method was 5 ng/ml using 0.2 ml of plasma or urine. Nafcillin, but not other semi-synthetic penicillins, was the only commonly used drug that interfered with this assay. No interference from endogenous compounds was detected. For plasma, the inter-assay coefficients of variation of the method were 7.6 and 4.4% for samples containing 10 and 250 ng/ml bumetanide, respectively. The inter-assay coefficients of variation for urine samples containing 10 and 2000 ng/ml were 8.1 and 5.7%, respectively. The calibration curve was linear over the range 5–2000 ng/ml.  相似文献   

20.
A rapid, sensitive and selective high-performance liquid chromatographic (HPLC) assay was developed for the determination of cibenzoline (Cipralan TM) in human plasma and urine. The assay involves the extraction of the compound into benzene from plasma or urine buffered to pH 11 and HPLC analysis of the residue dissolved in acetonitrile---phosphate buffer (0.015 mol/1, pH 6.0) (80:20). A 10-μ ion-exchange (sulfonate) column was used with acetonitrile—phosphate buffer (0.015 mol/1, pH 6.0) (80:20) as the mobile phase. UV detection at 214 nm was used for quantitation with the di-p-methyl analogue of cibenzoline as the internal standard.The recovery of cibenzoline in the assay ranged from 60 to 70% and was validated in human plasma and urine in the concentration range of 10–1000 ng/ml and 50–5000 ng/ml, respectively. A normal-phase HPLC assay was developed for the determination of the imidazole metabolite of cibenzoline. The assays were applied to the determination of plasma and urine concentrations of cibenzoline and trace amounts of its imidazole metabolite following oral administration of cibenzoline succinate to two human subjects.  相似文献   