首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
目的:探讨磁共振弥散加权成像(DWI)及表观扩散系数(ADC)值在鼻咽癌颅底放疗中的临床价值。方法:收集我院于2013年6月~2014年6月复查的40例鼻咽癌患者,分别于放疗前及放疗结束12个月以后对所有患者行常规核磁共振成像(MRI)及DWI检查,测量放疗前、后ADC值,根据影像学检查以及临床诊断结果分为复发组(n=5)及未复发组(n=35)。结果:复发组放疗前ADC值为(0.797±0.031)×10~(-3)mm~2/s,与未复发组放疗前ADC值(0.805±0.028)×10~(-3)mm~2/s比较,差异无统计学意义(P0.05)。复发组放疗结束12个月以后ADC值为(1.097±0.091)×10~(-3)mm~2/s,与未复发组放疗结束12个月以后ADC值(1.705±0.128)×10~(-3)mm~2/s比较,差异有统计学意义(P0.05)。结论:DWI作为一种新兴的磁共振成像技术,对于鼻咽癌颅底放疗疗效的评价具有重要价值,通过DWI对ADC值的测量,可有效的预测患者预后是否良好。  相似文献   

2.
The purpose of this study was to investigate the effect of image quality under various imaging parameters (60, 70, 80, 90, 100, 110, and 120 kV at 200 mA and 10 ms/63, 80, 100, 160, 200, 250, and 320 mA at 120 kV and 10 ms) and the diameter of the fiducial marker (0.25, 0.50, 0.75, and 1.10 mm) on the correlation modeling error for dynamic tumor tracking (DTT) in the Vero4DRT system. Each fiducial marker was inserted into the center of the 30 × 30 × 10 cm3 water-equivalent phantom. A programmable respiratory motion table was used to simulate breathing-induced organ motion, with an amplitude of ±20 mm and a breathing cycle of 4 s. The correlation modeling error was calculated from the absolute difference between the detected and predicted target positions in the cranio-caudal direction. The image contrast of the fiducial marker was enhanced with increasing kV and mA. Increasing the diameter of the fiducial marker also enhanced the image contrast. Correlation-modeling error does not depend on the image quality and fiducial marker diameter. A lower kV setting did not generate a 4D model due to poor image contrast. All fiducial marker diameters were identified as good candidates for DTT in the Vero4DRT system.  相似文献   

3.
When female mice were given a dose of 20 × 10 rad X-rays, the specific locus mutation rate among offspring conceived up to 7 weeks after the end of treatment was 1/39887 or 0.18·10−7/rad/locus, whereas when the same total dose of 200 rad was given in a single exposure the mutation rate was 9/34813 or 1.85·1010−7/rad/locus. The lower mutation rate after the 20 × 10 rad dose was obtained whether the total of 200 rad was given over a period of 5 days or 4 weeks, and if only young conceived in the first 20 days, rather than 7 weeks, were considered. It is suggested that each 10 rad fraction had the same small effect, and hence that these results confirm and extend Russell's previous finding that the dose-response relationship for specific locus mutations in females is curved.  相似文献   

4.
PurposeTo determine the surface dose of a water phantom using a semiconductor detector for diagnostic kilovoltage x-ray beams.MethodsAn AGMS-DM+ semiconductor detector was calibrated in terms of air kerma measured with an ionization chamber. Air kerma was measured for 20 x-ray beams with tube voltages of 50–140 kVp and a half-value layer (HVL) of 2.2–9.7 mm Al for given quality index (QI) values of 0.4, 0.5, and 0.6, and converted to the surface dose. Finally, the air kerma and HVL measured by the AGMS-DM+ detector were expressed as a ratio of the surface dose for 10 × 10 and 20 × 20 cm2 fields. The ratio of both was represented as a function of HVL for the given QI values and verified by comparing it with that calculated using the Monte Carlo method.ResultsThe air kerma calibration factor, CF, for the AGMS-DM+ detector ranged from 0.986 to 1.016 (0.9% in k = 1). The CF values were almost independent of the x-ray fluence spectra for the given QI values. The ratio of the surface dose to the air kerma determined by the PTW 30,013 chamber and the AGMS-DM+ detector was less than 1.8% for the values calculated using the Monte Carlo method, and showed a good correlation with the HVL for the given QI values.ConclusionIt is possible to determine the surface dose of a water phantom from the air kerma and HVL measured by a semiconductor detector for given QI values.  相似文献   

5.
Nowadays MOSFET dosimeters are widely used for dose verification in radiotherapy procedures. Although their sensitive area satisfies size requirements for small field dosimetry, their use in radiosurgery has rarely been reported. The aim of this study is to propose and optimize a calibration method to perform surface measurements in 6 MV shaped-beam radiosurgery for field sizes down to 18 × 18 mm2. The effect of different parameters such as recovery time between 2 readings, batch uniformity and build-up cap attenuation was studied. Batch uniformity was found to be within 2% and isocenter dose attenuation due to the build-up cap over the MOSFET was near 2% irrespective of field size. Two sets of sensitivity coefficients (SC) were determined for TN-502RD MOSFET dosimeters using experimental and calculated calibration; the latter being developed using an inverse square law model. Validation measurements were performed on a realistic head phantom in irregular fields. MOSFET dose values obtained by applying either measured or calculated SC were compared. For calibration, optimal results were obtained for an inter-measurement time lapse of 5 min. We also found that fitting the SC values with the inverse square law reduced the number of measurements required for calibration. The study demonstrated that combining inverse square law and Sterling–Worthley formula resulted in an underestimation of up to 4% of the dose measured by MOSFETs for complex beam geometries. With the inverse square law, it is possible to reduce the number of measurements required for calibration for multiple field–SSD combinations. Our results suggested that MOSFETs are suitable sensors for dosimetry when used at the surface in shaped-beam radiosurgery down to 18 × 18 mm2.  相似文献   

6.
A successful nerve regeneration process was achieved with nerve repair tubes made up of 1-ethyl-3(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC) cross-linked carboxymethyl chitosan (CM-chitosan) with improved biodegradability. Chitosan has a very slow degradation rate, while the EDC cross-linked CM-chitosan tubes degraded to 30% of original weight during 8 weeks of incubation in lysozyme solution. In vitro cell culture indicated that the CM-chitosan films presented no cytotoxicity to Schwann cells. From in vivo studies using a 10 mm rat sciatic nerve defect model investigated by histomorphometry analysis, the average diameter of the fibers and the average thickness of myelin sheath in the CM-chitosan tubes were 3.7 ± 0.33 and 0.33 ± 0.04 μm, respectively, which demonstrated equivalence to nerve autografts (the current “gold” standard); furthermore, the average fiber density in the CM-chitosan tubes was 20.5 × 103/mm2, which was similar to that of autografts (21 × 103/mm2) and significantly higher than that of common chitosan tubes (15.3 × 103/mm2).  相似文献   

7.
The effects of weak magnetic fields of extremely low frequency (ELF) on E. coli K12 AB1157 cells were studied by the method of anomalous viscosity time dependencies (AVTD). E. coli cells at different densities within a range of 5 × 105–109 cell/ml were exposed to ELF (sinusoidal, 30 μT peak, 15 min) at a frequency of 9 Hz. A transient effect with maximum 40–120 min after exposure was observed. Kinetics of the per-cell-normalised ELF effects fitted well to a Gaussian distribution for all densities during exposure. A maximum value of these kinetics and a time for this maximum were strongly dependent on the cell density during exposure. These data suggest a cell-to-cell interaction during response to ELF. Both dependencies had three regions close to a plateau within the ranges of 3 × 105 − 2 × 107 cell/ml, 4 × 107 − 2 × 108 cell/ml and 4 × 108–109 cell/ml and two rather sharp transitions between these plateaus. The effect reached a maximum value at a density of 4 × 108 cell/ml. Practically no effect was observed at the lowest density of 3 × 105 cell/ml. The data suggested that the ELF effect was mainly caused by a secondary rather than a primary reaction. The filtrates from exposed cells neither induced significant AVTD changes in unexposed cells nor increased the ELF effect when were added to cells before exposure. The data did not provide evidence for significant contribution of stable chemical messengers, but some unstable compounds such as radicals could be involved in the mechanism of cell-to-cell interaction during response to ELF. The results obtained were also in accordance with a model based on an re-emission of secondary photons during resonance fluorescence. Bioelectromagnetics 19:300–309, 1998. © 1998 Wiley-Liss, Inc.  相似文献   

8.
The objective was to carry out cytotoxicity assays in Vero cells and cytokines analyses in Balb/c mice as safety assessments to evaluate the probiotic mixture (M) Saccharomyces cerevisiae RC016 (Sc) and Lactobacillus rhamnosus RC007 (Lr) for use as feed additive. Vero cells (104 cells per well) were exposed to Sc (2·08 × 107, 2·08 × 106; 2·08 × 105 cells per ml), Lr (8·33 × 107; 8·33 × 106; 8·33 × 105 cells per ml) and their M (1 : 1). Sc concentrations did not affect the Vero cells viability; in contrast, they were lower when exposed to Lr (P ˂ 0·0001). Vero cells showed increasing viability with M decreasing concentrations (91% viability with M2). Control BALB/c mice received only phosphate buffer saline and the others received the M. The IL-10, IL-6 and TNFα concentrations from intestinal fluid were analysed and no significant differences were observed among treatments. The same occurred with the ratio between IL-10/TNF-α. Beneficial effects of probiotics are associated with the regulation of the excessive inflammatory response; it is desirable they can modulate the cytokines production only under pathological conditions. Here, M administration to healthy mice did not induce negative side effects and expands the knowledge about beneficial effects of using probiotic microorganisms in mixture for feed additives development.  相似文献   

9.
Objective: To develop accurate and reliable equations from simple anthropometric parameters that would predict percentage of total body fat (%BF), total abdominal fat (TAF), subcutaneous abdominal adipose tissue (SCAT), and intra‐abdominal adipose tissue (IAAT) with a fair degree of accuracy. Methods and Procedures: Anthropometry, %BF by dual‐energy X‐ray absorptiometry (DXA) in 171 healthy subjects (95 men and 76 women) and TAF, IAAT, and SCAT by single slice magnetic resonance imaging (MRI) at L3–4 intervertebral level in 100 healthy subjects were measured. Mean age and BMI were 32.2 years and 22.9 kg/m2, respectively. Multiple regression analysis was used on the training data set (70%) to develop equations, by taking anthropometric and demographic variables as potential predictors. Predicted equations were applied on validation data set (30%). Results: Multiple regression analysis revealed the best equation for predicting %BF to be: %BF = 42.42 + 0.003 × age (years) + 7.04 × gender (M = 1, F = 2) + 0.42 × triceps skinfold (mm) + 0.29 × waist circumference (cm) ? 0.22 × weight (kg) ? 0.42 × height (cm) (R 2 = 86.4%). The most precise predictive equation for estimating IAAT was: IAAT (mm2) = ?238.7 + 16.9 × age (years) + 934.18 × gender (M = 1, F = 2) + 578.09 × BMI (kg/m2) ? 441.06 × hip circumference (cm) + 434.2 × waist circumference (cm) (R 2 = 52.1%). SCAT was best predicted by: SCAT (mm2) = ?49,376.4 ? 17.15 × age (years) + 1,016.5 × gender (M = 1, F = 2) +783.3 × BMI (kg/m2) + 466 × hip circumference (cm) (R 2 = 67.1). Discussion: We present predictive equations to quantify body fat and abdominal adipose tissue sub‐compartments in healthy Asian Indians. These equations could be used for clinical and research purposes.  相似文献   

10.
PurposeTo develop a four-dimensional (4D) dose calculation system for real-time tumor tracking (RTTT) irradiation by the Vero4DRT.MethodsFirst, a 6-MV photon beam delivered by the Vero4DRT was simulated using EGSnrc. A moving phantom position was directly measured by a laser displacement gauge. The pan and tilt angles, monitor units, and the indexing time indicating the phantom position were also extracted from a log file. Next, phase space data at any angle were created from both the log file and particle data under the dynamic multileaf collimator. Irradiation both with and without RTTT, with the phantom moving, were simulated using several treatment field sizes. Each was compared with the corresponding measurement using films. Finally, dose calculation for each computed tomography dataset of 10 respiratory phases with the X-ray head rotated was performed to simulate the RTTT irradiation (4D plan) for lung, liver, and pancreatic cancer patients. Dose-volume histograms of the 4D plan were compared with those calculated on the single reference respiratory phase without the gimbal rotation [three-dimensional (3D) plan].ResultsDifferences between the simulated and measured doses were less than 3% for RTTT irradiation in most areas, except the high-dose gradient. For clinical cases, the target coverage in 4D plans was almost identical to that of the 3D plans. However, the doses to organs at risk in the 4D plans varied at intermediate- and low-dose levels.ConclusionsOur proposed system has acceptable accuracy for RTTT irradiation in the Vero4DRT and is capable of simulating clinical RTTT plans.  相似文献   

11.
In a search for novel multifunctional anti-Alzheimer agents, a congeneric set of seventeen flavone-8-acrylamide derivatives (8a─q) were synthesized and evaluated for their cholinesterase inhibitory, antioxidant, neuroprotective and modulation of Aβ aggregation activities. The target compounds showed effective and selective inhibitory activity against the AChE over BuChE. In addition, the target compounds also showed moderate anti-oxidant activity and strong neuroprotective capacities, and accelerated dosage-dependently the Aβ aggregation. Also, we presented here a complete study on the interaction of 8a, 8d, 8e, 8h and 8i with AChE. Through fluorescence emission studies, the binding sites number found to be 1, binding constants were calculated as 2.04 × 104, 2.22 × 104, 1.18 × 104, 9.8 × 103 and 3.2 × 104 M−1 and free energy change as −5.83, −5.91, −5.51, −5.41 and −6.12 kcal M−1 at 25 °C which were well agreed with the computational calculations indicating a strong binding affinity of flavones and AChE. Furthermore, the CD studies revealed that the secondary structure of AChE became partly unfolded upon binding with 8a, 8d, 8e, 8h and 8i.  相似文献   

12.
The aim of this study is to evaluate microMOSFET as in-vivo dosimeter in 6 MV shaped-beam radiosurgery for field sizes down to 6 × 6 mm2. A homemade build-up cap was developed and its use with microMOSFET was evaluated down to 6 × 6 mm2. The study with the homemade build-up cap was performed considering its influence on field size over-cover occurring at surface, achievement of the overall process of electronic equilibrium, dose deposition along beam axis and dose attenuation. An optimized calibration method has been validated using MOSFET in shaped-beam radiosurgery for field sizes from 98 × 98 down to 18 × 18 mm2. The method was detailed in a previous study and validated in irregular field shapes series measurements performed on a head phantom. The optimized calibration method was applied to microMOSFET equipped with homemade build-up cap down to 6 × 6 mm2. Using the same irregular field shapes, dose measurements were performed on head phantom. MicroMOSFET results were compared to previous MOSFET ones. Additional irregular field shapes down to 8.8 × 8.8 mm2 were studied with microMOSFET. Isocenter dose attenuation due to the homemade build-up cap over the microMOSFET was near 2% irrespective of field size. Our results suggested that microMOSFET equipped with homemade build-up cap is suitable for in-vivo dosimetry in shaped-beam radiosurgery for field sizes down to 6 × 6 mm2 and therefore that the required build-up cap dimensions to perform entrance in-vivo dosimetry in small-fields have to ensure only partial charge particle equilibrium.  相似文献   

13.
A conductometric apparatus for determining the photosynthetic rate suitable predominantly for field measurements is described. In contrast with the hitherto described and applied instruments 3 samples of air can be analyzed here simultaneously, the data are temperature-independent and the entire electronic part of the apparatus is transistorized. The absorbers (300×30×30mm.) and the leaf chambers (140×100×10 mm.) are made of plexiglass. The membrane pump is hand-operated by means of a crank. The conductivity of the absorption solution (0.02N-KOH+0.5% isoamylalcohol+saponin) is measured in a special measuring cell into which the solution is transferred from the individual absorbers. The error of the photosynthetic rate determination is about 10-20% of the value obtained for intensities of 10-20 mg. CO2 dm.-2h.-1.  相似文献   

14.
PurposeAt introduction in 2014, dose calculation for the first MLC on a robotic SRS/SBRT platform was limited to a correction-based Finite-Size Pencil Beam (FSPB) algorithm. We report on the dosimetric accuracy of a novel Monte Carlo (MC) dose calculation algorithm for this MLC, included in the Precision™ treatment planning system.MethodsA phantom was built of one slab (5.0 cm) of lung-equivalent material (0.09…0.29 g/cc) enclosed by 3.5 cm (above) and 5 cm (below) slabs of solid water (1.045 g/cc). This was irradiated using rectangular (15.4 × 15.4 mm2 to 53.8 × 53.7 mm2) and two irregular MLC-fields. Radiochromic film (EBT3) was positioned perpendicular to the slabs and parallel to the beam. Calculated dose distributions were compared to film measurements using line scans and 2D gamma analysis.ResultsMeasured and MC calculated percent depth dose curves showed a characteristic dose drop within the low-density region, which was not correctly reproduced by FSPB. Superior average gamma pass rates (2%/1 mm) were found for MC (91.2 ± 1.5%) compared to FSPB (55.4 ± 2.7%). However, MC calculations exhibited localized anomalies at mass density transitions around 0.15 g/cc, which were traced to a simplification in electron transport. Absence of these anomalies was confirmed in a modified build of the MC engine, which increased gamma pass rates to 96.6 ± 1.2%.ConclusionsThe novel MC algorithm greatly improves dosimetric accuracy in heterogeneous tissue, potentially expanding the clinical use of robotic radiosurgery with MLC. In-depth, independent validation is paramount to identify and reduce the residual uncertainties in any software solution.  相似文献   

15.
Objectives: The aim of this study was to determine an optimal culture method for porcine bone marrow‐derived endothelial progenitor cells (EPCs). Materials and methods: Mononuclear cells (MNCs) were isolated by density centrifugation and differentiated into EPCs in in vitro. At first‐passage, EPCs were cultured at different cell densities (5 × 103, 1 × 104, 2 × 104 or 5 × 104/cm2) and in basic medium (EGM, medium 199, DMEM or 1640) supplemented with FBS (2%, 5%, 10% or 20%) and different combinations of cytokines (VEGF, VEGF + bFGF, VEGF + bFGF + EGF, or VEGF + bFGF + EGF + IGF), the experiment being based on L64 (421) orthogonal design. Results and conclusions: This demonstrated that the optimal culture method for our EPCs displayed higher expansion and migration rates as compared to other groups, by analysis of variance; that is, cultured at 1 × 104/cm2 in M199 supplemented with 10% FBS and VEGF + bFGF + IGF + EGF. Furthermore, percentage of positive cells stained by Dil‐ac‐LDL and FITC‐UEA‐1 was more than 65%, and as shown by immunohistochemistry, these cells also stained positively for CD133, CD34 and KDR. The present study indicates that the number and function of porcine EPCs significantly increased when using our optimized culture parameters.  相似文献   

16.
The mysterious death of Mr. Alexander Litvinenko who was most possibly poisoned by Polonium-210 (210Po) in November 2006 in London attracted the attention of the public to the kinetics, dosimetry and the risk of this high radiotoxic isotope in the human body. In the present paper, the urinary excretion of seven persons who were possibly exposed to traces of 210Po was monitored. The values measured in the GSF Radioanalytical Laboratory are in the range of natural background concentration. To assess the effective dose received by those persons, the time-dependence of the organ equivalent dose and the effective dose after acute ingestion and inhalation of 210Po were calculated using the biokinetic model for polonium (Po) recommended by the International Commission on Radiological Protection (ICRP) and the one recently published by Leggett and Eckerman (L&E). The daily urinary excretion to effective dose conversion factors for ingestion and inhalation were evaluated based on the ICRP and L&E models for members of the public. The ingestion (inhalation) effective dose per unit intake integrated over one day is 1.7 × 10−8 (1.4 × 10−7) Sv Bq−1, 2.0 × 10−7 (9.6 × 10−7) Sv Bq−1 over 10 days, 5.2 × 10−7 (2.0 × 10−6) Sv Bq−1 over 30 days and 1.0 × 10−6 (3.0 × 10−6) Sv Bq−1 over 100 days. The daily urinary excretions after acute ingestion (inhalation) of 1 Bq of 210Po are 1.1 × 10−3 (1.0 × 10−4) on day 1, 2.0 × 10−3 (1.9 × 10−4) on day 10, 1.3 × 10−3 (1.7 × 10−4) on day 30 and 3.6 × 10−4 (8.3 × 10−5) Bq d−1 on day 100, respectively. The resulting committed effective doses range from 2.1 × 10−3 to 1.7 × 10−2 mSv by an assumption of ingestion and from 5.5 × 10−2 to 4.5 × 10−1 mSv by inhalation. For the case of Mr. Litvinenko, the mean organ absorbed dose as a function of time was calculated using both the above stated models. The red bone marrow, the kidneys and the liver were considered as the critical organs. Assuming a value of lethal absorbed dose of 5 Gy to the bone marrow, 6 Gy to the kidneys and 8 Gy to the liver, the amount of 210Po which Mr. Litvinenko might have ingested is therefore estimated to range from 27 to 1,408 MBq, i.e 0.2–8.5 μg, depending on the modality of intake and on different assumptions about blood absorption.  相似文献   

17.
A diatomaceous earth formulation enhanced with bitterbarkomycin (DEBBM) combined with Beauveria bassiana (Balsamo) Vuillemin was evaluated against lesser grain borer Rhyzopertha dominica F. (Coleoptera: Bostrychidae) under laboratory conditions. DEBBM was applied at the rates of 15 and 30 ppm alone as well as in combination with 6.69 × 106, 6.69 × 108 and 6.69 × 1010 conidia/kg of wheat. Mortality of treated adults was recorded after 5, 10 and 15 days of exposure. Bioassays were carried out at 20, 25 and 30°C with 55 and 75% relative humidity. The emergence of progeny was also assessed 60 days post exposure. The combined use of DEBBM and B. bassiana considerably increased adult mortality especially at increasing temperatures and longer exposure intervals compared with DEBBM and B. bassiana alone. Progeny production was less in wheat treated with high dose rates of DEBBM +B. bassiana. The per cent mycosis in the cadavers was maximum where B. bassiana was applied at low dose rates. The results of the present study indicated that a combination of DEBBM and B. bassiana may provide effective control of R. dominica.  相似文献   

18.
19.
Mean protein and volume of 222 blastocysts collected on 6 to 9 days of pregnancy were measured. Embryo protein differed (P < 0.05) for each day of development studied. Protein content of embryos doubled between days 6 and 7 and days 7 and 8 (1.2 ± 0.04, 2.0 ± 0.14, and 3.7 ± 0.2 μg, respectively). A dramatic increase from 3.7 ± 0.2 to 56.0 ± 3.4 μg was observed between days 8 and 9. Blastocyst volume increased (P < 0.05) from 0.56 ± 0.03 × 10?2mm3 to 1.11 ± 0.04 × 10?2mm3 between days 6 and 7, and then increased 10-fold on day 8 and five-fold on day 9. Blastocyst volume was not correlated with protein for days of development and females studied. Approximately 20% of all blastocysts within a single female contained less protein than the average protein content of all embryos from the same uterus. The results indicate that day 6 of development marks the onset of an exponential increase in embryo protein. Also, blastocyst volume is not correlated with blastocyst protein, suggesting that embryo viability is difficult to estimate by size alone. Further, approximately 20% of the blastocysts collected from a single female may exhibit reduced viability, based on reduced protein content, as early as day 6 of development.  相似文献   

20.
Viridibacillus arenosi strain IHB B 7171 identified based on 16S rRNA gene sequence produced colony forming units (cfu/ml) ranging from 3.3 × 104 to 1.2 × 1010 under pH 5–11, 2.2 × 102 to 1.4 × 1010 for temperature 5–40 °C, 2.4 × 102 to 1.1 × 1010 for PEG 6000 10–30%, 2.2 × 102 to 1.4 × 1010 for 2.5–10% NaCl, 3.1 × 103 to 1.7 × 109 for 2.5–7.5 mM CaCl2, 2.2 × 102 to 1.4 × 107 for 2.5–7.5 mM AlCl3, and 3.2 × 102 to 1.2 × 107 for 2.5–7.5 mM FeCl3. The activities of plant growth-promoting attributes with the increasing acidity, desiccation and salinity ranged from 408 to 101, 20 to 8, 14 to 5 µg/ml P-liberated from tri-calcium phosphate, aluminium phosphate and iron phosphate, 20–9% siderophore units, 14–4 µg/ml IAA and 190–16 α-ketobutyrate h/mg protein ACC-deaminase activity. Plant height, leaf number, and leaf weight on treatment with bacterial inoculum showed an increment of 9.5, 17.6, 54.5 and 31.0% in tea seedlings, respectively. The bacterium also enhanced plant height and yield by 10 and 13% in pea and 2.8 and 13.9% in wheat. The results exhibited stress-tolerance and plant growth-promoting activities by the strain under stressed growth-conditions with potential as a broad-spectrum plant growth-promoting rhizobacterium.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号