首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 286 毫秒
1.
L Song  Q Zhou  P Duan  P Guo  D Li  Y Xu  S Li  F Luo  Z Zhang 《PloS one》2012,7(8):e42569
Small-diameter (<4 mm) vascular constructs are urgently needed for patients requiring replacement of their peripheral vessels. However, successful development of constructs remains a significant challenge. In this study, we successfully developed small-diameter vascular constructs with high patency using our integrally designed computer-controlled bioreactor system. This computer-controlled bioreactor system can confer physiological mechanical stimuli and fluid flow similar to physiological stimuli to the cultured grafts. The medium circulating system optimizes the culture conditions by maintaining fixed concentration of O(2) and CO(2) in the medium flow and constant delivery of nutrients and waste metabolites, as well as eliminates the complicated replacement of culture medium in traditional vascular tissue engineering. Biochemical and mechanical assay of newly developed grafts confirm the feasibility of the bioreactor system for small-diameter vascular engineering. Furthermore, the computer-controlled bioreactor is superior for cultured cell proliferation compared with the traditional non-computer-controlled bioreactor. Specifically, our novel bioreactor system may be a potential alternative for tissue engineering of large-scale small-diameter vascular vessels for clinical use.  相似文献   

2.
Much effort has been devoted to develop and advance the methodology to regenerate functional small-diameter arterial bypasses. In the physiological environment, both mechanical and chemical stimulation are required to maintain the proper development and functionality of arterial vessels1,2.Bioreactor culture systems developed by our group are designed to support vessel regeneration within a precisely controlled chemo-mechanical environment mimicking that of native vessels. Our bioreactor assembly and maintenance procedures are fairly simple and highly repeatable3,4. Smooth muscle cells (SMCs) are seeded onto a tubular polyglycolic acid (PGA) mesh that is threaded over compliant silicone tubing and cultured in the bioreactor with or without pulsatile stimulation for up to 12 weeks. There are four main attributes that distinguish our bioreactor from some predecessors. 1) Unlike other culture systems that simulate only the biochemical surrounding of native blood vessels, our bioreactor also creates a physiological pulsatile environment by applying cyclic radial strain to the vessels in culture. 2) Multiple engineered vessels can be cultured simultaneously under different mechanical conditions within a controlled chemical environment. 3) The bioreactor allows a mono layer of endothelial cells (EC) to be easily coated onto the luminal side of engineered vessels for animal implantation models. 4) Our bioreactor can also culture engineered vessels with different diameter size ranged from 1 mm to 3 mm, saving the effort to tailor each individual bioreactor to fit a specific diameter size. The engineered vessels cultured in our bioreactor resemble native blood vessels histologically to some degree. Cells in the vessel walls express mature SMC contractile markers such as smooth muscle myosin heavy chain (SMMHC)3. A substantial amount of collagen is deposited within the extracellular matrix, which is responsible for ultimate mechanical strength of the engineered vessels5. Biochemical analysis also indicates that collagen content of engineered vessels is comparable to that of native arteries6. Importantly, the pulsatile bioreactor has consistently regenerated vessels that exhibit mechanical properties that permit successful implantation experiments in animal models3,7. Additionally, this bioreactor can be further modified to allow real-time assessment and tracking of collagen remodeling over time, non-invasively, using a non-linear optical microscopy (NLOM)8. To conclude, this bioreactor should serve as an excellent platform to study the fundamental mechanisms that regulate the regeneration of functional small-diameter vascular grafts.Download video file.(69M, mov)  相似文献   

3.
The in vitro replication of physiological mechanical conditioning through bioreactors plays a crucial role in the development of functional Small-Caliber Tissue-Engineered Blood Vessels. An in silico scaffold-specific model under pulsatile perfusion provided by a bioreactor was implemented using a fluid-structure interaction (FSI) approach for viscoelastic tubular scaffolds (e.g. decellularized swine arteries, DSA). Results of working pressures, circumferential deformations, and wall shear stress on DSA fell within the desired physiological range and indicated the ability of this model to correctly predict the mechanical conditioning acting on the cells-scaffold system. Consequently, the FSI model allowed us to a priori define the stimulation pattern, driving in vitro physiological maturation of scaffolds, especially with viscoelastic properties.  相似文献   

4.
Electrospinning is a commonly used and versatile method to produce scaffolds (often biodegradable) for 3D tissue engineering.1, 2, 3 Many tissues in vivo undergo biaxial distension to varying extents such as skin, bladder, pelvic floor and even the hard palate as children grow. In producing scaffolds for these purposes there is a need to develop scaffolds of appropriate biomechanical properties (whether achieved without or with cells) and which are sterile for clinical use. The focus of this paper is not how to establish basic electrospinning parameters (as there is extensive literature on electrospinning) but on how to modify spun scaffolds post production to make them fit for tissue engineering purposes - here thickness, mechanical properties and sterilisation (required for clinical use) are considered and we also describe how cells can be cultured on scaffolds and subjected to biaxial strain to condition them for specific applications.Electrospinning tends to produce thin sheets; as the electrospinning collector becomes coated with insulating fibres it becomes a poor conductor such that fibres no longer deposit on it. Hence we describe approaches to produce thicker structures by heat or vapour annealing increasing the strength of scaffolds but not necessarily the elasticity. Sequential spinning of scaffolds of different polymers to achieve complex scaffolds is also described. Sterilisation methodologies can adversely affect strength and elasticity of scaffolds. We compare three methods for their effects on the biomechanical properties on electrospun scaffolds of poly lactic-co-glycolic acid (PLGA).Imaging of cells on scaffolds and assessment of production of extracellular matrix (ECM) proteins by cells on scaffolds is described. Culturing cells on scaffolds in vitro can improve scaffold strength and elasticity but the tissue engineering literature shows that cells often fail to produce appropriate ECM when cultured under static conditions. There are few commercial systems available that allow one to culture cells on scaffolds under dynamic conditioning regimes - one example is the Bose Electroforce 3100 which can be used to exert a conditioning programme on cells in scaffolds held using mechanical grips within a media filled chamber.4 An approach to a budget cell culture bioreactor for controlled distortion in 2 dimensions is described. We show that cells can be induced to produce elastin under these conditions. Finally assessment of the biomechanical properties of processed scaffolds cultured with or without cells is described.  相似文献   

5.
Small-diameter vascular grafts are potential substitutes for damaged vessels in patients, but most biodegradable grafts available now are not strong enough. The present study examined the burst strength, radial compliance, suture retention strength for a novel biodegradable tubular scaffold and investigated its behavior in vivo. The tubular scaffold (6-mm i.d., 4 cm long) has three layers including porous polylacticglycolic- acid in both inner and outer layers, a compact polyurethanes layer in midst. Bone marrow stromal cells (bMSCs) were seeded on the scaffolds and cultured for 7 days in vitro to construct tissue engineered vascular grafts which were then implanted in canine abdominal aorta. After 1, 3, 6, 12 and 24 weeks, the grafts were retrieved and evaluated histologically, angiographically and immunohistochemically. The biodegradable tubular scaffolds showed wall thickness of 0.295 mm to 0.432 mm; radial compliance of 3.80%/100 mmHg approximately 0.57%/100 mmHg, burst strength of 160 kPa approximately 183 kPa, and suture retention strength of 1959 N/cm(2) approximately 3228N/cm(2). The implanted grafts were fully patent without any signs of dilation or obstruction after 3 months' implantation. Scanning electron microscopy revealed a confluence endothelial cell layer spreading on the inner surface of the grafts. Immunohistochemistry of the retrieved grafts showed that vWF-stainin, alphaSMA-staining were positive in the inner and medium layer respectively. Masson's trichrome staining showed that amount of collagen fibers existed in the grafts wall. Overall, these novel three-layered scaffolds exhibited favourable mechanical strength, long term patency and good remodeling in vivo.  相似文献   

6.
In tissue engineering, flow perfusion bioreactors can be used to enhance nutrient diffusion while mechanically stimulating cells to increase matrix production. The goal of this study was to design and validate a dynamic flow perfusion bioreactor for use with compliant scaffolds. Using a non-permanent staining technique, scaffold perfusion was verified for flow rates of 0.1-2.0 mL/min. Flow analysis revealed that steady, pulsatile and oscillatory flow profiles were effectively transferred from the pump to the scaffold. Compared to static culture, bioreactor culture of osteoblast-seeded collagen-GAG scaffolds led to a 27-34% decrease in cell number but stimulated an 800-1200% increase in the production of prostaglandin E(2), an early-stage bone formation marker. This validated flow perfusion bioreactor provides the basis for optimisation of bioreactor culture in tissue engineering applications.  相似文献   

7.
Cell-based tissue engineering is limited by the size of cell-containing constructs that can be successfully cultured in vitro. This limit is largely a result of the slow diffusion of molecules such as oxygen into the interior of three-dimensional scaffolds in static culture. Bioreactor culture has been shown to overcome these limits. In this study we utilize a tubular perfusion system (TPS) bioreactor for the three-dimensional dynamic culture of human mesenchymal stem cells (hMSCs) in spherical alginate bead scaffolds. The goal of this study is to examine the effect of shear stress in the system and then quantify the proliferation and differentiation of hMSCs in different radial annuli of the scaffold. Shear stress was shown to have a temporal effect on hMSC osteoblastic differentiation with a strong correlation of shear stress, osteopontin, and bone morphogenic protein-2 occurring on day 21, and weaker correlation occurring at early timepoints. Further results revealed an approximate 2.5-fold increase in cell number in the inner annulus of TPS cultured constructs as compared to statically cultured constructs after 21 days. This result demonstrated a nutrient transfer limitation in static culture which can be mitigated by dynamic culture. A significant increase (P < 0.05) in mineralization in the inner and outer annuli of bioreactor cultured 4 mm scaffolds occurred on day 21 with 79 ± 29% and 53 ± 25% mineralization area, respectively, compared to 6 ± 4% and 19 ± 6% mineralization area, respectively, in inner and outer annuli of 4 mm statically cultured scaffolds. Surprising lower mineralization area was observed in 2 mm bioreactor cultured beads which had the highest levels of proliferation. These results may demonstrate a relationship between scaffold position and stem cell fate. In addition the decreased proliferation and matrix production in statically cultured scaffolds compared to bioreactor cultured constructs demonstrate the need for bioreactor systems and the effectiveness of the TPS bioreactor in promoting hMSC proliferation and differentiation in three-dimensional scaffolds.  相似文献   

8.
Cardiac tissue engineering presents a challenge due to the complexity of the muscle tissue and the need for multiple signals to induce tissue regeneration in vitro. We investigated the effects of compression (1 Hz, 15% strain) combined with fluid shear stress (10?2–10?1 dynes/cm2) provided by medium perfusion on the outcome of cardiac tissue engineering. Neonatal rat cardiac cells were seeded in Arginine‐Glycine‐Aspartate (RGD)‐attached alginate scaffolds, and the constructs were cultivated in a compression bioreactor. A daily, short‐term (30 min) compression (i.e., “intermittent compression”) for 4 days induced the formation of cardiac tissue with typical striation, while in the continuously compressed constructs (i.e., “continuous compression”), the cells remained spherical. By Western blot, on day 4 the expression of the gap junction protein connexin 43 was significantly greater in the “intermittent compression” constructs and the cardiomyocyte markers (α‐actinin and N‐cadherin) showed a trend of better preservation compared to the noncompressed constructs. This regime of compression had no effect on the proliferation of nonmyocyte cells, which maintained low expression level of proliferating cell nuclear antigen. Elevated secretion levels of basic fibroblast growth factor and transforming growth factor‐β in the daily, intermittently compressed constructs likely attributed to tissue formation. Our study thus establishes the formation of an improved cardiac tissue in vitro, when induced by combined mechanical signals of compression and fluid shear stress provided by perfusion. © 2012 American Institute of Chemical Engineers Biotechnol. Prog., 2012  相似文献   

9.
It is generally accepted that dynamic culture conditions are required for vascular tissue engineering. We compared the effects of two dynamic culture systems, a perfusion and a rotating bioreactor, using tubular constructs based on hyaluronic acid seeded with porcine aortic smooth muscle cells (SMC), that we recently showed to be adequate for the generation of vascular tissue. In perfused constructs mechanical stimulation importantly affected cell morphology, increased the incidence of cell proliferation and reduced apoptosis. However, extracellular matrix deposition, cytoskeletal organization and mechanical properties were poor. In rotated constructs cell proliferation was also higher and apoptosis lower than in static controls. Rotated constructs showed the highest ultimate stress and the lowest elastic modulus. Our data indicate that the rotating bioreactor is more efficient than the perfusion bioreactor and we then suggest that this method can be considered a valid alternative to complex bioreactor systems described in the literature.  相似文献   

10.
The anterior cruciate ligament (ACL) is the most commonly injured intra-articular ligament of the knee. The insufficient vascularization of this tissue prevents it from healing completely after extreme tearing or rupture, creating a need for ACL grafts for reconstruction. The limitations of existing grafts have motivated the investigation of tissue-engineered ACL grafts. A successful tissue-engineered graft must possess mechanical properties similar to the ACL; to date no commercially available synthetic graft has achieved this. To accomplish this goal we have combined the techniques of polymer fiber braiding and twisting to design a novel poly L-lactic acid (PLLA) braid-twist scaffold for ACL tissue engineering. The scaffold is designed to accurately mimic the biomechanical profile and mechanical properties of the ACL. In this study, braid-twist scaffolds were constructed and compared to braided scaffolds and twisted fiber scaffolds. The addition of fiber twisting to the braided scaffold resulted in a significant increase in the ultimate tensile strength, an increase in ultimate strain, and an increase in the length of the toe region in these constructs over scaffolds that were braided. Based on the findings of this study, the braid-twist scaffold studied was found to be a promising construct for tissue engineering of the ACL.  相似文献   

11.
We investigated the performance of small-caliber polyurethane (PU) small-diameter vascular prosthesis generated using the electrospinning technique. PU was electrospun into small-diameter, small-caliber tubular scaffolds for potential application as vascular grafts. We investigated the effects of electrospinning conditions (solution concentration, mandrel rotation speed) on the microstructure and porosity of the scaffolds for the purpose of preparing scaffolds with optimum microstructures and properties. We evaluated the mechanical properties of the scaffolds by tensile tests and the cytotoxicity of the PU small-diameter, small-caliber PU synthetic vascular graft by the MTT assay. The adhesion of endothelial cells to the PU scaffold was characterized by Hoechst staining and fluorescence microscopy, and we measured endothelial cell proliferation on the PU scaffold by the CCK-8 assay. We analyzed the prosthesis microstructure and endothelial cell morphology using scanning electron microscopy. With increasing PU concentration in the electrospinning solution, the fiber diameter of the vascular graft increased and the porosity decreased. In addition, with increasing electrospinning time, the wall thickness increased and the porosity decreased. We found that regular fiber orientation can be obtained by adjusting the rotation speed of the mandrel. Cell proliferation was not inhibited as the small-caliber PU synthetic vascular grafts showed little cytotoxicity. The endothelial cells had faster adherence to the PU scaffolds than to the PTFE surface during the initial contact. After prolonged cell culture, significantly higher endothelial cell proliferation rate was observed in the PU scaffold groups than the PTFE group. We obtained small-caliber PU vascular grafts with optimal fiber arrangement, excellent mechanical properties, and optimal biocompatibility by optimizing the electrospinning conditions. This study provides in vitro biocompatibility data that is helpful for the clinical application of the PU small-diameter, small-caliber PU vascular grafts.  相似文献   

12.
Developments in bioprocessing technology play an important role for overcoming challenges in cardiac tissue engineering. To this end, our laboratory has developed a novel rotary perfused bioreactor for supporting three-dimensional cardiac tissue engineering. The dynamic culture environments provided by our novel perfused rotary bioreactor and/or the high-aspect rotating vessel produced constructs with higher viability and significantly higher cell numbers (up to 4 × 105 cells/bead) than static tissue culture flasks. Furthermore, cells in the perfused rotary bioreactor showed earlier gene expressions of cardiac troponin-T, α- and β-myosin heavy chains with higher percentages of cardiac troponin-I-positive cells and better uniformity of sacromeric α-actinin expression. A dynamic and perfused environment, as provided by this bioreactor, provides a superior culture performance in cardiac differentiation for embryonic stem cells particularly for larger 3D constructs.  相似文献   

13.
Computational models of mechanobiological systems have been widely used to provide insight into these systems and also to predict their behaviour. In this context, vascular tissue engineering benefits from further attention given the challenges involved in developing functional low calibre vascular grafts with long-term patency. In this study, a novel multiscale mechanobiological modelling framework is presented, which takes advantage of lattice-free agent-based models coupled with the finite element method to investigate the dynamics of VSMC growth in vascular tissue engineering scaffolds. The results illustrate the ability of the mechanobiological modelling approach to capture complex multiscale mechanobiological phenomena. Specifically, the framework enabled the study of the influence of scaffold compliance and loading regime in regulating the growth of VSMCs in vascular scaffolds and their role in development of intimal hyperplasia (IH). The model demonstrates that low scaffold compliance compared to host arteries leads to increased luminal ingrowth and IH development. In addition, culture of a tissue-engineered blood vessel under a pulsatile luminal pressure reduced luminal ingrowth and enhanced collagen synthesis within the scaffold compared to non-pulsatile culture. The mechanobiological framework presented provides a robust platform for testing hypotheses in vascular tissue engineering and lends itself to use as an optimisation design tool.  相似文献   

14.
Wendt D  Stroebel S  Jakob M  John GT  Martin I 《Biorheology》2006,43(3-4):481-488
In this work, we assessed whether culture of uniformly seeded chondrocytes under direct perfusion, which supplies the cells with normoxic oxygen levels, can maintain a uniform distribution of viable cells throughout porous scaffolds several milimeters in thickness, and support the development of uniform tissue grafts. An integrated bioreactor system was first developed to streamline the steps of perfusion cell seeding of porous scaffolds and perfusion culture of the cell-seeded scaffolds. Oxygen tensions in perfused constructs were monitored by in-line oxygen sensors incorporated at the construct inlet and outlet. Adult human articular chondrocytes were perfusion-seeded into 4.5 mm thick foam scaffolds at a rate of 1 mm/s. Cell-seeded foams were then either cultured statically in dishes or further cultured under perfusion at a rate of 100 microm/s for 2 weeks. Following perfusion seeding, viable cells were uniformly distributed throughout the foams. Constructs subsequently cultured statically were highly heterogeneous, with cells and matrix concentrated at the construct periphery. In contrast, constructs cultured under perfusion were highly homogeneous, with uniform distributions of cells and matrix. Oxygen tensions of the perfused medium were maintained near normoxic levels (inlet congruent with 20%, outlet > 15%) at all times of culture. We have demonstrated that perfusion culture of cells seeded uniformly within porous scaffolds, at a flow rate maintaining a homogeneous oxygen supply, supports the development of uniform engineering tissue grafts of clinically relevant thicknesses.  相似文献   

15.
目的采用可降解的聚己内酯接枝肝素材料,负荷b-FGF(碱性成纤维细胞生长因子),体外构建的小口径组织工程血管,完成犬的股动脉移植动物实验。方法利用可降解的聚己内酯接枝肝素材料,电纺丝技术制备组织工程血管支架,并对支架负荷b-FGF生长因子,并进行材料的内皮细胞粘附实验。将体外构建的小口径组织工程血管,完成犬的股动脉移植动物实验,观察通畅率和移植术后组织工程血管的改变。结果可降解聚己内酯接枝肝素材料支架,负荷细胞生长因子(b-FGF),利于内皮细胞粘附。构建的组织工程血管进行体外动物实验构建,3个月移植物通畅率好,移植后取材,有新生内膜迁移和胶原纤维浸入。结论利用可降解聚己内酯接枝肝素材料构建小口径支架,初步符合构建组织工程血管支架的要求。  相似文献   

16.
Controlling environmental conditions, such as mechanical stimuli, is critical for directing cells into functional tissue. This study reports on the development of a bioreactor capable of controlling the mechanical environment and continuously measuring force‐displacement in engineered tissue. The bioreactor was built from off the shelf components, modified off the shelf components, and easily reproducible custom built parts to facilitate ease of setup, reproducibility and experimental flexibility. A T‐flask was modified to allow for four tissue samples, mechanical actuation via a LabView controlled stepper motor and transduction of force from inside the T‐flask to an external sensor. In vitro bench top testing with instrumentation springs and tissue culture experiments were performed to validate system performance. Force sensors were highly linear (R2 > 0.998) and able to maintain force readings for extended periods of time. Tissue culture experiments involved cyclic loading of polyurethane scaffolds seeded with and without (control) human foreskin fibroblasts for 8 h/day for 14 days. After supplementation with TGF‐β, tissue constructs showed an increase in stiffness between consecutive days and from the acellular controls. These experiments confirmed the ability of the bioreactor to distinguish experimental groups and monitor tissue stiffness during tissue development. © 2010 American Institute of Chemical Engineers Biotechnol. Prog., 2010  相似文献   

17.
During in vivo tissue regeneration, cell behavior is highly influenced by the surrounding environment. Thus, the choice of scaffold material and its microstructure is one of the fundamental steps for a successful in vitro culture. An efficacious method for scaffold fabrication should prove its versatility and the possibility of controlling micro- and nanostructure. In this paper, hyaluronic acid 3D scaffolds were developed through lamination of micropatterned membranes, fabricated after optimization of a soft-lithography method. The scaffold presented here is characterized by a homogeneous hexagonal lattice with porosity of 69%, specific surface area of 287 cm-1, and permeability of 18.9 microm2. The control over the geometry was achieved with an accuracy of 20 mum. This technique allowed not only fabrication of planar 3D scaffolds but also production of thin wall tubular constructs. Mechanical tests, performed on dry tubular scaffolds, show high rupture tensile strength. This construct could be promising not only as engineered vascular grafts but also for regeneration of skin, urethra, and intestinal walls. The biocompatibility of a 3D planar scaffold was tested by seeding human fibroblasts. The cells were cultured in both static and dynamic conditions, in a perfusion bioreactor at different flow rates. Microscope analysis and MTT test showed cell proliferation and viability and a uniform cell distribution likely due to an appropriate lattice structure.  相似文献   

18.
体外组织工程模型中,生物化学和机械信号对心肌再生起着很重要的促进作用,对人胰岛素样生长因子(IGF-1)和三维动态微环境对脂肪干细胞向心肌细胞分化过程中的促进作用进行了研究.带有IGF-1基因的质粒整合到胶原-壳聚糖支架中,脂肪干细胞接种到整合质粒的支架内,未整合质粒的支架作为对照组,心肌细胞培养基作为分化培养基,转瓶生物反应器提供动态微环境.经2周分化培养后,检测质粒在支架内释放及表达情况、细胞在支架内的活性以及心肌功能性蛋白和基因的表达.结果表明:动态微环境能促进质粒DNA的释放和转染;IGF-1可促进脂肪干细胞在胶原-壳聚糖支架内增殖以及向心肌细胞分化;动态微环境可加强IGF-1的促增殖分化作用.因此,IGF-1和动态微环境能独立或相互促进脂肪干细胞在胶原-壳聚糖支架内活性,动态微环境还可强化IGF-1对脂肪干细胞的促分化作用.对体外构建工程化心肌组织进行心肌再生研究有着重要的指导意义.  相似文献   

19.
Throughout native artery, collagen and elastin play an important role, providing a mechanical backbone, preventing vessel rupture, and promoting recovery under pulsatile deformations. The goal of this study was to mimic the structure of native artery by fabricating a multi-layered electrospun conduit composed of poly(caprolactone) (PCL) with the addition of elastin and collagen with blends of 45-45-10, 55-35-10, and 65-25-10 PCL-ELAS-COL to demonstrate mechanical properties indicative of native arterial tissue, while remaining conducive to tissue regeneration. Whole grafts and individual layers were analyzed using uniaxial tensile testing, dynamic compliance, suture retention, and burst strength. Compliance results revealed that changes to the middle/medial layer changed overall graft behavior with whole graft compliance values ranging from 0.8 - 2.8 % / 100 mmHg, while uniaxial results demonstrated an average modulus range of 2.0 - 11.8 MPa. Both modulus and compliance data displayed values within the range of native artery. Mathematical modeling was implemented to show how changes in layer stiffness affect the overall circumferential wall stress, and as a design aid to achieve the best mechanical combination of materials. Overall, the results indicated that a graft can be designed to mimic a tri-layered structure by altering layer properties.  相似文献   

20.
Renal function and continence of urine are critically dependent on the proper function of the urinary bladder, which stores urine at low pressure and expels it with a precisely orchestrated contraction. A number of congenital and acquired urological anomalies including posterior urethral valves, benign prostatic hyperplasia, and neurogenic bladder secondary to spina bifida/spinal cord injury can result in pathologic tissue remodeling leading to impaired compliance and reduced capacity1. Functional or anatomical obstruction of the urinary tract is frequently associated with these conditions, and can lead to urinary incontinence and kidney damage from increased storage and voiding pressures2. Surgical implantation of gastrointestinal segments to expand organ capacity and reduce intravesical pressures represents the primary surgical treatment option for these disorders when medical management fails3. However, this approach is hampered by the limitation of available donor tissue, and is associated with significant complications including chronic urinary tract infection, metabolic perturbation, urinary stone formation, and secondary malignancy4,5.Current research in bladder tissue engineering is heavily focused on identifying biomaterial configurations which can support regeneration of tissues at defect sites. Conventional 3-D scaffolds derived from natural and synthetic polymers such as small intestinal submucosa and poly-glycolic acid have shown some short-term success in supporting urothelial and smooth muscle regeneration as well as facilitating increased organ storage capacity in both animal models and in the clinic6,7. However, deficiencies in scaffold mechanical integrity and biocompatibility often result in deleterious fibrosis8, graft contracture9, and calcification10, thus increasing the risk of implant failure and need for secondary surgical procedures. In addition, restoration of normal voiding characteristics utilizing standard biomaterial constructs for augmentation cystoplasty has yet to be achieved, and therefore research and development of novel matrices which can fulfill this role is needed.In order to successfully develop and evaluate optimal biomaterials for clinical bladder augmentation, efficacy research must first be performed in standardized animal models using detailed surgical methods and functional outcome assessments. We have previously reported the use of a bladder augmentation model in mice to determine the potential of silk fibroin-based scaffolds to mediate tissue regeneration and functional voiding characteristics.11,12 Cystometric analyses of this model have shown that variations in structural and mechanical implant properties can influence the resulting urodynamic features of the tissue engineered bladders11,12. Positive correlations between the degree of matrix-mediated tissue regeneration determined histologically and functional compliance and capacity evaluated by cystometry were demonstrated in this model11,12. These results therefore suggest that functional evaluations of biomaterial configurations in rodent bladder augmentation systems may be a useful format for assessing scaffold properties and establishing in vivo feasibility prior to large animal studies and clinical deployment. In the current study, we will present various surgical stages of bladder augmentation in both mice and rats using silk scaffolds and demonstrate techniques for awake and anesthetized cystometry.  相似文献   