首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
目的:探讨肺静脉口弧形指数与心房颤动(房颤)导管消融术后复发的关系。方法:选取2008年2月至2011年3月在我院接受导管消融术的房颤患者120例,所有患者于术前3日内利用多排CT行左心房及肺静脉造影,并进行图像的三维重建。测量每条肺静脉前后径及上下径,并计算弧形指数(肺静脉前后径/肺静脉上下径)以描述肺静脉口形态。行射频消融治疗的房颤病人全部达消融终点,术后随访超过3个月,根据患者房性快速性心律失常(房颤、房扑或房速)的发生情况,将其分为治愈组和复发组,进行统计分析。结果:由弧形指数分析,四支肺静脉开口形态存在统计学差异(P0.05);房颤消融术后,53例病人复发。房颤消融术后复发患者的LIPV弧形指数与治愈者不同,差异有显著性(P0.05);两组患者的左上肺静脉(Left Superior Pulmonary Vein,LSPV),右上肺静脉(Right Superior Pulmonary Vein,RSPV),右肺下静脉(Right Inferior Pulmonary Vein,RIPV),的弧形指数比较差异不明显(P0.05)。结论:左下肺静脉形态的不一致性与房颤导管消融术复发有关。  相似文献   

2.

Atrial fibrillation (AF) is part of a vicious cycle that includes multiple cardiovascular risk factors and comorbidity which can promote atrial remodelling and AF progression. Most AF-related risk factors—hypertension, diabetes, sleep apnoea, obesity and sedentary lifestyle—are in essence modifiable which may prevent AF development. Treatment of associated cardiovascular conditions may prevent both symptoms and future cardiovascular events. For advanced forms of symptomatic AF refractory to lifestyle management and optimal medication, invasive ablation therapies have become a cornerstone. Although electrical trigger isolation from the pulmonary veins is reasonably effective and safe, more potent energy sources including high output-short duration radiofrequency, ultra-low cryo-energy, and electroporation, as well as more sophisticated arrays, balloons, and lattice-tipped catheter tools, are on their way to eliminate existing pitfalls and simplify the procedure. Electroanatomical navigation and mapping systems are becoming available to provide real-time information on ablation lesion quality and the critical pathways of AF in the individual patient to guide more extensive ablation strategies that may enhance long-term outcome for freedom of advanced AF. Surgical techniques, either stand-alone or concomitant to structural cardiac repair, hybrid, or convergent, with novel less invasive access options are developing and can be helpful in situations unsuitable for catheter ablation.

  相似文献   

3.
The thoracic vein hypothesis of chronic atrial fibrillation (AF) posits that rapid, repetitive activations from muscle sleeves within thoracic veins underlie the mechanism of sustained AF. If this is so, thoracic vein ablation should terminate sustained AF and prevent its reinduction. Six female mongrel dogs underwent chronic pulmonary vein (PV) pacing at 20 Hz to induce sustained (>48 h) AF. Bipolar electrodes were used to record from the atria and thoracic veins, including the vein of Marshall, four PVs, and the superior vena cava. Radio frequency (RF) application was applied around the PVs and superior vena cava and along the vein of Marshall until electrical activity was eliminated. Computerized mapping (1,792 electrodes, 1 mm resolution) was also performed. Sustained AF was induced in 30.6 +/- 6.5 days, and ablation was done 17.3 +/- 8.5 days afterward. Before ablation, the PVs had shorter activation cycle lengths than the atria, and rapid, repetitive activations were observed in the PVs. All dogs converted to sinus rhythm during (n = 4 dogs) or within 90 min of completion of RF ablation. Rapid atrial pacing afterward induced only nonsustained (<60 s) AF in all dogs. Average AF cycle lengths after reinduction were significantly (P = 0.01) longer (183 +/- 31.5 ms) than baseline (106 +/- 16.2 ms). There were no activation cycle length gradients after RF application. We conclude that thoracic vein ablation converts canine sustained AF into sinus rhythm and prevents the reinduction of sustained AF. These findings suggest that thoracic veins are important in the maintenance of AF in dogs.  相似文献   

4.

Introduction

Recurrence of atrial fibrillation after pulmonary vein isolation (PVI) occurs frequently and may be associated with electrical reconnection of the pulmonary veins (PV). We investigated spatial distribution of electrical reconnection during re-do procedures in patients with paroxysmal atrial fibrillation who had previous successful acute electrical PVI with either single irrigated tip, antral ablation (s-RF; n = 38) or multi-electrode, duty-cycled ablation (PVAC; n = 48).

Methods and Results

EP navigator, mapping and irrigated tip ablation catheters were used in all re-do procedures. Sites of reconnection were assessed in a 12-segment model. Baseline clinical and demographic characteristics were similar in both groups. The number of PVs reconnected per patient was similar in both groups (2.9 ± 0.9 and 3.2 ± 0.7 (p = 0.193), s?RF and PVAC, respectively), and each PV was equally affected. However, the inferior quadrant of the right lower PV was significantly more vulnerable to reconnection after previous PVAC ablation, whereas the superior quadrant of the right upper PV showed significantly more reconnection in the s?RF group.

Conclusion

The overall number of PVs reconnected was equally high in both groups, and each PV was affected equally. However, there were significant differences in the spatial distribution of electrical reconnection. Better understanding of predilection sites for reconnection might help to improve the long-term success rate of PVI.
  相似文献   

5.
目的: 比较在持续性房颤发生、发展过程中,房颤模型山羊左心房与肺静脉外膜碎裂电位(CFAEs)的变化,以期探讨肺静脉外膜碎裂电位(CFAEs)在持续性房颤中的作用。方法: 选取10只雌性山羊,使用左心房快速刺激,发送输出电压为6 V、周长为20 ms的脉冲1 s,间隔2 s后重复发放,以此方法建立持续性房颤模型(房颤持续>24 h),平均刺激时间为(9.5±2.3)d。在整个房颤发生、发展过程中,记录并比较刺激前后左心房及肺静脉外膜CFAEs的动态变化。结果: 随着刺激时间延长,心房不应期(AERP)逐渐缩短,房颤持续时间逐渐延长,左心房及肺静脉外膜的CFAEs逐渐增多,肺静脉外膜CFAEs的比例始终多于左心房。当房颤持续24 h,肺静脉外膜CFAEs几乎持续存在(房颤初发与房颤持续24 h相比,2.7%±3.6% vs 92.6%±6.4%,P<0.05),肺静脉外膜CFAEs比例明显高于左心房(P<0.05)。结论: 心外膜CFAEs具有位置特异性,与电重构相关联。房颤发生发展中心外膜CFAEs逐渐增多,可能在房颤的维持中起重要作用。  相似文献   

6.
7.
Isolation of the pulmonary veins has been used as surgical treatment for atrial fibrillation (AF) from the early 90s, as it was incorporated in the Maze procedure. With the evidence that triggers form this area can induce AF, the Maze III procedure has been adapted and modified towards a single lesion around the pulmonary veins for the treatment of paroxysmal and chronic AF in some centers. New ablation techniques with a diversity of energy sources further paved the way for less invasive procedures. Minimal invasive techniques to prevent major surgery may potentially make the treatment available for a patient population that do not have to undergo cardiac surgery for other reasons. Besides these technical developments, high density mapping can be used to identify the AF substrate in the individual patient and optimization of the treatment by local substrate guided ablation. This review aims to summarize the robotic and thoracoscopic techniques to isolate the pulmonary veins. Furthermore, it is discussed why pulmonary veins isolation may be effective in patients with chronic AF, and whether there is a role for mapping guided minimal invasive surgical treatment of AF in the near future.  相似文献   

8.
The development of pulmonary vein stenosis has recently been described after radiofrequency ablation (RF) to treat atrial fibrillation (AF). The purpose of this study was to examine expression of TGFβ1 in pulmonary vein stenosis after radiofrequency ablation in chronic atrial fibrillation of dogs. About 28 mongrel dogs were randomly assigned to the sham-operated group (n = 7), the AF group (n = 7), AF + RF group (n = 7), and RF group (n = 7). In AF or AF + RF groups, dogs underwent chronic pulmonary vein (PV) pacing to induce sustained AF. RF application was applied around the PVs until electrical activity was eliminated. Histological assessment of pulmonary veins was performed using hematoxylin and eosin staining; TGFβ1 gene expression in pulmonary veins was examined by RT-PCR analysis; expression of TGFβ1 protein in pulmonary veins was assessed by Western blot analysis. Rapid pacing from the left superior pulmonary vein (LSPV) induced sustained AF in AF group and AF + RF group. Pulmonary vein ablation terminated the chronic atrial fibrillation in dogs. Histological examination revealed necrotic tissues in various stages of collagen replacement, intimal thickening, and cartilaginous metaplasia with chondroblasts and chondroclasts. Compared with sham-operated and AF group, TGFβ1 gene and protein expressions was increased in AF + RF or RF groups. It was concluded that TGFβ1 might be associated with pulmonary vein stenosis after radiofrequency ablation in chronic atrial fibrillation of dogs. Shufeng Li and Hongli Li contributed equally to the work.  相似文献   

9.
BackgroundThe Arctic Front Cryoballoon System is a technology in which substrate alterations in patients with atrial fibrillation (AF) recurrence have not been well characterized. In this study, we evaluated sites of pulmonary vein (PV) reconnections and the accuracy of the Achieve? circular mapping catheter in detecting these reconnections after cryoablation.MethodsThis study included 15 patients undergoing redo AF ablation after a prior single cryoablation procedure. PV reconnection sites were determined by measuring PV signals and high output pacing from 4 vectors of the Achieve catheter. The results were compared with a roving mapping catheter guided by rotational intracardiac echocardiography (ICE) in the left atrium.ResultsAll patients had PV reconnections (2.1 ± 0.8 veins/patient). The left superior PV was most commonly reconnected (n = 11), whereas the right inferior PV was least likely (n = 3). Both carinas (left: n = 11; right: n = 7) and left atrial appendage ridge (n = 11) were also frequently reconnected. Mapping with the Achieve catheter showed a positive predictive value (PPV) 100% and negative predictive value (NPV) 96% when compared with ICE guided mapping. In 2 patients, right superior PV reconnection was not identified by the Achieve.ConclusionDuring redo AF ablation after index cryoablation, multiple PVs are usually reconnected, with both carinas and left atrial appendage ridge being common sites of reconnection. The Achieve mapping catheter was able to identify reconnection with high positive and negative predictive values.  相似文献   

10.

Background  

Pulmonary veins (PVs) are the most important sources of ectopic beats with the initiation of paroxysmal atrial fibrillation, or the foci of ectopic atrial tachycardia and focal atrial fibrillation. Elimination of nitric oxide (NO) enhances cardiac triggered activity, and NO can decrease PV arrhythmogensis through mechano-electrical feedback. However, it is not clear whether NO may have direct electrophysiological effects on PV cardiomyocytes. This study is aimed to study the effects of nitroprusside (NO donor), on the ionic currents and arrhythmogenic activity of single cardiomyocytes from the PVs.  相似文献   

11.

Objective

Reconduction across an ablation line is a common reason for arrhythmia recurrence over time. The hybrid procedure combines epicardial ablation of the pulmonary vein (PV) and creation of a box lesion with endocardial touch-ups for any electrical gaps. A high contact force (CF) between the ablation tip and cardiac tissue may increase the risk of thrombus formation, catheter tip charring, steam pop formation, and even cardiac perforation. CF monitoring is a significant new parameter for titration of the CF for creating an adequate lesion.

Methods

Thirty-eight consecutive patients underwent epicardial ablation using bipolar radiofrequency devices. After checking electrical bidirectional block of the ablation lines, an endocardial CF catheter was used for further ablation (if needed) to complete the isolation of PVs, box lesion, cavotricuspid isthmus (CTI), and complex fractionated atrial electrograms (CFAE).

Results

Endocardial touch-up was needed for 2 PVs (1.3 %) and 10 (26.3 %) box lesions. It was also used for the CTI line in 7 (18.4 %) patients, atrial tachycardia in 3 (7.9 %) patients, and additional CFAE ablation in 17 (44.7 %) patients. All 5 patients with arrhythmia recurrence had a mean CF < 10 g (p = 0.03). Procedure duration was significantly shorter in the CF group (223 ± 57 vs. 256 ± 60 min, p = 0.03) compared with control group.

Conclusion

Use of CF catheters is safe, feasible, and complementary to a hybrid procedure setup for atrial fibrillation ablation. Its real-time monitoring may predict future arrhythmia recurrence, and decrease procedure time.  相似文献   

12.

Background

Recent community-based research has linked aortic stiffness to the development of atrial fibrillation. We posit that aortic stiffness contributes to adverse atrial remodeling leading to the persistence of atrial fibrillation following catheter ablation in lone atrial fibrillation patients, despite the absence of apparent structural heart disease. Here, we aim to evaluate aortic stiffness in lone atrial fibrillation patients and determine its association with arrhythmia recurrence following radio-frequency catheter ablation.

Methods

We studied 68 consecutive lone atrial fibrillation patients who underwent catheter ablation procedure for atrial fibrillation and 50 healthy age- and sex-matched community controls. We performed radial artery applanation tonometry to obtain central measures of aortic stiffness: pulse pressure, augmentation pressure and augmentation index. Following ablation, arrhythmia recurrence was monitored at months 3, 6, 9, 12 and 6 monthly thereafter.

Results

Compared to healthy controls, lone atrial fibrillation patients had significantly elevated peripheral pulse pressure, central pulse pressure, augmentation pressure and larger left atrial dimensions (all P<0.05). During a mean follow-up of 2.9±1.4 years, 38 of the 68 lone atrial fibrillation patients had atrial fibrillation recurrence after initial catheter ablation procedure. Neither blood pressure nor aortic stiffness indices differed between patients with and without atrial fibrillation recurrence. However, patients with highest levels (≥75th percentile) of peripheral pulse pressure, central pulse pressure and augmentation pressure had higher atrial fibrillation recurrence rates (all P<0.05). Only central aortic stiffness indices were associated with lower survival free from atrial fibrillation using Kaplan-Meier analysis.

Conclusion

Aortic stiffness is an important risk factor in patients with lone atrial fibrillation and contributes to higher atrial fibrillation recurrence following catheter ablation procedure.  相似文献   

13.
In selected patients with atrial fibrillation and severe symptoms, non-pharmacological treatment may be an alternative or supplement to drug therapy. Atrioventricular nodal radiofrequency ablation (requires pacemaker implantation), or atrial pacing for sick sinus syndrome, are established treatment modalities. All other non-pharmacological therapies for atrial fibrillation are still experimental. After the Maze operation, atrial depolarization has to follow one specific path determined by surgical scars in the myocardium. This prevents new episodes of atrial fibrillation, but at a cost of perioperative morbidity and mortality. Catheter-based "Maze-like" radiofrequency ablation is technically difficult, and thrombo-embolic complications may occur. Paroxysmal atrial fibrillation sometimes is initiated by spontaneous depolarizations in a pulmonary vein inlet. Radio frequency ablation against such focal activity has been reported with high therapeutic success, but the results await confirmation from several centres. For ventricular rate control, most electrophysiologists presently prefer ablation to induce a complete atrioventricular conduction block (with pacemaker) rather than trying to modify conduction by incomplete block. Atrial or dual chamber pacing may prevent atrial fibrillation induced by bradycardia. It remains to confirm that biatrial or multisite right atrial pacing prevents atrial fibrillation more efficiently than ordinary right atrial pacing. An atrial defibrillator is able to diagnose and convert atrial fibrillation. The equipment is expensive, and therapy without sedation may be unpleasant beyond tolerability.  相似文献   

14.
BackgroundThe single procedure success rates of durable pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (PAF) varies between 80 and 90%. Ablation index, incorporating contact force, stability, time and power is a more profound parameter of significant lesion size and has been established. Equally important is a stringent contiguity of the lesion set.Methods and resultsA total number of 100 consecutive patients undergoing de-novo catheter ablation for paroxysmal atrial fibrillation (PAF) were analyzed between 2016 and 2019. In the first 50 patients (group A) PVI was performed using a surround flow, contact force catheter (Biosense Webster Thermocool STSF, Biosense Webster, USA) with a drag-and-ablate technique to encircle the PVs. In the following 50 patients (group B), PVI was performed using ablation index and a stringent lesion contiguity with an interlesion distance (ILD) of <5 mm. The baseline characteristics showed no significant differences between both groups. During a mean follow-up of 18 ± 3 months after a single procedure, 36 (72%) patients of group A were free of arrhythmia recurrence versus 43 (86%) patients in group B (p = 0.047). A total of 14 patients (group A: 10 (20%), group B: 4 (8%); underwent a redo-procedure. 7 patients of group A (14%) and 2 patients of group B (4%) showed recovered veins. In 3 patients of group A and 2 patients of group B the PVs were durably isolated. In these patients persistent AF recurrence was caused by extra-PV AF sources. Four patients of group A and three patients of group B had continued paroxysmal or persistent AF but did not undergo redo-procedure. With regard to the procedural data, the procedure time, the total energy and the fluoroscopy time were significantly lower in group B (AI and ILD <5 mm) (128.86 ± 18.19 versus 115.35 ± 15.38; p < 0.05; 1619.16 ± 988.56 versus 1186.26 ± 756.34; p < 0.05; 11.49 ± 3.20 versus 9.66 ± 3.86; p = 0.04). Both procedures were performed with a low number of complications, no pericardial effusion was seen in either group.ConclusionsPVI using ablation index in combination with a stringent lesion contiguity improves clinical outcome after first-time PVI with lower PVI recovery, shorter procedure times, lower total energy and shorter fluoroscopy times and therefore, is more efficient.  相似文献   

15.
Mitral isthmus ablation forms part of the electrophysiologist's armoury in the catheter ablation treatment of atrial fibrillation. It is well recognised however, that mitral isthmus ablation is technically challenging and incomplete ablation may be pro-arrhythmic, leading some to question its role. This article first reviews the evidence for the use of adjunctive mitral isthmus ablation and its association with the development of macroreentrant perimitral flutter. It then describes the practical techniques of mitral isthmus ablation, with particular emphasis on the assessment of bi-directional mitral isthmus block. The anatomy of the mitral isthmus is also discussed in order to understand the possible obstacles to successful ablation. Finally, novel techniques which may facilitate mitral isthmus ablation are reviewed.  相似文献   

16.
Focal point-by-point radiofrequency catheter ablation has shown considerable success in the treatment of paroxysmal atrial fibrillation. However, it is not without limitations. Recent clinical and preclinical studies have demonstrated that cryothermal ablation using a balloon catheter (Artic Front©, Medtronic CryoCath LP) provides an effective alternative strategy to treating atrial fibrillation. The objective of this article is to review efficacy and safety data surrounding cryoballoon ablation for paroxysmal and persistent atrial fibrillation. In addition, a practical step-by-step approach to cryoballoon ablation is presented, while highlighting relevant literature regarding: 1) the rationale for adjunctive imaging, 2) selection of an appropriate cryoballoon size, 3) predictors of efficacy, 4) advanced trouble-shooting techniques, and 5) strategies to reduce procedural complications, such as phrenic nerve palsy.  相似文献   

17.
Pulmonary vein isolation (PVI) using radiofrequency current (RFC) ablation is a potentially curative treatment option for patients with atrial fibrillation (AF). The shortcomings of the RFC technology (technically challenging, long procedure times, complications) steadily kindle the interest in new energy sources and catheter designs. High intensity focused ultrasound (HIFU) has the ability to precisely focus ultrasound waves in a defined area with a high energy density. HIFU balloon catheters (BC) positioned at the PV ostia appear to be an ideal tool to transmit the ablation energy in a circumferential manner to the PV ostia and may therefore bear substantial advantage over conventional ablation catheters in PVI procedures. In clinical trials the HIFU BC has shown promising success rates similar to RFC catheter ablation for PVI in patients with AF. However, procedure times are still long and serious complications have been observed. Therefore, it may be a valuable alternative to the conventional techniques in selected patients but further clinical trials have to be initiated.  相似文献   

18.
Persistent left superior vena cava is a rarely seen anomaly but it may be an arrhythmogenic source for paroxysmal atrial fibrillation. Furthermore, the complex anatomicregion between the left superior vena cava and the pulmonary veins may leads to misinterpretation of the pulmonary vein recordings during atrial fibrillation ablation. Approaches that might be helpful to overcome these problems are discussed in this case report.  相似文献   

19.
Atrial flutter ablation is associated with a high rate of acute procedural success and symptom improvement. The relationship between ablation and other clinical outcomes has been limited to small studies primarily conducted at academic centers. We sought to determine if catheter ablation of atrial flutter is associated with reductions in healthcare utilization, atrial fibrillation, or stroke in a large, real world population. California Healthcare Cost and Utilization Project databases were used to identify patients undergoing atrial flutter ablation between 2005 and 2009. The adjusted association between atrial flutter ablation and healthcare utilization, atrial fibrillation, or stroke was investigated using Cox proportional hazards models. Among 33,004 patients with a diagnosis of atrial flutter observed for a median of 2.1 years, 2,733 (8.2%) underwent catheter ablation. Atrial flutter ablation significantly lowered the adjusted risk of inpatient hospitalization (HR 0.88, 95% CI 0.84–0.92, p<0.001), emergency department visits (HR 0.60, 95% CI 0.54–0.65, p<0.001), and overall hospital-based healthcare utilization (HR 0.94, 95% CI 0.90–0.98, p = 0.001). Atrial flutter ablation was also associated with a statistically significant 11% reduction in the adjusted hazard of atrial fibrillation (HR 0.89, 95% CI 0.81–0.97, p = 0.01). Risk of acute stroke was not significantly reduced after ablation (HR 1.09, 95% CI 0.81–1.45, p = 0.57). In a large, real world population, atrial flutter ablation was associated with significant reductions in hospital-based healthcare utilization and a reduced risk of atrial fibrillation. These findings support the early use of catheter ablation for the treatment of atrial flutter.  相似文献   

20.
Percutenous catheter ablation of the accessory pathway in Wolff-Parkinson-White syndrome is a highly successful mode of therapy. Sudden cardiac arrest survivors associated with WPW syndrome should undergo radiofrequency catheter ablation. WPW syndrome associated with familial atrial fibrillation is a very rare condition. Herein, we describe a case who presented with sudden cardiac arrest secondary to WPW syndrome and familial atrial fibrillation and treated via radiofrequency catheter ablation.  相似文献   