A sensitive and simple method for real-time detection of inorganic pyrophosphatase (PPase) (EC 3.6.1.1) activity has been developed. The method is based on PPase-induced activation of the firefly luciferase activity in the presence of inorganic pyrophosphate (PPi). PPi inhibits the luciferase activity, but in the presence of PPase the luciferase activity is restored and the luminescence output increases. The assay yields linear responses between 8 and 500 mU. The detection limit was found to be 8 mU PPase. The method was used to detect the hydrolytic activity of PPases from Saccharomyces cerevisiae, Escherichia coli, and Bacillus stearothermophilus. As substrate for the luciferase, adenosine 5'-phosphosulfate can replace ATP, which is an advantage for detection of PPase activity in crude extracts containing ATP-hydrolyzing activities. The method can be used for kinetic and inhibition studies as well as for detection of PPase activity during different purification procedures.  相似文献   

2.
Inorganic pyrophosphate was measured by luminescence produced by a pyrophosphatase (NAD adenylyl-transferase or ATP sulfurylase) coimmobilized with firefly luciferase on Sepharose beads, with continuous flow of saturating concentrations of substrates (NAD plus luciferin or adenylophosphosulfate plus luciferin, respectively) and intermittent injections of samples containing pyrophosphate. In this scheme, the limiting substrate (pyrophosphate) is regenerated, a situation that is well suited to a bioluminescent assay. The instrumentation allowed for automation with a through-put of approximately one sample every 4 min. With standard solutions or samples that do not contain ATP, the sensitivity of the assay permits detection of less than 1 pmol pyrophosphate in a volume of 20 microliters (50 nmol/liter) with a coefficient of variation approximately equal to 4%. To assay biological samples, it was shown that endogenous ATP can be inactivated by oxidation with sodium periodate. Periodate treatment and quenching engenders dilution that limits the sensitivity to approximately 600 nmol/liter pyrophosphate in the starting material. The assay has been applied to the determination of intracellular pyrophosphate in human lymphocytes and to the measurement of nucleoside-triphosphate pyrophosphohydrolase in human fibroblasts. The variability of the assay was greater with biological samples than with standard samples, with a coefficient of variation of 15.3% in a series of determinations of intracellular pyrophosphate in a series of replicate lymphocyte lysates. Bioluminescent systems of coupled coimmobilized enzymes offer great promise for sensitive, safe, automated assaying of metabolites.  相似文献   

3.
A sensitive method for the analysis of inorganic pyrophosphate (PPi) which utilizes the enzymes ATP sulfurylase and firefly luciferase is described. The assay is based on continuous monitoring of the ATP formed in the ATP sulfurylase reaction using purified firefly luciferase. The assay can be completed in less than 2 s and is not affected by inorganic phosphate. The method has been used for continuous monitoring of formation of PPi in Rhodospirillum rubrum chromatophores. The assay is extremely sensitive, the linear range of the assay being 1 X 10(-9) - 5 X 10(-7) M PPi. It is suitable for routine applications. It is also possible to use the method for determination of low amounts of adenosine 5'-phosphosulfate.  相似文献   

4.
A real-time, sensitive, and simple assay for detection and quantification of adenosine triphosphate sulfurylase (ATP:sulfate adenylytransferase, EC 2.7.7.4) activity has been developed. The method is based on detection of ATP generated in the ATP sulfurylase reaction between APS and PPi by the firefly luciferase system. For the Saccharomyces cerevisiae ATP sulfurylase, the concentrations of APS and PPi at the half-maximal rate were found to be about 0.5 and 7 microM, respectively. The assay is sensitive and yields linear response between 0.1 microU and 50 mU. The method can be used for monitoring and quantification of recombinant ATP sulfurylase activity in Escherichia coli lysate, as well as for detection of the activity during different purification procedures.  相似文献   

5.
We constructed a novel ATP amplification reactor using a continuous-flow system, and this allowed us to increase the sensitivity of a quantitative bioluminescence assay by controlling the number of ATP amplification cycles. We previously developed a bioluminescence assay coupled with ATP amplification using a batch system. However, it was difficult to control the number of amplification cycles. In this study, ATP amplification was performed using a continuous-flow system, and significant linear correlations between amplified luminescence and initial ATP concentration were observed. When performing four cycles of continuous-flow ATP amplification, the gradient of amplification was 1.87N. Whereas the lower quantifiable level was 500 pM without amplification, values as low as 50 pM ATP could be measured after amplification. The sensitivity thus increased 10-fold, with further improvements expected with additional amplification cycles. The continuous-flow system thus effectively increased the sensitivity of the quantitative bioluminescence assay.  相似文献   

6.
DNA probe immobilization on plastic surfaces and device assembly are both critical to the fabrication of microfluidic hybridization array channel (MHAC) devices. Three oligonucleotide (oligo) probe immobilization procedures were investigated for attaching oligo probes on four different types of plastic surfaces (polystyrene, polycarbonate, poly(methylmethacrylate), and polypropylene). These procedures are the Surmodics procedure, the cetyltrimethylammonium bromide (CTAB) procedure, and the Reacti-Bind procedure. To determine the optimal plastic substrate and attachment chemistry for array fabrication, we investigated plastic hydrophobicity, intrinsic fluorescence, and oligo attachment efficiency. The Reacti-Bind procedure is least effective for attaching oligo probes in the microarray format. The CTAB procedure performs well enough to use in array fabrication, and the concentration of CTAB has a significant effect on oligo immobilization efficiency. We also found that use of amine-modified oligo probes resulted in better immobilization efficiency than use of unmodified oligos with the CTAB procedure. The oligo probe immobilization on plastic surfaces by the Surmodics procedure is the most effective with regard to probe spot quality and hybridization sensitivity. A DNA hybridization assay on such a device results in a limit of detection of 12pM. Utilizing a CO(2) IR laser machining and adhesive layer approach, we have developed an improved procedure for realizing a DNA microarray inside a microfluidic channel. This device fabrication procedure allows for more feasible spot placement in the channel and reduced sample adsorption by adhesive tapes used in the fabrication procedure. We also demonstrated improved hybridization kinetics and increased detection sensitivity in MHAC devices by implementing sample oscillation inside the channel. A limit of detection of 5pM has been achieved in MHAC devices with sample oscillation.  相似文献   

7.
Sensing of pyrophosphate ion (PPi) has received much attention due to the strong demand for clinical diagnostics. Here, based on gold nanoclusters (Au NCs), a ratiometric optical detection method for PPi is developed by simultaneously detecting the dual signals of fluorescence (FL) and second-order scattering (SOS). The PPi is detected by inhibiting the formation of aggregates of Fe3+ with Au NCs. Binding of Fe3+ to Au NCs causes aggregation of Au NCs, which leads to fluorescence quenching and scattering increasing. The presence of PPi can competitively bind Fe3+ to re-disperse the Au NCs and finally recover the fluorescence and reduce the scattering signal. The designed PPi sensor shows a high sensitivity with a linear range 5–50 μM and a detection limit of 1.2 μM. In addition, the assay has excellent selectivity for PPi, which makes its application in real biological samples extremely valuable.  相似文献   

8.
A multiplex single-nucleotide polymorphism (SNP) typing platform using ‘bioluminometric assay coupled with terminator [2′,3′-dideoxynucleoside triphosphates (ddNTPs)] incorporation’ (named ‘BATI’ for short) was developed. All of the reactions are carried out in a single reaction chamber containing target DNAs, DNA polymerase, reagents necessary for converting PPi into ATP and reagents for luciferase reaction. Each of the four ddNTPs is dispensed into the reaction chamber in turn. PPi is released by a nucleotide incorporation reaction and is used to produce ATP when the ddNTP dispensed is complementary to the base in a template. The ATP is used in a luciferase reaction to release visible light. Only 1 nt is incorporated into a template at a time because ddNTPs do not have a 3′ hydroxyl group. This feature greatly simplifies a sequencing spectrum. The luminescence is proportional to the amount of template incorporated. Only one peak appears in the spectrum of a homozygote sample, and two peaks at the same intensity appear for a heterozygote sample. In comparison with pyrosequencing using dNTP, the spectrum obtained by BATI is very simple, and it is very easy to determine SNPs accurately from it. As only one base is extended at a time and the extension signals are quantitative, the observed spectrum pattern is uniquely determined even for a sample containing multiplex SNPs. We have successfully used BATI to type various samples containing plural target sequence areas. The measurements can be carried out with an inexpensive and small luminometer using a photodiode array as the detector. It takes only a few minutes to determine multiplex SNPs. These results indicate that this novel multiplexed approach can significantly decrease the cost of SNP typing and increase the typing throughput with an inexpensive and small luminometer.  相似文献   

9.
A quantitative bioluminescence assay for rapid and sensitive microRNA (miRNA) expression analysis was developed. The assay uses miRNA directly as a primer for binding to a circular single-stranded DNA template, followed by rolling circle amplification. The detection of inorganic pyrophosphate (PPi) molecules released during the DNA polymerization and amplification process is performed by a multi-enzyme system. PPi is converted to ATP by ATP-sulfurylase, which provides energy for luciferase to oxidize luciferin and produce light. Experimental results show that the assay has a dynamic range exceeding three orders of magnitude and the ability to discriminate miRNAs with high-homology sequences. Quantification of nine miRNAs in human heart tissues demonstrated high cross-platform consistency between this assay and the TaqMan real-time polymerase chain reaction (PCR) assay with R(2)=0.941. The assay requires fewer reagents, can be performed at an isothermal condition without thermal cycling, and is capable of detecting miRNAs in less than 1h. Compared with the real-time PCR and microarray-based detection methods, this assay provides a simpler, faster, and less expensive platform for miRNA quantification in life science research, drug discovery, and clinical diagnosis.  相似文献   

10.
A high-sensitivity assay has been developed for the detection of human topoisomerase I with single molecule resolution. The method uses magnetic sepharose beads to concentrate rolling circle products, produced by the amplification of DNA molecules circularized by topoisomerase I and detectable with a confocal microscope as single and discrete dots, once reacted with fluorescent probes. Each dot, corresponding to a single cleavage–religation event mediated by the enzyme, can be counted due to its high signal/noise ratio, allowing detection of 0.3 pM enzyme and representing a valid method to detect the enzyme activity in highly diluted samples.  相似文献   

11.
Bacteria monitoring is essential for many industrial manufacturing processes, particularly those involving in food, biopharmaceuticals, and semiconductor production. Firefly luciferase ATP luminescence assay is a rapid and simple bacteria detection method. However, the detection limit of this assay for Escherichia coli is approximately 104 colony-forming units (CFU), which is insufficient for many applications. This study aims to improve the assay sensitivity by simultaneous conversion of PPi and AMP, two products of the luciferase reaction, back to ATP to form two chain-reaction loops. Because each consumed ATP continuously produces two new ATP molecules, this approach can achieve exponential amplification of ATP. Two consecutive enzyme reactions were employed to regenerate AMP into ATP: adenylate kinase converting AMP into ADP using UTP as the energy source, and acetate kinase catalyzing acetyl phosphate and ADP into ATP. The PPi-recycling loop was completed using ATP sulfurylase and adenosine 5′ phosphosulfate. The modification maintains good quantification linearity in the ATP luminescence assay and greatly increases its bacteria detection sensitivity. This improved method can detect bacteria concentrations of fewer than 10 CFU. This exponential ATP amplification assay will benefit bacteria monitoring in public health and manufacturing processes that require high-quality water.  相似文献   

12.
A novel bioluminescent enzymatic cycling assay for ATP and AMP with concomitant use of firefly luciferase and pyruvate orthophosphate dikinase (PPDK) was developed. In this system, AMP and pyrophosphate produced from ATP by firefly luciferase were converted back into ATP by PPDK. This resulted in constant luminescence once the stable phase had been reached. Background luminescence of the reagent was reduced with adenosine phosphate deaminase by degrading ATP and AMP in the reagent. The maximum recycling ratio calculated from the integrated luminescence value was 2.64 cycles/min. The measurable ranges for ATP and AMP were equal and were between 4 x 10(-13) and 4 x 10(-17) mol/assay. The amount of yeast RNA could be estimated in the range of 1 x 10(-8) to 1 x 10(-12) g/assay by estimating the amount of AMP resulting from the degradation of RNA with nuclease P1. Various food samples were subjected to measurement of the amount of ATP + AMP + RNA to provide an index for hygiene monitoring. For beef extract, sensitivity was improved by more than 20 million compared to the previous methods relying only on the amount of ATP as an index.  相似文献   

13.
A novel nonmetal optical probe ARC-1063 whose long-lifetime luminescence is induced by association with the target protein kinase is used for the measurement of the concentration of catalytic subunit of protein kinase A (PKAc) in complicated biological solutions. High affinity (K(D) = 10 pM toward PKAc) and unique optical properties of the probe enable its application for the measurement of picomolar concentrations of PKAc in the presence of high concentrations of other proteins. The described assay is applicable in the high-throughput format with the instrument setups designed for lanthanide-based time-gated (time-resolved) luminescence methods. The assay is used for demonstration that extracellular PKAc (ECPKA) is present in plasma samples of all healthy persons and cancer patients but great care must be taken for procedures of treatment of blood samples to avoid disruption, damage, or activation of platelets in the course of plasma (or serum) preparation and conservation.  相似文献   

14.
Photon imaging is an increasingly important technique for the measurement and analysis of chemiluminescence and bioluminescence. New high-performance low-light level imaging systems have recently become available for the life science. These systems use advances in camera design and digital image processing and are now being used for a wide range of luminescence applications. They offer good sensitivity for photon detection and large dynamic range, and are suitable for quantitative analysis. This is achieved using a range of software techniques including image arithmetic, histogramming or summing regions of interest, feature extraction and multiple image processing for kinetics or assay screening. Improvements in imageprocessing hardware and software have increased the usefulness of these systems in the biosciences. Low-light imaging is a rapid and non-invasive method for the sensitive detection and analysis of luminescent assays. As such it offers a powerful and sensitive tool for investigating processes, both at the cellular level (luc and lux reporter genes, intracellular signalling) and for measurement of macro samples (immunoassays, gels and blots, tissue sections).  相似文献   

15.
A new spectrophotometric method for quantitation of acetyl-CoA synthetase (ACAS) activity is developed. It has been applied for ACAS assay in the liver tissues of a woodchuck model of hepatitis virus-induced hepatocellular carcinoma (HCC). The assay is based on the established pyrophosphate (PPi) detection system. ACAS activity is indexed by the amount of PPi, the product of ACAS reaction system of activated form of acetate (acetyl-CoA) with ACAS catalysis. PPi is determined quantitatively as the amount of chromophore formed with molybdate reagent, 1-amino-2-naphthol-4-sulfonic acid in bisulfite and 2-mercaptoethanol. PPi reacts with molybdate reagent to produce phosphomolybdate and PPi-molybdate complexes. 2-mercaptoethanol is responsible for color formation which has the peak absorbance at 580 nm. This method was sensitive from 1 to 20 nmol of PPi in a 380-mul sample (1-cm cuvette). A ten-fold excess of Pi did not interfere with the determination of PPi. To study the major metabolic pathways of imaging tracer [1-(11)C]-acetate in tumors for detection of HCC by Positron Emission Tomography (PET), the activity of one of the key enzymes involved in acetate or [1-(11)C]-acetate metabolism, ACAS was assayed by this newly developed assay in the tissue samples of woodchuck HCCs. A significant increase of ACAS activity was observed in the liver tissues of woodchuck HCCs as compared with neighboring regions surrounding the tumors (P<0.05). The respective ACAS activities in the subcellular locations were also significantly higher in HCCs than in the surrounding tissues (P<0.05) (total soluble fraction: 876.61+/-34.64 vs. 361.62+/-49.97 mU/g tissue; cytoplasmic fraction: 1122.02+/-112.39 vs. 732.32+/-84.44 mU/g tissue; organelle content: 815.79+/-100.77 vs. 547.91+/-97.05 mU/ g tissue; sedimentable fragment: 251.92+/-51.56 vs. 90.94+/-18.98 mU/ g tissue). The finding suggests an increase in ACAS activity in the liver cancer of woodchuck models of HCC as compared to that in the normal woodchuck liver. The developed assay is rapid, simple and accurate and is suitable for the investigation of ACAS activity under physiologic and pathophysiologic conditions.  相似文献   

16.
In this study, a highly sensitive capillary-based enzyme-linked immunosorbent assay (ELISA) has been developed for the analysis of picomolar levels of thrombin-cleaved osteopontin (trOPN), a potential biomarker for ischemic stroke, in human plasma. Using a square capillary coated with 8.5 μg/ml anti-human trOPN capture antibody for ELISA, the linear range obtained was 2 to 16 pM trOPN antigen. This concentration range was in the detection window of trOPN antigen in plasma samples. Compared with the conventional microplate-based ELISA, the current capillary technique significantly reduced the amounts of reagent from milliliter to microliter, reduced the analysis time from 8 to 3 h, and had a better sensitivity and detection limit performance from approximately 50 pM down to 2 pM of trOPN antigen. These results indicate that this capillary-based immunoassay is a potential tool for biomarker detection and may be useful in clinical trials and medical diagnostic applications.  相似文献   

17.
A continuous, coupled, spectrophotometric assay is described in which the enzyme ATP sulfurylase is employed to measure the concentration of inorganic pyrophosphate (PPi) at equilibrium with known concentrations of inorganic orthophosphate (Pi) in the presence of excess inorganic pyrophosphatase (PPitase). In agreement with previous reports, the apparent equilibrium constant (Keq,app) of the PPi hydrolysis reaction was shown to decrease as the concentration of Mg2+ is increased. At pH 7.3, 30 degrees C, in the presence of 150 mM NaCl and 1 mM free Mg2+, Keq,app (calculated as [Pi]t2/[PPi]t) was 1950. Measurements of Keq,app at different total concentrations of Mg2+ and Pi permitted the determination of K0, the dissociation constant of the Mg-Pi complex. In 0.05 M Tris-Cl, pH 8.0, at 30 degrees C, K0 was 3.6 mM. In the presence of excess ATP sulfurylase, yeast PPitase catalyzed PPi formation from Pi with a specific activity (Vmax) of 9 units X mg protein-1 at pH 8.0, 30 degrees C, and 1 mM free Mg2+. Half-maximum reverse reaction velocity was observed at a total Pi concentration of 18 mM. (Under the same conditions, Vmax of the PPi hydrolysis reaction was 530 units X mg protein-1.) A radiochemical end point ("reaction-to-completion") assay for measuring unknown concentrations of PPi was devised. In the presence of excess 35S-adenosine-5'-phosphosulfate ([35S]APS) as the cosubstrate, 35SO2-4 formation was stoichiometric with added PPi. (The 35SO2-4 and [35S]APS are separated by adsorption of the latter onto charcoal.) The sensitivity of the assay can be adjusted by varying the specific radioactivity of the [35S]APS. In the absence of interfering substances, as little as 2 pmol of PPi per 1.0 ml assay volume can be measured. The sensitivity of the assay is reduced in the presence of ATP plus perchlorate (which synergistically inhibit the enzyme). However, if the bulk of the ATP is removed from perchloric acid extracts of tissues with glucose and hexokinase, initial intracellular levels as low as 1 microM can be measured. The possibility that most of the cellular PPi extracted with perchloric acid was originally enzyme bound is discussed.  相似文献   

18.
Ubiquitin activating enzyme (UAE, UBE1, or E1) and seven known homologous “E1s” initiate the conjugation pathways for ubiquitin and 16 other ubiquitin-like modifiers (ULMs) found in humans. The initial step catalyzed by E1s uses adenosine triphosphate (ATP) to adenylate the C terminus of the appropriate ULM and results in the production of inorganic pyrophosphate (PPi). The mechanism of these enzymes can be studied with assays that measure the rate of ULM-dependent ATP:PPi exchange. The traditional method follows the initial velocity of [32P]PPi incorporation into ATP by capturing the nucleotide on activated charcoal powder to separate it from excess [32P]PPi and then measuring [32P]ATP in a scintillation counter. We have modified the method by using charcoal paper to capture the nucleotide and a phosphorimager to quantify the [32P]ATP. The significant increase in throughput that these modifications provide is accomplished without any sacrifice in sensitivity or accuracy compared with the traditional method. To demonstrate this, we reproduce and extend the characterization of the NEDD8 activating enzyme.  相似文献   

19.
Nucleoside triphosphate pyrophosphohydrolase (EC 3.6.1.8) activity is associated with matrix vesicles purified from collagenase digests of fetal calf epiphyseal cartilage. This enzyme hydrolyzes nucleoside triphosphates to nucleotides and PPi, the latter inducing precipitation in the presence of Ca2+ and Pi. An assay for matrix vesicle nucleoside triphosphate pyrophosphohydrolase is developed using beta, gamma-methylene ATP as substrate. The assay is effective in the presence of matrix vesicle-associated ATPase, pyrophosphatase, and alkaline phosphatase activities. A soluble nucleoside triphosphate pyrophosphohydrolase is obtained from matrix vesicles by treatment with 5 mM sodium deoxycholate. The solubilized enzyme induced the precipitation of calcium phosphate in the presence of ATP, Ca2+, and Pi. Extraction of deoxycholate-solubilized enzymes from matrix vesicles with 1-butanol destroys nucleoside triphosphate pyrophosphohydrolase activity while enhancing the specific activities of ATPase, pyrophosphatase, and alkaline phosphatase. In solutions devoid of ATP and matrix vesicles, concentrations of PPi between 10 and 100 microM induce calcification in mixtures containing initial Ca2+ X P ion products of 3.5 to 7.9 mM2. This finding plus the discovery of nucleoside triphosphate pyrophosphohydrolase in matrix vesicles supports the view that these extracellular organelles induce calcium precipitation by the enzymatic production of PPi. Nucleoside triphosphate pyrophosphohydrolase is more active against pyrimidine nucleoside triphosphates than the corresponding purine derivatives. The pH optimum is 10.0 and the enzyme is neither activated nor inhibited by Mg2+ or Ca2+ ions or mixtures of the two. Vmax at pH 7.5 for beta, gamma-methylene ATP is 0.012 mumol of substrate hydrolyzed per min per mg of protein and Km is below 10 microM. The enzyme is irreversibly destroyed at pH 4 and is stable at pH 10.5.  相似文献   

20.
A radioimmunoassay for the measurement of rat pancreatic polypeptide (RPP) in serum or plasma has been developed and characterized using a new guinea-pig anti-rat-PP antibody. The assay provides a high degree of sensitivity and lacks cross-reactivity (CR less than 0.01%) to neuropeptide Y and peptide YY. It also does not interact with PPs of other species or peptide hormones namely, amylin, glucagon, human insulin, human-PP, human-proinsulin, rat C-peptide and rat insulin. The assay employs synthetic rat PP as standards from concentrations of 21-2100 pg/ml (i.e., 5-500 pM) and produces a sensitivity limit of 19 pg/ml (4.5 pM) PP at +/- 3 S.D. The intra- and interassay % coefficient of variations are 6.4% and 5.9%, respectively. The % recovery of RPP added to rat serum samples ranges from 98% to 103%. Assay of serum volumes ranging from 25 microliters to 100 microliters does not significantly alter the expected RPP level. The migration patterns of rat serum PP and that of a synthetic RPP are identical by Sephadex G-50 chromatographic analysis. The mean values of fasting and a 2 h post-feeding plasma RPP levels in normal rats are 40 +/- 2 and 80 +/- 10 pg/ml (9.5 pM and 19.0 pM), respectively. Rat-PP release during insulin induced hypoglycemia in conscious rats rises from 38 +/- 5 pg/ml to 261 +/- 34 pg/ml (9.0 to 62.1 pM, P less than 0.005) by 30 min. Additionally, the antibody used in this study cross-reacts well with mouse-PP as determined by linear serum dilution curves, thus making it useful in the measurement of murine-PP. In conclusion, we have developed and validated a sensitive and specific rat-PP assay. This assay provides a new tool for the reliable measurement of PP in physiologic studies using rat and mouse animal models.  相似文献   