首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
Knowledge of the coupled motions, which develop under compressive loading of the knee, is useful to determine which degrees of freedom should be included in the study of tibiofemoral contact and also to understand the role of the anterior cruciate ligament (ACL) in coupled motions. The objectives of this study were to measure the coupled motions of the intact knee and ACL-deficient knee under compression and to compare the coupled motions of the ACL-deficient knee with those of the intact knee. Ten intact cadaveric knees were tested by applying a 1600 N compressive load and measuring coupled internal-external and varus-valgus rotations and anterior-posterior and medial-lateral translations at 0 deg, 15 deg, and 30 deg of flexion. Compressive loads were applied along the functional axis of axial rotation, which coincides approximately with the mechanical axis of the tibia. The ACL was excised and the knees were tested again. In the intact knee, the peak coupled motions were 3.8 deg internal rotation at 0 deg flexion changing to -4.9 deg external rotation at 30 deg of flexion, 1.4 deg of varus rotation at 0 deg flexion changing to -1.9 deg valgus rotation at 30 deg of flexion, 1.4 mm of medial translation at 0 deg flexion increasing to 2.3 mm at 30 deg of flexion, and 5.3 mm of anterior translation at 0 deg flexion increasing to 10.2 mm at 30 deg of flexion. All changes in the peak coupled motions from 0 deg to 30 deg flexion were statistically significant (p<0.05). In ACL-deficient knees, there was a strong trend (marginally not significant, p=0.07) toward greater anterior translation (12.7 mm) than that in intact knees (8.0 mm), whereas coupled motions in the other degrees of freedom were comparable. Because the coupled motions in all four degrees of freedom in the intact knee and ACL-deficient knee are sufficiently large to substantially affect the tibiofemoral contact area, all degrees of freedom should be included when either developing mathematical models or designing mechanical testing equipment for study of tibiofemoral contact. The increase in coupled anterior translation in ACL-deficient knees indicates the important role played by the ACL in constraining anterior translation during compressive loading.  相似文献   

2.
Knee instability following anterior cruciate ligament (ACL) rupture compromises function and increases risk of injury to the cartilage and menisci. To understand the biomechanical function of the ACL, previous studies have primarily reported the net change in tibial position in response to multiplanar torques, which generate knee instability. In contrast, we retrospectively analyzed a cohort of 13 consecutively tested cadaveric knees and found distinct motion patterns, defined as the motion of the tibia as it translates and rotates from its unloaded, initial position to its loaded, final position. Specifically, ACL-sectioned knees either subluxated anteriorly under valgus torque (VL-subluxating) (5 knees) or under a combination of valgus and internal rotational torques (VL/IR-subluxating) (8 knees), which were applied at 15 and 30° flexion using a robotic manipulator. The purpose of this study was to identify differences between these knees that could be driving the two distinct motion patterns. Therefore, we asked whether parameters of bony geometry and tibiofemoral laxity (known risk factors of non-contact ACL injury) as well as in situ ACL force, when it was intact, differentiate knees in these two groups. VL-subluxating knees exhibited greater sagittal slope of the lateral tibia by 3.6 ± 2.4° (p = 0.003); less change in anterior laxity after ACL-sectioning during a simulated Lachman test by 3.2 ± 3.2 mm (p = 0.006); and, at the peak applied valgus torque (no internal rotation torque), higher posteriorly directed, in situ ACL force by 13.4 ± 11.3 N and 12.0 ± 11.6 N at 15° and 30° of flexion, respectively (both p ≤ 0.03). These results may suggest that subgroups of knees depend more on their ACL to control lateral tibial subluxation in response to uniplanar valgus and multiplanar valgus and internal rotation torques as mediated by anterior laxity and bony morphology.  相似文献   

3.
The purpose of this study was to determine whether mechanical adaptations were present in patients with anterior cruciate ligament (ACL)-deficient knees during high-demand activities. Twenty-two subjects with unilateral ACL deficiency (11 males and 11 females, 19.6 months after injury) performed five different activities at a comfortable speed (level walking, ascending and descending steps, jogging, jogging to a 90-degree side cutting toward the opposite direction of the tested side). Three-dimensional knee kinematics for the ACL-deficient knees and uninjured contralateral knees were evaluated using the Point Cluster Technique. There was no significant difference in knee flexion angle, but an offset toward the knee in less valgus and more external tibial rotation was observed in the ACL-deficient knee. The tendency was more obvious in high demand motions, and a significant difference was clearly observed in the side cutting motions. These motion patterns, with the knee in less valgus and more external tibial rotation, are proposed to be an adaptive movement to avoid pivot shift dynamically, and reveal evidence in support of a dynamic adaptive motion occurring in ACL-deficient knees.  相似文献   

4.
In situ force in the anterior cruciate ligament (ACL) has been quantified both in vitro in response to relatively simple loads by means of robotic technology, as well as in vivo in response to more complex loads by means of force transducers and computational models. However, a methodology has been suggested to indirectly estimate the in situ forces in the ACL in a non-invasive, non-contact manner by reproducing six-degree of freedom (six-DOF) in vivo kinematics on cadaveric knees using a robotic/UFS testing system. Therefore, the objective of this study was to determine the feasibility of this approach. Kinematics from eight porcine knees (source knees) were collected at 30 degrees , 60 degrees , and 90 degrees of flexion in response to: (1) an anterior load of 100 N and (2) a valgus load of 5 N m. The average of each kinematic data set was reproduced on a separate set of eight knees (target knees). The in situ forces in the ACL were determined for both sets of knees and compared. Significant differences (rho<0.05) were found between the source knees and the target knees for all flexion angles in response to an anterior load. However, in response to valgus loads, there was no significant difference between the source knees and the target knees at 30 degrees and 90 degrees of flexion. It was noted that there was a correlation between anterior knee laxity (the distance along the displacement axis from the origin to the beginning of the linear region of the load-displacement curve) and internal-external rotation. These data suggest that in order to obtain reproducible results one needs to first match knees to knees with comparable anterior knee laxity. Thus, an estimate of the in situ forces in the ACL during in vivo activities might be obtainable using this novel methodology.  相似文献   

5.
An unconstrained loading system was developed to measure the passive envelope of joint motion in an animal model commonly used to study ligament healing and joint arthritis. The design of the five-degree-of-freedom system allowed for unconstrained knee joint loading throughout flexion with repeated removal and reapplication of the device to a specimen. Seven New Zealand White rabbit knees were subjected to varus, valgus, internal and external loads, and the resulting envelopes of motion were recorded using an electromagnetic tracking device. Intra-specimen reproducibility was excellent when measured in one specimen, with maximal rotational differences of 0.6 and 0.3 deg between the fourth and fifth testing cycles for the varus (VR) and valgus (VL) envelopes, respectively. Similarly, the maximal internal (INT) and external (EXT) envelope differences were 0.5 and 0.4 deg, respectively, between the fourth and fifth cycles. Good inter-animal envelope reproducibility was also observed with consistent motion pathways for each loading condition. A maximal VR-VL laxity of 17.9 +/- 2.3 deg was recorded at 95 deg flexion for the seven knees tested. The maximal INT-EXT laxity of 75.2 +/- 4.8 deg occurred at 50 deg flexion. Studies on measurement reproducibility of re-applying individual testing components demonstrated a maximal error of 1.2 +/- 0.7 deg. Serial removal and re-application (test-retest) of the complete measuring system to one cadaveric knee demonstrated maximal envelope differences of less than 0.7 deg for VR-VL rotation and 2.1 deg for INT-EXT rotation. Our results demonstrate that the measuring system is reproducible and capable of accurate evaluation of knee joint motion. Baseline in vitro data were generated on normal joint kinematics for future in-vivo studies with this system, evaluating ligament healing and disease progression in arthritis models.  相似文献   

6.
The aim of this cadaveric study was to describe the kinematics of the anterior cruciate ligament (ACL)-intact, posterolateral (PL) bundle-deficient and ACL-deficient knee by applying a protocol for computer-assisted evaluation of knee kinematics. The hypothesis that the PL bundle functions mainly at low knee flexion angles was tested. An optical tracking system was used to acquire knee joint motion on 10 knees during clinical evaluations by tracking markers rigidly attached to the bones. The protocol included acquisition of anterior-posterior (AP) translations and internal-external (IE) rotations, and evaluation of three clinical knee laxity tests (anterior drawer, manual and instrumented Lachman). The data demonstrated no significant contribution to AP translation and IE laxity from the PL bundle over the entire range of motion. The clinical knee laxity tests showed no significant differences between the ACL-intact and PL bundle-deficient states. The hypothesis could not be proven. Current clinical knee laxity measurements may not be suited for detecting subtle changes such as PL bundle deficiency in the ACL anatomy. The computation of knee laxity might be a step towards a more precise kinematic test of knee stability not only in the native and torn ACL state of the knee but also in the reconstructed knee.  相似文献   

7.
In this study, the force and stress distribution within the anteromedial (AM) and posterolateral (PL) bundles of the anterior cruciate ligament (ACL) in response to an anterior tibial load with the knee at full extension was calculated using a validated three-dimensional finite element model (FEM) of a human ACL. The interaction between the AM and PL bundles, as well as the contact and friction caused by the ACL wrapping around the bone during knee motion, were included in the model. The AM and PL bundles of the ACL were simulated as incompressible homogeneous and isotropic hyperelastic materials. The multiple-degrees-of-freedom (DOF) knee kinematics of a cadaveric knee were first obtained using a robotic/universal force-moment sensor testing system. These data were used as the boundary conditions for the FEM of the ACL to calculate the forces in the ACL. The calculated forces were compared to the in situ force in the ACL, determined experimentally, to validate the model. The validated FEM was then used to calculate the force and stress distribution within the ACL under an anterior tibial load at full extension. The AM and PL bundles shared the force, and the stress distribution was non-uniform within both bundles with the highest stress localized near the femoral insertion site. The contact and friction caused by the ACL wrapping around the bone during knee motion played the role of transferring the force from the ACL to the bone, and had a direct effect on the force and stress distribution of the ACL. This validated model will enable the analysis of force and stress distribution in the ACL in response to more complex loading conditions and has the potential to help design improved surgical procedures following ACL injuries.  相似文献   

8.
This study tested the hypotheses that in patients with a successful anterior cruciate ligament (ACL) reconstruction, the internal–external rotation, varus–valgus, and knee flexion position of reconstructed knees would be different from uninjured contralateral knees during walking. Twenty-six subjects with unilateral ACL reconstructions (avg 31 years, 1.7 m, 68 kg, 15 female, 24 months past reconstruction) and no other history of serious lower limb injury walked at a self-selected speed in the gait laboratory, with the uninjured contralateral knee as a matched control. Kinematic measurements of tibiofemoral motion were made using a previously-described point-cluster technique. Repeated-measures ANOVA (α=0.017) was used to compare ACL-reconstructed knees to their contralateral knees at four distinct points during the stance phase of walking. An offset towards external tibial rotation in ACL-reconstructed knees was maintained over all time points (95%CI 2.3±1.3°). Twenty-two out of twenty-six individuals experienced an average external tibial rotation offset throughout stance phase. Varus–valgus rotation and knee flexion were not significantly different between reconstructed and contralateral knees. These findings show that differences in tibial rotation during walking exist in ACL reconstructed knees compared to healthy contralateral knees, providing a potential explanation why these patients are at higher risk of knee osteoarthritis in the long-term.  相似文献   

9.
Gastrocnemius is a premier muscle crossing the knee, but its role in knee biomechanics and on the anterior cruciate ligament (ACL) remains less clear when compared to hamstrings and quadriceps. The effect of changes in gastrocnemius force at late stance when it peaks on the knee joint response and ACL force was initially investigated using a lower extremity musculoskeletal model driven by gait kinematics—kinetics. The tibiofemoral joint under isolated isometric contraction of gastrocnemius was subsequently analyzed at different force levels and flexion angles (0°–90°). Changes in gastrocnemius force at late stance markedly influenced hamstrings forces. Gastrocnemius acted as ACL antagonist by substantially increasing its force. Simulations under isolated contraction of gastrocnemius confirmed this role at all flexion angles, in particular, at extreme knee flexion angles (0° and 90°). Constraint on varus/valgus rotations substantially decreased this effect. Although hamstrings and gastrocnemius are both knee joint flexors, they play opposite roles in respectively protecting or loading ACL. Although the quadriceps is also recognized as antagonist of ACL, at larger joint flexion and in contrast to quadriceps, activity in gastrocnemius substantially increased ACL forces (anteromedial bundle). The fact that gastrocnemius is an antagonist of ACL should help in effective prevention and management of ACL injuries.  相似文献   

10.
The knee joint is partially stabilized by the interaction of multiple ligament structures. This study tested the interdependent functions of the anterior cruciate ligament (ACL) and the medial collateral ligament (MCL) by evaluating the effects of ACL deficiency on local MCL strain while simultaneously measuring joint kinematics under specific loading scenarios. A structural testing machine applied anterior translation and valgus rotation (limits 100 N and 10 N m, respectively) to the tibia of ten human cadaveric knees with the ACL intact or severed. A three-dimensional motion analysis system measured joint kinematics and MCL tissue strain in 18 regions of the superficial MCL. ACL deficiency significantly increased MCL strains by 1.8% (p<0.05) during anterior translation, bringing ligament fibers to strain levels characteristic of microtrauma. In contrast, ACL transection had no effect on MCL strains during valgus rotation (increase of only 0.1%). Therefore, isolated valgus rotation in the ACL-deficient knee was nondetrimental to the MCL. The ACL was also found to promote internal tibial rotation during anterior translation, which in turn decreased strains near the femoral insertion of the MCL. These data advance the basic structure-function understanding of the MCL, and may benefit the treatment of ACL injuries by improving the knowledge of ACL function and clarifying motions that are potentially harmful to secondary stabilizers.  相似文献   

11.
A force balance between the ligaments, articular contact, muscles and body weight maintains knee joint stability. Thus, it is important to study anterior cruciate ligament (ACL) biomechanics, in vivo, under weightbearing conditions. Our objective was to compare the ACL strain response under weightbearing and non-weightbearing conditions and in combination with three externally applied loadings: (1) anterior-posterior shear forces, (2) internal-external torques, and (3) varus-valgus moments. A strain transducer was implanted on the ACL of 11 subjects. All joint loadings were performed with the knee at 20 degrees of flexion. A significant increase in ACL strain was observed as the knee made the transition from non-weightbearing to weightbearing. During anterior shear loading, the strain values produced during weightbearing were greater than those of the non-weightbearing knee (shear loads <40N). At higher shear loads, the strain values became equal. During axial torsion, an internal torque of 10Nm strained the ACL when the knee was non-weightbearing while an equivalent external torque did not. Weightbearing significantly increased ACL strain values in comparison to non-weightbearing with the application of external torques and low internal torques (<3Nm). The strains became equal for higher internal torques. For V-V loading, the ACL was not strained in the non-weightbearing knee. However, weightbearing increased the ACL strain values over the range of moments tested. These data have important clinical ramifications in the development of rehabilitation protocols following ACL reconstruction since weightbearing has been previously thought to provide a protective mechanism to the healing graft.  相似文献   

12.
This study determined which knee joint motions lead to anterior cruciate ligament (ACL) rupture with the knee at 25° of flexion. The knee was subjected to internal and external rotations, as well as varus and valgus motions. A failure locus representing the relationship between these motions and ACL rupture was established using finite element simulations. This study also considered possible concomitant injuries to the tibial articular cartilage prior to ACL injury. The posterolateral bundle of the ACL demonstrated higher rupture susceptibility than the anteromedial bundle. The average varus angular displacement required for ACL failure was 46.6% lower compared to the average valgus angular displacement. Femoral external rotation decreased the frontal plane angle required for ACL failure by 27.5% compared to internal rotation. Tibial articular cartilage damage initiated prior to ACL failure in all valgus simulations. The results from this investigation agreed well with other experimental and analytical investigations. This study provides a greater understanding of the various knee joint motion combinations leading to ACL injury and articular cartilage damage.  相似文献   

13.
Comparison of kinematics in the healthy and ACL injured knee using MRI   总被引:3,自引:0,他引:3  
Magnetic Resonance Imaging (MRI) was used to examine the characteristics of abnormal motion in the injured knee by mapping tibiofemoral contact. Eleven healthy subjects and 20 subjects with a unilateral ACL injury performed a leg-press against resistance. MRI scans of both knees at 15 degrees intervals from 0 degrees to 90 degrees of flexion were used to record the tibiofemoral contact pattern. The tibiofemoral contact pattern of the injured knees was more posterior on the tibial plateau than the healthy knees, particularly in the lateral compartment. The tibiofemoral contact pattern of the loaded knees did not differ from the unloaded knees. The difference in the tibiofemoral contact pattern in the ACL injured knee was associated with more severe knee symptoms, irrespective of the passive anterior laxity of the knee.  相似文献   

14.
The purpose of this study was to determine the effect of a weight-bearing free weight resistance training program alone on knee flexion, hip flexion, and knee valgus during unilateral and bilateral drop jump tasks. Twenty-nine young adult females with previous athletic experience were randomly divided into a control (n = 16) and a resistance training (n = 13) groups. The resistance training group completed 8 weeks of lower extremity, weight-bearing exercises using free weights, whereas the control group did not train. A pre- and posttest was conducted to measure knee valgus, knee flexion, and hip flexion during unilateral (30 cm) and bilateral (60 cm) vertical drop jumps for maximum height. Joint angles were determined using 3-dimensional electromagnetic tracking sensors (MotionMonitor; Innovative Sports Training, Inc., Chicago, IL, USA). Initial training intensity for the bilateral squat was 50% of the subject's 1 repetition maximum (RM), which increased 5% each week to 85% during the final week. Sets and repetitions ranged from 2 to 4 and from 4 to 12, respectively. The training loads for all other exercises (lunge, step-up, unilateral squat, and Romanian deadlift) increased from 15RM to 6RM from the initial to the final week. A repeated measures analysis of variance was used to determine differences in the hip and knee joint angles. No significant differences for knee valgus and hip flexion measures were found between the groups after training; however, knee flexion angle significantly increased in the training group from the pretest (77.2 ± 4.1°) to posttest (83.2 ± 3.7°) during the bilateral drop jump. No significant changes occurred during the unilateral drop jump. Bilateral measures for knee flexion, hip flexion, and knee valgus were significantly (p < 0.05) greater than the unilateral measures during the drop jump task, which indicate an increased risk for anterior cruciate ligament (ACL) injury during unilateral drop jumps. The data support that the strength and conditioning specialist can implement resistance training alone during a short-term training period to reduce the risk of ACL injury by increasing knee flexion during a bilateral drop jump task. Increased knee flexion angles after resistance training may indicate a reduced risk for knee injury from improved neuromuscular control, resulting in a softer landing.  相似文献   

15.
Accurate knowledge of in vivo anterior cruciate ligament (ACL) forces is instrumental for understanding normal ACL function and improving surgical ACL reconstruction techniques. The objective of this study was to estimate the change in ACL forces under in vivo loading conditions using a noninvasive technique. A combination of magnetic resonance and dual fluoroscopic imaging system was used to determine ACL in vivo elongation during controlled weightbearing at discrete flexion angles, and a robotic testing system was utilized to determine the ACL force-elongation data in vitro. The in vivo ACL elongation data were mapped to the in vitro ACL force-elongation curve to estimate the change in in vivo ACL forces in response to full body weightbearing using a weighted mean statistical method. The data demonstrated that by assuming that there was no tension in the ACL under zero weightbearing, the changes in in vivo ACL force caused by full body weightbearing were 131.4 ± 16.8 N at 15 deg, 106.7 ± 11.2 N at 30 deg, and 34.6 ± 4.5 N at 45 deg of flexion. However, when the assumed tension in the ACL under zero weightbearing was over 20 N, the change in the estimated ACL force in response to the full body weightbearing approached an asymptotic value. With an assumed ACL tension of 40 N under zero weightbearing, the full body weight caused an ACL force increase in 202.7 ± 27.6 N at 15 deg, 184.9 ± 22.5 N at 30 deg, and 98.6 ± 11.7 N at 45 deg of flexion. The in vivo ACL forces were dependent on the flexion angle with higher force changes at low flexion angles. Under full body weightbearing, the ACL may experience less than 250 N. These data may provide a valuable insight into the biomechanical behavior of the ACL under in vivo loading conditions.  相似文献   

16.
Previous studies of biomechanical properties of femur-anterior cruciate ligament-tibia complex (FATC) utilized a wide variety of testing methodologies, particularly with respect to ligament orientation relative to loading direction. A new device was designed and built to test the anterior-posterior displacement of the intact porcine knee at 30 and 90 deg of flexion, as well as the tensile properties of the FATC at any loading direction and flexion angle. Tensile tests were performed with the knees at 30 and 90 deg of flexion with the loading direction along either the axis of the tibia (tibial axis) or the axis of the anterior cruciate ligament (ligament axis). The results showed that the stiffness, ultimate load and energy absorbed were all significantly increased when the FATC was tested along the ligament axis. This study demonstrates the importance of alignment in the evaluation of the biomechanical characteristics of the femur-ACL-tibia complex.  相似文献   

17.
Lengthening of an anterior cruciate ligament (ACL) graft construct can occur as a result of lengthening at the sites of tibial and/or femoral fixation and manifests as an increase in anterior laxity. Although lengthening at the site of fixation has been measured for a variety of fixation devices, it is difficult to place these results in a clinical context because the mathematical relationship between lengthening of an ACL graft construct and anterior laxity is unknown. The purpose of our study was to determine empirically this relationship. Ten cadaveric knees were reconstructed with a double-looped tendon graft. With the knee in 25 degrees of flexion, the position of the proximal end of the graft inside the femoral tunnel was adjusted by moving the femoral fixation device until the anterior laxity at an applied anterior force of 134 N matched that of the intact knee. In random order, the graft construct was lengthened 1, 2, 3, 4, and 5 mm by moving the femoral fixation device distally along the femoral tunnel and anterior laxity was measured. The increase in the length of the graft construct was related to the increase in anterior laxity by a simple linear regression model. Lengthening the graft construct from 1 to 5 mm caused an equal increase in anterior laxity (slope=1.0 mmmm, r(2)=0.800, p<0.0001). Because an anterior laxity increase of 3 mm or greater in a reconstructed knee is considered unstable clinically and because many fixation devices in widespread use clinically allow 3 mm or greater of lengthening in in vitro tests, our empirical relationship indicates that lengthening at the site of fixation probably is an important cause of knee instability following ACL reconstructive surgery. Our empirical relation also indicates that an important criterion in the design of future fixation devices is that lengthening at the sites of fixation in in vitro tests should be limited to less than 3 mm.  相似文献   

18.
A potential cause of non-contact anterior cruciate ligament (ACL) injury is landing on an extended knee. In line with this hypothesis, studies have shown that the ACL is elongated with decreasing knee flexion angle. Furthermore, at low flexion angles the patellar tendon is oriented to increase the anterior shear component of force acting on the tibia. This indicates that knee extension represents a position in which the ACL is taut, and thus may have an increased propensity for injury, particularly in the presence of excessive force acting via the patellar tendon. However, there is very little in vivo data to describe how patellar tendon orientation and ACL elongation interact during flexion. Therefore, this study measured the patellar tendon tibial shaft angle (indicative of the relative magnitude of the shear component of force acting via the patellar tendon) and ACL length in vivo as subjects performed a quasi-static lunge at varying knee flexion angles. Spearman rho rank correlations within each individual revealed that flexion angles were inversely correlated to both ACL length (rho = −0.94 ± 0.07, mean ± standard deviation, p < 0.05) and patellar tendon tibial shaft angle (rho = −0.99 ± 0.01, p < 0.05). These findings indicate that when the knee is extended, the ACL is both elongated and the patellar tendon tibial shaft angle is increased, resulting in a relative increase in anterior shear force on the tibia acting via the patellar tendon. Therefore, these data support the hypothesis that landing with the knee in extension is a high risk scenario for ACL injury.  相似文献   

19.
Knee hyperextension has been described as a mechanism of isolated anterior cruciate ligament (ACL) tears, but clinical and experimental studies have produced contradictory results for the ligament injuries and the injury sequence caused by the hyperextension loading mechanism. The hypothesis of this study was that bicruciate ligament injuries would occur as a result of knee hyperextension by producing high tibio-femoral (TF) compressive forces that would cause anterior translation of the tibia to rupture the ACL, while joint extension would simultaneously induce rupture of the posterior cruciate ligament (PCL). Six human knees were loaded in hyperextension until gross injury, while bending moments and motions were recorded. Pressure sensitive film documented the magnitude and location of TF compressive forces. The peak bending moment at failure was 108?N?m±46?N?m at a total extension angle of 33.6?deg±11?deg. All joints failed by simultaneous ACL and PCL damages at the time of a sudden drop in the bending moment. High compressive forces were measured in the anterior compartments of the knee and likely produced the anterior tibial subluxation, which contributed to excessive tension in the ACL. The injury to the PCL at the same time may have been due to excessive extension of the joint. These data, and the comparisons with previous experimental studies, may help explain the mechanisms of knee ligament injury during hyperextension. Knowledge of forces and constraints that occur clinically could then help diagnose primary and secondary joint injuries following hyperextension of the human knee.  相似文献   

20.
The hamstring muscles have been recognized as an important element in compensating for the loss of stability in the ACL-deficient knee, but it is still not clear whether the hamstring muscle force can completely compensate for the loss of ACL, and the consequences of increased hamstring muscle force. A two-dimensional anatomical knee model in the sagittal plane was developed to examine the effect of various levels of hamstring muscle activation on restraining anterior tibial translation in the ACL-deficient knee during level walking. The model included the tibiofemoral and patellofemoral joints, four major ligaments, the medial capsule, and five muscle units surrounding the knee. Simulations were conducted to determine anterior tibial translation and internal joint loading at a single selected position when the knee was under a peak external flexion moment during early stance phase of gait. Incremental hamstring muscle forces were applied to the modeled normal and the ACL-deficient knees. Results of simulations showed that the ACL injury increased the anterior tibial translation by 11.8mm, while 56% of the maximal hamstring muscle force could reduce the anterior translation of the tibia to a normal level during the stance phase of gait. The consequences of increased hamstring muscle force included increased quadriceps muscle force and joint contact force.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号