首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
2.
Recent numerical studies of abdominal aortic aneurysm (AAA) suggest that intraluminal thrombus (ILT) may reduce the stress loading on the aneurysmal wall. Detailed fluid structure interaction (FSI) in the presence and absence of ILT may help predict AAA rupture risk better. Two patients, with varied AAA geometries and ILT structures, were studied and compared in detail. The patient specific 3D geometries were reconstructed from CT scans, and uncoupled FSI approach was applied. Complex flow trajectories within the AAA lumen indicated a viable mechanism for the formation and growth of the ILT. The resulting magnitude and location of the peak wall stresses was dependent on the shape of the AAA, and the ILT appeared to reduce wall stresses for both patients. Accordingly, the inclusion of ILT in stress analysis of AAA is of importance and would likely increase the accuracy of predicting AAA risk of rupture.  相似文献   

3.
Recent numerical studies of abdominal aortic aneurysm (AAA) suggest that intraluminal thrombus (ILT) may reduce the stress loading on the aneurysmal wall. Detailed fluid structure interaction (FSI) in the presence and absence of ILT may help predict AAA rupture risk better. Two patients, with varied AAA geometries and ILT structures, were studied and compared in detail. The patient specific 3D geometries were reconstructed from CT scans, and uncoupled FSI approach was applied. Complex flow trajectories within the AAA lumen indicated a viable mechanism for the formation and growth of the ILT. The resulting magnitude and location of the peak wall stresses was dependent on the shape of the AAA, and the ILT appeared to reduce wall stresses for both patients. Accordingly, the inclusion of ILT in stress analysis of AAA is of importance and would likely increase the accuracy of predicting AAA risk of rupture.  相似文献   

4.
Abdominal aortic aneurysm (AAA) is the gradual weakening and dilation of the infrarenal aorta. This disease is progressive, asymptomatic, and can eventually lead to rupture--a catastrophic event leading to massive internal bleeding and possibly death. The mechanical environment present in AAA is currently thought to be important in disease initiation, progression, and diagnosis. In this study, we utilize porohyperelastic (PHE) finite element models (FEMs) to investigate how such modeling can be used to better understand the local biomechanical environment in AAA. A 3D hypothetical AAA was constructed with a preferential anterior bulge assuming both the intraluminal thrombus (ILT) and the AAA wall act as porous materials. A parametric study was performed to investigate how physiologically meaningful variations in AAA wall and ILT hydraulic permeabilities affect luminal interstitial fluid velocities and wall stresses within an AAA. A corresponding hyperelastic (HE) simulation was also run in order to be able to compare stress values between PHE and HE simulations. The effect of AAA size on local interstitial fluid velocity was also investigated by simulating maximum diameters (5.5 cm, 4.5 cm, and 3.5 cm) at the baseline values of ILT and AAA wall permeability. Finally, a cyclic PHE simulation was utilized to study the variation in local fluid velocities as a result of a physiologic pulsatile blood pressure. While the ILT hydraulic permeability was found to have minimal affect on interstitial velocities, our simulations demonstrated a 28% increase and a 20% decrease in luminal interstitial fluid velocity as a result of a 1 standard deviation increase and decrease in AAA wall hydraulic permeability, respectively. Peak interstitial velocities in all simulations occurred on the luminal surface adjacent to the region of maximum diameter. These values increased with increasing AAA size. PHE simulations resulted in 19.4%, 40.1%, and 81.0% increases in peak maximum principal wall stresses in comparison to HE simulations for maximum diameters of 35 mm, 45 mm, and 55 mm, respectively. The pulsatile AAA PHE FEM demonstrated a complex interstitial fluid velocity field the direction of which alternated in to and out of the luminal layer of the ILT. The biomechanical environment within both the aneurysmal wall and the ILT is involved in AAA pathogenesis and rupture. Assuming these tissues to be porohyperelastic materials may provide additional insight into the complex solid and fluid forces acting on the cells responsible for aneurysmal remodeling and weakening.  相似文献   

5.
The intraluminal thrombus (ILT) commonly found within abdominal aortic aneurysm (AAA) may serve as a barrier to oxygen diffusion from the lumen to the inner layers of the aortic wall. The purpose of this work was to address this hypothesis and to assess the effects of AAA bulge diameter (dAAA) and ILT thickness (delta) on the oxygen flow. A hypothetical, three-dimensional, axisymmetric model of AAA containing ILT was created for computational analysis. Commercial software was utilized to estimate the volume flow of O2 per cell, which resulted in zero oxygen tension at the AAA wall. Solutions were generated by holding one of the two parameters fixed while varying the other. The supply of O2 to the AAA wall increases slightly and linearly with dAAA for a fixed delta. This slight increase is due to the enlarged area through which diffusion of O2 may take place. The supply of O2 was found to decrease quickly with increasing delta for a fixed dAAA due to the increased resistance to O2 transport by the ILT layer. The presence of even a thin, 3 mm ILT layer causes a diminished O2 supply (less than 4 x 10(-10) mumol/min/cell). Normally functioning smooth muscle cells require a supply of 21 x 10(-10) mumol/min/cell. Thus, our analysis serves to support our hypothesis that the presence of ILT alters the normal pattern of O2 supply to the AAA wall. This may lead to hypoxic cell dysfunction in the AAA wall, which may further lead to wall weakening and increased potential for rupture.  相似文献   

6.
BackgroundIntraluminal thrombus (ILT) formation plays a significant role in the progression of infrarenal abdominal aortic aneurysms (AAA). Potentially, as ILT thickness increases the availability of trace elements in the aneurysm wall could decrease thereby leading to oxidative stress and intensifying pro-inflammatory cytokine generation.AimTo determine if thrombus thickness is related to the concentration of trace elements in the wall of infrarenal AAA.Patients and methodsThe concentrations of trace elements in the wall of the aneurysm sack and ILT obtained from 19 consecutive patients during surgery for infrarenal AAA were determined using emission spectrometry.ResultsThe concentrations of magnesium, zinc, manganese, and lead in the wall of AAA were significantly greater than in the ILT. Only the concentration of copper was lower in the AAA wall compared with the thrombus. The concentration of calcium, phosphorus, zinc, lead, copper, and magnesium increased with ILT thickness. The concentrations of no other trace elements in the wall of AAA were found to be related to the ILT thickness.ConclusionsIntraluminal thrombus thickness is not associated with a lower concentration of trace elements in the wall of the infrarenal AAA. Thus, the intraluminal thrombus participates in the progression of AAA by mechanisms independent of trace element supply to the wall of the aneurysm sack.  相似文献   

7.
Accurate estimation of the wall stress distribution in an abdominal aortic aneurysm (AAA) may prove clinically useful by predicting when a particular aneurysm will rupture. Appropriate constitutive models for both the wall and the intraluminal thrombus (ILT) found in most AAA are necessary for this task. The purpose of this work was to determine the mechanical properties of ILT within AAA and to derive a more suitable constitutive model for this material. Uniaxial tensile testing was carried out on 50 specimens, including 14 longitudinally oriented and 14 circumferentially oriented specimens from the luminal region of the ILT, and 11 longitudinally oriented and 11 circumferentially oriented specimens from the medial region. A two-parameter, large-strain, hyperelastic constitutive model was developed and used to fit the uniaxial tensile testing data for determination of the material parameters. Maximum stiffness and strength were also determined from the data for each specimen. Scanning electron microscopy (SEM) was conducted to study the regional microstructural difference. Our results indicate that the microstructure of ILT differs between the luminal, medial, and abluminal regions, with the luminal region stronger and stiffer than the medial region. In all cases, the constitutive model fit the experimental data very well (R2>0.98). No significant difference was found for either of the two material parameters between longitudinal and circumferential directions, but a significant difference in material parameters, stiffness, and strength between the laminal and medial regions was determined (p<0.01). Therefore, our results suggest that ILT is an inhomogeneous and possibly isotropic material. The two-parameter, hyperelastic, isotropic, incompressible material model derived here for ILT can be easily incorporated into finite element models for simulation of wall stress distribution in AAA.  相似文献   

8.

Introduction

Thrombus ages, defined as four relative age phases, are related to different compositions of the intraluminal thrombus (ILT) in the abdominal aortic aneurysm (AAA) (Tong et al., 2011b). Experimental studies indicate a correlation between the relative thrombus age and the strength of the thrombus-covered wall.

Methods

On 32 AAA samples we performed peeling tests with the aim to dissect the material (i) through the ILT thickness, (ii) within the individual ILT layers and (iii) within the aneurysm wall underneath the thrombus by using two extension rates (1 mm/min, 1 mm/s). Histological investigations and mass fraction analysis were performed to characterize the dissected morphology, to determine the relative thrombus age, and to quantify dry weight percentages of elastin and collagen in the AAA wall.

Results

A remarkably lower dissection energy was needed to dissect within the individual ILT layers and through the thicknesses of old thrombi. With increasing ILT age the dissection energy of the underlying intima–media composite continuously decreased and the anisotropic dissection properties for that composite vanished. The quantified dissection properties were rate dependent for both tissue types (ILT and wall). Histology showed that single fibrin fibers or smaller protein clots within the ILT generate smooth dissected surfaces during the peeling. There was a notable decrease in mass fraction of elastin within the thrombus-covered intima–media composite with ILT age, whereas no significant change was found for that of collagen.

Conclusions

These findings suggest that intraluminal thrombus aging leads to a higher propensity of dissection for the ILT and the intima–media composite of the aneurysmal wall.  相似文献   

9.
Self-healing phenomenon was found in the periarterial elastase-induced abdominal aortic aneurysm (AAA) in rabbit. This kind of aneurysm model does not progress and heals spontaneously in the long term, which is quite different from the performance of AAA disease in human. In order to better mimic human AAA and overcome this shortcoming of traditional AAA model in rabbit, we studied the pathogenesis of cerebral aneurysm (CA) model in small animal, which shows an excellent long-term patency and progressive enlargement. We found that hemodynamic conditions, such as turbulence flow, high blood flow, and shear stress, play an important role in the formation and progression of CA. So, we hypothesize that hemodynamic change may also play an essential role in the initiation and progression of rabbit AAA, and self-healing will be overcome if hemodynamic condition changes by coarctation of infra-renal aorta after elastase incubation.  相似文献   

10.
Wang X  Li X 《Journal of biomechanics》2011,44(12):2177-2184
Endovascular aneurysm repair (EVAR) is considered as a promising alternative technique for the treatment of aortic aneurysm. However, complications often occur after EVAR. In this paper, the influence of the physiological factors on the biomechanical behaviors of stented and non-stented thoracic aortic aneurysm (TAA) were presented. Representative TAA models with different intraluminal thrombus (ILT) volume before and after stent-graft (SG) implantation were built. Fluid-structure interaction effect was taken into account. The relative sliding between the SG wall and the aortic wall was allowed. Results showed that the cardiac cycle and ILT volume should be given much more consideration than previously thought in future investigations on TAA compliance. The time-averaged longitudinal displacement of SG necks were not uniformly distributed along circumferential direction of the aortic wall. Drag force increased with the increase of the cardiac cycle and decreased with the decrease of ILT volume. Computational results of TAA wall stress, sac and lumen pressure indicated that patient with faster heart rate might be at great risk of aneurysm rupture. The stress absorption effect of the SG was influenced by both ILT and cardiac cycle, which was also found to have strong impact on flow pattern. We believe that this study will bring new insights into further researches on the relevant issues and provide mechanics-based implications for clinical management of EVAR for TAA patient.  相似文献   

11.
Pulsatile flow in an axisymmetric rigid-walled model of an abdominal aorta aneurysm was analyzed numerically for various aneurysm dilations using physiologically realistic resting waveform at time-averaged Reynolds number of 300 and peak Reynolds number of 1607. Discretization of the governing equations was achieved using a finite element scheme based on the Galerkin method of weighted residuals. Comparisons with previously published work on the basis of special cases were performed and found to be in excellent agreement. Our findings indicate that the velocity fields are significantly affected by non-Newtonian properties in pathologically altered configurations. Non-Newtonian fluid shear stress is found to be greater than Newtonian fluid shear stress during peak systole. Further, the maximum shear stress is found to occur near the distal end of AAA during peak systole. The impact of non-Newtonian blood flow characteristics on pressure compared to Newtonian model is found insignificant under resting conditions. Viscous and inertial forces associated with blood flow are responsible for the changes in the wall that result in thrombus deposition and dilation while rupture of AAA is more likely determined by much larger mechanical stresses imposed by pulsatile pressure on the wall of AAA.  相似文献   

12.
Abdominal aortic aneurysm (AAA) is perma-nent and localized dilation of the abdominal aorta. Intraluminal thrombus (ILT) is involved in evolution and rupture of AAA. Complex biological processes associated with AAA include oxidative stress, proteolysis, neovascularization, aortic inflammation, cell death, and extracellular matrix breakdown. Biomarkers of growth and AAA rupture could give a more nuanced indication for surgery, unveil novel pathogenic pathways, and open possibilities for pharmacological inhibition of growth. Differential analysis of metabolites released by normal and pathological arteries in culture may help to find molecules that have a high probability of later being found in plasma and start signaling processes or be useful diagnostic/prognostic markers. We used a LC-QTOF-MS metabolomic approach to analyze metabolites released by human ILT (divided into luminal and abluminal layers), aneurysm wall (AW), and healthy wall (HW). Statistical analysis was used to compare luminal with abluminal ILT layer, ILT with AW, and AW with HW to select the metabolites exchanged between tissue and external medium. Identified compounds are related to inflammation and oxidative stress and indicate the possible role of fatty acid amides in AAA. Some metabolites (e.g., hippuric acid) had not been previously associated to aneurysm, others (fatty acid amides) have arisen, indicating a very promising line of research.  相似文献   

13.
An experimental study was carried out on asymmetrical abdominal aortic aneurysm (AAA) to analyse the physiological flows involved. Velocity measurements were performed using particle image velocimetry. Resting and exercise flow rates were investigated in models with rigid and compliant walls to assess the parameters affecting the flow behaviour. The secondary flow patterns, and especially the evolution of the vortices within the AAA, were found to be highly dependent on both the flow waveforms and the wall behaviour. Vortices impacts on the distal walls of the AAA occur in the compliant model and can increase the local pressure on the AAA walls and thus increase the wall stresses; AAA wall stresses are one of the most important factors contributing to ruptured aneurysm.  相似文献   

14.
Focusing on a representative abdominal aortic aneurysm (AAA) with a bifurcating stent-graft (SG), a fluid-structure interaction (FSI) solver with user-supplied programs has been employed to solve for blood flow, AAA/SG deformation, sac pressure and wall stresses, as well as the downward forces acting on the SG. Simulation results indicate that implanting a SG can significantly reduce sac pressure, mechanical stress, pulsatile wall motion, and maximum diameter change in AAAs; hence, it may restore normal blood flow and prevent AAA rupture effectively. The transient SG drag force is similar in trend as the cardiac pressure. Its magnitude depends on multi-factors including blood flow conditions, as well as SG and aneurysm geometries. Specifically, AAA neck angle, iliac bifurcation angle, neck aorta-to-iliac diameter ratio, SG size, and blood waveform play important roles in generating a fluid flow force potentially leading to SG migration. It was found that the drag force can exceed 5N for an AAA with a large neck or iliac angle, wide aortic neck and narrow iliac arteries, large SG size, and/or abnormal blood waveform. Thus, the fixation of self-expandable or balloon-expandable SG contact may be inadequate to withstand the forces of blood flowing through the implant and hence means of extra fixation should be considered. A comprehensive FSI analysis of the coupled SG-AAA dynamics provides physical insight for evaluating the luminal hemodynamics, and maximum AAA-stresses as well as biomechanical factors leading potentially to SG migration.  相似文献   

15.
Biomechanics and Modeling in Mechanobiology - In this study, the biomechanical role of intraluminal thrombus (ILT) in an abdominal aortic aneurysm (AAA) is investigated. The implications of ILT in...  相似文献   

16.
A new experimental setup has been implemented to precisely measure the deformations of an entire model abdominal aortic aneurysm (AAA). This setup addresses a gap between the computational and experimental models of AAA that have aimed at improving the limited understanding of aneurysm development and rupture. The experimental validation of the deformations from computational approaches has been limited by a lack of consideration of the large and varied deformations that AAAs undergo in response to physiologic flow and pressure. To address the issue of experimentally validating these calculated deformations, a stereoscopic imaging system utilizing two cameras was constructed to measure model aneurysm displacement in response to pressurization. The three model shapes, consisting of a healthy aorta, an AAA with bifurcation, and an AAA without bifurcation, were also evaluated with computational solid mechanical modeling using finite elements to assess the impact of differences between material properties and for comparison against the experimental inflations. The device demonstrated adequate accuracy (surface points were located to within 0.07?mm) for capturing local variation while allowing the full length of the aneurysm sac to be observed at once. The experimental model AAA demonstrated realistic aneurysm behavior by having cyclic strains consistent with reported clinical observations between pressures 80 and 120?mm Hg. These strains are 1-2%, and the local spatial variations in experimental strain were less than predicted by the computational models. The three different models demonstrated that the asymmetric bifurcation creates displacement differences but not cyclic strain differences within the aneurysm sac. The technique and device captured regional variations of strain that are unobservable with diameter measures alone. It also allowed the calculation of local strain and removed rigid body motion effects on the strain calculation. The results of the computations show that an asymmetric aortic bifurcation created displacement differences but not cyclic strain differences within the aneurysm sac.  相似文献   

17.
The aim of this work is to develop a unique in vitro set-up in order to analyse the influence of the shear thinning fluid-properties on the flow dynamics within the bulge of an abdominal aortic aneurysm (AAA). From an experimental point of view, the goals are to elaborate an analogue shear thinning fluid mimicking the macroscopic blood behaviour, to characterise its rheology at low shear rates and to propose an experimental device able to manage such an analogue fluid without altering its feature while reproducing physiological flow rate and pressure, through compliant AAA. Once these experimental prerequisites achieved, the results obtained in the present work show that the flow dynamics is highly dependent on the fluid rheology. The main results point out that the propagation of the vortex ring, generated in the AAA bulge, is slower for shear thinning fluids inducing a smaller travelled distance by the vortex ring so that it never impacts the anterior wall in the distal region, in opposition to Newtonian fluids. Moreover, scalar shear rate values are globally lower for shear thinning fluids inducing higher maximum stress values than those for the Newtonian fluids. Consequently, this work highlights that a Newtonian fluid model is finally inadequate to obtain a reliable prediction of the flow dynamics within AAA.  相似文献   

18.
In this paper, we review existing clinical research data on post-endovascular repair (EVAR) intrasac pressure and relation with abdominal aortic aneurysm (AAA) size changes. Based on the review, we hypothesize that intrasac pressure has a significant impact on post-EVAR AAA size changes, and post-EVAR remodeling depends also on how the pressure has changed over a period of time. The previously developed model of an AAA based on a constrained mixture approach is extended to include vascular adaptation after EVAR using an idealized geometry. Computational simulation shows that the same mechanism of collagen stress-mediated remodeling in AAA expansion induces the aneurysm wall to shrink in a reduced sac-pressure after post-EVAR. Computational simulation suggests that the intrasac pressure of 60 mm?Hg is a critical value. At this value, the AAA remains stable, while values above cause the AAA to expand and values below cause the AAA to shrink. There are, however, variations between individuals due to different cellular sensitivities in stress-mediated adaptation. Computer simulation also indicates that an initial decrease in intrasac pressure helps the AAA shrink even if the pressure increases after some time. The presented study suggests that biomechanics has a major effect on initial adaptation after EVAR and also illustrates the utility of a computational model of vascular growth and remodeling in predicting diameter changes during the progression and after the treatment of AAAs.  相似文献   

19.
Insertion of a stent-graft into an aneurysm, especially abdominal aortic aneurysms (AAAs), is a very attractive surgical intervention; however, it is not without major postoperative complications, such as endoleaks. An endoleak is the transient accumulation of blood in the AAA cavity, which is formed by the stent-graft and AAA walls. Of the four blood pathways, a type I endoleak constitutes the major one. Thus, focusing on both proximal and distal type I endoleaks, i.e., the minute net influx of blood past the attachment points of a stent-graft into the AAA cavity, the transient three-dimensional interactions between luminal blood flow stent-graft wall, leakage flow, and AAA wall are computationally simulated. For different type I endoleak scenarios and inlet pressure wave forms, the impact of type I endoleaks on cavity pressure, wall stress, and stent-graft migration force is analyzed. The results indicate that both proximal type I-a and distal type I-b endoleaks may cause cavity pressures close to a patient's systemic pressure; however, with reduced pulsatility. As a result, the AAA-wall stress is elevated up to the level of a nonstented AAA and, hence, such endoleaks render the implant useless in protecting the AAA from possible rupture. Interestingly enough, the net downward force acting on the implant is significantly reduced; thus, in the presence of endoleaks, the risk of stent-graft migration may be mitigated.  相似文献   

20.
Numerical prediction of non-Newtonian blood flow in a 3D abdominal aortic aneurysm bifurcating model is carried out. The non-Newtonian Carreau model is used to characterise the shear thinning behaviour of the human blood. A physical inlet velocity waveform incorporating a radial velocity distribution reasonably representative of a practical case configuration is employed. Case studies subject to both equal and unequal outlet pressures at iliac bifurcations are presented to display convincingly the downstream pressure influences on the flow behaviour within the aneurysm. Simulations indicate that the non-Newtonian aspects of the blood cannot at all be neglected or given a cursory treatment. The wall shear stress (WSS) is found to change significantly at both the proximal and distal ends of the aneurysm. At the peak systole, the WSS is peak around the bifurcation point, whereas the WSS becomes zero in the bifurcation point. Differential downstream pressure fields display significant effects regarding the flow evolution in the iliac arteries, whereas little or no effects are observed directly on the flow details in the aneurysm.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号