首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
A large majority of surface plasmon resonance (SPR) sensors reported in the literature are designed to operate in the visible electromagnetic spectrum. However, the near-infrared, particularly at the telecommunications wavelength of 1550 nm, is also especially attractive for SPR sensing applications. In fact, SPR sensors operating in this region benefit from narrower resonance and deeper field penetration. In this paper, we report a theoretical and experimental study of an SPR sensor operating at a fixed wavelength of 1550 nm. The influence of the choice of metals and the interrogation methods on the sensitivity of the resulting SPR sensor is investigated. Two types of sensor chips (simple gold (Au) and bimetallic silver/Au structure) and three interrogation methods (monitoring of the position of the reflectivity minimum, the position of the centroid, and the intensity evolution of the reflectivity) are examined. We show that a refractive index resolution of 2.7?×?10?6 refractive index unit can be easily obtained, and with further optimization of the measurement system, the ultimate limit of detection is expected to be even lowered. Therefore, the approach discussed here already shows a promising potential for highly sensitive SPR sensors.  相似文献   

2.
Surface plasmon resonance (SPR) has become one of the most important techniques for studying macromolecular interactions. The most obvious advantages of SPR over other techniques are: direct and rapid determination of association and dissociation rates of binding process, no need for labelling of protein or lipids, and small amounts of sample used in the assay (often nM concentrations of proteins). In biochemistry, SPR is used mainly to study protein-protein interactions. On the other hand, protein-membrane interactions, although crucial for many cell processes, are less well studied. Recent advances in the preparation of stable membrane-like surfaces and the commercialisation of sensor chips has enabled widespread use of SPR in protein-membrane interactions. One of the most popular is Biacore's L1 sensor chip that allows capture of intact liposomes or even subcellular preparations. Lipid specificity of protein-membrane interactions can, therefore, be easily studied by manipulating the lipid composition of the immobilised membrane. The number of published papers has increased steadily in the last few years and the examples include domains or proteins that participate in cell signalling, pore-forming proteins, membrane-interacting peptides, coagulation factors, enzymes, amyloidogenic proteins, prions, etc. This paper gives a brief overview of different membrane-mimetic surfaces that can be prepared on the surface of SPR chips, properties of liposomes on the surface of L1 chips and some selected examples of protein-membrane interactions studied with such system.  相似文献   

3.
五种SPR传感芯片的再生制备及其应用   总被引:3,自引:0,他引:3  
基于表面等离子体共振技术(surface plasmon resonance, SPR)的生物传感器,能够实时监测生物分子间的相互作用,且无需标记,已被广泛应用于蛋白质组学、药物研发、临床诊断、食品安全和环境监测等领域,并且显示出广阔的应用前景。传感芯片是Biacore系列仪器的核心部件,目前芯片只能从Biacore公司购买,价格昂贵,导致很多仪器利用率低下,资源处于闲置状态。阐述了用于Biacore系列仪器的五种传感芯片(J1,C1,CM5,SA和NTA芯片)的再生制备方法,并列举了应用实例,制备方法操作简单,成本低廉。通过多年的改进与优化,制备的芯片能够达到Biacore芯片同等品质。此方法的推广,将有助于推动表面等离子共振技术在各个领域的广泛应用。  相似文献   

4.
Surface plasmon resonance (SPR) biosensors offer the capability for continuous real-time monitoring. The commercial instruments available have been large in size, expensive, and not amenable to field applications. We report here an SPR sensor system based on a prototype two-channel system similar to the single channel Spreeta devices. This system is an ideal candidate for field use. The two-channel design provides a reference channel to compensate for bulk refractive index (RI), non-specific binding and temperature variations. The SPR software includes a calibration function that normalizes the response from both channels, thus enabling accurate referencing. In addition, a temperature-controlled enclosure utilizing a thermo-electric module based on the Peltier effect provides the temperature stability necessary for accurate measurements of RI. The complete SPR sensor system can be powered by a 12V battery. Pre-functionalized, disposable, gold-coated thin glass slides provide easily renewable sensor elements for the system. Staphylococcus aureus enterotoxin B (SEB), a small protein toxin was directly detectable at sub-nanomolar levels and with amplification at femtomolar levels. A regeneration procedure for the sensor surface allowed for over 60 direct detection cycles in a 1-month period.  相似文献   

5.
Surface plasmon resonance (SPR) spectroscopy has been used to study DNA assembly, DNA hybridization, and protein-DNA interactions on two streptavidin (SA) sensor chips. On one chip, SA molecules are immobilized on a biotin-exposed surface, forming an ordered two-dimensional (2D) SA monolayer. The other chip, BIAcore's SA chip, contains SA molecules immobilized within a three-dimensional (3D) carboxylated dextran matrix. Compared to the 2D chip, the 3D SA matrix allows for a slower immobilization rate of biotinylated DNA due to diffusion limitation in the dextran matrix, but with twice the amount of the immobilized DNA due to the greater number of reactive sites, which in turn enables a higher sensitivity for DNA hybridization detection. Interestingly, having a greater DNA probe dispersion in the 3D matrix does not induce a higher DNA hybridization efficiency. In a study of protein binding to immobilized DNA (estrogen receptor to estrogen response elements), aiming at assessing the DNA sequence dependent protein binding behavior, the 2D and 3D chips produce different binding characteristics. On the 2D chip, the protein binding exhibits a better selectivity to the specific sequences, regardless of binding stringency (e.g. salt concentration), whereas on the 3D chip, the liquid handling system needs to be optimized in order to minimize transport limitations and to detect small affinity differences. Through this study we demonstrate that the physicochemical structure of SPR chips affects the apparent binding behaviors of biomolecules. When interpreting SPR binding curves and selecting a sensor chip, these effects should be taken into account.  相似文献   

6.
As the potential for bioterrorism has appeared to increase, the need for simple systems for identifying potential inhibitors of the binding of such biological agents to cell membranes has increased. In this work, surface plasmon resonance (SPR) was used to monitor binding of ricin, a ribosome-inactivating protein, to the plasma membranes of NIH 3T3 cells. Once conditions were established, efficacy of the system for monitoring effectiveness of compounds at inhibiting ricin binding was ascertained by determining the IC50 values for asialofetuin (ASF) and for bovine serum albumin derivatized with an average of 34 lactosyl moieties (BSA-Lac34). Results indicated that SPR is an efficient method for measuring adherence of a toxin to isolated cell plasma membranes. SPR can also indicate whether a compound that is an effective inhibitor of binding when a single ligand such as ASF is used will be as effective when used in studies with cells that may express multiple cell surface ligands for ricin and/or the inhibitor.  相似文献   

7.
Surface plasmon resonance (SPR) is routinely applied on determining association or dissociation constant rates of antigen-antibody complexes. In a SPR system such as Biacore, the capture method is a widely accepted procedure in kinetic analysis for association or dissociation of soluble antigen analytes with antibody ligands initially captured by anti-Fc molecules immobilized on the sensor chip. Appropriate preparations of anti-immunoglobulin G (IgG)-Fc molecules on sensor chips have not been examined yet for stable kinetic analysis of antibodies with several affinities to soluble antigens. Here, we constructed murine monoclonal antibodies (MoAbs) with various affinities to hen egg lysozyme (HEL) and performed kinetic analysis of these MoAbs captured by rat MoAbs against mouse IgG-Fc immobilized on the sensor chip. When capture molecules maximally immobilized on the sensor chip, we observed no apparent dissociation of MoAbs with extremely high affinity to soluble HEL antigens. In contrast, on the limited amount (1000-2000 response units) of capture molecule immobilized on the sensor chip, we could perform stable kinetic analysis of MoAbs with highest affinities to the antigen as well as those with lower or moderate binding affinities. Thus, in some cases, accurate kinetic analysis of high-affinity antibodies can be performed by minimization of capture molecule densities on the sensor chip in SPR.  相似文献   

8.
Surface plasmon resonance (SPR) nanosensors based on metallic nanohole arrays have been widely reported to detect binding interactions in biological specimens. A simple and effective method for constructing nanoscale arrays is essential for the development of SPR nanosensors. In this work, we report a one-step method to fabricate nanohole arrays by thermal nanoimprinting in the matrix of IPS (Intermediate Polymer Stamp). No additional etching process or supporting substrate is required. The preparation process is simple, time-saving and compatible for roll-to-roll process, potentially allowing mass production. Moreover, the nanohole arrays were integrated into detection platform as SPR sensors to investigate different types of biological binding interactions. The results demonstrate that our one-step method can be used to efficiently fabricate large-area and uniform nanohole arrays for biochemical sensing.  相似文献   

9.
A new sensing area for a sensor based on surface plasmon resonance (SPR) was fabricated to detect trace amounts of mercury and lead ions. The gold surface used for SPR measurements were modified with polypyrrole-chitosan (PPy-CHI) conducting polymer composite. The polymer layer was deposited on the gold surface by electrodeposition. This optical sensor was used for monitoring toxic metal ions with and without sensitivity enhancement by chitosan in water samples. The higher amounts of resonance angle unit (ΔRU) were obtained for PPy-CHI film due to a specific binding of chitosan with Pb(2+) and Hg(2+) ions. The Pb(2+) ion bind to the polymer films most strongly, and the sensor was more sensitive to Pb(2+) compared to Hg(2+). The concentrations of ions in the parts per million range produced the changes in the SPR angle minimum in the region of 0.03 to 0.07. Data analysis was done by Matlab software using Fresnel formula for multilayer system.  相似文献   

10.
In order to examine the possibility of the use of a surface plasmon resonance (SPR) sensor for real-time monitoring of the process of refolding of immobilized proteins, the refolding of firefly luciferase immobilized on a carboxymethyldextran matrix layer was analyzed. The SPR signal of the immobilized luciferase decreased after unfolding induced by GdnCl and increased gradually in the refolding buffer, while there was no signal change in the reference surface lacking the immobilized protein. The decrease in the SPR signal on unfolding was consistent with the difference between the refractive indices of the native and unfolded protein solutions. The effects of blocking of the excess NHS-groups of the matrix layer on the refolding yield were examined by means of an SPR sensor. The results were consistent with those obtained with the enzymatic activity assay, indicating that the changes in the SPR signal reflected the real-time conformational changes of the immobilized protein. Hence, an SPR biosensor might be used for monitoring of the process of refolding of immobilized proteins and as a novel tool for optimization of the refolding conditions. This is the first demonstration that SPR signal changes reflect the conformational changes of an immobilized protein upon unfolding and refolding.  相似文献   

11.
Surface plasmon resonance (SPR) is a powerful technique for measuring molecular interaction in real-time. SPR can be used to detect molecule to cell interactions as well as molecule to molecule interactions. In this study, the SPR-based biosensing technique was applied to real-time monitoring of odorant-induced cellular reactions. An olfactory receptor, OR I7, was fused with a rho-tag import sequence at the N-terminus of OR I7, and expressed on the surface of human embryonic kidney (HEK)-293 cells. These cells were then immobilized on a SPR sensor chip. The intensity of the SPR response was linearly dependent on the amount of injected odorant. Among all the aldehyde containing odorants tested, the SPR response was specifically high for octanal, which is the known cognate odorant for the OR I7. This SPR response is believed to have resulted from intracellular signaling triggered by the binding of odorant molecules to the olfactory receptors expressed on the cell surface. This SPR system combined with olfactory receptor-expressed cells provides a new olfactory biosensor system for selective and quantitative detection of volatile compounds.  相似文献   

12.
In this paper we describe the use of a commercial surface plasmon resonance (SPR) imaging instrument for monitoring the binding of biomolecules on user-defined regions of interest of a microarray. By monitoring the angle shift of the SPR-dip using a continuous angle-scanning mode instead of monitoring the change in reflectivity at a fixed angle, a linear relationship with respect to the mass density change on the surface will remain over a wide dynamic angle range of 8 degrees. Peptides (2.4 kDa) and proteins (150 kDa) were both spotted on the same sensor chip to illustrate that both, low and high molecular weight ligands with initial large differences in off-set SPR angles, can be applied within the same experiment. By using a fluorescently labeled antibody, SPR results can be confirmed by means of fluorescence microscopy after completion of a SPR experiment. SPR imaging in angle-scanning operation provides sensitive, accurate, and label-free detection of analyte binding on microarrays containing different molecular weight ligands.  相似文献   

13.
In this paper the development of the first direct surface plasmon resonance (SPR) immunoassay for the detection of benzoylecgonine (BZE) is described. Immunosensor chips consisting of a high affinity monoclonal anti-BZE-antibody (anti-BZE-Ab) immobilized at high density to a sensor chip were prepared. First, BZE detection in Hepes buffer was achieved by direct, real time monitoring of the binding between BZE in solution and the surface bound antibody. The detection protocol was based on calibration curves obtained from reaction rate data and end point data analysis of sensorgrams registered after injection of a series of known BZE concentrations over the chips. Moreover, immunosensor accuracy, reproducibility, stability and robustness were tested to demonstrate their good performance as reusable devices. The immunosensor was used for BZE detection in oral fluid (OF) showing that, within 180 s, our immunoassay detects BZE concentrations as low as 4 μg/L in filtered OF-buffer (1:4) samples. This value is remarkably lower than current cut off levels established by the Substance Abuse and Mental Health Services Administration. These results manifest the potential use of this direct SPR immunoassay for the in situ sensitive detection of recent cocaine abuse, of utility in roadside drug OF testing. Moreover, it exemplifies the high potential of direct SPR immunoassays for the rapid, sensitive detection of small molecules in contrast with the more established indirect methods.  相似文献   

14.
Fang X  Tie J  Xie Y  Li Q  Zhao Q  Fan D 《Cancer epidemiology》2010,34(5):648-651
Background: MG7-Ag is a kind of gastric cancer-specific tumor-associated antigen and has been investigated to serve as a marker of gastric cancer for early diagnosis. Methods: Surface plasmon resonance (SPR) sensor was used for the detection of MG7-Ag in the sera of gastric cancer patients to develop an innovative, simple and rapid assay method for early diagnosis. The specific monoclonal MG7 antibodies were used as capture and detection receptors which were immobilized on the surface of SPR sensor chips for MG7-Ag identification in the human sera. The measurements include 9 cases of gastric cancer patients and 2 cases of healthy blood donors and a MKN45 cancer cell lysate solution sample for positive control. Results: The binding of MG7-Ag onto the sensor surface was observed from SPR spectra. The sera of most gastric cancer patients revealed much higher expression level of MG7-Ag than healthy human sera did in SPR measurement. Conclusion: The initial results demonstrate that the SPR biosensor has the potential for its application in the early diagnosis of gastric cancer. However, more tests need to be done to confirm the detection limitation and the criterion for cancer risk evaluation in early diagnosis.  相似文献   

15.
Nitrilotriacetate (NTA)-mediated capture of a histidine-tagged protein is widely used as an easy and simple method to reversibly immobilize the protein onto a sensor chip for surface plasmon resonance (SPR). However, in spite of its advantages, the NTA-capturing strategy is rarely employed for ligand screening experiments using SPR, because it was thought to cause substantial errors in binding responses, due to the inevitable protein dissociation during the monitoring period. In this study, as demonstrated in a ligand screening for the histidine-tagged SH3 domain of the human phosphatidylinositol 3-kinase p85alpha subunit, false responses after adhesion of undesirable compounds to a target protein could be minimized with the NTA strategy, while binding responses of a positive control peptide still stayed within a 1%-deviation against the theoretical binding capacity.  相似文献   

16.
Although surface plasmon resonance (SPR) biosensor technique has been used to study protein-protein interactions and to detect conformational changes of proteins, it has not been shown whether the SPR biosensor can be used to study a complex kinetic system such as the protein-DNA binding, which sometimes involves several binding steps as well as dynamic conformational changes of the complexes. In this study, we have used SPR biosensor and T7 polymerase as the model system to study the interactions of the polymerase with a series of DNA template-primer duplexes containing different number of mismatches and GC contents at various positions near the primer 3'-end. In general, the binding constants measured by the SPR are several magnitudes smaller than those determined in solution, indicating the limitation of the surface-based technique for measuring solution-based interactions. However, the distinct polymerase binding profiles obtained for DNA duplexes differed by as low as a single mismatch suggest that the SPR data can be used for relative comparison purpose among a set of experiments carried out under identical conditions. The successful fitting of the binding profiles using the established translocation model also demonstrated that SPR can be used to monitor conformational changes, as well as to derive relative kinetic values, within a complicated DNA-protein interaction system. The results also demonstrated that SPR biosensor may be used as a sensitive technique for studying molecular recognition events, such as single-base discrimination involved in protein-DNA interactions.  相似文献   

17.
Animal toxins that inhibit voltage-gated sodium (Nav) channel fast inactivation can do so through an interaction with the S3b–S4 helix-turn-helix region, or paddle motif, located in the domain IV voltage sensor. Here, we used surface plasmon resonance (SPR), an optical approach that uses polarized light to measure the refractive index near a sensor surface to which a molecule of interest is attached, to analyze interactions between the isolated domain IV paddle and Nav channel–selective α-scorpion toxins. Our SPR analyses showed that the domain IV paddle can be removed from the Nav channel and immobilized on sensor chips, and suggest that the isolated motif remains susceptible to animal toxins that target the domain IV voltage sensor. As such, our results uncover the inherent pharmacological sensitivities of the isolated domain IV paddle motif, which may be exploited to develop a label-free SPR approach for discovering ligands that target this region.  相似文献   

18.
An immunosensing system based on surface plasmon resonance (SPR) was used for on-line detection and characterization of carbohydrate molecules separated by high-performance liquid chromatography. These analytes, with or without serum, were continuously separated and analyzed in the combined liquid chromatography-surface plasmon resonance (LC-SPR) system. By using weak and readily reversible monoclonal antibodies, the SPR system allowed specific on-line monitoring of the substances. To increase the specificity of the immunosensor, nonrelevant antibodies were used as reference in a serial flow cell. The sensitivity of the LC-SPR system was dependent on molecular weight of the carbohydrate, affinity of binding, and design of the sensor.  相似文献   

19.

Many environmental applications exist for biosensors capable of providing real-time analyses. One pressing current need is monitoring for agents of chemical- and bio-terrorism. These applications require systems that can rapidly detect small organics including nerve agents, toxic proteins, viruses, spores and whole microbes. A second area of application is monitoring for environmental pollutants. Processing of grab samples through chemical laboratories requires significant time delays in the analyses, preventing the rapid mapping and cleanup of chemical spills. The current state of development of miniaturized, integrated surface plasmon resonance (SPR) sensor elements has allowed for the development of inexpensive, portable biosensor systems capable of the simultaneous analysis of multiple analytes. Most of the detection protocols make use of antibodies immobilized on the sensor surface. The Spreeta 2000 SPR biosensor elements manufactured by Texas Instruments provide three channels for each sensor element in the system. A temperature-controlled two-element system that monitors for six analytes is currently in use, and development of an eight element sensor system capable of monitoring up to 24 different analytes will be completed in the near future. Protein toxins can be directly detected and quantified in the low picomolar range. Elimination of false positives and increased sensitivity is provided by secondary antibodies with specificity for different target epitopes, and by sensor element redundancy. Inclusion of more than a single amplification step can push the sensitivity of toxic protein detection to femtomolar levels. The same types of direct detection and amplification protocols are used to monitor for viruses and whole bacteria or spores. Special protocols are required for the detection of small molecules. Either a competition type assay where the presence of analyte inhibits the binding of antibodies to surface-immobilized analyte, or a displacement assay, where antibodies bound to analyte on the sensor surface are displaced by free analyte, can be used. The small molecule detection assays vary in sensitivity from the low micromolar range to the high picomolar.

  相似文献   

20.
Many environmental applications exist for biosensors capable of providing real-time analyses. One pressing current need is monitoring for agents of chemical- and bio-terrorism. These applications require systems that can rapidly detect small organics including nerve agents, toxic proteins, viruses, spores and whole microbes. A second area of application is monitoring for environmental pollutants. Processing of grab samples through chemical laboratories requires significant time delays in the analyses, preventing the rapid mapping and cleanup of chemical spills. The current state of development of miniaturized, integrated surface plasmon resonance (SPR) sensor elements has allowed for the development of inexpensive, portable biosensor systems capable of the simultaneous analysis of multiple analytes. Most of the detection protocols make use of antibodies immobilized on the sensor surface. The Spreeta 2000 SPR biosensor elements manufactured by Texas Instruments provide three channels for each sensor element in the system. A temperature-controlled two-element system that monitors for six analytes is currently in use, and development of an eight element sensor system capable of monitoring up to 24 different analytes will be completed in the near future. Protein toxins can be directly detected and quantified in the low picomolar range. Elimination of false positives and increased sensitivity is provided by secondary antibodies with specificity for different target epitopes, and by sensor element redundancy. Inclusion of more than a single amplification step can push the sensitivity of toxic protein detection to femtomolar levels. The same types of direct detection and amplification protocols are used to monitor for viruses and whole bacteria or spores. Special protocols are required for the detection of small molecules. Either a competition type assay where the presence of analyte inhibits the binding of antibodies to surface-immobilized analyte, or a displacement assay, where antibodies bound to analyte on the sensor surface are displaced by free analyte, can be used. The small molecule detection assays vary in sensitivity from the low micromolar range to the high picomolar.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号