首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
Our interests are in the development of immunoassay-based fast scanning methods for persistent organic pollutants. To develop the immunoassay method of polybrominated diphenyl ether (PBDE), a model compound of PBDE, 2,3′,4,5′,6-pentabromodiphenylether (BDE-121), has been chosen to develop its antibody and the competitive indirect enzyme-linked immunosorbent assay (ELISA) is developed. The hapten of BDE-121 containing reactive carboxylic acid was synthesized and conjugated to carrier proteins (bovine serum albumin [BSA] and ovalbumin [OVA]). Anti-BDE-121 polyclonal antibody was then developed in rabbits as a result of immunization with the BDE-121–BSA conjugate. The optimal amount of coating antigen BDE-121–OVA conjugate and the dilution of antiserum needed in the ELISA were determined with the checkerboard method, and the effects of the properties of PBST (phosphate-buffered saline and Tween 20) buffer (pH and salt concentration) and chemical solvent (types and concentrations) on the ELISA were investigated to achieve a rapid robust assay with high sensitivity. Under the optimized conditions, the developed indirect ELISA shows a linear detection range from 1.74 to 84.1 ng/ml, with an IC50 value of 8.07 ng/ml and a detection limit of 0.644 ng/ml. In total, 11 kinds of compounds were tested for calculating the cross-reactivity, which was less than 8% for nearly all of them. Real samples were analyzed by the proposed immunoassay and gas chromatography/mass spectrometry (GC/MS).  相似文献   

2.
We have developed a new method for highly selective determination of the ubiquitin carboxyl-terminal hydrolase L1 (UCH-L1) concentration using a surface plasmon resonance imaging (SPRI) technique and two different biosensors. UCH-L1 was captured from a solution by immobilized specific rabbit monoclonal antibody or specific LDN-57444 inhibitor due to formation of receptor–UCH-L1 complex on the biosensor surface. The analytically useful dynamic response range of both biosensors is between 0.1 and 2.5 ng/ml. The detection limit is 0.06 ng/ml for the biosensor with antibody and 0.08 ng/ml for the biosensor with inhibitor. Biosensors based on both antibody and inhibitor were found to be suitable for quantitative determination of the UCH-L1 and exhibit good tolerance to the potential interferents. Both biosensors gave comparable results in the range of 0 to 0.20 ng/ml for plasma samples and 0.30 to 0.49 ng/ml for cerebrospinal fluid samples. To validate the new methods, comparative determination of UCH-L1 by the commercial enzyme-linked immunosorbent assay (ELISA) kit was performed. In general, in terms of UCH-L1 concentration, a good correlation between SPRI and ELISA was found. The developed biosensors can be used successfully for the determination of UCH-L1 in body fluids.  相似文献   

3.
Tris(2,3-dibromopropyl) isocyanurate (TBC) is a novel brominated flame retardant (BFR) that is widely used to substitute the prohibited BFRs throughout the world. With the development of research, the potential environmental and ecological harms of TBC have been revealed. For sensitive and selective detecting TBC, an indirect competitive biotin–streptavidin-amplified enzyme-linked immunosorbent assay (BA–ELISA) has been established in this study. The small molecular TBC–hapten was synthesized first; it mimicked the chemical structure of TBC and possessed a secondary amine group. The as-obtained hapten was then conjugated with carrier proteins to prepare artificial antigen. After immunization, the anti-TBC polyclonal antibody was obtained from separating rabbit serum. The procedures of this BA–ELISA were optimized. Under the optimal conditions, the limit of detection (IC10) was 0.0067 ng/ml and the median inhibitory concentration (IC50) was 0.66 ng/ml. Cross-reactivity values of the BA–ELISA with the tested TBC analogues were ?5%. This immunoassay was successfully applied to determine the TBC residue in river water samples that were collected near a BFR manufacturing plant. Satisfactory recoveries (92.1–109.2%) were obtained. The results indicated that this proposed BA–ELISA is suitable for the rapid and sensitive determining of TBC in environmental monitoring.  相似文献   

4.
In this study, we developed a CdSe/ZnS quantum dot (QD)-based immunoassay for use in determining the presence of progesterone (P4) in human serum. Hydrophilic QDs were conjugated to anti-progesterone antibody (P4Ab) via ethyl-3-(dimethylaminopropyl)carbodiimide (EDC) and N-hydroxysuccinimide (NHS) as coupling reagents. After purification, the P4Ab–QD conjugates were immobilized onto the wells of a 96-well microtiter plate, and a direct-binding immunoassay based on the binding of P4 to immobilized P4Ab–QD conjugates had a detection limit of 0.21 ng/ml and a sensitivity of 1.37 ng/ml, with a linear range of 0.385 to 4.55 ng/ml. The proposed immunoassay was successfully used to determine the P4 concentration in real human serum, and the results showed a good correlation with the accredited radioimmunoassay (RIA).  相似文献   

5.
Nanoparticles have successfully been employed in immunometric assays that require high sensitivity. Certain analytes, however, require dynamic ranges (DRs) around a predetermined cut-off value. Here, we have studied the effects that antibody orientation and addition of free solid-phase and detection antibodies have on assay sensitivity and DR in traditional sandwich-type immunoassays. D-dimer and cardiac troponin I (cTnI), both routinely used in critical care testing, were applied as model analytes. The assays were performed in microtitration wells with preimmobilized solid-phase antibody. Inherently fluorescent nanoparticles coated with second antibody were used to detect the analyte. The selection of antibody orientation and addition of free solid-phase or detection antibody, with nanoparticles and calibrator, desensitized the assays and extended the DR. With D-dimer the upper limit of the DR was improved from 50 to 10,000 ng/ml, and with cTnI from 25 to 1000 ng/ml. Regression analysis with the Stago STA Liatest D-dimer assay yielded a slope (95% confidence interval) of 0.09 (0.07–0.11) and a y-intercept of −7.79 (−17.87–2.29) ng/L (n = 65, r = 0.906). Thus it is concluded that Europium(III)-chelate-doped nanoparticles can also be employed in immunoassays that require wide DRs around a certain cut-off limit.  相似文献   

6.
A direct competitive enzyme-linked immunosorbent assay (ELISA) has been developed for detection of diethyl phthalate (DEP). Protein-hapten conjugate was synthesized to produce polyclonal antibodies against DEP. Experimental parameters were optimized, including immunoreaction conditions, the dilution ratio of horseradish peroxidase (HRP)-antigen conjugate, time of the antibody coated, effect of pH, and ionic strength. The limit of detection was 0.096 ng/ml, and the linear range was 0.1-3500 ng/ml with a regression coefficient (R2) of 0.9957. Recoveries were between 96.4 and 106.2%. The cross-reactivities of the anti-DEP antibody to six structurally related phthalate esters were less than 9%. The method was successfully applied to the determination of DEP in tap water, river water (Yangtze River), and leachate from plastic drinking bottles. This immunoassay was highly specific, sensitive, rapid, simple, and suitable for DEP monitoring. The results obtained were compared with those obtained using the high-performance liquid chromatography method.  相似文献   

7.
A high‐throughput and simple chemiluminescence (CL) enzyme immunoassay (CLEIA) for the determination of progesterone (P) in human serum was developed, with the highly sensitive 4‐methoxy‐4‐(3‐phosphatephenyl)‐spiro‐(1,2‐dioxetane‐3,2′‐adamantane) (AMPPD)–alkaline phosphatase (ALP) system as the CL detection system. The results showed that the indirect immobilization of rabbit anti‐progesterone polyclonal antibody (RAPA) through secondary antibody exhibited apparent advantages over direct coating in terms of antibody saving and improvement of the coating stability and uniformity. The direct analysis of P in human serum without extraction was realized by using 8‐anilino‐1‐naphthalenesulphonic acid (ANS) to displace P from its binding proteins. The effect of several relevant parameters of the immunoreaction were examined and optimized. Compared with some commercial progesterone kits, the presented CLEIA has higher sensitivity with detection limitation as low as 0.06 ng/mL. The recoveries were 95.9–101%. The coefficient of variation was <8.4% and 9.9% for intra‐ and inter‐assay precision, respectively. This method has been successfully applied to the evaluation of P in human serum. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

8.
The catalytic activity of gold nanoparticles (AuNPs) on a luminol–H2O2 chemiluminescence (CL) system is found to be greatly enhanced after its crosslinking aggregation induced by immunoreaction. Based on this observation, a one-step homogeneous non-stripping CL metalloimmunoassay was designed. In the presence of corresponding antigen (Ag), the immunoreaction caused the aggregation of antibody (Ab)-modified AuNPs, and these crosslinking aggregated AuNPs could catalyze luminol–H2O2 CL reaction to produce a much stronger CL signal than dispersed Ab-modified AuNPs. The assay, including immunoreaction and detection, can be accomplished in homogeneous solution. In the assay, no tedious and strict stripping of metal nanoparticles, difficult synthesis of labels, multiple steps of immunoreactions and washings, and complicated magnetic separation process were required. The detection limit of human immunoglobulin G (IgG, 3σ) was estimated to be as low as 3.2 × 10−11 g ml−1. The sensitivity was increased by two orders of magnitude over that of other AuNP-based CL immunoassay. The current CL metalloimmunoassay offers the advantages of being simple, cheap, rapid, and sensitive.  相似文献   

9.
A sensitive, simple and rapid ultra fast liquid chromatography (UFLC)–ESI-MS/MS method was developed for the determination of 2-hydroxyflutamide in human plasma using tegafur as the internal standard. The plasma sample was pretreated with methanol for protein precipitation and the analytes were separated on an Ultimate C18 column (5 μm, 2.1 mm × 50 mm, MD, USA) with the mobile phase consisted of acetonitrile and water (2:1, v/v). Detection was performed on a triple-quadrupole tandem mass spectrometer under a negative multiple reaction-monitoring mode (MRM). The mass transition ion-pair was followed as m/z 290.90–204.8 for 2-hydroxyflutamide and 198.9–128.8 for tegafur. Linear calibration curves were obtained in the concentration range of 1.742–1452 ng/ml with a lower limit of quantification of 1.742 ng/ml. The intra- and inter-batch precision values were less than 8.1% and 5.6%, respectively. The established method was successfully applied to a bioequivalence study of two flutamide preparations (250 mg) in 20 healthy male volunteers.  相似文献   

10.
T Yasui  K Yoda 《Applied microbiology》1997,63(11):4528-4533
An ultrasensitive chemiluminescent enzyme immunoassay (CLEIA) was developed for the rapid detection and quantification of Lactobacillus brevis contaminants in beer and pitching yeast (Saccharomyces cerevisiae slurry collected for reinoculation). L. brevis cells trapped on a 47-mm nucleopore membrane (0.4-micron pore size) were reacted with a peroxidase-labelled Lactobacillus group E antibody and then subjected to an enhanced CLEIA analysis with 4-iodophenol as the enhancer. The combination of a nucleopore membrane with low background characteristics that enables the antigen-antibody reaction to proceed through the pores of the membrane and a labelled antibody prepared by the maleimide hinge method with minimal nonspecific binding characteristics was essential to minimize background in the detection of single cells. An ultrahigh sensitive charge-coupled device (CCD) camera equipped with a fiber optics image intensifier permitted the imaging of single cells. A clear correlation existed between the number of luminescent spots observed and the plate count [y (CLEIA) = 0.990x (plate count) + 15.9, where n = 7, r = 0.993, and P < 0.001]. Microscopic observation confirmed that the luminescent spots were produced by single cells. This assay could be used to detect approximately 20 L. brevis cells in 633 ml of beer within 4 h. Our ultrasensitive CLEIA could also be used to detect microcolonies approximately 20 microns in diameter which had formed on a membrane after 15 to 18 h of incubation. This method, which we called the microcolony immunoluminescence (MIL) method, increased the signal-to-noise ratio dramatically. The MIL method could be used to detect a 10(0) level of L. brevis contamination in 633 ml of beer and a 1/10(8) level of L. brevis contamination in pitching yeast within 1 day (15 to 18 h to form microcolonies and 2 h for CLEIA).  相似文献   

11.
We have developed and validated a sensitive liquid chromatography–electrospray ionization-mass spectrometric (LC–ESI-MS) method for the quantification of verticinone, a major active constituent from Fritillaria hupehensis Hsiao et KC Hsia., in rat plasma. Verticinone and the internal standard (IS), hupehenine, were extracted from plasma samples by a simple liquid–liquid extraction with ethyl acetate after being alkalified by 1 M ammonia hydroxide. Chromatographic separation was achieved on a C18 column using a gradient elution program with methanol and water as the mobile phase. The detection was performed by selected ion monitoring (SIM) mode via positive electrospray ionization (ESI) interface. The lower limit of quantification (LLOQ) was 0.1 ng/mL. The calibration curves were linear (r2 > 0.998) over the concentration range of 0.1–200 ng/mL. Within- and between-run precision was less than 6.5% and accuracy was within ±10.7%. The validated method was applied to the pharmacokinetic study of verticinone in rats after a single oral administration of 1 mg/kg.  相似文献   

12.
A homogeneous chemiluminescent immunoassay of thyroxine (T4) enhanced by microchip electrophoresis separation has been developed. The method deployed the competitive immunoreaction of T4 and horseradish peroxidase (HRP)-labeled T4 (HRP-T4) with anti-T4 mouse monoclonal antibody (Ab). HRP-T4 and the HRP-T4-Ab complex were separated and quantified by using microchip electrophoresis (MCE) with chemiluminescence (CL) detection. Highly sensitive CL detection was achieved by means of HPR-catalyzed luminol-H2O2 reaction. Due to the effective MCE separation, the CL analytical signal was less prone to sample matrix interference. Under the selected assay conditions, the MCE separation was accomplished within 60 s. The linear range for T4 was 5-250 nM with a detection limit of 2.2 nM (signal/noise ratio = 3). The current method was successfully applied for the quantification of T4 in human serum samples. It was demonstrated that the current MCE-CL-enhanced competitive immunoassay was quick, sensitive, and highly selective. It may serve as a tool for clinical analysis of T4 to assist in the diagnosis of thyroid gland functions.  相似文献   

13.
Midazolam is an ultra short acting benzodiazepine derivative and a specific probe for phenotyping cytochrome P450 (P450) 3A4/5 activity. A rapid, sensitive, and selective LC–MS/MS method was developed for simultaneous quantitation of midazolam and its metabolites (1′-hydroxymidazolam and 4-hydroxymidazolam). Deuterated (D5) analog of midazolam was utilized as an internal standard. Sample preparation either from human plasma (100 μL) or liver microsomal incubations involved a simple protein precipitation using acetonitrile (900 μL) with an average recovery of >90% for all compounds. The chromatographic separation was achieved using Zorbax-SB Phenyl, Rapid Resolution HT (2.1 mm × 100 mm, 3.5 μm) and a gradient elution with 10 mM ammonium acetate in 10% methanol (A) and acetonitrile (B). The flow rate was 0.25 mL/min and total run time was 5.5 min. Calibration curves were linear over the concentration range of 0.100–250 ng/mL. The lower limit of quantitation (LLOQ) was 0.1 ng/mL for all three analytes. The accuracy and precision, estimated at LLOQ and three concentration levels of quality control samples in six replicates, were within 85–115%. In conclusion, a robust, simple and highly sensitive analytical method was developed and validated for the analysis of midazolam and its metabolites. This method is suitable for characterizing the P450 3A4/5 activity in vitro or in human pharmacokinetic studies allowing administration of smaller doses of midazolam.  相似文献   

14.
Lixia Zhao  Dan Wang  Gen Shi  Ling Lin 《Luminescence》2017,32(8):1547-1553
The specificity for early diagnostic of prostate‐specific antigen (PSA) is low because the current technology mostly allows the detection of only one biomarker at one time. In this work, a dual‐labeled chemiluminescence enzyme immunoassay (CLEIA) for simultaneous measurement of total PSA (TPSA) and free PSA (FPSA) was proposed. Anti‐PSA McAb (Mab1) was immobilized on a microplate as the solid phase, horseradish peroxidase (HRP)‐labeled anti‐TPSA monoclonal antibody (McAb2) and alkaline phosphatase (ALP)‐labeled anti‐FPSA McAb3 were used as detection antibodies. Two chemiluminescence reactions of HRP with luminol and ALP with 4‐methoxy‐4‐(3‐phosphate‐phenyl)‐spiro‐(1,2‐dioxetane‐3,2′‐adamantane) (AMPPD) were used as the signal detecting system. Based on a sandwich model, the amount of FPSA and TPSA could be determined simultaneously. The effects of several physico‐chemical parameters were studied and optimized. Cross‐reactivities of six common tumor markers in serum were studied. The proposed method presented the sensitivity of 0.03 ng ml?1 and 0.05 ng ml?1 for FPSA and TPSA respectively, with low cross‐reactivities. Compared with the results from commercial chemiluminescent kits there was good correlation, indicating that this established method could be used to simultaneously to measure the concentrations of FPSA and TPSA in one serum sample and also could greatly facilitate the early diagnosis for PCa in clinical practice.  相似文献   

15.
In prostate cancer screening, prostate-specific antigen (PSA) has been utilized as a valuable biomarker. There are routinely used procedures based on enzyme-linked immunosorbent assay (ELISA) for PSA detection. The procedures based on ELISA, however, are time consuming, complicated, and costly. We have developed a rapid, very simple, cost effective and sensitive immunochromatographic assay using gold nanoparticles and evaluated its applications for first screening of prostate cancer in serum samples. The sensitive immunochromatographic assay requires only 40 μL of the serum sample. The assay used is rapid and simple, that it totally takes approx 15 min to complete. The method for sensitive immunochromatographic assay has the other advantage of decreasing the antibody concentration that is used for the test line. In this study, we show the advantage to decrease the antibody concentration and the evaluation of our sensitive immunochromatographic assay for the semiquantitative detection of PSA in serum. The results obtained from 163 serum samples using sensitive immunochromatographic assay are compared with the results obtained using the chemiluminescent enzyme immunoassay (CLEIA) and normal immunochromatographic assay. The results obtained in the sensitive immunochromatographic assay correlated well with the values obtained in CLEIA. We concluded that our sensitive immunochromatographic assay is applicable to the first screening test for the diagnosis of prostate cancer. Our developed sensitive immunochromatographic assay is a promising candidate for diagnosis or research use, which may become commercially available in the near future.  相似文献   

16.
Erythromycin (ERY), clarithromycin (CLA), roxithromycin (ROX), and azithromycin (AZI) are macrolide antibiotics widely used in livestock and human medicine. Therefore, they are frequently found as pollutants in environmental water. A method based on indirect competitive enzyme-linked immunosorbent assay (ELISA) for group determination of these macrolides in foodstuffs, human biofluids, and water was developed. Carboxymethyloxime of clarithromycin (CMO–CLA) was synthesized and conjugated to bovine serum albumin (BSA) and gelatin to prepare immunogen and coating antigen with advantageous presentation of target epitopes, l-cladinose and d-desosamine, common for these analytes. Antibodies generated in rabbits were capable of recognizing ERY, CLA, and ROX as a group (100–150%), and AZI (12%) and did not cross-react with ERY degradants, which lack antibiotic activity. Assay displayed sensitivity of determination of 14-membered macrolides (IC50 = 0.13–0.2 ng/ml) and low limit of detection (LOD) that was achieved at 0.02 to 0.03 ng/ml. It allowed performing analysis of milk, muscle, eggs, bovine serum, water, human serum and urine, and avoiding matrix effect without special pretreatment using simple dilution with assay buffer. For 15-membered macrolide AZI, the corresponding characteristics were IC50 = 1.6 ng/ml and LOD = 0.14 ng/ml. The recoveries of veterinary and human medicine macrolides from corresponding matrices were validated and found to be satisfactory.  相似文献   

17.
A sensitive, reproducible, and rapid analytical method for the analysis of trace-level heterocyclic amines (HCAs) that are expected to have high levels of human exposure was developed. Liquid–liquid extraction (LLE) with dichloromethane (DCM) followed by solid-phase extraction (SPE) was carried out. Liquid extraction with DCM under basic conditions was efficient in extracting HCAs from urine samples. For further purification, mixed mode cationic exchange (MCX) cartridges were applied to eliminate the remaining interferences after liquid extraction. Separation and quantification were performed by liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS) in selected reaction monitoring (SRM) mode. The overall recoveries ranged between 71.0% and 113.6% with relative standard deviations (RSDs) of 5.1% to 14.7% for the entire procedure. The limits of detection (LODs) and limits of quantification (LOQs) of the proposed analytical method were in the ranges of 0.04 to 0.10 ng/ml and 0.15 to 0.36 ng/ml, respectively. This method was applied to the analysis of monitoring in urine samples for Korean school children, and the results demonstrated that the method can be used for the trace determination of HCAs in urine samples.  相似文献   

18.
A rapid, selective and highly sensitive high performance liquid chromatography–tandem mass spectrometry method (LC–MS/MS) was developed and validated for the determination and pharmacokinetic investigation of eptifibatide in human plasma. Eptifibatide and the internal standard (IS), EPM-05, were extracted from plasma samples using solid phase extraction. Chromatographic separation was performed on a C18 column at a flow rate of 0.5 mL/min. Detection of eptifibatide and the IS was achieved by tandem mass spectrometry with an electrospray ionization (ESI) interface in positive ion mode. Traditional multiple reaction monitoring (MRM) using the transition of m/z 832.6 → m/z 646.4 and m/z 931.6 → m/z 159.4 was performed to quantify eptifibatide and the IS, respectively. The calibration curves were linear over the range of 1–1000 ng/mL with the lower limit of quantitation validated at 1 ng/mL. The intra- and inter-day precisions were within 13.3%, while the accuracy was within ±7.6% of nominal values. The validated LC–MS/MS method was successfully applied for the evaluation of pharmacokinetic parameters of eptifibatide after intravenous (i.v.) administration of a 45 μg/kg bolus of eptifibatide to 8 healthy volunteers.  相似文献   

19.
Perchlorate can competitively inhibit iodide uptake by the thyroid gland (TG) via the sodium/iodide symporter, consequently reducing the production of thyroid hormones (THs). Until recently, the effects of perchlorate on TH homeostasis are being examined through measurement of serum levels of TH, by immunoassay (IA)-based methods. IA methods are fast, but for TH analysis, they are compromised by the lack of adequate specificity. Therefore, selective and sensitive methods for the analysis of THs in TG are needed, for assessment of the effects of perchlorate on TH homeostasis. In this study, we developed a method for the analysis of six THs: l-thyroxine (T4), 3,3′,5-triiodo-l-thyronine (T3), 3,3′,5′-triiodo-l-thyronine (rT3), 3,5-diiodo-l-thyronine (3,5-T2), 3,3′-diiodo-l-thyronine (3,3′-T2), and 3-iodo-l-thyronine (3-T1) in TG, using liquid chromatography (LC)–tandem mass spectrometry (MS/MS). TGs used in this study were from rats that had been placed on either iodide-deficient diet or iodide-sufficient diet, and that had either been provided with perchlorate in drinking water (10 mg/kg/day) or control water. TGs were extracted by pronase digestion and then analyzed by LC–MS/MS. The instrumental calibration range for each TH ranged from 1 to 200 ng/ml and showed a high linearity (r > 0.99). The method quantification limits (LOQs) were determined to be 0.25 ng/mg TG for 3-T1; 0.33 ng/mg TG for 3,3′- and 3,5-T2; and 0.52 ng/mg TG for rT3, T3, and T4. Rats were placed on an iodide-deficient or -sufficient diet for 2.5 months, and for the last 2 weeks of that period were provided either perchlorate (10 mg/kg/day) in drinking water or control water. Iodide deficiency and perchlorate administration both reduced TG stores of rT3, T3, and T4. In iodide-deficient rats, perchlorate exacerbated the reduction in levels of THs in TG. With the advances in analytical methodology, the use of LC–MS/MS for measurement of hormone levels in TG will allow more comprehensive evaluations of the hypothalamic-pituitary–thyroid axis.  相似文献   

20.
A rapid and sensitive liquid chromatography–electrospray ionization-tandem mass spectrometry (LC–ESI-MS/MS) method to quantify thiamphenicol (TAP), florfenicol (FF), and florfenicol amine (FFA) in swine muscle is described. An immunoaffinity chromatography (IAC) column based on polyclonal antibodies and protein A-sepharose CL 4B was used to clean-up extracted samples. IAC optimized conditions were found that allowed the IAC to be reused for selective binding of TAP, FF, and FFA. The dynamic column capacity was more than 512 ng/mL of gel after being used for 15 cycles. From fortified swine muscle samples at levels of 0.4–50 ng/g, the average recoveries were 85.2–98.9% with intra- and inter-day variations less than 9.8% and 12.4%, respectively. The limit of quantitation ranged from 0.4 to 4.0 μg/kg.  相似文献   