首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A rapid, sensitive and accurate high-performance liquid chromatographic method with UV detection was developed and validated for the quantification of gabapentin in human plasma. Gabapentin was quantified using pre-column derivatization with 1-fluoro-2,4-dinitrobenzene following protein precipitation of plasma with acetonitrile. Amlodipine was used as internal standard. The chromatographic separation was carried out on a Nova-Pak C(18) column using a mixture of 50 mM NaH(2)PO(4) (pH=2.5)-acetonitrile (30:70, v/v) as mobile phase with UV detection at 360 nm. The flow rate was set at 1.5 ml/min. The method was linear over the range of 0.05-5 microg/ml of gabapentin in plasma (r(2)>0.999). The within-day and between-day precision values were in the range of 2-5%. The limit of quantification of the method was 0.05 microg/ml. The method was successfully used to study the pharmacokinetics of gabapentin in healthy volunteers.  相似文献   

2.
A selective and sensitive high-performance liquid chromatography method has been developed and validated for determination of mitiglinide (MGN) in rat plasma using 2-(4-biphenylyl) propionic acid (BPA) as internal standard. Liquid-liquid extraction was used for sample preparation. Chromatographic separation was achieved on a C(18) column using acetonitrile and 0.02 mol/l KH(2)PO(4) buffer (pH 4.0) (45:55, v/v) as mobile phase delivered at 1.0 ml/min. The UV detector was set at 210 nm. The assay was linear over the range 0.1-20 microg/ml for MGN. The average extraction recoveries of MGN and BPA from rat plasma were 98.6 and 97.4%, respectively. The developed method has been applied to the pharmacokinetic study of MGN in rats.  相似文献   

3.
A high-performance liquid chromatographic method using liquid-liquid extraction was developed for the determination of 1-(3-fluoro-4-hydroxy-5-mercaptomethyl-tetrahydrofuran-2-yl)-5-methyl-1H-pyrimidine-2,4-dione (l-FMAUS; I) in rat plasma and urine. A 100 microl aliquot of distilled water containing l-cysteine (100 mg/ml) was added to a 100 microl aliquot of biological sample. l-Cysteine was employed to protect binding between the 5'-thiol of I and protein in the biological sample. After vortex-mixing for 30s and adding a 50 microl aliquot of the mobile phase containing the internal standard (10 microg/ml of 3-aminophenyl sulfone), 1 ml of ethyl acetate was used for extraction. After vortex-mixing, centrifugation, and evaporating the ethyl acetate, the residue was reconstituted with a 100 microl aliquot of the mobile phase. A 50 microl aliquot was injected onto a C(18) reversed-phase column. The mobile phases, 50 mM KH(2)PO(4) (pH = 2.5):acetonitrile (85:15, v/v) for rat plasma and 50 mM KH(2)PO(4) (pH 2.5):acetonitrile:methanol (85:10:5, v/v/v) for urine samples, were run at a flow-rate of 1.2 ml/min. The column effluent was monitored by an ultraviolet detector set at 265 nm. The retention times for I and the internal standard were approximately 9.7 and 12.5 min, respectively, in plasma samples and the corresponding values in urine samples were 16.8 and 14.9 min. The quantitation limits of I in rat plasma and urine were 0.1 and 0.5 microg/ml, respectively.  相似文献   

4.
A rapid and simple high-performance liquid chromatographic (HPLC) method has been developed and validated for determination of scopoletin in rat plasma using psoralen as internal standard. Chromatographic separation was achieved on a C(18) column using methanol and distilled water (49:51, v/v) containing 0.05% (v/v) phosphoric acid as mobile phase. The UV detector was set at 345 nm. The calibration curve was linear over the range of 0.165-9.90 microg/ml with a correlation coefficient of 0.9994. The recovery for plasma samples of 0.165, 1.32 and 6.60 microg/ml was 93.2%, 95.9% and 95.5%, respectively. The RSD of intra- and inter-day assay variations was less than 6.7%. This HPLC assay is a precise and reliable method for the analysis of scopoletin in pharmacokinetic studies.  相似文献   

5.
A fast and selective HPLC-MS-MS method was established to determine L-threonate in human plasma and urine. Plasma and urine samples were extracted by protein precipitation and diluted with water, then chromatographed on an YMC J'Sphere C(18) column with methanol-acetonitrile-10mM ammonium acetate (20:5:75, v/v) as mobile phase, and at a flow rate of 0.2 ml/min. Detection was performed on a triple-quadrupole tandem mass spectrometer using negative electrospray ionization (ESI). Multiple reactions monitoring (MRM) was used and L-threonate was quantified by monitoring the ion transition of m/z 134.5-->74.7. The linear calibration curves of L-threonate in plasma and urine were obtained over the concentration range of 0.25-50 microg/ml and 2.5-500 microg/ml, respectively. Lower limit of quantitation was 0.25 and 2.5 microg/ml, respectively. Accuracy was within 85-115%, and intra- and inter-batch precision (R.S.D.%) were within +/-15%. The method proved to be accurate and specific, and was applied to the pharmacokinetic study of L-threonate in Chinese healthy subjects.  相似文献   

6.
An HPLC method was developed and validated for the determination of mifepristone in human plasma. C(18) solid-phase extraction cartridges were used to extract plasma samples. Separation was by C(18) column; mobile phase, methanol-acetonitrile-water (50:25:25, v/v/v); flow rate, 0.8 ml/min; UV detection at 302 nm. The calibration curve was linear in the concentration range of 10 ng/ml to 20 microg/ml (r=0.9991). Within- and between-day variability were acceptable. The limit of detection for the assay was 6 ng/ml. Plasma samples were stable for at least 7 days in the state of plasma or residue treated at -20 degrees C. The method was simple, sensitive and accurate, and allowed to determine ng mifepristone in human plasma. It could be applied to assess the plasma level of mifepristone in women receiving low oral doses of mifepristone.  相似文献   

7.
A sensitive and specific high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS-MS) method has been developed for the simultaneous determination of amiodarone and desethylamiodarone in human plasma. After the addition of the internal standard tamoxifen, plasma samples were extracted using Oasis MCX solid-phase extraction cartridges. The compounds were separated on a 5 microm Symmetry C18 (Waters) column (150 x 3.0 mm, internal diameter) with a mobile phase of acetonitrile-0.1% forrmic acid (46:54, v/v) at a flow-rate of 0.5 ml/min. The overall extraction efficiency was more than 89% for both compounds. The assay was sensitive down to 1 microg/l for amiodarone and down to 0.5 microg/l for desethylamiodarone. Within-run accuracies for quality-control samples were between 95 and 108% of the target concentration, with coefficients of variation <8%. The proposed method enables the unambiguous identification and quantitation of amiodarone and desethylamiodarone in both clinical and forensic specimens.  相似文献   

8.
20 (R,S)-Ginsenoside-Rg2, an anti-shock agent, is prescribed as a racemate. To analyze simultaneously the enantiomers of 20 (R)-ginsenoside-Rg2 and 20 (S)-ginsenoside-Rg2 in plasma, a simple and reproducible high-performance liquid chromatographic (HPLC) method has been developed. The enantiomeric separation and determination were successfully achieved using a Diamonsil ODS C18 reversed-phase column (5 microm, 250 mm x 4.6 mm) with an RP18 (5 microm) guard column and a mobile phase of MeOH-aq. 4% H3PO4 (65:35, v/v, pH 5.1) with UV detection at 203 nm. Both enantiomers, 20 (R)-ginsenoside-Rg2 and 20 (S)-ginsenoside-Rg2, were well separated at 14.5 min and 13.6 min, respectively. The linear ranges of the standard curves were 2.0-250 microg/ml. The intra- and inter-day precision (R.S.D.) were 相似文献   

9.
A reversed-phase high-performance liquid chromatographic method using a mobile phase of acetonitrile-methanol-trifluoroacetic acid-water (16.1:7.2:0.1:76.6, v/v/v/v) at a flow rate of 1.0 ml min(-1) on a LiChrospher RP-18 column with UV (254 nm) detection has been developed for the separation of sulfadoxine and its metabolite N-acetyl sulfadoxine in plasma. No interferences due to endogenous compounds or common antimalarial drugs were noticed. The limit of detection for sulfadoxine and N-acetyl sulfadoxine was 0.01 microg ml(-1) with a signal-to-noise ratio of 5:1 while the limit of quantification was 2.5 microg ml(-1). Intra-day mean relative standard deviations (RSD's) for sulfadoxine and N-acetyl sulfadoxine were 2.6 and 2.8%, respectively, while mean inter-day RSD's for sulfadoxine and N-acetyl sulfadoxine were 2.4 and 2.8%, respectively. Extraction recoveries averaged 90.6% for sulfadoxine and 86.9% for N-acetyl sulfadoxine. The method was applied for the assay of sulfadoxine and its metabolite N-acetyl sulfadoxine in plasma from Plasmodium falciparum malaria patients. Mean plasma sulfadoxine concentrations on day 2 (51 h) from samples collected from sensitive and resistant P. falciparum patients treated with three tablets of Fansidar were 62.8 and 60.5 microg ml(-1), respectively. Mean ratio of N-acetyl sulfadoxine to sulfadoxine was 9.1% for responders and 13.9% for non-responders which revealed that higher amounts of the metabolite N-acetyl sulfadoxine were present in non-responders. The method described should find an application in the therapeutic monitoring of malaria patients.  相似文献   

10.
A sensitive, rapid, selective and reproducible method has been developed to measure blood plasma levels of benzidine (BZ) and its acetylated metabolite, N-OH-N,N'-diacetylbenzidine (N-OH-DABZ), using supercritical fluid chromatography (SFC) for the first time. Benzidine and N-OH-N,N'-diacetylbenzidine were extracted from the plasma using ether. Separation was done on a Nucleosil (250 mm x 4.6 mm) 10 microm, Nucleosil-RP-C18 column with 7.4% (v/v) methanol-modified supercritical fluid carbon dioxide (2.5 ml min(-1)) as mobile phase. The column temperature was 45 degrees C and the outlet pressure was set at 8.83 MPa. The detection was done using a UV-Vis detector set at 280 nm. The limit of quantification was 0.10 ng ml(-1) (BZ) and 0.14 ng ml(-1) (N-OH-diacetylbenzidine) using 1 ml plasma specimen. The mean extraction recovery of BZ was found to be 98.6%. The SFC method was directly compared to a published HPLC-UV method. With respect to speed, organic solvent usage, sensitivity, specificity and accuracy, SFC was found to be superior. The method has been successfully used to estimate the BZ, N-OH-diacetylbenzidine levels in blood plasma of the animals who were administered 15 microg kg(-1) body weight of benzidine.Further, this method has been also applied for the detection and quantification of benzidine DNA and hemoglobin adducts from the blood and tissue samples of the benzidine dosed animals.  相似文献   

11.
A simple high-performance liquid chromatographic (HPLC) method was developed for the simultaneous determination of iohexol, iothalamate, p-aminohippuric acid (PAH) and n-acetyl-p-aminohippuric acid (n-acetyl-PAH) in human plasma and urine. A C(18) column at a flow rate of 1 ml/min with an aqueous mobile phase of trifluoroacetic acid (0.1% TFA in deionized water (pH 2.2), v/v) and methanol gradient was used for component separation. The plasma and urine assay demonstrated linearity from 10 to 50 microg/ml for iohexol and iothalamate, 5 to 40 microg/ml for PAH and 2.5 to 40 microg/ml for n-acetyl-PAH. The HPLC plasma and urine results obtained for PAH were used to calculate the subject kidney effective renal plasma flow (ERPF) and the iohexol results were used to calculate the subject kidney glomerular filtration rate (GFR). The HPLC results for PAH were then compared to an alternative colorimetric method for analyzing PAH to determine if subject metabolism (acetylation) of PAH affected the ERPF results obtained using the colorimetric method, the subsequent ERPF/GFR ratio and clinical impression of subject patient kidney function. The method was utilized in several different clinical studies evaluating the effect of kidney function from medications (phase IV evaluations) marketed for patients with cardiovascular disease.  相似文献   

12.
A HPLC method with UV detection at 262nm was developed to analyze inositol hexanicotinate in rat plasma. Plasma samples were extracted with an equal volume of acetonitrile, followed by dilution with mobile phase buffer (5mM phosphate buffer, pH 6.0) to eliminate any solvent effects. Inositol hexanicotinate and the internal standard (mebendazole) were separated isocratically using a mobile phase of acetonitrile/phosphate buffer (35:65, v/v, pH 6.0) at a flow rate of 1.0mL/min and a reverse-phase XTerra MS C(18) column (4.6mmx150mm, 3.5microm). The standard curve was linear over a concentration range of 1.5-100.0microg/mL of inositol hexanicotinate in rat plasma. The HPLC method was validated with intra- and inter-day precisions of 1.55-4.30% and 2.69-21.5%, respectively. The intra- and inter-day biases were -0.75 to 19.8% and 2.58-22.0%, respectively. At plasma concentrations of 1.5-100microg/mL, the mean recovery of inositol hexanicotinate was 99.6%. The results of a stability study indicated that inositol hexanicotinate was unstable in rat plasma samples, but was stable in acetonitrile extracts of rat plasma for up to 24h at 4 degrees C. The assay is simple, rapid, specific, sensitive, and reproducible and has been used successfully to analyze inositol hexanicotinate plasma concentrations in a pharmacokinetic study using the rat as an animal model.  相似文献   

13.
A reversed-phase high-performance liquid chromatographic method for the determination of sinefungin, a new antiprotozoal drug, in rat plasma has been developed and validated. Sample preparation was performed at 4°C by deproteinization with acetonitrile. Vidarabine was used as an internal standard. Both sinefungin and vidarabine were separated on a C18 column with a mobile phase of ammmonium dihydrogenphosphate-acetonitrile (95:5, v/v) and detected by ultraviolet absorbance at 260 nm. Recoveries of sinefungin from plasma were 75 ± 3.2% and 81 ± 4.8% following dosage at concentrations of 10 μg/ml and 30 μ/ml, respectively. Using 25- μl of rat plasma the limit of quantitation was 1 μg/ml sinefungin, and the assay was linear from 1 to 30 μg/ml. This method appears sensitive enough to be used in further pharmacokinetic studies of sinefungin in animal models.  相似文献   

14.
A gradient reversed-phase HPLC assay has been developed to determine sodium ferulate (SF) in beagle dog plasma with tinidazole as an internal standard. Chromatographic separation was made on a C(18) column using 0.5% acetic acid and acetonitrile (80:20, v/v) as mobile phase. UV detection was performed at 320 nm. The calibration curve for SF was linear in the range of 0.05-10 microg/ml, and the achieved limit of quantification (LOQ) was 51.4 ng/ml. The results of linearity, within- and between-day precision, and accuracy demonstrate that this method is reliable, sensitive and sufficient for in vivo beagle dog pharmacokinetic (PK) studies of SF.  相似文献   

15.
Liquid chromatographic assay for dicloxacillin in plasma   总被引:2,自引:0,他引:2  
A simple high-performance liquid chromatographic method for the determination of dicloxacillin in plasma has been developed. The method only requires 0.5 ml of plasma, phosphate buffer solution (pH = 4.7), acidification with 0.5N hydrochloride acid and liquid extraction with dichloromethane. Posterior evaporation of organic under nitrogen steam and redissolution in mobile phase is carried out. The analysis was performed on a Spherisorb C18 (5 microm) column, using methanol -0.05 M phosphate buffer, pH = 4.7 (75:25; v/v) as mobile phase, with ultraviolet detection at 220 nm. Results showed that the assay is sensitive: 0.5 microg/ml. The response is linear in the range of 0.5 - 10 microg/ml. Maximum inter-day coefficient of variation was 12.4%. Mean extraction recovery obtained was 96.95%. Stability studies showed that the loss was not higher than 10%, samples are stable at room temperature for 6 h, at -20 Celsius for 2 months, processed samples were stable at least for 24 h and also after two freeze-thaw cycles. The method has been used to perform pharmacokinetic and bioequivalence studies in humans.  相似文献   

16.
A highly sensitive and simple high-performance liquid chromatographic (HPLC) assay has been developed and validated for the quantification of dibenzoylmethane (DBM) in rat plasma. DBM and internal standard (I.S.) 1-(5-chloro-2-hydroxy-4-methylphenyl)-3-phenyl-1,3-propanedione (CHMPP) were extracted from rat plasma by ethyl acetate/methanol (95:5, v/v) and analyzed using reverse-phase gradient elution with a Phenomenex Gemini C18 5-mum column. A gradient of mobile phase (mobile phase A: water/methanol (80:20, v/v) with 0.1% TFA and mobile phase B: acetonitrile with 0.1% TFA) at a flow rate of 0.2 mL/min, and ultraviolet (UV) detection at 335 nm were utilized. The lower limit of quantification (LLOQ) using 50 microL rat plasma was 0.05 microg/mL. The calibration curve was linear over a concentration range of 0.05-20 microg/mL. The mean recoveries were 80.6+/-5.7, 83.4+/-1.6 and 77.1+/-3.4% with quality control (QC) level of 0.05, 1 and 20 microg/mL, respectively. Intra- and inter-day assay accuracy and precision fulfilled US FDA guidance for industry bioanalytical method validation. Stability studies showed that DBM was stable in rat plasma after 4h incubation at room temperature, one month storage at -80 degrees C and three freeze/thaw cycles, as well as in reconstitute buffer for 48 h at 4 degrees C. The utility of the assay was confirmed by the successful analysis of plasma samples from DBM pharmacokinetics studies in the rats after oral and intravenous administrations.  相似文献   

17.
Voriconazole is a widely used triazole antifungal agent with a broad spectrum including Aspergillus species. A simple, sensitive and selective high-performance liquid chromatography method for the determination of voriconazole in human plasma and saliva was developed. Drug and internal standard (UK-115 794) were extracted from alkaline plasma and saliva with n-hexane-ethyl acetate (3:1, v/v) and analyzed on a Luna C 18 column with fluorimetric detection set at excitation and emission wavelengths of 254 and 372 nm, respectively. The calibration curve was linear through the range of 0.1-10 microg/ml using a 0.3 ml sample volume. The intra- and inter-day precisions were all below 6.1% for plasma and below 9.1% for saliva. Accuracies ranged from 94 to 109% for both matrices. Mean recovery was 86+/-4% for voriconazole. The method showed acceptable values for precision, recovery and sensitivity and is well suited for routine analysis work and for pharmacokinetic studies.  相似文献   

18.
A high-performance liquid chromatographic (HPLC) method was developed using solid-phase extraction, o-phthalaldehyde (OPA) derivatization and fluorescence detection for the determination of the direct thrombin inhibitor bivalirudin in human plasma and urine. The use of this assay will facilitate the study of the pharmacodynamics of bivalirudin in studies of special patient populations. A C(18) bioanalytical column at a flow rate of 1 ml/min with an aqueous trifluoroacetic acid (0.1% TFA in deionized water, pH 2.2, v/v) mobile phase and methanol gradient was used. The assay demonstrated linearity from 3 to 20 microg/ml bivalirudin in plasma, with a detection limit of 1 microg/ml. The method was utilized in a study evaluating the pharmacokinetic and pharmacodynamic effects of bivalirudin in patients undergoing percutaneous coronary interventions (PCIs).  相似文献   

19.
A selective and sensitive high performance liquid chromatography-electrospray ionisation-mass spectrometry method has been developed for the determination of balofloxacin (BLFX) in human plasma. The sample preparation was a liquid-liquid extraction, and chromatographic separation was achieved with an Agilent ZORBAX 300SB C18 2.1 mm x 150 mm column using a mobile phase comprised of methanol-water (10 mM CH(3)COONH(4), pH 3.0)=40:60 (v/v). Standard curves were linear (r=0.9992) over the concentration range of 0.03-3 microg/ml and had good accuracy and precision. The within- and between-batch precisions were within 10% relative standard deviation (R.S.D.). The limit of detection (LOD) was 0.02 microg/ml. The validated HPLC-electrospray ionization (ESI)-MS method has been used successfully to study balofloxacin pharmacokinetics in healthy volunteers.  相似文献   

20.
A stereoselective reversed-phase HPLC assay to determine S-(-) and R-(+) enantiomers of esmolol in human plasma was developed. The method involved liquid-liquid extraction of esmolol from human plasma, using S-(-)-propranolol as the internal standard, and employed 2,3,4,6-tetra-O-acetyl-beta-d-glucopyranosyl isothiocyanate as a pre-column chiral derivatization reagent. The derivatized products were separated on a 5-microm reversed-phase C18 column with a mixture of acetonitrile/0.02 mol/L phosphate buffer (pH 4.5) (55:45, v/v) as mobile phase. The detection of esmolol derivatives was made at lambda=224 nm with UV detector. The assay was linear from 0.035 to 12 microg/ml for each enantiomer. The analytical method afforded average recoveries of 94.8% and 95.5% for S-(-)- and R-(+)-esmolol, respectively. For each enantiomer, the limit of detection was 0.003 microg/ml and the limit of quantification for the method was 0.035 microg/ml (RSD<14%). The reproducibility of the assay was satisfactory.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号