首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
Hair samples were obtained at various time periods from male Sprague-Dawley rats following the injection of cocaine hydrochloride in doses of 5, 10, and 20 mg/kg, ip, for 28 days. Hair samples were also taken continually after the dosing was stopped until the presence of cocaine and benzoylecgonine were no longer detected in hair. Cocaine and benzoylecgonine in hair and plasma were analyzed by gas chromatography/mass spectrometry. Both cocaine and benzoylecgonine were found in hair samples 4 days after the initiation of cocaine administration. When cocaine dosing was stopped after 28 days, approximately 25 to 30 days were required for cocaine and benzoylecgonine to disappear from rat hair in the group of animals that received the highest dose of cocaine. The disappearance of cocaine and benzoylecgonine followed first-order kinetics. The mean rate constant and mean half-life for cocaine disappearance from hair were 0.212 +/- 0.005 day-1 and 3.31 +/- 0.09 days, respectively, and the mean rate constant and mean half-life for benzoylecgonine disappearance from hair were 0.098 +/- 0.006 day-1 and 6.90 +/- 0.28 days, respectively. The mean plasma concentrations of cocaine on Day 25 for the 5, 10, and 20 mg/kg doses of cocaine were 508 +/- 42, 852 +/- 95, and 2027 +/- 75 ng/mL, respectively, and the mean plasma benzoylecgonine levels for the 5, 10, and 20 mg/kg doses of cocaine were 49.9 +/- 7.0, 103.3 +/- 9.3, and 191.0 +/- 16.0 ng/mL, respectively. There was a positive correlation between the doses of cocaine hydrochloride administered and the plasma levels of both cocaine and benzoylecgonine. This study showed that cocaine and benzoylecgonine can be measured in rat hair following the administration of cocaine and that it was possible to correlate the concentrations of cocaine and benzoylecgonine found in hair with the doses of cocaine that were administered.  相似文献   

2.
Cocaine hydrochloride, in doses of 0.5, 1.0, 2.0 and 4.0 mg/kg, iv, was administered to male Sprague-Dawley rats. Cerebrospinal fluid (CSF) was collected from the cisterna magna over a 20 min period and blood samples were obtained at 20 min after cocaine administration. In addition, blood samples for the 1 mg/kg dose of cocaine were collected at 2, 10, 20 and 30 min following drug injection. Gas chromatography/mass spectrometry was used for the analysis of cocaine and its metabolites in plasma and CSF. The disappearance of cocaine (1 mg/kg) from the plasma exhibited first order kinetics with a half-life of 18.11 +/- 3.22 min. Cocaine and benzoylecgonine were found in CSF and the concentrations of cocaine and benzoylecgonine increased in CSF as the doses of cocaine were increased. CSF flow rates were not altered by the iv administration of cocaine or benzoylecgonine. The CSF-to-plasma ratios for cocaine were quite similar to each other over the dosage range of cocaine that was administered; however, the CSF-to-plasma ratios for benzoylecgonine decreased as the concentrations of benzoylecgonine increased in plasma and CSF. When benzoylecgonine (2 mg/kg, iv) was given, the compound was detected in CSF indicating that benzoylecgonine can enter into the central nervous system from the peripheral blood. This investigation shows that cocaine and benzoylecgonine can be assayed in CSF and that the plasma levels of these compounds correlate with their concentrations in CSF.  相似文献   

3.
A sensitive, accurate, and reliable method is described for the quantitative determination of chloral hydrate (CH) and its metabolites in blood plasma of mice and rats. Metabolites of CH include trichloroacetic acid (TCA), trichloroethanol (TCE), and trichloroethanol glucuronide (TCE-Glu). This new method uses capillary gas chromatography with electron-capture detection (GC/ECD). Procedures for improving sample stability and quality assurance are also described that were not mentioned in previous literature. Rat or mouse plasma (50 microl) is acidified (or treated enzymatically for TCE-Glu determination) and extracted with peroxide free methyl t-butyl ether. Distilled diazomethane (CH(2)N(2)) is added to derivatize TCA to its methyl ester. Detection limits were estimated at 0.2 microg/ml for CH and TCE, and 0.1 microg/ml for TCA. Detector response to TCA and TCE were shown to be linear in the range of 3.125-200 microg/ml (r> or =0.9996). For CH, the response fits a second-order equation in this same range (r=0.99994)  相似文献   

4.
Cholinesterases can be used as sensitive biorecognition elements for widely used agricultural pesticides. This requires highly purified and inhibitor-free enzyme preparations. In the present work the cocaine derivative benzoylecgonine was for the first time used as the molecular recognition element for the purification of acetylcholinesterase from Electrophorus electricus by affinity chromatography. The preparation of enriched enzyme without the contamination by an inhibitor, which is traditionally used for eluting the "affinity" bound protein, was achieved. The specific activity was 2.2-fold increased to 3100 Umg(-1). The same cocaine derivative was immobilized on the surface of a piezoelectric crystal in order to analyze the binding of acetylcholinesterases from two different species, E. electricus and Drosophila melanogaster, to the immobilized inhibitor. Evaluation of the binding curves allowed the analysis of the binding kinetics. These experiments are fundamental for the development of a (competitive) biosensor for inhibitors of cholinesterase.  相似文献   

5.
AIM: In forensic toxicology it is important to have specific and sensitive analysis for quantification of illicit drugs in biological matrices. This paper describes a quantitative method for determination of cocaine and its major metabolites (ecgonine methyl ester, benzoylecgonine, norcocaine and ethylene cocaine) in whole blood and urine by liquid chromatography coupled with tandem mass spectrometry LC/MS/MS. METHOD: The sample pre-treatment (0.20 g) consisted of acid precipitation, followed by centrifugation and solid phase extraction of supernatant using mixed mode sorbent columns (SPEC MP1 Ansys Diag. Inc.). Chromatographic separation was performed at 30 degrees C on a reverse phase Zorbax C18 column with a gradient system consisting of formic acid, water and acetonitrile. The analysis was performed by positive electrospray ionisation with a triple quadropole mass spectrometer operating in multiple reaction monitoring (MRM) mode. Two MRM transitions of each analyte were established and identification criteria were set up based on the retention time and the ion ratio. The quantification was performed using deuterated internal analytes of cocaine, benzoylecgonine and ecgonine methyl ester. The calibration curves of extracted standards were linear over a working range of 0.001-2.00 mg/kg whole blood for all analytes. The limit of quantification was 0.008 mg/kg; the interday precision (measured by relative standard deviation-%RSD) was less than 10% and the accuracy (BIAS) less than 12% for all analytes in whole blood. Urine samples were estimated semi-quantitatively at a cut-off level of 0.15 mg/kg with an interday precision of 15%. CONCLUSION: A liquid chromatography mass spectrometric (LC/MS/MS) method has been developed for confirmation and quantification of cocaine and its metabolites (ecgonine methyl ester, benzoylecgonine, norcocaine and ethylene cocaine) in whole blood and semi-quantitative in urine. The method is specific and sensitive and offers thereby an excellent alternative to other methods such as GC-MS that involves derivatisation.  相似文献   

6.
Enzyme recognition element-based biosensors are very attractive for biosensor application due to a variety of measurable reaction products arising from a catalytic process. In this study, biosensor recognition elements have been developed via engineer bacterial enzymes (carboxylesterases (CEs)) which will used for narcotic detection because of their role in narcotics metabolism. The modification (insertion of cys-tag) allows the enzyme to bind into a transducer surface of a biosensor which will translate the reaction product into the detection system. The results demonstrate the successful isolation, cloning, expression, and purification of recombinant (pnbA1 and pnbA2), and engineered (pnbA1-cys and pnbA2-cys) bacterial carboxylesterases. Enzyme capability to hydrolyse cocaine into benzoylecgonine and methanol was quantified using HPLC. Both enzymes showed broad maximal activity between pH (8.0, 8.5, and 9.0), PnbA1 temperature stability ranging between (25 and 45 °C); however, PnbA2 stability range was (25–40 °C). Insertion of cys-tag at the N-terminal of the enzyme did not limit entrance to the active site which is located at the base of a cavity with dimensions 20 by 13 by 18 Å, and did not prevent substrate hydrolysis. Bacterial carboxylesterases pnbA1 and pnbA2 mimic hCE1 and not hCE2 in its reaction pathways hydrolysing cocaine into benzoylecgonine and methanol rather than ecgonine methyl ester and benzoic acid. These results are the first experimental evidence confirming the capability of bacterial carboxylesterase to hydrolyse cocaine into its main metabolites, therefore opening up the possibility to use these enzymes in numerous biotechnological applications in addition to a cocaine biosensor.  相似文献   

7.
A high-performance liquid chromatography (HPLC)-mass spectrometry (MS) assay, already validated for opiates and cocaine in meconium, has been re-applied for determination of m- and p-hydroxybenzoylecgonine, using nalorphine as the internal standard. Methodology included an initial extraction from the matrix by methanol and then a solid-phase extraction (SPE). A reversed-phase chromatography was used with a gradient of 1% acetic acid-acetonitrile coupled to atmospheric pressure ionization electrospray-mass spectrometry single ion monitoring mode. This method, validated in the range 0.005-1.00 microg analytes/g meconium, proved useful to identify and quantify these two metabolites in meconium samples, already tested for the presence of cocaine, benzoylecgonine and cocaethylene. A positivity of range of concentrations varied between 0.007 and 0.338 microg/g, confirming the importance of these two hydroxylated derivatives to monitor fetal exposure to cocaine.  相似文献   

8.
In the last several years, interest has increased significantly about the endocannabinoids anandamide and 2-arachidonylglycerol, two lipid messengers that activate cannabinoid receptors. Quantification of these compounds in biological samples presents numerous technical challenges. Because of their low abundance, endocannabinoids are usually quantified by isotope dilution assays using mass spectrometry coupled to either gas chromatography or high-performance liquid chromatography. Although endocannabinoid levels in biological fluids, such as plasma and cerebrospinal fluid, can be directly determined by these techniques, the complex lipid profile of brain tissue samples mandates purification of lipid extracts before GC/MS analysis; this step is not necessary when using HPLC/MS. We have found that when silica gel chromatography is used for endocannabinoid purification, poor recovery and loss of deuterium from the internal standards lead to inaccurate estimation of endocannabinoid levels. By contrast, purification strategies using C(18) solid-phase extraction permits precise and reproducible GC/MS quantification of endocannabinoids in tissue samples.  相似文献   

9.
A procedure based on liquid chromatography-mass spectrometry (LC-MS) is described for determination of 6-monoacetylmorphine, morphine, morphine-3-glucuronide, morphine-6-glucuronide, codeine, cocaine, benzoylecgonine and cocaethylene in meconium using nalorfine as the internal standard. The analytes are initially extracted from the matrix by methanol (6-monoacetylmorphine, morphine, codeine, cocaine, benzoylecgonine and cocaethylene) or 0.01 M ammonium hydrogen carbonate buffer (morphine-3-glucuronide, morphine-6-glucuronide). Subsequently a solid-phase extraction with Bondelut Certify columns (6-monoacetylmorphine, morphine, codeine, cocaine, benzoylecgonine and cocaethylene) or ethyl solid-phase extraction columns (morphine-3-glucuronide, morphine-6-glucuronide) was applied. Chromatography was performed on a C(8) reversed-phase column using a gradient of acetic acid 1%-acetonitrile as a mobile phase. Analytes were determined in LC-MS single ion monitoring mode with atmospheric pressure ionisation-electrospray (ESI) interface. The method was validated in the range 0.005-1.00 microg/g using 1 g of meconium per assay and applied to analysis of meconium in newborns to assess fetal exposure to opiates and cocaine.  相似文献   

10.
Tetranitromethane was used to selectively modify tyrosine residues of a humanized anti-cocaine mAb (h2E2), under development for the treatment of cocaine use disorders. The effect of mild tyrosine nitration on the affinity of cocaine and two high affinity cocaine metabolites, cocaethylene and benzoylecgonine, was assessed using differential scanning fluorimetry to measure ligand affinities via ligand-induced thermal stabilization of the mAb antigen binding region. Nitrated tyrosine residues were identified by mass spectral analysis of thermolysin peptides. One objective was to understand the binding affinity differences observed for these three ligands, which are not explained by the published crystal structure of the h2E2 mAb Fab fragment co-crystalized with benzoylecgonine, since the carboxylic acid of benzoylecgonine that is esterified to form cocaine and cocaethylene is not in contact with the mAb. Importantly, the binding affinity of the cocaine metabolite benzoylecgonine was not decreased by mild nitration, whereas the binding affinities of cocaine and cocaethylene were decreased about two-fold. These ligands differ only in the substituent attached to the carboxylate moiety of the compound, with benzoylecgonine having an unesterified carboxylate, and cocaine and cocaethylene having methyl and ethyl esters, respectively, at this position. The results are consistent with nitration of light chain tyrosine residue 34, resulting in a less favorable interaction with cocaine and cocaethylene carboxylate esters, while not affecting binding of benzoylecgonine. Thus, light chain Tyr34 residue may have molecular interactions with cocaine and cocaethylene not present for benzoylecgonine, leading to the observed affinity differences for these three ligands.  相似文献   

11.
Cocaine and ethanol are frequently used at the same time, resulting in the formation of cocaethylene by transesterification. We studied the capability of high-performance thin-layer chromatography (HPTLC) to simultaneously detect cocaethylene, cocaine and benzoylecgonine in 16 urine specimens of drug addicts, previously tested as positive for benzoylecgonine at immunoenzymatic screening. Accuracy and precision, as well as detection and quantitation limits of the method, were evaluated by comparison with high-performance liquid chromatography (HPLC). HPTLC limit of quantitation was 1.0 μg/ml for the three compounds, whereas HPLC limits were 0.2 μg/ml for benzoylecgonine and cocaine, and 0.1 μg/ml for cocaethylene. The relative standard deviation (RSD) ranged from 1.03 to 12.60% and from 1.56 to 16.6% for intra- and inter-day HPTLC analysis, respectively. In the case of the HPLC method, the RSD for the intra-day precision ranged from 0.79 to 5.05%, whereas it ranged from 1.19 to 10.64% for the inter-day precision. In comparison with HPLC, HPTLC is less expensive and faster, requiring 2–3 h to analyze 10–12 samples on a single plate. In conclusion, HPTLC is suitable for determinations of the three analytes only for samples with high concentrations.  相似文献   

12.
Two methods have been developed for the simultaneous determination of griseofulvin and its major metabolite 6-desmethylgriseofulvin in plasma using electron-capture gas chromatography. The first method was based on the quantitative reversion of the 6-desmethyl metabolite to griseofulvin by diazomethane. Plasma extract was chromatographed both before and after treatment with diazomethane, the former being the measure of griseofulvin and the latter representing the sum of the two compounds. In the second method, plasma extract was treated with diazobutane and griseofulvin and the butylated metabolite were separated by gas chromatography. The sensitivity for griseofulvin was 20 ng/ml by both methods and that for the metabolite was 20 ng/ml and 40 ng/ml by the first and the second method, respectively. The concentrations of the metabolite as well as griseofulvin were determined in dog and human plasma after oral administration of griseofulvin.  相似文献   

13.
A quantitative analytical procedure for the determination of cocaine, benzoylecgonine and cocaethylene and norcocaine in hair has been developed and validated. The hair samples were washed, incubated, and any drugs present were quantified using mixed mode solid-phase extraction and liquid chromatography with tandem mass spectrometric detection in positive atmospheric pressure chemical ionization mode. For confirmation, two transitions were monitored and one ion ratio was determined, which was within 20% of that of the known calibration standards. The monitoring of the qualifying transition and requirement for its presence within a specific ratio to the primary ion limited the sensitivity of the assay, particularly for benzoylecgonine, however, the additional confidence in the final result as well as forensic defensibility were considered to be of greater importance. Even with simultaneous monitoring, the concentrations proposed by the United States Federal guidelines for hair analysis were achieved. The limits of quantitation were 50 pg/mg; the limit of detection was 25 pg/mg. The intra-day precision of the assays at 100 pg/mg (n=5) was 1.3%, 8.1%, 0.8% and 0.4%; inter-day precision 4.8%, 9.2%, 15.7% and 12.6% (n=10) for cocaine, benzoylecgonine, cocaethylene and norcocaine, respectively. The methods were applied to both proficiency specimens and to samples obtained during research studies in the USA.  相似文献   

14.
Extraction of cocaine and benzoylecgonine from coca leaves was performed by focused microwave-assisted extraction (FMAE). Cocaine extraction was optimised with respect to the nature of the extracting solvent, the particle size distribution, the moisture of the sample, the applied microwave power and the radiation time. A central composite design was used to optimise the two latter parameters and to assess the robustness of the extraction method around the best conditions. FMAE generated extracts similar to those obtained by conventional solid-liquid extraction but in a more efficient manner, i.e. 30 s were sufficient to extract cocaine quantitatively from leaves. Analyses of cocaine and benzoylecgonine in coca leaves was carried out by capillary GC-FID and GC-MS for peak identification, as well as by capillary electrophoresis with UV detection.  相似文献   

15.
Cocaine is used by over 20% of women of reproductive age. Although there have been numerous studies focusing on its effects on reproductive processes, none has evaluated its direct effect on preimplantation development. We have investigated the effect of cocaine and its major metabolite, benzoylecgonine, on in vitro preimplantation mouse embryogenesis. One-cell embryos were exposed at the one-, two-, four-, or eight-cell stage for 24 hr to medium containing 0-400 micrograms/ml cocaine or benzoylecgonine and then cultured to the blastocyst stage. Cocaine had its strongest inhibitory effect at the earliest stages of development. At the one- and two-cell stages, there was a significant inhibition of blastocyst formation following exposure to cocaine concentrations of 25-400 micrograms/ml, and at the four-cell stage there was an inhibitory effect at 100 and 400 micrograms/ml cocaine. Benzoylecgonine inhibited the development of embryos to blastocyst only at the one- and two-cell stages, at concentrations of 100-400 micrograms/ml. These findings suggest that cocaine is capable of blocking preimplantation embryogenesis, particularly following exposure at the earliest stages, and that this toxicity may abate as cocaine is biotransformed to benzoylecgonine.  相似文献   

16.
Barkawi LS  Cohen JD 《Nature protocols》2010,5(10):1619-1626
In the emerging field of metabolomics, there is an increasing need for improving sample derivatization reactions for gas chromatographic-mass spectral analysis of metabolites with large numbers of samples. This protocol details the safe direct derivatization of organic acids using diazomethane in a 96-sample format. Diazomethane is a highly reactive gas that readily forms methyl esters with carboxylic functionalities, with minimal side products or nonvolatile reaction residues. However, diazomethane's reactivity and explosive potential make it hazardous to store and work with. In this procedure, diazomethane is generated in situ and used concurrently to methylate up to 96 samples simultaneously, thus reducing concerns about reagent stability and obviating the need for storage of solutions of the highly reactive gas. Once the diazomethane generator has been assembled, processing 96 samples takes 2-3 h using this procedure.  相似文献   

17.
Effect of cocaine and cocaine metabolites on cerebral arteries in vitro   总被引:3,自引:0,他引:3  
J A Madden  R H Powers 《Life sciences》1990,47(13):1109-1114
Cocaine has pronounced peripheral vasoconstrictor effects. Despite the short half life of cocaine in the body these effects are relatively long-lived. The role of cocaine metabolites in vasoconstriction attributed to cocaine has not been reported. We evaluated the contractile ability of cocaine and its major metabolites in isolated cat cerebral arteries. The primary cocaine metabolite, benzoylecgonine was a potent contractile agent, causing a 50% decrease in cross sectional area at 10(-5) M. This was less than caused by serotonin, but greater than caused by norepinehrine. Ecgonine and cocaine were less active contractile agents than was benzoylecgonine, and ecgonine methyl ester was a mild relaxant.  相似文献   

18.
为了提高谷氨酰胺转胺酶的纯度和扩展在医药领域的应用,探索了一种适合工业化生产的、安全高效的微生物谷氨酰胺转胺酶纯化方法。轮枝链霉菌发酵后,经离心10 000 r/min 4℃除去菌体,调节发酵液电导率至4.1mS/cm和pH6.0后,以直线流速60cm/h通过SP Sepharose FF阳离子交换层析柱对目的蛋白高 选择性和高载量地捕获,再通过phenyl sepharose 6 FF(high sub)疏水层析柱进行精细纯化。纯化后经SDS-PAGE鉴定纯度达到95%以上,HPLC分析纯度> 99%。鲎试剂测定内毒素含量为0.013EU/ml,达到中国药典中血制品要求的低于0.15EU/ml标准。  相似文献   

19.
B Mets  J Diaz  E Soo  S Jamdar 《Life sciences》1999,65(12):1317-1328
We have compared the pharmacokinetics of bolus dose cocaine administration with that of its three most important metabolites; norcocaine, ecgonine methylester, and benzoylecgonine and assessed whether kinetics are dose dependent at two equimolar doses equivalent to cocaine hydrochloride 2.5 and 5 mg/kg respectively. Forty-nine male Sprague-Dawley rats were randomly divided into 8 groups to receive i.v. either high (14.7 umol/kg) (HI) or low (7.3 umol/kg) (LO) bolus doses of cocaine or one of its metabolites. Arterial blood samples for cocaine and metabolite analysis were taken repetitively over the next 3 h. Equimolar bolus doses of these congeners showed biexponential plasma concentration decay curves which were fitted to a two compartment model and subjected to noncompartmental analysis. The plasma concentration time profiles were significantly different for the HI and LO doses administered for each congener. The elimination half-lives of cocaine and norcocaine were similar (28-33 min), that for ecgonine methylester (60-71 min) was approximately twice this and for benzoylecgonine was 40-44 min. Cocaine clearance (155-158 ml/kg/min) was found to be in the range found in other rat studies. Ecgonine methylester clearance and benzoylecgonine clearance were found to be one quarter and one eighth of this value respectively. The pharmacokinetic profile of these congeners was not dose dependent when the two doses administered were compared.  相似文献   

20.
A positive chemical ionization gas chromatography-mass spectrometric method was validated to simultaneously quantify drugs and metabolites in skin collected after controlled administration of methamphetamine, cocaine, and codeine. Calibration curves (2.5-100 ng/skin biopsy) for methamphetamine, amphetamine, cocaine, norcocaine, benzoylecgonine, cocaethylene, norcocaethylene, anhydroecgonine methyl ester, morphine, codeine, and 6-acetylmorphine (5-100 ng/skin biopsy for ecgonine methyl ester and ecgonine ethyl ester) exhibited correlation coefficients >0.999 and concentrations +/-20% of target. Intra- and inter-run precisions were <10%. This procedure should be useful for postmortem analysis; data are included on drug concentrations in skin after controlled drug administration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号