首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
In this paper the factors influencing treatment performance of subsurface flow constructed wetlands (SSF wetlands) treating aquaculture effluents were identified and quantified. The financial impact of advanced aquaculture effluent treatment with SSF wetlands was calculated.It is the first long-term, commercial-scale trial of SSF wetland treatment for effluents from intensive trout farming, a highly diluted effluent at very high flow rates (mean total phosphorous concentration 0.34 mg L?1 at 14.3 L s?1). The 12-month survey provided the opportunity to generate calculation fundamentals for the commercial application of SSF wetlands for aquaculture. Treatment efficiencies of up to 75–86% for total ammonia nitrogen (TAN), biological oxygen demand (BOD5) and total suspended solids (TSS) were achieved. The daily area retention rate per square meter wetland area was between 2.1 and 4.5 g for TAN and between 30 and 98 g for TSS.The performance of the six wetland cells comprising three replicated hydraulic loading groups (14.5, 6.9, 3.3 m3 m?2 day?1) was monitored, offering the possibility to identify factors influencing treatment efficiency through multifactor analysis. These factors turned out to be nutrient inflow concentration, hydraulic loading rate and accumulation of TSS within the wetland bed, the only time-dependent factor. Factors such as vegetation period and fish harvesting were shown to be of significant but negligible importance.Inflow nutrient concentration is determined by production intensity, husbandry conditions, feed quality and any pre-treatment of effluent. Hydraulic load is determined by the space and budget available for SSF construction. TSS accumulation in the wetland is influenced by pre-treatment of the solid fraction prior to the wetland and determines the wetland service lifetime.From these factors the expenses of commercial wetland application can be estimated, leading to a cost increase around €0.20 kg?1 fish produced (less than 10% of production costs) and therefore confirm the commercial feasibility of SSF wetland treatment.  相似文献   

2.
The use of surface flow (SFCWs) and subsurface flow constructed wetlands (SFCWs) for the treatment of combined sewer overflows was assessed at pilot scale. Synthetic wastewater was applied in three batches with decreasing concentrations to mimic concentration profiles that are obtained in the field during overflow events. Three simulated combined sewer overflows were applied on each wetland. Composite water samples (60 in total) were taken for a period of 8 days to study the removal of total nitrogen (Ntot), NH4–N, NO3–N, total COD (CODtot) and total phosphorus. Redox potential, which was monitored at various locations along the wetlands, was more negative in the SSFCWs. In general, removal occurred faster in the SSFCWs and the final concentrations were lower. The removal of Ntot was only 36.6 ± 3.3% in the SFCWs due to nitrification-limiting conditions. The conditions in the SSFCWs, in contrast, seemed to promote Ntot removal (removal efficiency 96.7 ± 1.9%). The removal of P was hampered in both wetland types by reducing conditions. P that was initially removed was released again from the substrates later on. First-order removal rate constants were derived for the removal of both CODtot (SSFCWs: 1.1 ± 0.3 m d?1; SFCWs: 0.17 ± 0.06 m d?1) and Ntot (SSFCWs: 0.4 ± 0.1 m d?1; SFCWs: 1.7 ± 0.5 m d?1).  相似文献   

3.
Many factors can influence the improvement of water quality in surface-flow constructed wetlands (SFW). To test if water quality was improved, especially in nutrient and salt content, after passage through SFW, 11 wetland plots of various sizes (50, 200, 800 and 5000 m2) were established within constructed wetlands on agricultural soils in the Ebro River basin (NE Spain) that had been affected by salinization. A set of 15 water quality parameters (e.g., nutrients, salts, sediments, and alkalinity) was obtained from samples collected at the inflow and outflow of the wetlands during the first 4 years after the wetlands were constructed. NO3-N retention rates were as high as 99% in the largest (5000 m2) wetlands. After 4 years, total phosphorus was still being released from the wetlands but not salts. Over the same period, in small wetlands (50, 200, and 800 m2), retention rate relative to the input of NO3-N increased from 40% to almost 60%. Retention of NO3-N amounted to up to 500 g N m?2 per year, for an average load concentration at inflow of ~20 mg l?1. Release of Na+ declined from 16% to 0–2% by volume, for an average load concentration at inflow of ~70 mg l?1. At the current retention rate of NO3-N (76–227 g m?2 per year), 1.5–4% of the catchment should be converted into wetlands to optimize the elimination of NO3-N.  相似文献   

4.
One method for managing livestock-wastewater N is the use of treatment wetlands. The objectives of this study were to (1) assess the magnitude of denitrification enzyme activity (DEA) in the suspended sludge layers of bulrush and cattail treatment wetlands, and (2) evaluate the impact of nitrogen pretreatment on DEA in the suspended sludge layer. The study used four wetland cells (3.6 m × 33.5 m) with two cells connected in series. Each wetland series received either untreated or partially nitrified swine wastewater from a single-cell anaerobic lagoon. The DEA of the suspended sludge layers of the constructed wetlands was measured by the acetylene inhibition method. The control DEA treatment for the sludge layer had a mean rate of 18 μg N2O-N g?1 sludge h?1. Moreover, the potential DEA (nitrate-N and glucose-C added) mean was very large, 121 μg N2O-N g?1 sludge h?1. These DEA rates are consistent with the previously reported high levels of nitrogen removal by denitrification from these wetlands, especially when the wastewater was partially nitrified. Stepwise regression using distance within the wetland, wastewater nitrate, and wastewater ammonia explained much of the variation in DEA rates. In both bulrush and cattail wetlands, there were zones of very high potential DEA.  相似文献   

5.
Integration of partial nitrification (nitritation) and anaerobic ammonium oxidation (anammox) in constructed wetlands creates a sustainable design for nitrogen removal. Three wetland treatment systems were operated with synthetic wastewater (60 mg NH3–N L?1) in a batch mode of fill – 1-week reaction – drain. Each treatment system had a surface flow wetland (unplanted, planted, and planted plus aerated, respectively) with a rooting substrate of sandy loam and limestone pellets, followed by an unplanted subsurface flow wetland. Meanwhile, three surface flow wetlands with a substrate of sandy loam and pavestone were operated in parallel to the former surface flow wetlands. Influent and effluent were monitored weekly for five cycles. Aeration reduced nitrogen removal due to hindered nitrate reduction. Vegetation maintained pH near neutral and moderate dissolved oxygen, significantly improved ammonia removal by anammox, and had higher TN removal due to coexistence of anammox and denitrification in anaerobic biofilm layers. Nitrite production was at a peak at the residence time of 4–5 d. Relative to pavestone, limestone increased the nitrite mass production peak by 97%. The subsurface flow wetlands removed nitrogen via nitritation and anammox, having an anammox activity of up to 2.4 g N m?3 d?1 over a startup operation of two months.  相似文献   

6.
In Egypt, disposing of partially treated or untreated domestic and industrial wastewater into agricultural drains deteriorates their water quality. A growing interest in effective low-cost treatment of polluted water and wastewater has resulted in many studies on constructed wetlands.This study evaluates free water surface constructed wetlands (by far the largest application project is named “Lake Manzala Engineered Wetland [Egypt]”) utilized to improve the water quality in Bahr El Baqar drain, which is located at the northeastern edge of the Nile Delta. This drain discharges its water into Manzala Lake, which in turn has many fishing activities and is connected to the Mediterranean Sea. The full capacity of the constructed wetland system is 25,000 m3/day. Three various flow rate wetlands were investigated; five wetland beds of high flow rate of 0.344 m3/m2-day, five wetland beds of low flow rate of 0.048 m3/m2-day and reciprocated cells of flow of 500 m3/day.The concentrations of different contaminants along the constructed wetlands system were measured to determine the treatment efficiency. The effluent was compared with the Egyptian standards of water quality in agricultural drains (Law 48/1982). Due to the high percentage of the agricultural water drain, the concentrations of contaminants in the influent were relatively low. The percentages of removal for the different contaminants were BOD5: 52%, COD: 50%, TSS: 87%, TDS: 32%, NH4-N: 66%, PO4: 52%, Fe: 51%, Cu: 36%, Zn: 47% and Pb: 52%. The natural vegetation considerably increased the value of dissolved oxygen in the treated effluent. There were little differences in the removal efficiency between the high and low flow rates beds in the system.  相似文献   

7.
In this study, a newly developed combined natural wastewater treatment system was used for the first time in the Village of Ileydagi, which has a population of 313 situated in the reservoir of Lake Egirdir, the second largest freshwater lake in Turkey. The combined treatment system consists of a combination of buried sand filtration (BSF) and buried subsurface flow constructed wetland (BSSF-CW) systems. The total area of the BSF system is 582 m2 and that of the BSSF-CW system is 1352 m2. Performance of the combined treatment system was 5% higher during the summer period than during the winter months. The average removal values of the combined system observed for a 14-month period were as follows: Biological Oxygen Demand (BOD) 97%, total nitrogen (TN) 85%, and total phosphorus (TP) 69%. There is a strong correlation (0.81–0.97) between the loading and removal rates (g/m2 d). This correlation is also statistically important. The results indicate that the novel sand filtration and constructed wetland treatment system is an optimal solution to the wastewater problems of small settlements.  相似文献   

8.
The treatment capacity of constructed wetlands is expected to be high in tropical areas because of the warm temperatures and the associated higher rates of microbial activity. A pilot scale horizontal subsurface flow constructed wetland system filled with river sand and planted with Phragmites vallatoria (L.) Veldkamp was set up in the southern part of Vietnam to assess the treatment capacity and the removal rate kinetics under tropical conditions. The system received municipal wastewater at four hydraulic loading rates (HLRs) of 31, 62, 104 and 146 mm day?1. Removals of TSS, BOD5 and COD were efficient at all HLRs with mean removal rates of 86–95%, 65–83% and 57–84%, respectively. Removals of N and P decreased with HLRs and were: NH4-N 0–91%; TN 16–84% and TP 72–99%. First-order area-based removal rate constants (k, m year?1) estimated from sampling along the length of the wetland from inlet to outlet at the four HLRs were in the range of 25–95 (BOD5), 22–30 (COD), 31–115 (TSS), 5–24 (TN and TKN) and 41–84 (TP) at background concentrations (C*) of 5, 10, 0, 1.5 and 0 mg L?1, respectively. The estimated k-values should not be used for design purposes, as site-specific differences and stochastic variability can be high. However, the study shows that domestic wastewater can be treated in horizontal subsurface flow constructed wetland systems to meet even the most stringent Vietnamese standards for discharge into surface waters.  相似文献   

9.
This paper presents a simple method for evaluating the degree of clogging of subsurface flow constructed wetlands based on saturated hydraulic conductivity measurements. The method was applied to two full-scale wetlands located inside the wastewater treatment plants of two small villages (2000 PE) in the province of Lleida, Catalonia, Spain. In addition, to gain an insight into the mechanisms that lead to clogging, other measurements and analyses were carried out including the quantification of accumulated solids and belowground plant biomass. X-ray diffraction analyses were carried out to evaluate the mineral composition of accumulated sludge and granular medium. Hydraulic conductivity measurements and samples for solids analyses were taken along two transects that spanned the length of each wetland. Patterns for hydraulic conductivity were the same in both wetlands: very low values from the inlet zone to the middle (<20 m/d), clearly higher from the middle to 4/5 of the length (600–800 m/d), and lower very near the outlet (40–70 m/d). These results indicate that the first half of the length of both wetlands is highly clogged. Total solids (TS) were generally higher near the inlet than the outlet (TSinlet = 3–15 kg/m2; TSoutlet = 1–9 kg/m2). Belowground plant biomass values were variable and did not show a clear pattern. In both wetlands the mineral fraction of the solids represented more than 75% of TS in most of the samples. X-ray diffraction analyses showed that the mineral composition of the solids coincided with that of the granular medium (mostly calcite and quartz). The proposed method based on hydraulic conductivity measurements is straightforward to use, does not require costly devices and allows to successfully evaluate the degree of clogging.  相似文献   

10.
Temperate wetlands in the Northern Hemisphere have high long-term carbon sequestration rates, and play critical roles in mitigating regional and global atmospheric CO2 increases at the century timescale. We measured soil organic carbon (SOC), total nitrogen (TN), and total phosphorus (TP) from 11 typical freshwater wetlands (Heilongjiang Province) and one saline wetland (Jilin Province) in Northeast China, and estimated carbon sequestration rates using 210Pb and 137Cs dating technology. Effects of climate, net primary productivity, and nutrient availability on carbon sequestration rates (Rcarbon) were also evaluated. Chronological results showed that surface soil within the 0–40 cm depth formed during the past 70–205 years. Soil accretion rates ranged from 2.20 to 5.83 mm yr−1, with an average of 3.84 ± 1.25 mm yr−1 (mean ± SD). Rcarbon ranged from 61.60 to 318.5 gC m−2 yr−1 and was significantly different among wetland types. Average Rcarbon was 202.7 gC m−2 yr−1 in the freshwater wetlands and 61.6 gC m−2 yr−1 in the saline marsh. About 1.04 × 108 tons of carbon was estimated to be captured by temperate wetland soils annually in Heilongjiang Province (in the scope of 45.381–51.085°N, 125.132–132.324°E). Correlation analysis showed little impact of net primary productivity (NPP) and soil nutrient contents on Rcarbon, whereas climate, specifically the combined dynamics of temperature and precipitation, was the predominant factor affecting Rcarbon. The negative relationship observed between Rcarbon and annual mean temperature (T) indicates that warming in Northeast China could reduce Rcarbon. Significant positive relationships were observed between annual precipitation (P), the hydrothermal coefficient (defined as P/AT, where AT was accumulative temperature ≥10 °C), and Rcarbon, indicating that a cold, humid climate would enhance Rcarbon. Current climate change in Northeast China, characterized by warming and drought, may form positive feedbacks with Rcarbon in temperate wetlands and accelerate carbon loss from wetland soils.  相似文献   

11.
《Ecological Engineering》2006,26(3):272-282
A full-scale constructed wetlands system with a total area of 80 ha and treatment capability of 2.0 × 104 m3 d−1 was completed in October 1998 in Rongcheng, Shandong Province, China. To evaluate wastewater treatment effectiveness and seasonal performance of the system, water samples were collected and analyzed from January 1999 to December 2004. Comparison of mean inlet and outlet concentrations showed that the constructed wetland system could effectively reduce the output of SS (71.8 ± 8.4%), BOD5 (70.4 ± 9.6%), COD (62.2 ± 10.1%), total coliform (99.7%) and fecal coliform (99.6%). However, the percent reduction of ammonia nitrogen was relatively low (40.6 ± 15.3%), and total phosphorus showed the least efficient reduction (29.6 ± 12.8%). BOD5, COD, ammonia nitrogen, and total phosphorus removal efficiencies displayed seasonal variations. BOD5 and COD removal was more efficient in spring and summer than in autumn and winter whereas ammonia nitrogen and total phosphorus removal was more efficient in summer and autumn than in spring and winter. Annual variation analysis shows that COD, BOD5, and ammonia nitrogen reduction efficiencies increased from 1999 to 2004. In contrast, mean total phosphorus reduction efficiency did not change from 2001 to 2002 and began to decrease from 2003 onwards.  相似文献   

12.
Nitrate-nitrogen retention in wetlands in the Mississippi River Basin   总被引:1,自引:0,他引:1  
《Ecological Engineering》2005,24(4):267-278
Nitrate-nitrogen retention as a result of river water diversions is compared in experimental wetland basins in Ohio for 18 wetland-years (9 years × 2 wetland basins) and a large wetland complex in Louisiana (1 wetland basin × 4 years). The Ohio wetlands had an average nitrate-nitrogen retention of 39 g-N m−2 year−1, while the Louisiana wetland had a slightly higher retention of 46 g-N m−2 year−1 for a similar loading rate area. When annual nitrate retention data from these sites are combined with 26 additional wetland-years of data from other wetland sites in the Basin Mississippi River (Ohio, Illinois, and Louisiana), a robust regression model of nitrate retention versus nitrate loading is developed. The model provides an estimate of 22,000 km2 of wetland creation and restoration needed in the Mississippi River Basin to remove 40% of the nitrogen estimated to discharge into the Gulf of Mexico from the river basin. This estimated wetland restoration is 65 times the published net gain of wetlands in the entire USA over the past 10 years as enforced by the Clean Water Act and is four times the cumulative total of the USDA Wetland Reserve Program wetland protection and restoration activity for the entire USA.  相似文献   

13.
Constructed treatment wetlands have served the City of Columbia, MO, for fourteen years. Four free water surface wetland units in series, comprised of 23 cells, are an addition to the activated sludge wastewater treatment plant, for the purpose of added biochemical oxygen demand (BOD) and total suspended solids (TSS) control. The system operates year-round, and supplies water to the Eagle Bluffs Conservation Area for wetland maintenance. The cattail wetlands processed an average of 57,000 m3/d, at a water depth of 20 cm. The resulting detention time was approximately 2 days, and the hydraulic loading was 13 cm/d. Water temperatures were warm leaving the treatment plant and in the wetlands in winter, because of the short detention. The period of record average carbonaceous biochemical oxygen demand (CBOD) leaving the wetlands was 5.0 mg/L, and the TSS was 14.7 mg/L. Dissolved oxygen was depressed in summer, likely because of the high sediment demand. Nutrient concentrations were only minimally reduced, total nitrogen (TN) by 22% and total phosphorus (TP) by 6%. However, load reductions were maximal, 98 t/yr for nitrogen, and 3.6 t/yr for phosphorus. Fecal coliforms were reduced by 98%, and E. coli by 95%. First order rate coefficients were high for CBOD (64 m/yr), nitrate (61 m/yr) and organic nitrogen (42 m/yr), but relatively low for ammonia (8 m/yr) and phosphorus (5.7 m/yr). Nitrogen removal was strongly affected by vegetative uptake. Sediment accretion in the wetland inlets was substantial, at 1.6 cm/yr in the inlets to the upstream wetland units. Muskrats caused vegetation damage, and waterfowl use was high in winter, causing TSS excursions.  相似文献   

14.
A horizontal subsurface flow (HSSF) and a free water surface flow (FWSF) constructed wetlands (4 m2 of each) were set up on the campus of Harran University, Sanliurfa, Turkey. The main objective of the research was to compare the performance of two systems to decide the better one for future planning of wastewater treatment system on the campus. Both of the wetland systems were planted with Phragmites australis and Canna indica. During the observation period (10 months), environmental conditions such as pH, temperature and total chemical oxygen demand (COD), soluble COD, total biochemical oxygen demand (BOD), soluble BOD, total suspended solids (TSS), total phosphate (TP), total nitrogen (TN) removal efficiencies of the systems were determined. According to the results, average yearly removal efficiencies for the HSSF and the FWSF, respectively, were as follows: total COD (75.7% and 69.9%), soluble COD (85.4% and 84.3%), total BOD (79.6% and 87.6%), soluble BOD (87.7% and 95.3%), TN (33.2% and 39.4%), and TP (31.5% and 6.5%). Soluble COD and BOD removal efficiencies of both systems increased gradually since the start-up. After nine months of operation, above 90% removal of organic matters were observed. The treatment performances of the HSSF were better than that of the FWSF with regard to the removal of suspended solids and total COD at especially high temperatures. In FWSF systems, COD concentrations extremely exceeded the discharge limit values due to high concentrations of algae in spring months.The performance of the two systems was modelled using an artificial neural network-back-propagation algorithm. The ANN model was competent at providing reasonable match between the measured and the predicted concentrations of total COD (R = 0.90 for HSSF and R = 0.96 for FWSF), soluble COD (R = 0.90 for HSSF and R = 0.74 for FWSF) and total BOD (R = 0.94 for HSSF and R = 0.84 for FWSF) in the effluents of constructed wetlands.  相似文献   

15.
《Ecological Engineering》2005,24(3):219-232
Water pollution by agriculture can include inappropriately managed dairy farmyard dirty water. In Ireland, dairy farmyard dirty water includes farmyard runoff, parlour washings, and silage/farmyard manure effluents. The objectives of this study were to determine (i) the quality and quantity of dirty water generated at a farm-scale and (ii) the seasonal effectiveness of a constructed wetland to treat farmyard dirty water. The wetland system was 4800 m2 in area and treated dirty water from a 42-cow organic dairy unit with an open yard area of 2031 m2. Monthly dirty water inflow rate to the wetland ranged between 3.6 and 18.5 m3 d−1. Farmyard dirty water accounted for 27% of hydrological inputs to the wetland, whereas rainfall on wetland, along with wetland bank inflows accounted for 45 and 28%, respectively. Farmyard dirty water quality and quantity did not vary with season. Yearly mass loads discharged to the wetland were 47 ± 10 kg yr−1 of soluble reactive phosphorus (SRP), 128 ± 35 kg yr−1 of NH4+, 5484 ± 1433 kg yr−1 of organic material as measured by five-day biological oxygen demand (BOD5), and 1570 ± 465 kg yr−1 of total suspended solids (TSS). Phosphorus retention by the wetland varied with season (5–84%) with least amounts being retained during winter.  相似文献   

16.
Anoxic subsurface flow (SSF) constructed wetlands were evaluated for denitrification using nitrified wastewater. The treatment wetlands utilized a readily available organic woodchip-media packing to create the anoxic conditions. After 2 years in operation, nitrate removal was found to be best described by first-order kinetics. Removal rate constants at 20 °C (k20) were determined to be 1.41–1.30 d?1, with temperature coefficients (θ) of 1.10 and 1.17, for planted and unplanted experimental woodchip-media SSF wetlands, respectively. First-order removal rate constants decreased as length of operation increased; however, a longer-term study is needed to establish the steady-state values. The hydraulic conductivity in the planted woodchip-media SSF wetlands, 0.13–0.15 m/s, was similar to that measured in an unplanted gravel-media SSF control system.  相似文献   

17.
The aim of this paper is to evaluate and compare broadleaved cattail (Typha latifolia L.) biomass production and the nitrogen (N) and phosphorus (P) content in phytomass in three treatment wetland systems and to propose suitable areas for treatment wetlands in Estonia for raw material production. The biomass samples (roots/rhizomes, shoots with leaves and spadixes) and litter were collected from 1 m × 1 m plots—15 plots in the Tänassilma semi-natural wetland, 15 plots in the Põltsamaa free water surface (FWS) constructed wetland (CW), and 10 plots in the Häädemeeste FWS CW. The average aboveground biomass of T. latifolia varied from 0.37 to 1.76 kg DW m?2 in autumn and from 0.33 to 1.38 kg DW m?2 in winter. The greatest average nitrogen (22,950 mg N kg?1) concentration was found in spadixes in 2002, and the phosphorus (6500 mg P kg?1) concentration was measured in roots–rhizomes in 2003. Average standing stock of nitrogen and phosphorus was higher in aboveground than belowground phytomass. In FWS CWs with high hydraulic and nutrient loadings, however, the harvesting of aboveground biomass is not an effective means for the removal of nutrients. Cattail biomass is a valuable insulation material, whereas the fibre from spadixes mixed with clay gives elasticity to clay plasters. According to our estimates, about 5412 km2 could be used for Typha cultivation in Estonia.  相似文献   

18.
Five emergent plant species were compared for their effectiveness in treating contaminants in a wetland system constructed on a military base in El Salvador. The system consisted of the subsurface flow (SSF), open water (OW) and free surface flow (SF) wetlands with a combined flow capacity of up to 151.4 m3 d?1. Reliability and consistent performance in extreme conditions, such as those occurring during the tropical dry or wet seasons were important evaluation criteria. The discontinuous flow patterns typical of tropical climates necessitated the use of water balance calculations using climatic data such as rainfall and evapotranspiration. System characterization was achieved by computation of daily input and output mass loading rates for each individual constituent. Results suggest that Phragmites and Brachiaria were the most effective plants in SSF wetland. Brachiaria provided the added benefit of serving as a source of fodder and proved proficient, with N and P uptakes of 1.5–3.14% and 0.17–0.25% per dry plants’ biomass, respectively. Typha yielded the highest dry season removal efficiency within the SF (BOD5: 80.78 ± 9.35%, COD: 65.18 ± 19.6%, TN: 58.59 ± 19.3%, oil and grease: 78.34 ± 10.55%, total dissolved phosphorus: 66.5 ± 20.7%). PhragmitesTypha treatment subset performed better year-round than either ThaliaThalia or BrachiariaCyperus. Evaluated plants were capable of surviving and proliferating in extreme tropical climates.  相似文献   

19.
Knowledge regarding the fate, accumulation and distribution of arsenic inside constructed wetlands is still insufficient. Based on a complete mass balance analysis, the aim of this study was to investigate the fate and distribution of As in distinct wetland compartments and different segments along the wetland gradient. Experiments were carried out in laboratory-scale wetland systems, two planted with Juncus effusus and one unplanted, using an As-containing artificial wastewater. The obtained results revealed that the planted wetlands have a substantially higher As-mass retention capacity (59–61% of the total As inflow) than wetlands without plantation (only 44%). However, different loads of organic carbon within the inflowing artificial wastewater showed no remarkable influence on As-mass retention in the planted wetlands. Nearly 47–52% of the total inflowing As mass was found to be retained within the first half of the planted wetlands and this retention decreased step by step along the flow path. In contrast, only 28% of the total inflowing As mass was retained within the first half of the unplanted wetland. In general, a different fate and distribution of As was observed inside the planted and unplanted wetlands. Higher As concentrations were exhibited by the plant roots (51.5–161.5 mg As kg?1 dry wt.) compared to the shoots (1.1–6.4 mg As kg?1 dry wt.). Analysis of the total As-mass balance in the planted wetlands revealed that nearly 44–49% of the total inflowing As was recovered or concentrated within the plant roots, only 1% was sequestered within the plant shoots, 7–10% were entrapped or deposited within the gravel bed sediments, 2–3% were retained in the standing pore water, 39–41% were flushed out as outflow and the remaining 1–2% is still considered to be unaccountable. Total As accumulation in the plant shoots made a small contribution to the mass balance, and plant root biomass was found to be the most important compartment for As retention. In contrast, nearly 11% of the total inflowing As were found in the sediment, 2% in the standing pore water, 57% in the outflow and a substantially higher portion (nearly 30%) remained unaccountable in the unplanted bed, which might be released as volatile As compounds or lost from the system due to various unknown reasons. The results indicate that plants have a remarkable effect on As retention and stability of already retained As; hence planted wetlands might be a suitable option for treating As-contaminated wastewater.  相似文献   

20.
The ability of riverine ecosystems to retain nutrients depends on different hydrological, chemical and biological conditions including exchange processes between streams and wetlands. We investigated nutrient retention in a stream wetland complex on the time scale of daily hydrological exchange between both systems. Daily mass balances of NO3-N, NH4-N, TP and SRP were calculated with data obtained by two automated measurement stations in a stream reach upstream and downstream of a wetland. The pattern of hydrological exchange between stream and wetland was used to classify characteristic hydrological periods like floods, base and low flows. The nutrient retention function of the stream wetland complex varied considerably during phases of similar hydrologic conditions. Despite re-wetting measures in the wetland, an overall net export of all nutrients except for NH4-N characterised the whole growing season. Nitrate retention occurred during summer flood (retention in the wetland, 23 kg NO3-N d?1, 17% of the input load) and low flow (retention in the stream, 1 kg NO3-N d?1, 2% of the input load). TP retention during summer could be assigned to sedimentation (0.7 kg TP d?1, 7% during flooding in the wetland, 0.2 kg TP d?1, 4% during low flow in the stream). SRP retention was only intermittent. We concluded that the nutrient retention of streams and wetlands can only be optimised by restoration measures that regard both systems as one functional unit in terms of nutrient retention.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号