首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 703 毫秒
1.
In a prospective audit of the obstetric management of 1210 consecutive deliveries the association was investigated between the need for operative delivery for fetal distress during labour and the condition of the newborn infant. Operative delivery was performed for only 11.5% of the newborn infants with severe acidosis at birth (umbilical artery pH less than 7.12, base deficit greater than 12 mmol (mEq)/1), 24.1% of those with an Apgar score less than 7 at one minute, and 15.8% of those with both severe acidosis and a one minute Apgar score less than 7. Most of the infants delivered operatively were in a vigorous condition at birth and did not have severe acidosis. Fetal blood sampling was done in 4.0% of labours. As none of the fetal blood values were less than 7.20 and only three of the infants sampled in utero suffered severe acidosis at birth, fetal blood sampling would have had to be performed much more often to provide a useful guide to metabolic state at birth. While the large majority of "at risk" fetuses had continuous fetal heart rate monitoring in labour, this had not been provided in 48.7% of the labours of infants with severe acidosis, 38.7% of infants with a one minute Apgar score less than 7, and 47.4% of infants with both severe acidosis and a one minute Apgar score less than 7. Continuous fetal heart rate monitoring was associated with a much higher incidence of operative delivery for fetal distress than was intermittent fetal heart rate auscultation. These results suggest an urgent need to review present methods for assessing the intrapartum condition of the fetus, making the diagnosis of fetal distress, and assessing the condition of the infant at birth.  相似文献   

2.
OBJECTIVE--To compare effectiveness of different methods of monitoring intrapartum fetal heart rate. DESIGN--Prospective randomised controlled trial. SETTING--Referral maternity hospital, Harare, Zimbabwe. SUBJECTS--1255 women who were 37 weeks or more pregnant with singleton cephalic presentation and normal fetal heart rate before entry into study. INTERVENTIONS--Intermittent monitoring of fetal heart rate by electronic monitoring, Doppler ultrasound, use of Pinard stethoscope by a research midwife, or routine use of Pinard stethoscope by attending midwife. MAIN OUTCOME MEASURES--Abnormal fetal heart rate patterns, need for operative delivery for fetal distress, neonatal mortality, Apgar scores, admission to neonatal unit, neonatal seizures, and hypoxic ischaemic encephalopathy. RESULTS--Abnormalities in fetal heart rate were detected in 54% (172/318) of the electronic monitoring group, 32% (100/312) of the ultrasonography group, 15% (47/310) of the Pinard stethoscope group, and 9% (28/315) of the routine monitoring group. Caesarean sections were performed for 28% (89%), 24% (76), 10% (32), and 15% (46) of the four groups respectively. Neonatal outcome was best in the ultrasonography group: hypoxic ischaemic encephalopathy occurred in two, one, seven, and 10 cases in the four groups respectively; neonatal seizures occurred only in the last two groups (six and nine cases respectively); and deaths occurred in eight, two, five, and nine cases respectively. CONCLUSIONS--Abnormalities in fetal heart rate were more reliably detected by Doppler ultrasonography than with Pinard stethoscope, and its use resulted in good perinatal outcome. The use of relatively cheap ultrasound monitors should be further evaluated and promoted in obstetric units caring for high risk pregnancies in developing countries with scarce resources.  相似文献   

3.
The use of continuous fetal heart rate (FHR) and uterine pressure monitoring in the chimpanzee (Pan troglodytes) by external Doppler transducer and tocodynamometer is described in 1) the routine obstetrical assessment of fetal well-being, 2) oxytocin challenge (stress) testing (OCT) and non-stress testing (NST) for the diagnosis of in utero fetal distress, and 3) induction of labor by intravenous oxytocin infusion, by surgical rupture of the chorio-amniotic membranes (amniotomy), or by a combination of these techniques, as an alternative to Caesarean section for clinical, managemental, or experimental purposes. FHR traces were analyzed during a total of 57 term pregnancies for three basic characteristics: baseline rate, variability, and periodic pattern. Results indicated that continuous FHR monitoring in the chimpanzee can provide a valuable tool for fetal assessment and management of labor in any attempt to reduce the unacceptably high annual incidence of perinatal and neonatal infant mortality reported in the U.S.  相似文献   

4.
目的:探讨双胎妊娠一胎宫内死亡的原因及处理方法。方法:对本院2013年1月~2017年6月住院分娩的双胎妊娠一胎宫内死亡的病例进行回顾性分析。结果:双胎妊娠一胎宫内死亡28例,占同期双胎分娩的1.63%,占同期双胎胎盘送检的4.33%。6例孕28周,14例孕28~34周,8例孕周34周。全部孕产妇均无出血倾向或发生凝血功能障碍。产妇年龄23~45周岁,平均31.3周岁;初产妇23人,经产妇5人。应用辅助生殖技术受孕5例,自然受孕23例;剖宫产7例,顺产21例;确诊一胎儿死亡时间为孕12周余~34周余。主要致死原因为脐带因素13例次(46.43%),胎盘因素12例次(42.86%),双胎输血综合征及纸样胎共5例次(17.86%),胎儿畸形4例次(18.18%)。结论:孕中晚期双胎之一胎儿宫内死亡妊娠不足34周,应在密切监护母胎情况下行期待治疗,单绒毛膜囊双胎34周后可以分娩,双绒毛膜囊双胎可妊娠至36周。  相似文献   

5.
Fetal electrocardiogram (FECG) signal contains potentially precise information that could assist clinicians in making more appropriate and timely decisions during labor. The ultimate reason for the interest in FECG signal analysis is in clinical diagnosis and biomedical applications. The extraction and detection of the FECG signal from composite abdominal signals with powerful and advance methodologies are becoming very important requirements in fetal monitoring. The purpose of this review paper is to illustrate the various methodologies and developed algorithms on FECG signal detection and analysis to provide efficient and effective ways of understanding the FECG signal and its nature for fetal monitoring. A comparative study has been carried out to show the performance and accuracy of various methods of FECG signal analysis for fetal monitoring. Finally, this paper further focused some of the hardware implementations using electrical signals for monitoring the fetal heart rate. This paper opens up a passage for researchers, physicians, and end users to advocate an excellent understanding of FECG signal and its analysis procedures for fetal heart rate monitoring system.  相似文献   

6.
Fetal cardiac activity was monitored with an external ultrasound transducer in two patients with clinical class III heart disease due to severe mitral stenosis complicated by pulmonary hypertension, undergoing open heart surgery with cardiopulmonary bypass in the 2nd trimester of pregnancy. Fetal distress was detected in one patient, who had mitral valvuloplasty, and was corrected by increasing the rate of blood flow, and the other patient had a mitral valve replacement but no fetal distress was noted. The postoperative course of both mothers and fetuses was uneventful.  相似文献   

7.
To improve detection of fetal distress, we examined whether increased fetal sympathetic activity during repeated episodes of asphyxia decreases skin blood flow, which can be monitored by recording transcutaneous PO2. Sympathetic activity was assessed by relating catecholamine concentrations in the fetal plasma to blood gas, acid-base, and heart rate variables which are commonly used to determine fetal distress. Fifteen experiments were conducted on 8 anaesthetised fetal sheep in utero between 125 and 145 days of gestation (term is at 147 days). They were subjected to 11 consecutive episodes of asphyxia of 30 (n = 3), 60 (n = 9), or 90 (n = 3) s over 33 min, achieved by arrest of uterine blood flow. Blood samples were drawn at 0, 33, and 60 min to determine arterial blood gases, acid base-balance, and concentrations of lactate, glucose, norepinephrine, and epinephrine. Fetal transcutaneous PO2, relative local skin blood flow, heart rate, arterial blood pressure, and arterial O2 saturation were recorded continuously. Fetal plasma concentrations of norepinephrine and epinephrine increased logarithmically as the duration of repeated asphyxia, anaerobic metabolism, and glucose concentrations increased, and as the mean O2 saturation, transcutaneous PO2, and local skin blood flow decreased. We conclude that during repeated episodes of asphyxia in fetal sheep near term, a significant increase in sympathetic activity can be detected indirectly by transcutaneous PO2 monitoring, because sympathetic activation reduces skin blood flow.  相似文献   

8.
Remote telemetric monitoring of fetal haemodynamics in pregnant sheep would allow unrestricted animal movement, minimize suffering and distress, and improve animal welfare, while enhancing the quality of data collected. This may also be useful in clinical practice following fetal surgery. Using an open fetal surgical technique at approximately two-thirds of gestation, we implanted the catheter of a D70-PCTP haemodynamic telemetric device (Data Sciences International, Tilburg, The Netherlands) into the carotid artery of the fetal sheep (n = 4). The attached transmitter was secured to the posterior aspect of the maternal anterior abdominal wall. Two receivers, with a range of 1 m each, were sited in an 11 m2 sheep enclosure to maximize animal freedom while allowing continuous monitoring of the ewe. The receivers were connected by cable to a nearby computer. In the first two procedures, both fetuses died eight and 12 days after surgery, and the catheter tip was observed to be lying in the bicarotid trunk. In the next two procedures the catheter tip was threaded further upstream from the insertion point, in an attempt to reach the fetal aorta, and both fetuses survived until the scheduled postmortem examination at the end of pregnancy. After catheter implantation, fetal blood pressure (BP) and heart rate (HR) were successfully recorded continuously for seven days and then hourly per day for a further three weeks. The fetal BP and HR values were in the normal range for healthy sheep fetuses.  相似文献   

9.
目的:探讨双胎妊娠中一胎宫内死亡的原因、对母亲和存活胎儿的影响及临床处理方法。方法:对2001年1月至2011年10月分娩的双胎妊娠之一胎宫内死亡的18例产妇临床资料进行回顾性分析。结果:双胎妊娠一胎宫内死胎的发生率占双胎的1.08%,其中单绒毛膜双羊膜囊双胎(monochorionic-diamniotic twin,MCDA)11例(61.11%),双绒毛膜双羊膜囊双胎(dichorionic-diamniotic twin,DCDA)7例(38.89%)。胎儿死因:胎盘脐带因素3例(16.67%),胎儿畸形1例(5.56%),妊娠并发症3例(16.67%),双胎输血综合征(twin-twin transfusion syndrome,TTTs)3例(16.67%),宫内感染3例(16.67%),不明原因5例(27.78%)。另一胎选择剖宫产者13例,阴道分娩3例。双胎一胎死亡后对母体的凝血功能影响不大(P>0.05)。结论:单绒毛膜双胎较双绒毛膜双胎母儿结局存在差别;双胎一胎宫内死亡对母体及存活儿有一定影响。对于孕周小,胎儿尚不成熟的病例,可严密监测存活胎儿宫内情况,行期待治疗延长孕龄至足月再分娩。  相似文献   

10.
X. De Muylder 《CMAJ》1982,127(12):1172-5,1194
In most cases a count of the active movements of the fetus by the mother is a good index of fetal activity. The information provided compares favourably with that furnished by analysis of the fetal heart rate and hormone levels in the mother''s plasma. Counting the fetal movements every day for 1 or 2 hours starting at the 24th to 26th week of pregnancy is a simple, inexpensive and noninvasive method that could be used as and screening test for fetal distress. More complex and costly investigations necessitating hospitalization could then be reserved for patients noting an abnormal count. However, this scheme demands intelligence and motivation of the mother, and one must expect a certain rate of refusal or dropout.  相似文献   

11.
目的:探讨四维彩超技术在筛查胎儿先天性心脏病的应用价值。方法:择取我院2012年3月至2014年3月收治的行产前筛查的300例产妇为研究对象,采用四维彩色多普勒超声择取心脏三血管、四腔观、肺动脉分叉、上下腔静脉回流、动脉导管弓、主动脉弓等常规切面,予以胎心各腔血流及胎心率等多项检测,对胎儿是否存在先心病进行综合诊断,并综合胎儿大体解剖状况,与病理诊断及二维超声检查结果进行对比。结果:四维彩超检出率为6.67%,正确率为90.00%;二维超声检出率为6.00%,正确率为83.33%,两组比较差异具有统计学意义(P0.05)。结论:四维彩超技术在筛查胎儿先天性心脏病中具有至关重要的应用价值,有助于指导胎儿先天性心脏病早期治疗,保证患儿预后,值得临床借鉴。  相似文献   

12.
《IRBM》2020,41(5):252-260
ObjectiveMonitoring the heartbeat of the fetus during pregnancy is a vital part in determining their health. Current fetal heart monitoring techniques lack the accuracy in fetal heart rate monitoring and features acquisition, resulting in diagnostic medical issues. The demand for a reliable method of non-invasive fetal heart monitoring is of high importance.MethodElectrocardiogram (ECG) is a method of monitoring the electrical activity produced by the heart. The extraction of the fetal ECG (FECG) from the abdominal ECG (AECG) is challenging since both ECGs of the mother and the baby share similar frequency components, adding to the fact that the signals are corrupted by white noise. This paper presents a method of FECG extraction by eliminating all other signals using AECG. The algorithm is based on attenuating the maternal ECG (MECG) by filtering and wavelet analysis to find the locations of the FECG, and thus isolating them based on their locations. Two signals of AECG collected at different locations on the abdomens are used. The ECG data used contains MECG of a power of five to ten times that of the FECG.ResultsThe FECG signals were successfully isolated from the AECG using the proposed method through which the QRS complex of the heartbeat was conserved, and heart rate was calculated. The fetal heart rate was 135 bpm and the instantaneous heart rate was 131.58 bpm. The heart rate of the mother was at 90 bpm with an instantaneous heart rate of 81.9 bpm.ConclusionThe proposed method is promising for FECG extraction since it relies on filtering and wavelet analysis of two abdominal signals for the algorithm. The method implemented is easily adjusted based on the power levels of signals, giving it great ease of adaptation to changing signals in different biosignals applications.  相似文献   

13.
B. N. Barwin  A. Dempsey  B. Ivey 《CMAJ》1978,118(3):292-294
To ensure an optimum result in pregnancy it is essential that the physician be alert in the antenatal period to recognize those women and their babies who are at risk during labour. Premature labour, with its attendant risk of respiratory distress syndrome in the newborn, continues to be an important factor in perinatal morbidity and mortality. Early recognition of predisposing factors and the judicious use of myometrial inhibiting agents have helped to reduce the incidence of fetal prematurity in these cases. A long interval between rupture of the membranes and delivery continues to be a danger to both mother and fetus. Delivery is recommended when gestation is beyond 36 weeks or when there are signs of incipient infection, and once labour has begun antibiotics should be used prophylactically. Failure of labour to progress should be recognized and managed aggressively in its early stages. Amniotomy and oxytocin infusion have reduced considerably the incidence of prolonged labour and its risks to both mother and fetus. The role of intrapartum monitoring of the fetal heart rate, measurement of the pH in the fetus''s scalp blood and assessment of amniotic fluid is discussed, as is the monitoring of maternal well-being.  相似文献   

14.
Fetal ECG-electrodes and an intrauterine catheter were inserted into 15 Holstein-Friesian cows during their first stage of labor to make a cardiotocogram. Simultaneously, fetal heart rate and intrauterine pressure were recorded until completion of fetal expulsion. Immediatly post partum the viability of the calf was assessed by clinical evaluation and measurements of blood pH, base excess (BE) and pCO(2). Fetal heart rate patterns and their changes were evaluated according to standards used in human medicine. Basal fetal heart rate (90 to 120) in 10 calves gradually increased towards the end of parturition, with a marked loss of variability. Decelerations, coinciding with periods of increased intrauterine pressure, occurred in all cows. When decelerations occurred beyond the end of a contraction the calf was born in a poor condition. Accelerations were only recorded in two cows. Many of the fetal heart rate changes observed were similar to those which in human cardiotocography are considered to be signs of fetal distress. Further investigation is needed to establish the predictive value of fetal heart rate patterns in cows, which would be a welcome addition to improved fetal diagnostics during parturition.  相似文献   

15.
摘要 目的:探讨超声联合染色体检测对胎儿心血管畸形的诊断价值。方法:2017年6月到2020年12月选择在本院诊治的高危孕妇117例作为研究对象,所有孕妇都给予胎儿心脏超声检查与羊膜穿刺染色体检查,判断胎儿心血管畸形情况。结果:在117例孕妇中,胎儿心脏超声检出胎儿心血管畸形37例,占比31.6%,前三位主要为室间隔缺损、左上腔静脉、右锁骨下动脉。羊膜腔穿刺术检出32例染色体异常胎儿,占比27.4%,其中染色体数目异常30例,染色体结构异常2例,前三位分别为21-三体、13-三体与18-三体。超声检查胎儿心血管畸形37例中,染色体异常30例;超声检查胎儿心血管正常80例中,染色体异常2例,对比差异有统计学 意义(P<0.05)。联合诊断为胎儿心血管畸形39例,随访后确诊为胎儿心血管畸形40例,超声联合染色体检测对胎儿心血管畸形的敏感性与特异性为100.0%(39/39)和98.7%(77/78)。结论:胎儿心脏超声联合染色体检测对胎儿心血管畸形的诊断具有很高敏感性与特异性,可尽最大可能提高出生缺陷儿的检出率,有很好的应用价值。  相似文献   

16.
In the United States and most industrialized countries, intrapartum fetal surveillance is performed primarily by electronic fetal heart rate monitoring. Following implementation of this technology into clinical practice, a reduction in perinatal mortality has been accompanied by a concomitant increase in the cesarean section rate to concerning levels. Although these trends are not solely due to one factor such as electronic fetal heart rate monitoring, it is well-recognized that this method of surveillance is hampered by subjectivity in interpretation and by a high false-positive (falsely nonreassuring) rate. The purpose of this review is to assess the physiologic rationale for intrapartum assessment, the significant limitations of current primary and ancillary monitoring methods, and the development of new technologies such as fetal oxygen saturation monitoring (pulse oximetry) that potentially hold great promise for the future.  相似文献   

17.
It has been proposed that fetal adaptations to intrauterine nutrient deprivation permanently reprogram the cardiovascular system. We investigated the impact of restricted periconceptional nutrition and/or restricted gestational nutrition on fetal arterial blood pressure (BP), heart rate, rate pressure product, and the fetal BP responses to ANG II and the angiotensin-converting enzyme inhibitor captopril during late gestation. Restricted periconceptional nutrition resulted in an increase in fetal mean arterial BP between 115 and 125 days gestation (restricted 41.5 +/- 2.8 mmHg, n = 12; control 38.5 +/- 1.5 mmHg, n = 13) and between 135 and 147 days gestation (restricted 50.5 +/- 2.2 mmHg, n = 8; control 42.5 +/- 1.9 mmHg, n = 10) as well as an increase in the rate pressure product in twin, but not singleton, fetuses between 115 and 147 days gestation. Mean BP and fetal plasma ACTH were also positively correlated in twin, but not singleton, fetuses. This is the first demonstration that maternal undernutrition during the periconceptional period results in an increase in fetal arterial BP. This increase occurs concomitantly with an increase in fetal ACTH but is not dependent on activation of the fetal renin-angiotensin system.  相似文献   

18.
摘要 目的:探讨超声心动图联合心电图对妊娠中期心脏畸形胎儿的诊断价值。方法:回顾性分析我院2019年1月到2021年1月出生后确诊与尸检确诊为心脏畸形的80例胎儿的临床相关指标,分析80例胎儿超声心动图检查与胎儿心电图检查结果,并分析超声心动图联合心电图对妊娠中期心脏畸形胎儿的诊断价值。结果:80例胎儿有56例出现不同程度的心电图异常现象,其中胎心早搏3例、FQRS振幅增高12例、ST段改变15例、FQRS时限增宽3例、胎心不齐4例、胎心过缓3例、胎心过速16例;80例胎儿通过尸检和出生后随访最终确定左心发育不良综合征(HLHS)4例,单心室6例,完全性心内膜垫缺损(ECD)8例,法洛四联症(TOF)14例,卵圆孔直径大于 6 mm 17例,室间隔缺损(VSD)31例,与超声心动图诊断结果对比无显著差异(P>0.05),超声心动图有7例漏诊;联合诊断与超声心动图和心电图对左心发育不良综合征、单心室、完全性心内膜垫缺损胎儿的诊断对比无明显差异(P>0.05),对法洛四联症、卵圆孔直径大于 6 mm、室间隔缺损和心脏畸形诊断总数方面联合诊断优于超声心动图和心电图单一诊断(P<0.05);通过不同检查的检测价值对比发现,超声心动图联合心电图检查的准确度、敏感度、特异度、阳性预测值和阴性预测值明显高于超声心动图与心电图单一检查。结论:超声心动图和心电图对于妊娠中期心脏畸形胎儿的诊断均具有重要价值。心脏畸形胎儿在妊娠中期进行心电图检查会出现异常现象,但是并不能确诊为心脏畸形,还需后续继续应用超声心动图进行检查,最终确诊胎儿是否存在心脏畸形现象。  相似文献   

19.
The effect of dietary vitamin E on the fetal ischemic distress induced by clamping the uterotubal vessels of pregnant rats was studied. The fetal heart rate was measured by the pulsed doppler technique as an index of fetal distress induced by ischemia. On reperfusion after clamping the vessels for 9 min, the decreased fetal heart rate was restored to normal rapidly and completely in the E-supplemented group, but slowly and incompletely in the E-deficient and control groups. On reperfusion after ischemia, the amounts of lipid peroxides, measured as thiobarbituric acid (TBA)-reactive substances, were greatly increased in the fetal brain and liver and in the placenta of in the E-deficient and control groups, but not in the E-supplemented group. The vitamin E concentrations in fetal tissues were less than 10% of those in the maternal tissues. Significant differences were found in the vitamin E concentrations in the maternal serum and liver in the three groups of rats given diet containing different amounts of vitamin E for 2 weeks. No significant differences were found between the vitamin E-deficient and control groups in the levels of vitamin E in the fetal brain and liver and the placenta, but these levels were significantly lower than those in the E-supplemented group.  相似文献   

20.
Twin pregnancies represent a management problem in dairy cattle since the risk of pregnancy loss increases, and the profitability of the herd diminishes drastically as the frequency of twin births increases. The aim of this study was to monitor the development of 211 twin pregnancies in high producing dairy cows in order to determine the best time for an embryo reduction approach. Pregnancy was diagnosed by transrectal ultrasonography between 36 and 42 days after insemination. Animals were then subjected to weekly ultrasound examination until Day 90 of gestation or until pregnancy loss. Viability was determined by monitoring the embryonic/fetal heartbeat until Day 50 of pregnancy, and then by heartbeat or fetal movement detection. Eighty-six cows (40.8%) bore bilateral and 125 (59.2%) unilateral twin pregnancies. Embryo death was registered in one of the two embryos in 35 cows (16.6%), 33 of them at pregnancy diagnosis. Pregnancy loss occurred in 22 of these cows between 1 and 4 weeks later. Thus, 13 (6.2% of the total animals) cows, carrying one dead of the two embryos, maintained gestation. Total pregnancy loss before Day 90 of pregnancy (mean 69 +/- 14 days) was registered in 51 (24.2%) cows: 7 (8%) of bilateral pregnancies and 44 (35.2%) of unilateral pregnancies, and it was higher (P = 0.0001) for both right (32.4%, 24/74) and left (39.2%, 20/51) unilateral than for bilateral (8.1%, 7/86) twin pregnancies. The single embryo death rate was significantly (P = 0.02) lower for cows with bilateral twins (9.3%, 8/86) than for total cows with unilateral twins (21.6%, 27/125). By way of overall conclusion, embryo reduction can occur in dairy cattle, and the practical perspective remains that most embryonic mortality in twins (one of the two embryos) occurs around Days 35-40 of gestation, the period when pregnancy diagnosis is generally performed and when embryo reduction could be tried.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号