首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Karenitecin is a novel, highly lipophilic camptothecin derivative with potent anticancer potential. We have developed a sensitive high-performance liquid chromatographic method for the determination of karenitecin concentration in human plasma and urine. Karenitecin was isolated from human plasma and urine using solid-phase extraction. Separation was achieved by gradient elution, using a water and acetonitrile mobile phase, on an ODS analytical column. Karenitecin was detected using fluorescence detection at excitation and emission wavelengths of 370 and 490 nm, respectively. Retention time for karenitecin was 16.2±0.5 min and 8.0±0.2 min for camptothecin, the internal standard. The karenitecin peak was baseline resolved, with the nearest peak at 3.1 min distance. Using normal volunteer plasma and urine from multiple individuals, as well as samples from the 50 patients analyzed to date, no interfering peaks were detected. Inter- and intra-day coefficients of variance were <4.4 and 7.1% for plasma and <4.9 and 11.6% for urine. Assay precision, based on an extracted karenitecin standard plasma sample of 2.5 ng/ml, was +4.46% with a mean accuracy of 92.4%. For extracted karenitecin standard urine samples of 2.5 ng/ml assay precision was +2.35% with a mean accuracy of 99.5%. The mean recovery of karenitecin, at plasma concentrations of 1.0 and 50 ng/ml, was 81.9 and 87.8% respectively. In urine, at concentrations of 1.5 and 50 ng/ml, the mean recoveries were 90.3 and 78.4% respectively. The lower limit of detection (LLD) for karenitecin was 0.5 ng/ml in plasma and 1.0 ng/ml in urine. The lower limit of quantification (LLQ) for karenitecin was 1 ng/ml and 1.5 ng/ml for plasma and urine, respectively. Stability studies indicate that when frozen at −70°C, karenitecin is stable in human plasma for up to 3 months and in human urine for up to 1 month. This method is useful for the quantification of karenitecin in plasma and urine samples for clinical pharmacology studies in patients receiving this agent in clinical trials.  相似文献   

2.
A fully validated gas chromatographic-mass spectrometric (GC-MS) method for the accurate and precise quantification of NG,NG-dimethyl-L-arginine (asymmetric dimethylarginine, ADMA), an endogenous inhibitor of the NO synthase, in cell culture supernatants and in small volumes of plasma is described. ADMA was concentrated by solid phase extraction and converted to its methyl ester pentafluoropropionic amide derivative. The derivatives were analyzed without any further purification. Using gas chromatography-chemical ionization mass spectrometry, fragment ions at m/z 634 and m/z 640 were obtained for ADMA and for NG,NG-[2H6]-dimethyl-L-arginine ([2H6]-ADMA) as internal standard, respectively. [2H6]-ADMA was synthesized by reaction of L-ornithine fastened at bromcyan-agarose with dimethylamine. The limit of detection of the method was 2 fmol, while the limit of quantitation for cell culture supernatants was 0.05 microM. The method was validated in a concentration range of 0-1.2 microM in cell culture medium and 0-2 microM in 50 microl aliquots of human plasma. The precision was > or =97% and the accuracy was determined to be > or =94%. This method is fast, rugged and an alternative to high performance liquid chromatography (HPLC) analysis of ADMA in cell culture supernatants and small volumes of human plasma.  相似文献   

3.
We devised a sensitive and simple method to determine alpha-methyltryptamine (AMT) and 5-methoxy-N,N-diisopropyltryptamine (5MeO-DIPT) in whole blood and urine, using gas chromatography-mass spectrometry (GC-MS). AMT and 5MeO-DIPT were extracted using an Extrelut column with an internal standard, bupivacaine, followed by derivatization with acetic anhydride. The derivatized extract was used for GC-MS analysis of EI-SIM mode. The calibration curves of AMT and 5MeO-DIPT were linear in the concentration range from 10 to 750 ng/ml in both blood and urine samples. The method detection limit (MDL) of AMT and 5MeO-DIPT were 1 ng/ml each in whole blood and 5 ng/ml each in urine. This method should be most useful to accurately determine the presence of these drugs in blood and urine in clinical and forensic cases.  相似文献   

4.
A selective chiral high performance liquid chromatographic (HPLC) method was developed and validated to separate and quantify the enantiomers of a novel anticonvulsant agent, N-(4-chlorophenyl)-1-(4-pyridyl)ethylamine (AAP-Cl), in rat plasma. After extraction of the plasma samples with ethyl acetate, the separation was accomplished by an HPLC system consisting of a Chirex chiral column (250 mm x 4.6 mm i.d.) and a mobile phase of hexane:ethanol:tetrahydrofuran (280:20:40 (v/v)) containing trifluroacetic acid (0.3% (v/v)) and triethylamine (0.018% (v/v)) at a flow rate of 0.8 ml/min with UV detection. Male Sprague-Dawley rats were given (+)-AAP-Cl (10 and 20 mg/kg), (-)-AAP-Cl (10 mg/kg) or the racemic mixture (20 mg/kg) by i.v. bolus injection and serial blood samples were collected at different times after drug administration. (+)-AAP-Cl and (-)-AAP-Cl were separated with a resolution factor, Rs, of at least 1.4, and a separation factor, alpha, greater than 1.09. Linear calibration curves were obtained over the concentration range of 0.5-30 microg/ml in plasma for both (+)-AAP-Cl and (-)-AAP-Cl (R2 > or = 0.996) with a limit of quantitation of 100 ng/ml and the recovery was greater than 80% for both enantiomers. The accuracy and precision for both enantiomers ranged from 96 to 102% (+/-0.2-7%) at upper and lower concentrations. The plasma concentration-time profiles of the enantiomers of AAP-Cl were best described by a two-compartment open model with a mean terminal half-life of about 5h, volume of distribution at steady state of 3 l/kg and clearance of about 0.6l/(hkg) in rats. There was no significant difference between the pharmacokinetic parameters of (+)-AAP-Cl and (-)-AAP-Cl, suggesting that the disposition of AAP-Cl in rats is not enantioselective. In addition, no chiral inversion of (+)-AAP-Cl to (-)-AAP-Cl or vice versa was observed. The results of this investigation have shed some light on the mechanism of action and disposition of AAP-Cl in rats.  相似文献   

5.
A rapid, reliable and specific reversed-phase high-performance liquid chromatographic procedure is described for the determination of diphenylpyraline hydrochloride at nanogram concentrations in plasma and urine. After extraction of the drug with n-pentane-2-propanol (50:1) from alkalinized samples, the organic extract was evaporated to dryness, reconstituted with methanol and chromatographed using a 5-μm Asahipak ODP-50 C18 column with UV detection at 254 nm. The elution time for diphenylpyraline was 7.9 min. The overall recovery of diphenylpyraline from spiked plasma and urine samples at concentrations ranging from 53 to 740 ng/ml were 94.65% and 92.29%, respectively. Linearity and precision data for plasma and urine standards after extraction were acceptable. The limit of detection was 15 ng/ml for both plasma and urine samples at 0.002 AUFS.  相似文献   

6.
(E)-5-(2-Bromovinyl)-2′-deoxyuridine is an antiviral drug used for treatment of infections with Herpes simplex virus type 1 as well as Varicella zoster virus. Two fast methods for the determination of the drug and its metabolite in plasma and urine by capillary electrophoresis have been developed. The plasma method can be used for measurement of total as well as unbound drug and metabolite. Plasma and urine samples are prepared for measuring by liquid/liquid extraction resulting in a limit of quantification of 40 ng/ml for total and 10 ng/ml for free BVdU in plasma and 170 ng/ml in urine. Inter- as well as intra-day precision were found to be better than 10% and both methods have been used for drug monitoring of patients.  相似文献   

7.
An HPLC method for determining quercetin in human plasma and urine is presented for application to the pharmacokinetic study of rutin. Isocratic reversed-phase HPLC was employed for the quantitative analysis by using kaempferol as an internal standard. Solid-phase extraction was performed on an Oasis HLB cartridge (>95% recovery). The HPLC assay was carried out using a Luna ODS-2 column (150 x 2.1 mm I.D., 5 microm particle size). The mobile phase was acetonitrile-10 mM ammonium acetate solution containing 0.3 mM EDTA-glacial acetic acid, 29:70:1 (v/v, pH 3.9) and 26:73:1 (v/v, pH 3.9) for the determination of plasma and urinary quercetin, respectively. The flow-rate was 0.3 ml/min and the detection wavelength was set at 370 nm. Calibration of the overall analytical procedure gave a linear signal (r>0.999) over a concentration range of 4-700 ng/ml of quercetin in plasma and 20-1000 ng/ml of quercetin in urine. The lower limit of quantification was approximately 7 ng/ml of quercetin in plasma and approximately 35 ng/ml in urine. The detection limit (defined at a signal-to-noise ratio of about 3) was approximately 0.35 ng/ml in plasma and urine. A preliminary experiment to investigate the plasma concentration and urinary excretion of quercetin after oral administration of 200 mg of rutin to a healthy volunteer demonstrated that the present method was suitable for determining quercetin in human plasma and urine.  相似文献   

8.
The analysis of arildone in plasma, urine and feces by gas—liquid chromatography with electron-capture detection is described. O-(2,3,4,5,6-Pentafluorohenzyl)hydroxylamine is the derivatizing agent for the plasma and urine analysis; 3-nitrophenylhydrazine is utilized for fecal analysis. The mean (± S.E.) minimum quantifiable level of arildone was 1.4 (± 0.2) ng/ml in urine, 6.4 (± 0.1) ng/ml in plasma, and 12.6 (± 1.0) ng/g in feces. The chromatographic response was linear in the range of 0 and 10–120 ng/ml for plasma, 0 and 2.5–20 ng/ml for urine and 0 and 25–250 ng/g for feces. The estimated overall precision of the assay was 5.5%, 6.4% and 8.9% in urine, plasma and feces, respectively.  相似文献   

9.
We have established a highly sensitive high-performance liquid chromatographic method for the determination of an anticancer drug, UCN-01, in human plasma or urine. Using a fluorescence detector set at an excitation wavelength of 310 nm and emission monitored at 410 nm, there was a good linearity for UCN-01 in human plasma (r=0.999) or urine (r=0.999) at concentrations ranging from 0.2 to 100 ng/ml or 1 to 400 ng/ml, respectively. For intra-day assay, in plasma samples, the precision and accuracy were 1.8% to 5.6% and −10.0% to 5.2%, respectively. For inter-day assay, the precision and accuracy were 2.0% to 18.2% and 2.4% to 10.0%, respectively. In urine samples, the intra- and inter-day precision and accuracy were within 3.9% and ±2.7%, respectively. The lower limit of quantification (LLOQ) was set at 0.2 ng/ml in plasma and 1 ng/ml in urine. UCN-01 in plasma samples was stable up to two weeks at −80°C and also up to four weeks in urine samples. This method could be very useful for studying the human pharmacokinetics of UCN-01.  相似文献   

10.
We report a method for the simultaneous determination of methamphetamine, amphetamine and their hydroxylated metabolites in plasma and urine samples using a GC-NPD system. The analytical procedures are: (1) adjust the sample to pH 11.5 with bicarbonate buffer, saturate with NaCl and extract with acetate; (2) back-extract the amines in the ethyl acetate fraction with 0.1 M HCl; (3) adjust the pH of the acid fraction to 11.5 and follow by extraction in ethyl acetate; (4) reduce the volume of ethyl acetate under nitrogen and derivatize the concentrate with trifluoroacetic anhydride or heptaflourobutyric anhydride before the GC analysis. The derivatives were separated on a GC-NPD system equipped with a HP-5 column of 25 m×0.32 m I.D. and a 0.52 μm film of 5% phenylmethylsilicone. The detection limit (taking a signal-to-noise ratio of 2) of heptafluorobutyl derivatives of methamphetamine and its metabolites in plasma and the trifluoroacetyl derivatives in urine was 1 ng/ml (22 pg on column). The limit of quantitation of the heptafluorobutyl derivatives in the plasma was 1 ng/ml (22 pg on column), and that of the trifluoroacetyl derivatives in urine was 20 ng/ml (73 pg on column). The between-day variation was from 0.9 to 17.4% and within-day variation from 0.9 to 8.3%. This method was used successfully in the quantitative determination of methamphetamine and its p-hydroxylated metabolites in the plasma and urine of human subjects.  相似文献   

11.
This paper describes the development of a simple and sensitive analytical method for the quantification of melatonin in human plasma and rabbit serum, using standard analytical equipment and on-line column enrichment without prior extraction, clean-up or derivatization. The analytical procedure was found to be accurate, precise and linear. For human plasma, the accuracy was 101% (range 89–106%), and the mean precision was 5% (range 2–9%) for all concentrations (0, 2, 10, 50 and 200 ng/ml) tested (n=6). The accuracy in rabbit serum was 101% (range 90–112%), and the mean precision was 13% (range 8–19%) for all concentrations (0, 2, 10, 50, 200 and 500 ng/ml) tested (n=6). The retention time of melatonin was about 8 min and the total recoveries were found to be approximately 65 and 85%, respectively, for human plasma and rabbit serum. The limit of detection was found to be lower than 1 ng/ml for human plasma and around 2 ng/ml for rabbit serum. The method is, therefore, found to be suitable for melatonin bioavailability studies in rabbits and presumably also in humans.  相似文献   

12.
A sensitive high-performance liquid chromatographic (HPLC) method with ultraviolet absorption detection (292 nm) was developed and validated for the determination of the new phosphodiesterase V inhibitor, DA-8159 (DA), in human plasma and urine. A single step liquid-liquid extraction procedure using ethyl ether was performed to recover DA and the internal standard (sildenafil citrate) from 1.0 ml of biological matrices combined with 200 microl of 0.1M sodium carbonate buffer. A Capcell Pak C18 UG120 column (150 mm x 4.6 mm I.D., 5 microm) was used as a stationary phase and the mobile phase consisted of 30% acetonitrile and 70% 20mM potassium phosphate buffer (pH 4.5) at a flow rate of 1.0 ml/min. The lower limit for quantification was 5 ng/ml for plasma and 10 ng/ml for urine samples. Within- and between-run accuracy and precision were < or =15 and < or =10%, respectively, in both plasma and urine samples. The recovery of DA from human plasma and urine was greater than 70%. Separate stability studies showed that DA is stable under the conditions of analysis. This validated assay was used for the pharmacokinetic analysis of DA during a phase I, rising dose study.  相似文献   

13.
A sensitive and specific method was developed and validated for the quantitation of quercetin in human plasma and urine. The application of liquid chromatography-tandem mass spectrometry (LC/MS/MS) with a TurboIonspray (TIS) interface in negative mode under multiple reactions monitoring was investigated. Chromatographic separation was achieved on a C12 column using a mobile phase of acetonitrile/water with 0.2% formic acid (pH 2.4) (40/60, v/v). The detection limit was 100 pg/ml and the lower limit of quantification was 500 pg/ml for plasma samples; the detection limit was 500 pg/ml and the lower limit of quantification was 1 ng/ml for urine samples. The calibration curve was linear from 1 to 800 ng/ml for plasma samples and was linear from 1 to 200 and 50 to 2000 ng/ml for urine samples. All the intra- and inter-day coefficients of variation were less than 11% and intra- and inter-day accuracies were within +/-15% of the known concentrations. This represents a LC/MS/MS assay with the sensitivity and specificity necessary to determine quercetin in human plasma and urine. This assay was used to determine both parent quercetin and the quercetin after enzymatic hydrolysis with beta-glucuronidase/sulfatase in human plasma and urine samples following the ingestion of quercetin 500 mg capsules.  相似文献   

14.
We have developed and validated a sensitive and selective assay for the quantification of paclitaxel and its metabolites 6α,3′-p-dihydroxypaclitaxel, 3′-p-hydroxypaclitaxel and 6α-hydroxypaclitaxel in plasma, tissue, urine and faeces specimens of mice. Tissue and faeces were homogenized (approximately 0.1–0.2 g/ml) in bovine serum albumin (40 g/I) in water, and urine was diluted (1:5, v/v) in blank human plasma. Sample pretreatment involved liquid-liquid extraction of 200–1000 μl of sample with diethyl ether followed by automated solid-phase extraction using cyano Bond Elut column. 2′-Methylpaclitaxel was used as internal standard. The overall recovery of the sample pretreatment procedure ranged from 76 ot 85%. In plasma, the lower limit of detection (LOD) and the lower limit of quantitation (LLQ) are 15 and 25 ng/ml, respectively, using 200 μl of sample. In tissues, faeces and urine the LLQs are 25–100 ng/g, 125 ng/g and 25 ng/ml, respectively, using 1000 μl (faeces: 200 μl) of homogenized or diluted sample. The concentrations in the various biological matrices, for validation procedures spiked with known amounts of the test compounds, are read from calibration curves constructed in blank human plasma in the range 25–100 000 ng/ml for paclitaxel and 25–500 ng/ml for the metabolites. The accuracy and precision of the assay fall within the generally accepted criteria for bio-analytical assays.  相似文献   

15.
A simple high-performance liquid chromatographic (HPLC) method was developed for the determination of losartan and its E-3174 metabolite in human plasma, urine and dialysate. For plasma, a gradient mobile phase consisting of 25 mM potassium phosphate and acetonitrile pH 2.2 was used with a phenyl analytical column and fluorescence detection. For urine and dialysate, an isocratic mobile phase consisting of 25 mM potassium phosphate and acetonitrile (60:40, v/v) pH 2.2 was used. The method demonstrated linearity from 10 to 1000 ng/ml with a detection limit of 1 ng/ml for losartan and E-3174 using 10 μl of prepared plasma, urine or dialysate. The method was utilized in a study evaluating the pharmacokinetic and pharmacodynamic effects of losartan in patients with kidney failure undergoing continuous ambulatory peritoneal dialysis (CAPD).  相似文献   

16.
A specific method for the quantitative determination of valproic acid in human plasma is presented. Valproate was extracted from acidified plasma by hexane extraction and converted to its trimethylsilyl derivative without sample concentration. The derivatives were analyzed without any further purification. Using gas chromatography-electron ionization mass spectrometry, diagnostic useful fragment ions at m/z 201 and 205 were obtained for valproic acid and [(18)O(2)]valproic acid internal standard, respectively. [(18)O(2)]Valproic acid was synthesized from unlabeled valproate by acid-catalyzed exchange reaction in H(2)(18)O. The method was validated in the expected concentration range of a pharmacokinetic study. Thus, calibration graphs were linear within a range of 0.47-120 microgram/ml plasma. Intra-day precision was 2.29% (0.47 microgram/ml), 2.93% (4 microgram/ml), 3.22% (20 microgram/ml) and 4.40% (80 microgram/ml), inter-day variability was found to be 1.49% (0.47 microgram/ml), 3.79% (20 microgram/ml), 2.74% (40 microgram/ml) and 3.03% (80 microgram/ml). Inter-day accuracy showed deviations of 1.94% (0.47 microgram/ml), 0.53% (4 microgram/ml), -0.32% (20 microgram/ml) and 0.06% (80 microgram/ml). The method is rugged and robust and has been applied to the batch analysis of valproate during pharmacokinetic profiling of the drug.  相似文献   

17.
A liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method has been developed for the determination of trenbolone in bovine urine and serum. The aim was a control of the misuse of trenbolone in food-producing animals. The procedure involved, in both cases, a preliminary solid-phase clean-up followed by a liquid-liquid extraction for urine samples after a preliminary enzymatic hydrolysis. The extracts have been directly analysed by reversed-phase LC-MS-MS in selected reaction monitoring (SRM), acquiring two diagnostic product ions from the chosen precursor [M+H](+). The procedures were validated across the concentration range of 1-1500 ng/ml. The linearity, the inter- and intra-day accuracy and precision have been determined. The procedure was specific and the accuracy values were better than 20% at the limit of quantitation of spiked samples. The limit of quantification (LOQ) and the limit of detection (LOD) were, respectively, 1 ng/ml and 350 pg/ml for urine and serum. According to the draft, SANCO/1805/2000, we determined the decision limit CCalpha and the detection capability CCbeta. The recovery values for urine ranged from 87 to 128%, and for plasma the recovery was 70+/-4%. The procedure proved to be simple and suitable for routine and confirmatory purposes such as those developed for residue studies.  相似文献   

18.
Sanguinarine is a quaternary benzo[c]phenanthridine alkaloid, extracted from the argemone oil, which produced severe human intoxications. To investigate the sanguinarine biotransformation, we develop a simple extraction process and a high performance liquid chromatographic separation coupled to a sensitive fluorometric detection of sanguinarine in cell culture medium, as well as in rat urine and plasma. After extraction with an acidified organic solvent, sanguinarine elution is performed within 15 min on a Nucleosil C18 column with a gradient using 0.2% formic acid/water/acetonitrile as mobile phase. Extracted and standard sanguinarine are characterized by mass spectrometry. The extraction recovery of sanguinarine is about 80% in cell culture medium and in rat urine, but lower in plasma. This convenient high performance liquid chromatography (HPLC) method allows to quantify sanguinarine over concentrations ranged 10-2000 ng ml(-1). The limit of fluorometric detection is 0.5 ng. Under these conditions, the lower limit of quantification of sanguinarine is 50 ng ml(-1) in cell culture medium and in rat urine and 100 ng ml(-1) in rat plasma. This analytical HPLC method is specific, linear and reproducible in all media and is suitable for quantitative determination of sanguinarine in biological fluids.  相似文献   

19.
A simple high-performance liquid chromatography (HPLC)-tandem mass spectrometric method has been developed for determination of propiverine hydrochloride and its metabolite, propiverine N-oxide (M-1) in human plasma using stable isotopes, propiverine hydrochloride-d10 and M-1-d10, as internal standards. The analytes were extracted with dichloromethane from 0.2 ml of plasma in neutral condition (pH 7.0) and separated by HPLC on a C18 reversed-phase column using methanol-1% acetic acid (50:50) as a mobile phase, and detected using positive electrospray ionization in selected reaction monitoring (SRM) mode. The method was validated over a concentration range of 2-500 ng/ml for propiverine hydrochloride and 4-1000 ng/ml for M-1 using 0.2 ml of human plasma per assay. The method developed was successfully applied to analysis of propiverine hydrochloride and M-1 in clinical studies.  相似文献   

20.
An atmospheric pressure ionization liquid chromatographic-mass spectrometric assay was developed and validated for the determination of D-penicillamine(2,5) enkephalin (DPDPE) in cerebrospinal fluid (CSF) from dog. DPDPE and internal standard (D-Ala(2),D-Leu(5) enkephalin=DADLE) were isolated from CSF by reversed-phase C(18) solid-phase extraction with ZipTip micro-cartridges. Aliquots of extracted eluate were injected onto an Agilent Zorbax SB C(18) column (30 x 2.2 mm; 3.5 microm) at a flow-rate of 0.4 ml/min. The isocratic mobile phase of methanol-10 mM ammonium formate (pH 3) (75:25, v/v) was then diverted to waste for 45 s after injection, after which time flow was directed to the single quadrupole mass spectrometer. DPDPE was detected by positive mode selected ion monitoring. Standard curves were linear (r(2)> or =0.991) over the concentration range 1-1000 ng/ml. The efficiency of extraction recovery was greater than 97%, and the intra-assay and inter-assay precisions were within 9% relative standard deviation. DPDPE and the internal standard were stable in the injection solvent at 4 degrees C for at least 48 h. The assay was applied to the pharmacokinetic study of intrathecal DPDPE administration in the dog animal model.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号