首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
We report a capillary-based DNA sequencing read length of 100 bases in 16 min using end-labeled free-solution conjugate electrophoresis (FSCE) with a monodisperse poly-N-substituted glycine (polypeptoid) as a synthetic drag-tag. FSCE enabled rapid separation of single-stranded (ss) DNA sequencing fragments with single-base resolution without the need for a viscous DNA separation matrix. Protein-based drag-tags previously used for FSCE sequencing, for example, streptavidin, are heterogeneous in molar mass (polydisperse); the resultant band-broadening can make it difficult to obtain the single-base resolution necessary for DNA sequencing. In this study, we synthesized and HPLC-purified a 70mer poly-N-(methoxyethyl)glycine (NMEG) drag-tag with a molar mass of - 11 kDa. The NMEG monomers that comprise this peptoid drag-tag are interesting for bioanalytical applications, because the methoxyethyl side chain's chemical structure is reminiscent of the basic monomer unit of polyethylene glycol, a highly biocompatible commercially available polymer, which, however, is not available in monodisperse preparation at an - 11 kDa molar mass. This is the first report of ssDNA separation and of four-color, base-by-base DNA sequencing by FSCE through the use of a chemically synthesized drag-tag. These results show that high-molar mass, chemically synthesized drag-tags based on the polyNMEG structure, if obtained in monodisperse preparation, would serve as ideal drag-tags and could help FSCE reach the commercially relevant read lengths of 100 bases or more.  相似文献   

2.
Protein-based polymers are increasingly being used in biomaterial applications because of their ease of customization and potential monodispersity. These advantages make protein polymers excellent candidates for bioanalytical applications. Here we describe improved methods for producing drag-tags for free-solution conjugate electrophoresis (FSCE). FSCE utilizes a pure, monodisperse recombinant protein, tethered end-on to a ssDNA molecule, to enable DNA size separation in aqueous buffer. FSCE also provides a highly sensitive method to evaluate the polydispersity of a protein drag-tag and thus its suitability for bioanalytical uses. This method is able to detect slight differences in drag-tag charge or mass. We have devised an improved cloning, expression, and purification strategy that enables us to generate, for the first time, a truly monodisperse 20 kDa protein polymer and a nearly monodisperse 38 kDa protein. These newly produced proteins can be used as drag-tags to enable longer read DNA sequencing by free-solution microchannel electrophoresis.  相似文献   

3.
End-Labeled Free-Solution Electrophoresis (ELFSE) is a new technique that is a promising bioconjugate method for DNA sequencing (or separation) and genotyping by both capillary and microfluidic device electrophoresis. Because ELFSE enables high-resolution electrophoretic separation in aqueous buffer alone (i.e., without a polymer matrix), it eliminates the need to load viscous polymer networks into electrophoresis microchannels. To achieve microchannel DNA separations with high performance, ELFSE requires monodisperse perturbing entities (i.e., drag-tags), which create a large amounts of frictional drag when pulled behind DNA during free-solution electrophoresis, and which have other properties suitable for microchannel electrophoresis. In this article, the theoretical concepts of ELFSE and the required characteristics of the drag-tag molecules for the ultimate performance of ELFSE are reviewed. Additionally, the merits and limitations of current drag-tags are also discussed in the context of recent experimental data of ELFSE separation (or sequencing).  相似文献   

4.
The development of innovative technologies designed to reduce the cost and increase the throughput of DNA separations continues to be important for large-scale sequencing and genotyping efforts. We report research aimed at the further development of a free-solution bioconjugate method of DNA size separation by capillary electrophoresis (CE), in particular, the determination of an optimal molecular architecture for polyamide-based "drag-tags". We synthesized several branched poly(N-methoxyethyl glycine)s (poly(NMEG)s, a class of polypeptoids) as novel friction-generating entities for end-on attachment to DNA molecules. A 30-mer poly(NMEG) "backbone," comprising five evenly spaced reactive epsilon-amino groups, was synthesized on solid phase, cleaved, and purified to monodispersity by RP-HPLC. Three different comblike derivatives of this backbone molecule were created by (1) acetylating the epsilon-amino groups or (2) appending small, monodisperse NMEG oligomers (a tetramer and an octamer). Grafting of the oligo(NMEG)s was done using solution-phase amide bond formation chemistry. Once purified to total monodispersity, the three different drag-tags were studied by free-solution electrophoresis to observe the effect of branching on their hydrodynamic drag or "alpha" and hence their ability to separate DNA. Drag was found to scale linearly with total molecular weight, regardless of branch length. The octamer-branched drag-tag-DNA conjugate was used to separate ssDNA products of 50, 75, 100, and 150 bases in length by free-solution CE in less than 10 min. Hence, the use of branched or comblike drag-tags is both a feasible and an effective way to achieve high frictional drag, allowing the high-resolution separation of relatively large DNA molecules by free-solution CE without the need to synthesize very long polymers.  相似文献   

5.
Nucleoprotein particles (B2), isolated following digestion of calf thymus chromatin with micrococcal nuclease, are resolved on a non-chelating Bio-Gel A-5m column. B2 protein electrophoresis showed the presence of several H1 species and several nonhistone proteins but was depleted in core histones. DNA electrophoresis demonstrated that native B2 DNA has a length of about 46 base pairs. On DNA sequencing gels, the length distribution of denatured B2 DNA ranged from 12 to 35 bases with a weighted average chain length of about 26 bases. Depletion of a 20 base band in B2 DNA suggested specific protection of internucleosomal DNA sites during the nuclease digestion.  相似文献   

6.
A non-radioactive automated method for DNA sequence determination   总被引:27,自引:0,他引:27  
A method and instrument for automated DNA sequencing without radioactivity have been developed. In spite of the success with radioactive labels there are drawbacks attached to the technique, such as hazards in the handling, storage and disposal of radioactive materials, and the considerable cost of the radiolabelled nucleoside triphosphates. In addition, there is deterioration of sample quality with time. A sulphydryl containing M13 sequencing primer has been synthesised and subsequently conjugated with tetramethylrhodamine iodoacetamide. The fluorescent primer is used to generate a nested set of fluorescent DNA fragments. The fluorescent bands are excited by a laser and detected in the gel (detection limit about 0.1 fmol per band) during electrophoresis, and sequence data from the four tracks are transferred directly into a computer. Standard gels, 200 mm wide with 20 sample slots have also been used. The device contains no moving parts. At present 250-300 bases can be read in 6 h. The system is capable of single base resolution at a fragment length of at least 400 bases.  相似文献   

7.
The use of automated fluorescent DNA sequencer systems and PCR-based DNA sequencing methods plays an important role in the actual effort to improve the efficiency of large-scale DNA analysis. While dideoxy-terminators labeled with energy-transfer dyes (BigDyes) provide the most versatile method of automated DNA sequencing, premature terminations result in a substantially reduced reading length of the DNA sequence. Premature terminations are usually evidenced by base ambiguities and are often accompanied by diminished signal intensity from that point on in the sequence. I studied a two-step protocol for Taq cycle sequencing using the ABI BigDye terminator for reducing premature terminations in DNA sequences. I demonstrate that combining the annealing step with the extension step at one temperature (60°C) reduces premature terminations in DNA sequences that regularly contain premature terminations when the three temperature steps are used. This modification significantly increases the number of accurately read bases in DNA sequences.  相似文献   

8.
Mass-spectrometry DNA sequencing   总被引:1,自引:0,他引:1  
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been explored widely for DNA sequencing. Compared to gel electrophoresis based sequencing systems, mass spectrometry produces very high resolution of sequencing fragments, rapid separation on microsecond time scales, and completely eliminates compressions associated with gel-based systems. While most of the research efforts have focused on using mass spectrometers to analyze the DNA products from Sanger sequencing or enzymatic digestion reactions, the read lengths attainable are currently insufficient for large-scale de novo sequencing. The advantage of mass-spectrometry sequencing is that one can unambiguously identify frameshift mutations and heterozygous mutations making it an ideal choice for resequencing projects. In these applications, DNA sequencing fragments that are the same length but with different base compositions are generated, which are challenging to consistently distinguish in gel-based sequencing systems. In contrast, MALDI-TOF MS produces mass spectra of these DNA sequencing fragments with nearly digital resolution, allowing accurate determination of the mixed bases. For these reasons mass spectrometry based sequencing has mainly been focused on the detection of frameshift mutations and single nucleotide polymorphisms (SNPs). More recently, assays have been developed to indirectly sequence DNA by first converting it into RNA. These assays take advantage of the increased resolution and detection ability of MALDI-TOF MS for RNA.  相似文献   

9.
Pyrosequencing is a bioluminometric DNA sequencing technique that measures the release of pyrophosphate during DNA synthesis. The amount of pyrophosphate is proportionally converted into visible light by a cascade of enzymatic reactions. Pyrosequencing has heretofore been used for generating short sequence reads (1-100 nucleotides) because certain factors limit the system's ability to perform longer reads accurately. In this study, we have characterized the main read length limiting factors in both three-enzyme and four-enzyme Pyrosequencing systems. A new simulation model was developed to simulate the read length of both systems based on the inhibitory factors in the chemical equations governing each enzymatic cascade. Our results indicate that nonsynchronized extension limits the obtained read length, albeit to a different extent for each system. In the four-enzyme system, nonsynchronized extension due mainly to a decrease in apyrase's efficiency in degrading excess nucleotides proves to be the main limiting factor of read length. Replacing apyrase with a washing step for removal of excess nucleotide proves to be essential in improving the read length of Pyrosequencing. The main limiting factor of the three-enzyme system is shown to be loss of DNA fragments during the washing step. If this loss is minimized to 0.1% per washing cycle, the read length of Pyrosequencing would be well beyond 300 bases.  相似文献   

10.
Assembling millions of short DNA sequences using SSAKE   总被引:7,自引:0,他引:7  
Novel DNA sequencing technologies with the potential for up to three orders magnitude more sequence throughput than conventional Sanger sequencing are emerging. The instrument now available from Solexa Ltd, produces millions of short DNA sequences of 25 nt each. Due to ubiquitous repeats in large genomes and the inability of short sequences to uniquely and unambiguously characterize them, the short read length limits applicability for de novo sequencing. However, given the sequencing depth and the throughput of this instrument, stringent assembly of highly identical sequences can be achieved. We describe SSAKE, a tool for aggressively assembling millions of short nucleotide sequences by progressively searching through a prefix tree for the longest possible overlap between any two sequences. SSAKE is designed to help leverage the information from short sequence reads by stringently assembling them into contiguous sequences that can be used to characterize novel sequencing targets. Availability: http://www.bcgsc.ca/bioinfo/software/ssake.  相似文献   

11.
Elkin C  Kapur H  Smith T  Humphries D  Pollard M  Hammon N  Hawkins T 《BioTechniques》2002,32(6):1296, 1298-1300, 1302
We have developed an automated purification method for dye-terminator-based DNA sequencing products using a magnetic bead approach. This 384-well protocol generates sequence fragments that are essentially free of template DNA, salt, and excess dye-terminator products. In comparison with traditional ethanol precipitation protocols, this method uses no centrifugation, is rapid, completely automated, and increases the phred-20 read length by an average of 40 bases. To date, we have processed over 4 million samples with 94% averaging 641 phred-20 bases on the MegaBACE 1000 and 4000 and the ABI PRISM 3700 capillary instruments.  相似文献   

12.
We are investigating approaches to increase DNA sequencing quality. Since a majorfactor in sequence generation is the cost of reagents and sample preparations, we have developed and optimized methods to sequence directly plasmid DNA isolated from alkaline lysis preparations. These methods remove the costly PCR and post-sequencing purification steps but can result in low sequence quality when using standard resuspension protocols on some sequencing platforms. This work outlines a simple, robust, and inexpensive resuspension protocol for DNA sequencing to correct this shortcoming. Resuspending the sequenced products in agarose before electrophoresis results in a substantial and reproducible increase in sequence quality and read length over resuspension in deionized water and has allowed us to use the aforementioned sample preparation methods to cut considerably the overall sequencing costs without sacrificing sequence quality. We demonstrate that resuspension of unpurified sequence products generated from template DNA isolated by a modified alkaline lysis technique in low concentrations of agarose yields a 384% improvement in sequence quality compared to resuspension in deionized water. Utilizing this protocol, we have produced more than 74,000 high-quality, long-read-length sequences from plasmid DNA template on the MegaBACET 1000 platform.  相似文献   

13.

Background

Advances in Illumina DNA sequencing technology have produced longer paired-end reads that increasingly have sequence overlaps. These reads can be merged into a single read that spans the full length of the original DNA fragment, allowing for error correction and accurate determination of read coverage. Extant merging programs utilize simplistic or unverified models for the selection of bases and quality scores for the overlapping region of merged reads.

Results

We first examined the baseline quality score - error rate relationship using sequence reads derived from PhiX. In contrast to numerous published reports, we found that the quality scores produced by Illumina were not substantially inflated above the theoretical values, once the reference genome was corrected for unreported sequence variants. The PhiX reads were then used to create empirical models of sequencing errors in overlapping regions of paired-end reads, and these models were incorporated into a novel merging program, NGmerge. We demonstrate that NGmerge corrects errors and ambiguous bases better than other merging programs, and that it assigns quality scores for merged bases that accurately reflect the error rates. Our results also show that, contrary to published analyses, the sequencing errors of paired-end reads are not independent.

Conclusions

We provide a free and open-source program, NGmerge, that performs better than existing read merging programs. NGmerge is available on GitHub (https://github.com/harvardinformatics/NGmerge) under the MIT License; it is written in C and supported on Linux.
  相似文献   

14.
An integrated system with a nano-reactor for cycle-sequencing reaction coupled to on-line purification and capillary gel electrophoresis has been demonstrated. Fifty nanoliters of reagent solution, which includes dye-labeled terminators, polymerase, BSA and template, was aspirated and mixed with the template inside the nano-reactor followed by cycle-sequencing reaction. The reaction products were then purified by a size-exclusion chromatographic column operated at 50°C followed by room temperature on-line injection of the DNA fragments into a capillary for gel electrophoresis. Over 450 bases of DNA can be separated and identified. As little as 25 nl reagent solution can be used for the cycle-sequencing reaction with a slightly shorter read length. Significant savings on reagent cost is achieved because the remaining stock solution can be reused without contamination. The steps of cycle sequencing, on-line purification, injection, DNA separation, capillary regeneration, gel-filling and fluidic manipulation were performed with complete automation. This system can be readily multiplexed for high-throughput DNA sequencing or PCR analysis directly from templates or even biological materials.  相似文献   

15.
We have developed a simple and efficient protocol for the isolation of good-quality recombinant phage DNA useful for all downstream processing, including automated sequencing. The overnight-grown phage particles were effectively precipitated (without any contaminating Escherichia coli DNA and other culture media components) by adjusting the pH of the culture medium to 5.2 with sodium acetate, followed by addition of ethanol to 25%. The phage DNA was selectively precipitated with ethanol in the presence of guanidinium thiocyanate under alkaline pH, resulting in uniform quality and quantity of phage DNA. The quality of the phage DNA preparation was demonstrated by DNA sequencing that provided an average read length of >700 bases (PHRED20 quality). This protocol for plating, picking, growing, and subsequent DNA purification of individual phage clones can be completely automated using any standard robotic platform. This protocol does not require any commercial kits and can be completed within 2 h.  相似文献   

16.
We examined the effect of an electric field strength gradient on DNA sequencing efficiency using capillary array electrophoresis. Several types of gradients were applied to DNA sequencing and tested in terms of read length and accuracy. Our original method improved the accuracy of DNA sequencing for longer fragments at high temperature.  相似文献   

17.
Two dimensional polyacrylamide gel electrophoresis (2D-PAGE) was used to identify differentially expressed proteins in wild-type (DP 5690) and fiberless (SL 1-7-1) cotton ovules. One protein, designated V2 was unique to ovules of the fiber producing DP 5690 line. The protein was purified from 2D-PAGE of 4 d post anthesis DP 5690 ovules and partially sequenced. The short amino acid sequence was nearly identical to the deduced amino acid sequence for cotton phenylcoumaran benzylic ether reductase (PCBER) protein. A consensus sequence was assembled from ESTs encoding cotton PCBER genes, primers were designed, and a full length gene was amplified from plasmid DNA from a 72 h etiolated cotton cotyledon library. The polymerase chain reaction generated a 950 bp product with unique EcoRI (5′) and (3′) KpnI restriction sites for directional insertion into the expression vector pPICZA. Nucleotide sequencing was performed, and the full length coding region was 924 bp encoding a protein of 308 amino acids. The molecular mass and pI measured (2D PAGE) were similar to the theoretical protein.  相似文献   

18.
Free solution capillary electrophoresis (FSCE) has been used to separate two non-self-complementary 12mer oligonucleotide duplexes: d(AAATTATATTAT).d(ATAA-TATAATTT) and d(GGGCCGCGCCGC).d(GCGGCGCGGCCC). Titration of mixtures of the two oligonucleotides with model intercalators (ethidium bromide andactinomycin D) and minor groove binders (netropsin, Hoechst 33258 and distamycin) has shown the suitability of FSCE as a method to study the sequence selectivity of DNA binding agents. Binding data have shown cooperativity of binding for netropsin and Hoechst 33258 and have provided ligand:DNA binding ratios for all five compounds. Cooperativity of netropsin binding to a 12mer with two potential sites has been demonstrated for the first time. Ligands binding in the minor groove caused changes in migration time and peak shape which were significantly different from those caused by intercalators.  相似文献   

19.
DNA sequencing with direct blotting electrophoresis.   总被引:10,自引:0,他引:10       下载免费PDF全文
S Beck  F M Pohl 《The EMBO journal》1984,3(12):2905-2909
A method for transferring the DNA molecules of sequencing reaction mixtures onto an immobilizing matrix during electrophoresis has been developed. A blotting membrane moves with constant speed across the end of a very short, denaturing gel and collects the molecules according to size. A constant distance between bands for molecules differing in length by one nucleotide is obtained over a large range (approximately 600 nucleotides with a 5% gel), simplifying the determination of DNA sequences considerably. Reliable sequences of 500 nucleotides can be read and sequence features up to greater than 1000 nucleotides are revealed in a single experiment. The sequencing of a potential Z-DNA-forming fragment from Escherichia coli DNA is given as an example and possible further developments are discussed.  相似文献   

20.
L H Guo  R Wu 《Nucleic acids research》1982,10(6):2065-2084
We describe improve enzymatic methods for sequencing method for sequencing DNA. They are based on partial digestion of duplex DNA with exonuclease III to produce DNA molecules with 3' ends shortened to varying lengths, followed by repair synthesis to extend and label the 3' ends. After asymmetrical cleavage of the DNA with a restriction enzyme, the labeled products are separated by gel electrophoresis and the sequence read from the autoradiogram. The entire procedures, beginning with unrestricted DNA and followed through gel electrophoresis, takes only one day for sequencing both strands of the DNA molecule. These methods are especially suitable for sequencing DNA cloned in plasmid vectors, and they greatly extend the usefulness of the dideoxynucleotide chain termination method of Sanger et al. (Proc. Natl. Acad. Sci. USA 74, 5463, 1977). Using these methods we have determined the sequence of a 410 base pair fragment which includes the yeast SUP3 tyrosine tRNA gene.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏