首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Magnetoresistive-based biosensors and biochips   总被引:5,自引:0,他引:5  
Over the past five years, magnetoelectronics has emerged as a promising new platform technology for biosensor and biochip development. The techniques are based on the detection of the magnetic fringe field of a magnetically labeled biomolecule interacting with a complementary biomolecule bound to a magnetic-field sensor. Magnetoresistive-based sensors, conventionally used as read heads in hard disk drives, have been used in combination with biologically functionalized magnetic labels to demonstrate the detection of molecular recognition. Real-world bio-applications are now being investigated, enabling tailored device design, based on sensor and label characteristics. This detection platform provides a robust, inexpensive sensing technique with high sensitivity and considerable scope for quantitative signal data, enabling magnetoresistive biochips to meet specific diagnostic needs that are not met by existing technologies.  相似文献   

2.
A significant challenge for all biosensor systems is to achieve high assay sensitivity and specificity while minimizing sample preparation requirements, operational complexity, and sample-to-answer time. We have achieved multiplexed, unamplified, femtomolar detection of both DNA and proteins in complex matrices (including whole blood, serum, plasma, and milk) in minutes using as few as two reagents by labeling conventional assay schemes with micrometer-scale magnetic beads, and applying fluidic force discrimination (FFD). In FFD assays, analytes captured onto a microarray surface are labeled with microbeads, and a controlled laminar flow is then used to apply microfluidic forces sufficient to preferentially remove only nonspecifically bound bead labels. The density of beads that remain bound is proportional to the analyte concentration and can be determined with either optical counting or magnetoelectronic detection of the magnetic labels. Combining FFD assays with chip-based magnetoelectronic detection enables a simple, potentially handheld, platform capable of both nucleic acid hybridization assays and immunoassays, including orthogonal detection and identification of bacterial and viral pathogens, and therefore suitable for a wide range of biosensing applications.  相似文献   

3.
A novel affinity biosensor is proposed based on the hybrid plasmonic platform. The proposed biosensor benefits from the high sensitivity of the surface plasmon resonance (SPR), while at the same time, it is capable of performing measurements in both the TM and TE polarizations (p- and s-polarizations). Unlike the conventional SPR biosensors, the polarization diversity of the hybrid sensor allows for decoupling of the bulk index variations in the fluidic channels (due to variations in concentration, decomposition, temperature, and so on) from the surface properties of the attached molecules. Compatibility of the proposed hybrid plasmonic biosensor with standard Si-processing techniques and the simplicity of its design are other advantages of the sensor which makes its fabrication straightforward. The best figure of merit for the biosensor is defined based on the minimum detection limit and a genetic algorithm is used to optimize the device. A method of de-convolving the surface and bulk effects is also discussed.  相似文献   

4.
A novel approach for the label-free detection of molecular interactions is presented in which a colorimetric resonant grating is used as a surface binding platform. The grating, when illuminated with white light, is designed to reflect only a single wavelength. When molecules are attached to the surface, the reflected wavelength (color) is shifted due to the change of the optical path of light that is coupled into the grating. By linking receptor molecules to the grating surface, complementary binding molecules can be detected without the use of any kind of fluorescent probe or radioactive label. The detection technique is capable of detecting the addition and removal of small molecules as they interact with receptor molecules on the sensor surface or enzymes in the solution surrounding the sensor. Two assays are presented to exemplify the detection of small molecule interactions with the biosensor. First, an avidin receptor layer is used to detect 244 Da biotin binding. Second, a protease assay is performed in which a 136 Da p-nitroanilide (pNA) moeity is cleaved from an immobilized substrate. Because the sensor structure can be embedded in the plastic surfaces of microtiter plates or the glass surfaces of microarray slides, it is expected that this technology will be most useful in applications where large numbers of biomolecular interactions are measured in parallel, particularly when molecular labels will alter or inhibit the functionality of the molecules under study. Screening of pharmaceutical compound libraries with protein targets, and microarray screening of protein-protein interactions for proteomics are examples of applications that require the sensitivity and throughput afforded by this approach.  相似文献   

5.
A novel type of magnetic-beads based magnetic biosensor is described for the detection of Yersinia pestis. Experiments were performed with the antigen fraction F1 of these bacteria. The magnetic sensor platform offers easy and reliable detection of Y. pestis by the use of magnetic beads for labelling and quantification in a single step due to their paramagnetic features. The system uses antiYPF1 antibodies as capture element on ABICAP columns as core element of the magnetic sensor. Several immobilization methods for antibodies on polyethylene were exploited. The established biosensor has a linear detection range of 25-300 ng/ml Y. pestis antigen F1 and a detection limit of 2.5 ng/ml in buffer and human blood serum. The presented sensor system is small, simple, portable and therefore usable as off-lab detection unit for medical and warfare analytes.  相似文献   

6.
In this paper, a mediatorless amperometric glucose biosensor based on direct covalent immobilisation of monomolecular layer of glucose oxidase (GOx) on a semiconducting indium-tin oxide (ITO) is demonstrated. The abundance of surface hydroxyl functional group of ITO allows it to be used as a suitable platform for direct covalent immobilisation of the enzyme for sensor architecture. The anodic current corresponding to electrochemical oxidation of the enzymatic product, hydrogen peroxide, at a sputtered Pt electrode at 0.500 V (vs. SCE) was obtained as the sensor signal. It was found that the biosensor based on the direct immobilisation scheme shows a fast biosensor response, minimum interference from other common metabolic species and ease of biosensor miniaturisation. A linear range of 0-10 mM of glucose was demonstrated, which exhibits a high sensitivity as far as performance per immobilised GOx molecule is concerned. A detection limit as low as 0.05 mM and long-term stability were observed. Even more important, the biosensor design allows fabrication through a dry process. These characteristics make it possible to achieve mass production of biosensor compatible with the current electronic integrated circuit manufacturing technologies.  相似文献   

7.
Among the plethora of affinity biosensor systems based on biomolecular recognition and labeling assays, magnetic labeling and detection is emerging as a promising new approach. Magnetic labels can be non-invasively detected by a wide range of methods, are physically and chemically stable, relatively inexpensive to produce, and can be easily made biocompatible. Here we provide an overview of the various approaches developed for magnetic labeling and detection as applied to biosensing. We illustrate the challenges to integrating one such approach into a complete sensing system with a more detailed discussion of the compact Bead Array Sensor System developed at the U.S. Naval Research Laboratory, the first system to use magnetic labels and microchip-based detection.  相似文献   

8.
A novel high sensitivity ZnO/SiO(2)/Si Love mode surface acoustic wave (SAW) biosensor for the detection of interleukin-6 (IL-6), is reported. The biosensors operating at 747.7MHz and 1.586GHz were functionalized by immobilizing the monoclonal IL-6 antibody onto the ZnO biosensor surface both through direct surface adsorption and through covalent binding on gluteraldehyde. The morphology of the IL-6 antibody-protein complex was studied using scanning electron microscopy (SEM), and the mass of the IL-6 protein immobilized on the surface was measured from the frequency shift of the SAW resonator biosensor. The biosensor was shown to have extended linearity, which was observed to improve with higher sensor frequency and for IL-6 immobilization through the monoclonal antibody. Preliminary results of biosensor measurements of low levels of IL-6 in normal human serum are reported. The biosensor can be fully integrated with CMOS Si chips and developed as a portable real time detection system for the interleukin family of proteins in human serum.  相似文献   

9.
Mass-sensitive, magnetoelastic resonance sensors have a characteristic resonant frequency that can be determined by monitoring the magnetic flux emitted by the sensor in response to an applied, time varying, magnetic field. This magnetostrictive platform has a unique advantage over conventional sensor platforms in that measurement is wireless and remote. A biosensor for the detection of Salmonella typhimurium was constructed by immobilizing a polyclonal antibody (the bio-molecular recognition element) onto the surface of a magnetostrictive platform. The biosensor was then exposed to solutions containing S. typhimurium bacteria. Binding between the antibody and antigen (bacteria) occurred and the additional mass of the bound bacteria caused a shift in the sensor's resonant frequency. Sensors with different physical dimensions were exposed to different concentrations of S. typhimurium ranging from 10(2) to 10(9)CFU/ml. Detection limits of 5x10(3) CFU/ml, 10(5) CFU/ml and 10(7) CFU/ml were obtained for sensors with the size of 2 mmx0.4 mmx15 microm, 5 mmx1 mmx15 microm and 25 mmx5 mmx15 microm, respectively. Good agreement between the measured number of bound bacterial cells (as measured by scanning electron microscopy (SEM)) and frequency shifts was obtained.  相似文献   

10.
The BARC biosensor applied to the detection of biological warfare agents   总被引:10,自引:0,他引:10  
The Bead ARray Counter (BARC) is a multi-analyte biosensor that uses DNA hybridization, magnetic microbeads, and giant magnetoresistive (GMR) sensors to detect and identify biological warfare agents. The current prototype is a table-top instrument consisting of a microfabricated chip (solid substrate) with an array of GMR sensors, a chip carrier board with electronics for lock-in detection, a fluidics cell and cartridge, and an electromagnet. DNA probes are patterned onto the solid substrate chip directly above the GMR sensors, and sample analyte containing complementary DNA hybridizes with the probes on the surface. Labeled, micron-sized magnetic beads are then injected that specifically bind to the sample DNA. A magnetic field is applied, removing any beads that are not specifically bound to the surface. The beads remaining on the surface are detected by the GMR sensors, and the intensity and location of the signal indicate the concentration and identity of pathogens present in the sample. The current BARC chip contains a 64-element sensor array, however, with recent advances in magnetoresistive technology, chips with millions of these GMR sensors will soon be commercially available, allowing simultaneous detection of thousands of analytes. Because each GMR sensor is capable of detecting a single magnetic bead, in theory, the BARC biosensor should be able to detect the presence of a single analyte molecule.  相似文献   

11.
This study utilized the radio frequency (RF) technology to develop a multilayered polymeric DNA sensor with the help of gold and magnetic nanoparticles. The flexible polymeric materials, poly (p-xylylene) (Parylene) and polyethylene naphtholate (PEN), were used as substrates to replace the conventional rigid substrates such as glass and silicon wafers. The multilayered polymeric RF biosensor, including the two polymer layers and two copper transmission structure layers, was developed to reduce the total sensor size and further enhance the sensitivity of the biochip in the RF DNA detection. Thioglycolic acid (TGA) was used on the surface of the proposed biochip to form a thiolate-modified sensing surface for DNA hybridization. Gold nanoparticles (AuNPs) and magnetic nanoparticles (MNPs) were used to immobilize on the surface of the biosensor to enhance overall detection sensitivity. In addition to gold nanoparticles, the magnetic nanoparticles has been demonstrated the applicability for RF DNA detection. The performance of the proposed biosensor was evaluated by the shift of the center frequency of the RF biosensor because the electromagnetic characteristic of the biosensors can be altered by the immobilized multilayer nanoparticles on the biosensor. The experimental results show that the detection limit of the DNA concentration can reach as low as 10 pM, and the largest shift of the center frequency with triple-layer AuNPs and MNPs can approach 0.9 and 0.7 GHz, respectively. Such the achievement implies that the developed biosensor can offer an alternative inexpensive, disposable, and highly sensitive option for application in biomedicine diagnostic systems because the price and size of each biochip can be effectively reduced by using fully polymeric materials and multilayer-detecting structures.  相似文献   

12.
Mercury ions (Hg(2+)) are a highly toxic and ubiquitous pollutants requiring rapid and sensitive on-site detection methods in the environment and foods. Herein, we report an envanescent wave DNA-based biosensor for rapid and very sensitive Hg(2+) detection based on a direct structure-competitive detection mode. In this system, a DNA probe covalently immobilized onto a fiber optic sensor contains a short common oligonucleotide sequences that can hybidize with a fluorescently labeled complementary DNA. The DNA probe also comprises a sequence of T-T mismatch pairs that binds with Hg(2+) to form a T-Hg(2+)-T complex by folding of the DNA segments into a hairpin structure. With a structure-competitive mode, a higher concentration of Hg(2+) leads to less fluorescence-labeled cDNA bound to the sensor surface and thus to lower fluorescence signal. The total analysis time for a single sample, including the measurement and surface regeneration, was under 6 min with a Hg(2+) detection limit of 2.1 nM. The high specificity of the sensor was demonstrated by evaluating its response to a number of potentially interfering metal ions. The sensor's surface can be regenerated with a 0.5% SDS solution (pH 1.9) over 100 times with no significant deterioration of performance. This platform is potentially applicable to detect other heavy metal ions or small-molecule analytes for which DNA/aptamers can be used as specific sensing probes.  相似文献   

13.
Li H  Wei Q  He J  Li T  Zhao Y  Cai Y  Du B  Qian Z  Yang M 《Biosensors & bioelectronics》2011,26(8):3590-3595
Ultrasensitive sandwich type electrochemical immunosensors for the detection of cancer biomarker prostate specific antigen (PSA) is described which uses graphene sheet (GS) sensor platform and ferrocene functionalized iron oxide (Fe(3)O(4)) as label. To fabricate the labels, dopamine (DA) was first anchored onto Fe(3)O(4) surface followed by conjugating ferrocene monocarboxylic acid (FC) and secondary-antibody (Ab(2)) onto Fe(3)O(4) through the amino groups of DA (DA-Fe(3)O(4)-FC-Ab(2)). The great amount of DA molecules anchored onto Fe(3)O(4) surface increased the immobilization of FC and Ab(2) onto the Fe(3)O(4) nanoparticle, which in turn increased the sensitivity of the immunosensor. GS used as biosensor platform increased the surface area to capture a great amount of primary antibodies (Ab(1)) and the good conductivity of GS enhanced the detection sensitivity to FC. Using the redox current of FC as signal, the immunosensor displays high sensitivity, wide linear range (0.01-40 ng/mL), low detection limit (2 pg/mL), good reproducibility and stability. In addition, this method could be extended to the immobilization of other interesting materials (fluorescence dyes) onto Fe(3)O(4) for preparing various kinds of labels to meet the different requirements in immunoassays.  相似文献   

14.
An immunomagnetic method for the selective and quantitative detection of biological species by means of a magnetoresistive biosensor and superparamagnetic particles has been optimized. In order to achieve this, a giant magnetoresistive [Co (5.10nm)/Cu (2.47 nm)](20) multilayer structure has been chosen as the sensitive material, showing a magnetoresistance of 3.60% at 215 Oe and a sensitivity up to 0.19 Ω/Oe between 145 Oe and 350 Oe. The outward gold surface of the sensor is biofunctionalized with a Self-Assembled Monolayer (SAM). In addition, three different types of magnetic labels have been tested. 2 μm diameter magnetic carriers (7.68 pg ferrite/particle) have shown the best response and they have induced a shift in the magnetoresistive hysteresis loops up to 9% at 175 Oe.  相似文献   

15.
A wireless sensing device was developed for the in-situ monitoring of the growth of human breast cancer cells (MCF-7) and evaluation of the cytotoxicity of the anticancer drugs fluorouracil and cisplatin. The sensor is fabricated by coating a magnetoelastic ribbon-like sensor with a layer of polyurethane that protects the iron-rich sensor from oxidation and provides a cell-compatible surface. In response to a time-varying magnetic field, the magnetoelastic sensor longitudinally vibrates, emitting magnetic flux that can be remotely detected by a pick-up coil. No physical connections between the sensor and the detection system are required. The wireless property facilitates aseptic biological operation, especially in cell culture as illustrated in this work. The adhesion of cells on the sensor surface results in a decrease in the resonance amplitude, which is proportional to the cell concentration. A linear response was obtained in cell concentrations of 5x10(4) to 1x10(6)cellsml(-1), with a detection limit of 1.2x10(4)cellsml(-1). The adhesion strength of cells on the sensor is qualitatively evaluated by increasing the amplitude of the magnetic excitation field. And the cytotoxicity of the anticancer drugs fluorouracil and cisplatin is evaluated by the magnetoelastic biosensor. The cytostatic curve is related with the quantity of cytostatic drug. The lethal concentration (LC50) for cells incubated in the presence of drugs for 20h is calculated to be 19.9muM for fluorouracil and 13.1muM for cisplatin.  相似文献   

16.
Viruses are of high medical and biodefense concern and their detection at concentrations well below the threshold necessary to cause health hazards continues to be a challenge with respect to sensitivity, specificity, and selectivity. Ideally, assays for accurate and real time detection of viral agents would not necessitate any pre-processing of the analyte, which would make them applicable for example to bodily fluids (blood, sputum) and man-made as well as naturally occurring bodies of water (pools, rivers). We describe herein a robust biosensor that combines the sensitivity of surface acoustic waves (SAW) generated at a frequency of 325MHz with the specificity provided by antibodies for the detection of viral agents. A lithium tantalate-based SAW transducer with silicon dioxide waveguide sensor platform featuring three test and one reference delay lines was used to adsorb antibodies directed against either Coxsackie virus B4 or the category A bioagent Sin Nombre virus (SNV), a member of the genus Hantavirus, family Bunyaviridae, negative-stranded RNA viruses. Rapid detection (within seconds) of increasing concentrations of viral particles was linear over a range of order of magnitude for both viruses, although the sensor was approximately 5 x 10(5)-fold more sensitive for the detection of SNV. For both pathogens, the sensor's selectivity for its target was not compromised by the presence of confounding Herpes Simplex virus type 1. The biosensor was able to detect SNV at doses lower than the load of virus typically found in a human patient suffering from hantavirus cardiopulmonary syndrome (HCPS). Further, in a proof-of-principle real world application, the SAW biosensor was capable to selectively detect SNV agents in complex solutions, such as naturally occurring bodies of water (river, sewage effluent) without analyte pre-processing. This is the first study that reports on the detection of viral agents using an antibody-based SAW biosensor that has the potential to be used as a hand-held and self-contained device for rapid viral detection in the field.  相似文献   

17.

In this work, a label-free and inexpensive method for the monitoring of water pollutants is demonstrated. We introduce a localized surface plasmon resonance (LSPR) based plasmonic capillary optical biosensor to detect microalgae cells. Here, the plasmonic capillary biosensor was prepared by decorating the inner walls of a glass capillary with gold nanoparticles that were employed for investigations. Since the gold nanoparticle has the potential to sense pollutants in water rapidly with high sensitivity and they are expected to perform a significant role in environmental monitoring. Our proposed plasmonic capillary sensor has a detection limit of 25 algal cells (Chlorella sp. CB4). Furthermore, the plasmonic capillary sensing platform significantly simplifies sensor fabrication and reduces the cost of the device. We believe that the presented plasmonic sensor could stand as a potential candidate for developing a cost-effective, label-free, and rapid sensing platform to detect microalgae pollutants present in the water at very low concentrations.

  相似文献   

18.
A fiber optic surface plasmon resonance (SPR) biosensor for detection of Staphylococcal enterotoxin B (SEB) is reported. The sensor is based on spectral interrogation of surface plasmons in a miniature sensing element based on a side-polished single-mode optical fiber with a thin metal overlayer. For specific detection of SEB, the SPR sensor is functionalized with a covalently crosslinked double-layer of antibodies against SEB. The SPR biosensor is demonstrated to be able to detect ng/ml concentrations of SEB in less than 10 min.  相似文献   

19.
High-throughput surface plasmon resonance (SPR) biosensor for rapid and parallelized detection of nucleic acids identifying specific bacterial pathogens is reported. The biosensor consists of a high-performance SPR imaging sensor with polarization contrast and internal referencing (refractive index resolution 2 x 10(-7) RIU) and an array of DNA probes microspotted on the surface of the SPR sensor. It is demonstrated that short sequences of nucleic acids (20-23 bases) characteristic for bacterial pathogens such as Brucella abortus, Escherichia coli, and Staphylococcus aureus can be detected at 100 pM levels. Detection of specific DNA or RNA sequences can be performed in less than 15 min by the reported SPR sensor.  相似文献   

20.

Many environmental applications exist for biosensors capable of providing real-time analyses. One pressing current need is monitoring for agents of chemical- and bio-terrorism. These applications require systems that can rapidly detect small organics including nerve agents, toxic proteins, viruses, spores and whole microbes. A second area of application is monitoring for environmental pollutants. Processing of grab samples through chemical laboratories requires significant time delays in the analyses, preventing the rapid mapping and cleanup of chemical spills. The current state of development of miniaturized, integrated surface plasmon resonance (SPR) sensor elements has allowed for the development of inexpensive, portable biosensor systems capable of the simultaneous analysis of multiple analytes. Most of the detection protocols make use of antibodies immobilized on the sensor surface. The Spreeta 2000 SPR biosensor elements manufactured by Texas Instruments provide three channels for each sensor element in the system. A temperature-controlled two-element system that monitors for six analytes is currently in use, and development of an eight element sensor system capable of monitoring up to 24 different analytes will be completed in the near future. Protein toxins can be directly detected and quantified in the low picomolar range. Elimination of false positives and increased sensitivity is provided by secondary antibodies with specificity for different target epitopes, and by sensor element redundancy. Inclusion of more than a single amplification step can push the sensitivity of toxic protein detection to femtomolar levels. The same types of direct detection and amplification protocols are used to monitor for viruses and whole bacteria or spores. Special protocols are required for the detection of small molecules. Either a competition type assay where the presence of analyte inhibits the binding of antibodies to surface-immobilized analyte, or a displacement assay, where antibodies bound to analyte on the sensor surface are displaced by free analyte, can be used. The small molecule detection assays vary in sensitivity from the low micromolar range to the high picomolar.

  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号