首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A protocol for the quantitative detection of Escherichia coli O157 in raw and concentrated surface waters using immunomagnetic electrochemiluminescence (IM-ECL) was developed and optimized. Three antibody sandwich formats were tested: commercial anti-O157:H7 IM beads, IM beads made in-house with a polyclonal anti-O157:H7 immunoglobulin G (IgG), or IM beads made in-house with a monoclonal anti-O157:H7 IgG coupled with a polyclonal anti-O157:H7 IgG to which an electrochemiluminescent label (TAG) was attached. The monoclonal IM bead-polyclonal TAG format was chosen for optimization because it gave lower background levels and linear regression slopes of ca. 1.0, indicative of a constant ECL signal per cell. The dynamic range was ca. 101 to 105 cells ml−1 in phosphate-buffered saline and in raw water samples. The monoclonal IM beads selectively captured E. coli O157 cells in the presence of ca. 108 cells of a non-O157 strain of E. coli ml−1. Background ECL signals from concentrated (100-fold) water samples were substantially higher and more variable than raw water samples. The background signal was partially eliminated by the addition of polyvinylpolypyrrolidone. Successive cell capture incubations, termed sequential bead capture (SBC), were optimized for establishing baseline ECL values for individual water samples. The linear dynamic range with SBC was ca. 102 to 105 E. coli O157 cells ml of concentrated water−1. To validate the protocol, 10-liter surface water samples were spiked with ca. 5,000 E. coli O157 (Odwalla) cells and concentrated by vortex filtration, and 1- or 3-ml aliquots were analyzed by IM-ECL. Differential ECL signals (SBC) from 1- and 3-ml samples were statistically significant and were generally consistent with standard curves for these cell concentrations. Enrichments were conducted with aliquots of spiked raw water and concentrated water using EC broth and minimal lactose broth (MLB). All tubes with concentrated water became turbid and gave a positive ECL response for E. coli O157 (>10,000 ECL units); MLB gave a somewhat higher detection rate with spiked raw water. The potential sensitivity of the IM-ECL assay is ca. 25 E. coli O157 cells ml of raw water−1, 25 cells 100 ml of 100-fold concentrated water−1, or 1 to 2 viable cells liter−1 with concentration and enrichment. The IM-ECL assay appears suitable for routine analysis and screening of water samples.  相似文献   

2.
We report here the use of immunomagnetic (IM) electrochemiluminescence (ECL) for quantitative detection of Esherichia coli O157:H7 in water samples following enrichment in minimal lactose broth (MLB). IM beads prepared in-house with four commercial anti-O157 monoclonal antibodies were compared for efficiency of cell capture. IM-ECL responses for E. coli O157:H7 (strain SEA13B88) were similar for all four commercial anti-O157 LPS monoclonal antibodies. The ECL signal was linearly correlated with E. coli O157:H7 cell concentration, indicating a constant ECL response per cell. Twenty-two strains of E. coli O157:H7 or O157:NM gave comparable ECL signals using IM beads prepared in-house. To assess the potential for interference from background bacteria in MLB-enriched water samples, 10(4) cells of E. coli O157:H7 (strain SEA13B88) were added to enriched samples prior to analysis. There was considerable variability in recovery of E. coli O157:H7 cells; net ECL signals ranged from 1% to 100% of expected values (i.e., percent inhibition from 0% to 99%). Cultures of Klebsiella pneumoniae, Klebsiella oxytoca, and Enterobacter cloacae, subsequently isolated from MLB-enriched water samples via IM separation (IMS), were observed to interfere with the binding of E. coli O157:H7 cells to IM beads. Recoveries of 10(4) E. coli O157:H7 cells were 相似文献   

3.
The use of a minimal lactose enrichment broth (MLB) in conjunction with immunomagnetic electrochemiluminescence detection (IM-ECL) was evaluated for the estimation of viable Escherichia coli O157 populations in surface water samples. In principle, E. coli O157 populations (C(initial E. coli O157)) can be derived from enrichment data according to the equation: C(initial E. coli O157) = C(initial coliforms) x C(final E. coli O157)/C(final coliforms)), assuming that the growth rates and lag times of water-borne E. coli O157 and collective coliforms are sufficiently comparable, or at least consistent. We have previously described a protocol for determining C(final E. coli O157) in MLB-enriched water samples. In the present study, 80% of coliforms (red/pink colonies on MacConkey Agar) grew in MLB, indicating that this provides reasonably accurate estimates of C(initial coliforms). Estimates of C(final coliforms) were determined from turbidity data. Initial E. coli O157 populations (C(initial E. coli O157)) were calculated for 33 Baltimore watershed samples giving a positive IM-ECL response. The majority of samples contained E. coli O157 concentrations of < 1 cell per 100 ml. These data indicate that E. coli O157 are present in surface water samples but at very low levels. Growth rates for MLB-enriched coliforms were highly variable (k= 0.47 +/- 0.13 h(-1), n= 72). There was no correlation between growth rates and any measured water parameter, suggesting that coliform populations in water samples are spatially and temporally unique. Although variability in growth rates was expected to yield some low values, the fact that most E. coli O157 concentrations were < 1 suggests that other factor(s) were also responsible. Studies with E. coli O157:H7 and wild-type E. coli suggest that increased lag times due to starvation were at least partially responsible for the observed data. Based on estimates of C(initial coliforms) and k(coliforms), MLB was evaluated for sensitivity and quantitativeness. Simulated populations of E. coli O157:H7 at stationary phase varied from ca. 10(3) to 10(8) cells ml(-1) enrichment culture. Although not suitable for quantitation, MLB enrichment in conjunction with IM-ECL can detect as few as one viable water-borne E. coli O157 cell per 100 ml surface water. Experiments are in progress to evaluate alternative media for sensitivity and quantitative detection of enterohemorrhagic E. coli.  相似文献   

4.
Rapid, direct methods are needed to assess active bacterial populations in water and foods. Our objective was to determine the efficiency of bacterial detection by immunomagnetic separation (IMS) and the compatibility of IMS with cyanoditolyl tetrazolium chloride (CTC) incubation to determine respiratory activity, using the pathogen Escherichia coli O157:H7. Counterstaining with a specific fluorescein-conjugated anti-O157 antibody (FAb) following CTC incubation was used to allow confirmation and visualization of bacteria by epifluorescence microscopy. Broth-grown E. coli O157:H7 was used to inoculate fresh ground beef (<17% fat), sterile 0.1% peptone, or water. Inoculated meat was diluted and homogenized in a stomacher and then incubated with paramagnetic beads coated with anti-O157 specific antibody. After IMS, cells with magnetic beads attached were stained with CTC and then an anti-O157 antibody-fluorescein isothiocyanate conjugate and filtered for microscopic enumeration or solid-phase laser cytometry. Enumeration by laser scanning permitted detection of ca. 10 CFU/g of ground beef or <10 CFU/ml of liquid sample. With inoculated meat, the regression results for log-transformed respiring FAb-positive counts of cells recovered on beads versus sorbitol-negative plate counts in the inoculum were as follows: intercept = 1.06, slope = 0.89, and r2 = 0. 95 (n = 13). The corresponding results for inoculated peptone were as follows: intercept = 0.67, slope = 0.88, and r2 = 0.98 (n = 24). Recovery of target bacteria on beads by the IMS-CTC-FAb method, compared with recovery by sorbitol MacConkey agar plating, yielded greater numbers (beef, 6.0 times; peptone, 3.0 times; water, 2.4 times). Thus, within 5 to 7 h, the IMS-CTC-FAb method detected greater numbers of E. coli O157 cells than were detected by plating. The results show that the IMS-CTC-FAb technique with enumeration by either fluorescence microscopy or solid-phase laser scanning cytometry gave results that compared favorably with plating following IMS.  相似文献   

5.
Hemorrhagic Escherichia coli O157:H7 strains and other virulent enteric pathogens can pose a serious health threat in tainted meats, poultry, and even drinking water. Traditional culture-based methods for assay of enteric pathogens in foods and water sources are relatively slow, and results can be ambiguous. Immunomagnetic separation (IMS) and detection methods have been investigated and appear promising for rapid bacterial assay of foods and environmental samples. In this work, a commercial sensor which combines IMS with electrochemiluminescence (ECL) detection is evaluated for detection of E. coli O157 and Salmonella typhimurium in foods and fomites. Results indicate that detection limits are in the range of 100 to 1,000 bacteria per ml in pristine buffer for E. coli O157 and S. typhimurium, respectively, or 1,000 to 2,000 bacteria per ml in food samples (depending on the sample) and that total processing and assay time is rapid (< 1 h) even in food samples. An immunologic "hook" or high-antigen-concentration prozone effect was observed above 10(4) and 10(5) bacteria per ml for E. coli O157 and S. typhimurium, respectively. IMS was accomplished in milk, juices, serum, supernatant fluids from ground beef, finely minced chicken, and fish suspensions as well as several freshwater sources and followed by ECL assay. Some samples, especially fish, gave unexpectedly high background ECL. Conversely, low ECL intensity was observed in nonfat and 2% fat milk samples, which appeared to be related to binding or entrapment of the antibody-coated magnetic beads by particulates in the milk, as revealed by microscopy. Results of this evaluation suggest the feasibility of immunomagnetic-ECL methodology for rapid, sensitive, and facile preliminary screening of various foods and fomites for the presence of virulent enteric pathogens.  相似文献   

6.
AIMS: To apply the real-time Polymerase chain reaction (PCR) method to detect and quantify Escherichia coli O157:H7 in soil, manure, faeces and dairy waste washwater. METHODS AND RESULTS: Soil samples were spiked with E. coli O157:H7 and subjected to a single enrichment step prior to multiplex PCR. Other environmental samples suspected of harbouring E.coli O157:H7 were also analysed. The sensitivity of the primers was confirmed with DNA from E.coli O157:H7 strain 3081 spiked into soil by multiplex PCR assay. A linear relationship was measured between the fluorescence threshold cycle (C T ) value and colony counts (CFU ml(-1)) in spiked soil and other environmental samples. The detection limit for E.coli O157:H7 in the real-time PCR assay was 3.5 x 10(3) CFU ml(-1) in pure culture and 2.6 x 10(4) CFU g(-1) in the environmental samples. Use of a 16-h enrichment step for spiked samples enabled detection of <10 CFU g(-1) soil. E. coli colony counts as determined by the real-time PCR assay, were in the range of 2.0 x 10(2) to 6.0 x 10(5) CFU PCR (-1) in manure, faeces and waste washwater. CONCLUSIONS: The real-time PCR-based assay enabled sensitive and rapid quantification of E. coli O157:H7 in soil and other environmental samples. SIGNIFICANCE AND IMPACT OF THE STUDY: The ability to quantitatively determine cell counts of E.coli O157:H7 in large numbers of environmental samples, represents considerable advancement in the area of pathogen quantification for risk assessment and transport studies.  相似文献   

7.
Immunofluorescence assay (IFA) and immunomagnetic electrochemiluminescence (IM-ECL) were used for comparison of the percent recovery of Cryptosporidium parvum in environmental water samples obtained from a spring draining a karst basin. The monoclonal antibodies to C. parvum, isotype IgG3 were used for optimization of the IM-ECL protocol. The combination of biotinylated and TAG-labeled anti-C. parvum antibodies with the streptavidin beads gave a linear regression slope for log ECL vs. log fresh oocysts of 0.79 (from 5 to 5,000 oocysts), which indicates a constant ECL signal per oocyst. Standard curves gave a dynamic range of 5 to 5,000 oocysts/ml (fresh) and 10 to 100,000 cells/ml (4-month-old oocysts) with the maximum limit of linear detection higher than 100,000. The linear slope of 4-month-old oocysts decreased to 0.62, which indicates that ECL signal is a function of oocyst age. The experiment associated with bead storage time shows that even after 4 months of storage of the biotinylated antibodies, the complex retains the ability for binding the oocysts and generating the ECL signal. Based on the IFA results in the experiment evaluating different protocols for oocysts recovery from karst water samples, the most efficient protocol involved dispersion, followed by flotation and immunomagnetic separation (IMS) (24% recovery). The ECL results obtained in that experiment were very similar to the results obtained in the IFA method, which indicates that the IM-ECL method is accurate. Results of the IFA in the study of the prevalence of C. parvum in the groundwater showed that oocysts were present in 78% of 1 L water samples with average number of oocysts of 6.4+/-5.5 and ranged from 0 (13 samples) to 23.3 (2 samples). The ECL signal generated from these water samples ranged from 3,771 to 622 (average 1,620+/-465). However, the background value estimated in groundwater samples with low number of oocysts detected by IFA was highly variable and elevated (from 3,702 to 272, average 1,503+/-475). The background value as a result of nonspecific binding to beads by unidentified organic components in the water can inhibit or even completely mask the signal generated by oocysts. Our investigations showed that the IM-ECL method appears to be promising for the qualitative and quantitative detection of C. parvum from the environmental water; however, the method requires further development to improve sensitivity and account for background signals.  相似文献   

8.
An immunoassay based on immunomagnetic separation and time-resolved fluorometry was developed for the detection of E. coli O157:H7 in apple cider. The time-resolved fluorescent immunoassay (TRFIA) uses a polyclonal antibody bound to immunomagnetic beads as the capture antibody and the same antibody labeled with europium as the detection antibody. Cell suspensions of 10(1) to 10(8) E. coli O157:H7 and K-12 organisms per ml were used to test the sensitivity and specificity of the assay. The sensitivity of the assay was 10(3) E. coli O157:H7 cells with no cross-reaction with K-12. Pure cultures of E. coli O157:H7 (10(1) to 10(5) CFU/ml) in apple cider could be detected within 6 h, including 4 h for incubation in modified EC broth with novobiocin and 2 h for the immunoassay. When apple cider was spiked with 1 to 10(3) CFU/ml of E. coli O157:H7 and 10(6) CFU/ml of K-12, our data show that the high level of K-12 in apple cider did not impede the detection of low levels of O157:H7. The minimum detectable numbers of cells present in the initial inoculum were 10(2) and 10(1) CFU/ml after 4- and 6-h enrichment. The TRFIA provides a rapid and sensitive means of detecting E. coli O157:H7 in apple cider.  相似文献   

9.
Fifty-four of 310 (17%) samples of raw beef products contained Vero cytotoxin (VT)-producing Escherichia coli (VTEC) detected by DNA probes for the VT genes. VTEC strains examined in detail from a selection of the positive samples belonged to several O serogroups, some of which have been associated with human diarrhoea or haemolytic uraemic syndrome. Some of the strains possessed properties that may contribute to virulence in man. None of the food samples contained VT-producing E. coli O157 when tested by a combination of VT probe tests and colony immunoblotting with commercially available anti-O157 serum. Quantification of the immunoblotting technique indicated that O157 VTEC could be recovered from artificially-inoculated meat samples at a level of less than one organism per gram. Five of the food samples carried E. coli O157 strains that did not produce VT and differed in other properties from O157 VTEC.  相似文献   

10.
AIMS: To evaluate the suitability of a multiplex PCR-based assay for sensitive and rapid detection of Escherichia coli O157:H7 in soil and water. METHODS AND RESULTS: Soil and water samples were spiked with E. coli O157:H7 and subjected to two stages of enrichment prior to multiplex PCR. Detection sensitivities were as high as 1 cfu ml(-1) drinking water and 2 cfu g(-1) soil. Starvation of E. coli O157:H7 for 35 d prior to addition to soil did not affect the ability of the assay to detect initial cell numbers as low as 10 cfu g(-1) soil. Use of an 8-h primary enrichment enabled detection of as few as 6 cfu g(-1) soil, and 10(4) cfu g(-1) soil with a 6-h primary enrichment. When soil was inoculated with 10(5) cfu g(-1), the PCR assay indicated persistence of E. coli O157:H7 during a 35 d incubation. However, when soil was inoculated with lower numbers of pathogen, PCR amplification signals indicated survival to be dependent on cell concentration. CONCLUSIONS: A multiplex PCR-based assay, in combination with an enrichment strategy enabled sensitive and rapid detection of E. coli O157:H7 in soil and water. SIGNIFICANCE AND IMPACT OF THE STUDY: The ability to sensitively detect E.coli O157:H7 in environmental material within one working day represents a considerable advancement over alternative more time-consuming methods for detection of this pathogen.  相似文献   

11.
A sensitive and easy-to-perform instrumentational method for the detection of Escherichia coli O157 in raw minced beef is described. The detection is based on a light scattering immunoassay and a charge-coupled device (CCD) direct readout spectrometer measuring the scattered light spectral signals at an optimized angle of 20° to the axis of transmitted light. Using latex particles coated with antibodies for E. coli O157, the method sensitivity has significantly improved comparing with the visual immunoassay assessment method when detecting the presence of this bacterium in spiked beef samples. The method is capable of detecting E. coli O157 at the level of 103 cfu mL-1 after 6 h of incubation of the spiked samples. This study has demonstrated a faster technique (within 8 h) for the detection of E. coli O157 in raw beef and a possible new application for the CCD based light scattering instrument.  相似文献   

12.
Rapid, direct methods are needed to assess active bacterial populations in water and foods. Our objective was to determine the efficiency of bacterial detection by immunomagnetic separation (IMS) and the compatibility of IMS with cyanoditolyl tetrazolium chloride (CTC) incubation to determine respiratory activity, using the pathogen Escherichia coli O157:H7. Counterstaining with a specific fluorescein-conjugated anti-O157 antibody (FAb) following CTC incubation was used to allow confirmation and visualization of bacteria by epifluorescence microscopy. Broth-grown E. coli O157:H7 was used to inoculate fresh ground beef (<17% fat), sterile 0.1% peptone, or water. Inoculated meat was diluted and homogenized in a stomacher and then incubated with paramagnetic beads coated with anti-O157 specific antibody. After IMS, cells with magnetic beads attached were stained with CTC and then an anti-O157 antibody-fluorescein isothiocyanate conjugate and filtered for microscopic enumeration or solid-phase laser cytometry. Enumeration by laser scanning permitted detection of ca. 10 CFU/g of ground beef or <10 CFU/ml of liquid sample. With inoculated meat, the regression results for log-transformed respiring FAb-positive counts of cells recovered on beads versus sorbitol-negative plate counts in the inoculum were as follows: intercept = 1.06, slope = 0.89, and r2 = 0.95 (n = 13). The corresponding results for inoculated peptone were as follows: intercept = 0.67, slope = 0.88, and r2 = 0.98 (n = 24). Recovery of target bacteria on beads by the IMS-CTC-FAb method, compared with recovery by sorbitol MacConkey agar plating, yielded greater numbers (beef, 6.0 times; peptone, 3.0 times; water, 2.4 times). Thus, within 5 to 7 h, the IMS-CTC-FAb method detected greater numbers of E. coli O157 cells than were detected by plating. The results show that the IMS-CTC-FAb technique with enumeration by either fluorescence microscopy or solid-phase laser scanning cytometry gave results that compared favorably with plating following IMS.  相似文献   

13.
AIMS: To compare media used in immunomagnetic separation (IMS) techniques for the isolation of Escherichia coli O157 from food. METHODS AND RESULTS: Foods, both naturally contaminated and spiked, with low numbers (< 1 g(-1)) of stressed E. coli O157 were enriched in media based on buffered peptone water (BPW), tryptone soya and EC broths incubated at 30, 37, 40 and 42 degrees C. Following immunomagnetic separation, beads were plated on a range of selective agars. CONCLUSION: BPW supplemented with vancomycin (8 mg l(-1)) incubated at 42 degrees C, followed by IMS and subsequent plating of immunobeads onto cefixime tellurite sorbitol MacConkey agar plus either Rainbow or CHROMagar agars, proved optimum for the recovery of spiked, stressed E. coli O157 in minced beef, cheese, apple juice and pepperoni. The same protocol was optimum for recovery from naturally-contaminated minced beef and cheese. SIGNIFICANCE AND IMPACT OF THE STUDY: The optimum protocol would increase isolation rates of E. coli O157 from foods.  相似文献   

14.
The objective of this study was to develop and optimize a protocol for the rapid detection of Escherichia coli O157:H7 in aqueous samples by a combined immunomagnetic bead-immunoliposome (IMB/IL) fluorescence assay. The protocol consisted of the filtration or centrifugation of 30- to 100-ml samples followed by incubation of the filter membranes or pellet with anti-E. coli O157:H7 immunomagnetic beads in growth medium specific for E. coli O157:H7. The resulting E. coli O157:H7-immunomagnetic bead complexes were isolated by magnetic separation, washed, and incubated with sulforhodamine B-containing immunoliposomes specific for E. coli O157:H7; the final immunomagnetic bead-E. coli O157:H7-immunoliposome complexes were again isolated by magnetic separation, washed, and lysed with a n-octyl-beta-d-glucopyranoside to release sulforhodamine B. The final protocol took less than 8 h to complete and had a detection limit of less than 1 CFU of E. coli O157:H7 per ml in various aqueous matrices, including apple juice and cider. To validate the protocol at an independent facility, 100-ml samples of groundwater with and without E. coli O157:H7 (15 CFU) were analyzed by a public health laboratory using the optimized protocol and a standard microbiological method. While the IMB/IL fluorescence assay was able to identify E. coli O157:H7-containing samples with 100% accuracy, the standard microbiological method was unable to distinguish E. coli O157:H7-spiked samples from negative controls without further extensive workup. These results demonstrate the feasibility of using immunomagnetic beads in combination with sulforhodamine B-encapsulating immunoliposomes for the rapid detection of E. coli O157:H7 in aqueous samples.  相似文献   

15.
A solid phase fluorescence-based immunoassay was developed for the detection of Escherichia coli O157:H7 using an antigen down competition format. A soft glass capillary tube served as the solid support, to which heat-killed E. coli O157:H7 were adsorbed. Polyclonal anti- E. coli O157:H7 antibody, conjugated with biotin, was used and the bound antigen-antibody complex was detected using avidin molecules labelled with Cy5, a fluorescent cyanine dye. Any E. coli O157:H7 in the sample would compete with the formation of this complex, reducing fluorescence. This assay was tested for sensitivity with spiked ground beef and apple cider samples. The minimum detectable number of cells present in the initial inoculum was calculated to be approximately 1 colony-forming unit (cfu) per 10g of ground beef when samples were enriched in modified EC broth for 7 h at 37°C. The minimum detectable number of cells for the apple cider samples was calculated to be ∼0.5 cfu ml-1 The E. coli cells in the cider samples were captured with immunomagnetic beads, incubated for 7 h in the enrichment broth, and detected with the solid phase fluorescence immunoassay.  相似文献   

16.
An antibody-direct epifluorescent filter technique (Ab-DEFT) detected 100% of the raw ground beef samples inoculated with Escherichia coli O157 : H7 cells (0·15 cells g−1) and incubated in a prewarmed, modified buffered peptone water (mBPW) non-selective enrichment broth for 5 h at 42°C in an orbital shaking water bath (200 rev min−1). Over 50% of the microscopic fields viewed were positive (1–10 fluorescent cells field−1) in the Ab-DEFT. All positive screening results were confirmed within 24 h by subjecting 1 ml of the mBPW to the Dynabeads® anti- E. coli O157 immunomagnetic separation procedure, followed by plating on MacConkey sorbitol agar containing 5-bromo-4-chloro-3-indolyl-β- D -glucuronide. At this cell concentration, 41·7% of the inoculated samples were detected by the conventional method involving a 24-h selective enrichment. Exposure to viable cells before filtration was minimized by using a 0·58% formaldehyde concentration for 5 min at 50°C (killed >4·00 logs of E. coli O157 : H7 cells) without affecting cell fluorescence.  相似文献   

17.
A time-resolved fluorescence technique was developed to detect Escherichia coli O157:H7 in ground beef burger. After a 4.5 h enrichment period, streptavidin coated magnetic beads conjugated with biotin-labeled anti E. coli O157:H7 were used to capture the bacteria. The bacteria were, at the same time, also labeled by a nonfluorescent, europium (Eu)-tagged anti-E. coli O157:H7 antibody. The sandwiched bacterial complexes were then concentrated using a magnetic particle concentrator and washed to remove other solution components. Upon addition of an enhancement buffer, the Eu-labels were then released from the antibodies and chelated to nitrilo-triacetic acid (NTA) and trioctylphosphine oxide (TOPO) to form highly fluorescent Eu-(2-NTA)3(TOPO)2–3 micellar complexes. Delayed fluorescence associated with these complexes was measured and its intensity was used to estimate the original bacterial concentration spiked in hamburger. This approach was applied to detect E. coli O157:H7 spiked in hamburgers. The results indicated this method is able to detect 1 CFU/g of the bacteria after a brief enrichment for four and half hours at 37C. Specificity studies indicated that the approach exhibited no or limited cross reactivity to Salmonella typhimurium, E. coli K-12 or Shigella dysenteriae spiked in hamburgers. Thus, the developed approach may be used as a rapid screening procedure for E. coli O157 bacteria in foods.  相似文献   

18.
Surface water and groundwater are continuously used as sources of drinking water in many metropolitan areas of the United States. The quality of water from these sources may be reduced due to increases in contaminants such as Escherichia coli from urban and agricultural runoffs. In this study, a multiplex fluorogenic PCR assay was used to quantify E. coli O157:H7 in soil, manure, cow and calf feces, and dairy wastewater in an artificial wetland. Primers and probes were designed to amplify and quantify the Shiga-like toxin 1 (stx1) and 2 (stx2) genes and the intimin (eae) gene of E. coli O157:H7 in a single reaction. Primer specificity was confirmed with DNA from 33 E. coli O157:H7 and related strains with and without the three genes. A direct correlation was determined between the fluorescence threshold cycle (C(T)) and the starting quantity of E. coli O157:H7 DNA. A similar correlation was observed between the C(T) and number of CFU per milliliter used in the PCR assay. A detection limit of 7.9 x 10(-5) pg of E. coli O157:H7 DNA ml(-1) equivalent to approximately 6.4 x 10(3) CFU of E. coli O157:H7 ml(-1) based on plate counts was determined. Quantification of E. coli O157:H7 in soil, manure, feces, and wastewater was possible when cell numbers were >/=3.5 x 10(4) CFU g(-1). E. coli O157:H7 levels detected in wetland samples decreased by about 2 logs between wetland influents and effluents. The detection limit of the assay in soil was improved to less than 10 CFU g(-1) with a 16-h enrichment. These results indicate that the developed PCR assay is suitable for quantitative determination of E. coli O157:H7 in environmental samples and represents a considerable advancement in pathogen quantification in different ecosystems.  相似文献   

19.
The use of commercial anti- Escherichia coli O157-labelled magnetic beads was investigated to improve detection of E. coli O157 by immunomagnetic separation (IMS) from a range of environments on a dairy farm. Immunomagnetic separation proved effective for separation of target cells from laboratory mixtures and during stress in sterile and non-sterile pond water. The IMS procedure was possible with a range of samples (water, faeces, slurry, grass and soil). Non-specific binding of non-target bacterial cells proved problematic in a number of sample types. However, indigenous E. coli O157 cells were detected from samples with a high faecal load, and only with use of IMS. Data on the probable survival and spread of the organism around the farm environment are also discussed.  相似文献   

20.
Escherichia coli O157:H7, a major foodborne pathogen, has been associated with numerous cases of foodborne illnesses. Rapid methods have been developed for the screening of this pathogen in foods in order to circumvent timely plate culture techniques. Unfortunately, many rapid methods are presumptive and do not claim to confirm the presence of E. coli O157:H7. The previously developed method, enzyme-linked immunomagnetic chemiluminescence (ELIMCL), has been improved upon to allow for fewer incidences of false positives when used to detect E. coli O157:H7 in the presence of mixed cultures. The key feature of this assay is that it combines the highly selective synergism of both anti-O157 and anti-H7 antibodies in the sandwich immunoassay format. This work presents application of a newly semi-automated version of ELIMCL to the detection of E. coli O157:H7 in pristine buffered saline yielding detection limits of approximately 1 x 10(5) to 1 x 10(6) of live cells/mL. ELIMCL was further demonstrated to detect E. coli O157:H7 inoculated into artificially contaminated ground beef at ca. 400 CFU/g after a 5 h enrichment and about 1.5 h assay time for a total detection time of about 6.5 h. Finally, ELIMCL was compared with USFDA's Bacteriological Analytical Manual method for E. coli O157:H7 in a double-blind study. Using McNemar's treatment, the two methods were determined to be statistically similar for the detection of E. coli O157:H7 in ground beef inoculated with mixed cultures of select bacteria.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号