首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 422 毫秒
1.

Background

The pulmonary residence time of inhaled glucocorticoids as well as their rate and extend of absorption into systemic circulation are important facets of their efficacy-safety profile. We evaluated a novel approach to elucidate the pulmonary absorption of an inhaled glucocorticoid. Our objective was to monitor and compare the combined process of drug particle dissolution, pro-drug activation and time course of initial distribution from human lung tissue into plasma for two different glucocorticoid formulations.

Methods

We chose beclomethasone dipropionate (BDP) delivered by two different commercially available HFA-propelled metered dose inhalers (Sanasthmax®/Becloforte™ and Ventolair®/Qvar™). Initially we developed a simple dialysis model to assess the transfer of BDP and its active metabolite from human lung homogenate into human plasma. In a novel experimental setting we then administered the aerosols into the bronchus of an extracorporally ventilated and reperfused human lung lobe and monitored the concentrations of BDP and its metabolites in the reperfusion fluid.

Results

Unexpectedly, we observed differences between the two aerosol formulations Sanasthmax®/Becloforte™ and Ventolair®/Qvar™ in both the dialysis as well as in the human reperfusion model. The HFA-BDP formulated as Ventolair®/Qvar™ displayed a more rapid release from lung tissue compared to Sanasthmax®/Becloforte™. We succeeded to explain and illustrate the observed differences between the two aerosols with their unique particle topology and divergent dissolution behaviour in human bronchial fluid.

Conclusion

We conclude that though the ultrafine particles of Ventolair®/Qvar™ are beneficial for high lung deposition, they also yield a less desired more rapid systemic drug delivery. While the differences between Sanasthmax®/Becloforte™ and Ventolair®/Qvar™ were obvious in both the dialysis and lung perfusion experiments, the latter allowed to record time courses of pro-drug activation and distribution that were more consistent with results of comparable clinical trials. Thus, the extracorporally reperfused and ventilated human lung is a highly valuable physiological model to explore the lung pharmacokinetics of inhaled drugs.  相似文献   

2.

Background

High incidence of septic patients increases the pressure of faster and more reliable bacterial identification methods to adapt patient management towards focused and effective treatment options. The aim of this study was to assess two automated DNA extraction solutions with the PCR and microarray-based assay to enable rapid and reliable detection and speciation of causative agents in the diagnosis of sepsis.

Methodology/Principal Findings

We evaluated two automated DNA instruments NucliSENS® easyMAG® and NorDiag Arrow for the preparation of blood culture samples. A set of 91 samples flagged as positive during incubation was analyzed prospectively with the high-throughput generation of Prove-it™ Sepsis assay designed to identify over 60 Gram-negative and Gram-positive bacterial species as well as methicillin resistance marker from a blood culture. Bacterial findings were accurately reported from 77 blood culture samples, whereas 14 samples were reported as negative, containing bacteria not belonging to the pathogen panel of the assay. No difference was observed between the performance of NorDiag Arrow or NucliSENS® easyMAG® with regard to the result reporting of Prove-it™ Sepsis. In addition, we also assessed the quality and quantity of DNA extracted from the clinical Escherichia coli isolate with DNA extraction instruments. We observed only minor differences between the two instruments.

Conclusions

Use of automated and standardized sample preparation methods together with rapid, multiplex pathogen detection offers a strategy to speed up reliably the diagnostics of septic patients. Both tested DNA extraction devices were shown to be feasible for blood culture samples and the Prove-it™ Sepsis assay, providing an accurate identification of pathogen within 4,5 hours when the detected pathogen was in the repertoire of the test.  相似文献   

3.

Background

Mycobacterium bovis is the aetiological agent of bovine tuberculosis (bTB), an important recrudescent zoonosis, significantly increasing in British herds in recent years. Wildlife reservoirs have been identified for this disease but the mode of transmission to cattle remains unclear. There is evidence that viable M. bovis cells can survive in soil and faeces for over a year.

Methodology/Principal Findings

We report a multi-operator blinded trial for a rigorous comparison of five DNA extraction methods from a variety of soil and faecal samples to assess recovery of M. bovis via real-time PCR detection. The methods included four commercial kits: the QIAamp Stool Mini kit with a pre-treatment step, the FastDNA® Spin kit, the UltraClean™ and PowerSoil™ soil kits and a published manual method based on phenol:chloroform purification, termed Griffiths. M. bovis BCG Pasteur spiked samples were extracted by four operators and evaluated using a specific real-time PCR assay. A novel inhibition control assay was used alongside spectrophotometric ratios to monitor the level of inhibitory compounds affecting PCR, DNA yield, and purity. There were statistically significant differences in M. bovis detection between methods of extraction and types of environmental samples; no significant differences were observed between operators. Processing times and costs were also evaluated. To improve M. bovis detection further, the two best performing methods, FastDNA® Spin kit and Griffiths, were optimised and the ABI TaqMan environmental PCR Master mix was adopted, leading to improved sensitivities.

Conclusions

M. bovis was successfully detected in all environmental samples; DNA extraction using FastDNA® Spin kit was the most sensitive method with highest recoveries from all soil types tested. For troublesome faecal samples, we have used and recommend an improved assay based on a reduced volume, resulting in detection limits of 4.25×105 cells g−1 using Griffiths and 4.25×106 cells g−1 using FastDNA® Spin kit.  相似文献   

4.
Gray JG  Dudas S  Czub S 《PloS one》2011,6(3):e17633
Bovine spongiform encephalopathy (BSE) surveillance programs have been employed in numerous countries to monitor BSE prevalence and to protect animal and human health. Since 1999, the European Commission (EC) authorized the evaluation and approval of 20 molecular based tests for the rapid detection of the pathological prion protein (PrPsc) in BSE infection. The diagnostic sensitivity, convenience, and speed of these tests have made molecular diagnostics the preferred method for BSE surveillance. The aim of this study was to determine the analytical sensitivity of 4 commercially available BSE rapid-test kits, including the Prionics®-Check WESTERN, the Prionics® Check-PrioSTRIP™, the BioRad® TeSeE™ ELISA, and the IDEXX® HerdChek™ EIA. Performances of these tests were then compared to 2 confirmatory tests, including the BioRad® TeSeEWestern Blot and the modified Scrapie Associated Fibrils (SAF)/OIE Immunoblot. One 50% w/v homogenate was made from experimentally generated C-type BSE brain tissues in ddH2O. Homogenates were diluted through a background of BSE-negative brainstem homogenate. Masses of both positive and negative tissues in each dilution were calculated to maintain the appropriate tissue amounts for each test platform. Specific concentrated homogenization buffer was added accordingly to maintain the correct buffer condition for each test. ELISA-based tests were evaluated using their respective software/detection platforms. Blot-protocols were evaluated by manual measurements of blot signal density. Detection limitations were determined by fitted curves intersecting the manufacturers'' positive/negative criteria. The confirmatory SAF Immunoblot displayed the highest analytical sensitivity, followed by the IDEXX® HerdChek™ EIA, Bio-Rad® TeSeEWestern Blot, the Bio-Rad® TeSeE™ ELISA, Prionics®-Check PrioSTRIP™, and Prionics®-Check WESTERN™, respectively. Although the tests performed at different levels of sensitivity, the most sensitive and least sensitive of the rapid tests were separated by 2 logs in analytical sensitivity, meeting European performance requirements. All rapid tests appear suitable for targeted BSE surveillance programs, as implemented in Canada.  相似文献   

5.

Aim/background

To evaluate how the use of volumetric-modulated arc therapy (VMAT) with RapidArc® can improve treatment delivery efficiency based on the analysis of the beam-on times and monitor units (MU) needed to deliver therapy for multiple clinical applications in a large patient population.

Materials and methods

A total of 898 treatment courses were delivered in 745 patients treated from October 2008 to March 2013 using RapidArc® treatment plans generated in Eclipse™ TPS. All patients were treated with curative or palliative intent using different techniques including conventional fractionation (83%) and radiosurgery or SBRT (17%), depending on the clinical indications. Treatment delivery was evaluated based on measured beam-on time and recorded MU values delivered on a Varian Trilogy™ linear accelerator.

Results

For conventional fractionation treatments using RapidArc®, the delivery times ranged from 38 s to 4 min and 40 s (average 2 min and 6 s). For radiosurgical treatments the delivery times ranged from 1 min and 42 s to 9 min and 22 s (average 4 min and 4 s). The average number of MU per Gy was 301 for the entire group, with 285 for the conventional group and 317 for the radiosurgical group.

Conclusions

In this study with a large heterogeneous population, treatments using RapidArc® were delivered with substantially less beam-on time and fewer MUs than conventional fractionation. This was highly advantageous, increasing flexibility of the scheduling allowing treatment of radiosurgery patients during the regular daily work schedule. Additionally, reduction of leakage radiation dose was achieved.  相似文献   

6.

Background

Better delivery systems are needed for routinely used vaccines, to improve vaccine uptake. Many vaccines contain alum or alum based adjuvants. Here we investigate a novel dry-coated densely-packed micro-projection array skin patch (Nanopatch™) as an alternate delivery system to intramuscular injection for delivering an alum adjuvanted human papillomavirus (HPV) vaccine (Gardasil®) commonly used as a prophylactic vaccine against cervical cancer.

Methodology/Principal Findings

Micro-projection arrays dry-coated with vaccine material (Gardasil®) delivered to C57BL/6 mouse ear skin released vaccine within 5 minutes. To assess vaccine immunogenicity, doses of corresponding to HPV-16 component of the vaccine between 0.43±0.084 ng and 300±120 ng (mean ± SD) were administered to mice at day 0 and day 14. A dose of 55±6.0 ng delivered intracutaneously by micro-projection array was sufficient to produce a maximal virus neutralizing serum antibody response at day 28 post vaccination. Neutralizing antibody titres were sustained out to 16 weeks post vaccination, and, for comparable doses of vaccine, somewhat higher titres were observed with intracutaneous patch delivery than with intramuscular delivery with the needle and syringe at this time point.

Conclusions/Significance

Use of dry micro-projection arrays (Nanopatch™) has the potential to overcome the need for a vaccine cold chain for common vaccines currently delivered by needle and syringe, and to reduce risk of needle-stick injury and vaccine avoidance due to the fear of the needle especially among children.  相似文献   

7.

Background

The LightCycler® Mycobacterium Detection Kit based on real-time PCR technology for the detection of Mycobacterium tuberculosis, Mycobacterium avium and Mycobacterium kansasii was recently developed. This study evaluated its analytical sensitivity, specificity and reproducibility.

Methodology/Principal Findings

Plasmid standards were prepared and used to determine the limit of detection. The assay was also performed against organisms other than mycobacteria, other mycobacterial strains and interfering substances to exclude cross-reactivity and interference. Reference standards were prepared and tested to assess the assay''s reproducibility. All PCR assays were performed using the LightCycler® 2.0 Instrument. The detection limit for M. tuberculosis was 28 copies per microlitre. Neither cross-reactivity nor interference occurred with non-mycobacterial organisms and substances tested. Overall reproducibility for consecutive measurements, run-to-run, lot-to-lot, day-to-day and laboratory-to-laboratory achieved a coefficient of variance of less than two percent.

Significance

The LightCycler® Mycobacterium Detection kit has shown to be a robust and accurate assay with the potential to be used as a rapid TB diagnostic test.  相似文献   

8.

Background

Video-games have become an integral part of the new multimedia culture. Several studies assessed video-gaming enhancement of spatial attention and eye-hand coordination. Considering the technical difficulty of laparoscopic procedures, legal issues and time limitations, the validation of appropriate training even outside of the operating rooms is ongoing. We investigated the influence of a four-week structured Nintendo® Wii™ training on laparoscopic skills by analyzing performance metrics with a validated simulator (Lap Mentor™, Simbionix™).

Methodology/Principal Findings

We performed a prospective randomized study on 42 post-graduate I–II year residents in General, Vascular and Endoscopic Surgery. All participants were tested on a validated laparoscopic simulator and then randomized to group 1 (Controls, no training with the Nintendo® Wii™), and group 2 (training with the Nintendo® Wii™) with 21 subjects in each group, according to a computer-generated list. After four weeks, all residents underwent a testing session on the laparoscopic simulator of the same tasks as in the first session. All 42 subjects in both groups improved significantly from session 1 to session 2. Compared to controls, the Wii group showed a significant improvement in performance (p<0.05) for 13 of the 16 considered performance metrics.

Conclusions/Significance

The Nintendo® Wii™ might be helpful, inexpensive and entertaining part of the training of young laparoscopists, in addition to a standard surgical education based on simulators and the operating room.  相似文献   

9.

Background and Aims

We aimed to determine the best algorithms for the diagnosis of significant fibrosis in chronic hepatitis C (CHC) patients using all available parameters and tests.

Patients and Methods

We used the database from our study of 507 patients with histologically proven CHC in which fibrosis was evaluated by liver biopsy (Metavir) and tests: Fibrometer®, Fibrotest®, Hepascore®, Apri, ELFG, MP3, Forn''s, hyaluronic acid, tissue inhibitor of metalloproteinase-1 (TIMP1), MMP1, collagen IV and when possible Fibroscan™. For the first test we used 90% negative predictive value to exclude patients with F≤1, next an induction algorithm was applied giving the best tests with at least 80% positive predictive value for the diagnosis of F≥2. The algorithms were computed using the R Software C4.5 program to select the best tests and cut-offs. The algorithm was automatically induced without premises on the part of the investigators. We also examined the inter-observer variations after independent review of liver biopsies by two pathologists. A medico-economic analysis compared the screening strategies with liver biopsy.

Results

In “intention to diagnose” the best algorithms for F≥2 were Fibrometer ®, Fibrotest®, or Hepascore® in first intention with the ELFG score in second intention for indeterminate cases. The percentage of avoided biopsies varied between 50% (Fibrotest® or Fibrometer®+ELFG) and 51% (Hepascore®+ELFG). In “per-analysis” Fibroscan™+ELFG avoided liver biopsy in 55% of cases. The diagnostic performance of these screening strategies was statistically superior to the usual combinations (Fibrometer® or Fibrotest®+Fibroscan™) and was cost effective. We note that the consensual review of liver biopsies between the two pathologists was mainly in favor of F1 (64–69%).

Conclusion

The ELFG test could replace Fibroscan in most currently used algorithms for the diagnosis of significant fibrosis including for those patients for whom Fibroscan™ is unusable.  相似文献   

10.
11.

Objective

The objective of this study was to evaluate the intra-examiner and inter-examiner reproducibility of paraspinal thermography using an infrared scanner.

Materials and Methods

The thermal functions of a commercially available infrared scanner (Insight Subluxation Station®) were evaluated for clinical reliability. Two practicing clinicians conducted the measures on 100 subjects. Intra class correlation coefficients (ICCs) and concordance correlation coefficients (CCCs) were calculated from the collected data.

Results

Mean bilateral paraspinal skin temperature was 89.78° F and ranged from 88.77° F to 91.43° F. Intra class correlation coefficients (ICCs) for agreement and consistency ranged from 0.959 to 0.976. Concordance correlation coefficients (CCCs) ranged from 0.783 to 0.859 with tight confidence intervals indicating robust estimates of these quantities.

Conclusion

This study revealed excellent intra-examiner and inter-examiner reproducibility of paraspinal thermography using a commercially available unit.  相似文献   

12.
13.
14.
15.
Huang X  Guo Y  Bao C  Shen N 《PloS one》2011,6(7):e21671

Introduction

Dysregulated cytokine action on immune cells plays an important role in the initiation and progress of systemic lupus erythematosus (SLE), a complex autoimmune disease. Comprehensively quantifying basal STATs phosphorylation and their signaling response to cytokines should help us to better understand the etiology of SLE.

Methods

Phospho-specific flow cytometry was used to measure the basal STAT signaling activation in three immune cell types of peripheral-blood mononuclear cells from 20 lupus patients, 9 rheumatoid arthritis (RA) patients and 13 healthy donors (HDs). A panel of 27 cytokines, including inflammatory cytokines, was measured with Bio-Plex™ Human Cytokine Assays. Serum Prolactin levels were measured with an immunoradiometric assay. STAT signaling responses to inflammatory cytokines (interferon α [IFNα], IFNγ, interleukin 2 [IL2], IL6, and IL10) were also monitored.

Results

We observed the basal activation of STAT3 in SLE T cells and monocytes, and the basal activation of STAT5 in SLE T cells and B cells. The SLE samples clustered into two main groups, which were associated with the SLE Disease Activity Index 2000, their erythrocyte sedimentation rate, and their hydroxychloroquine use. The phosphorylation of STAT5 in B cells was associated with cytokines IL2, granulocyte colony-stimulating factor (G-CSF), and IFNγ, whereas serum prolactin affected STAT5 activation in T cells. The responses of STAT1, STAT3, and STAT5 to IFNα were greatly reduced in SLE T cells, B cells, and monocytes, except for the STAT1 response to IFNα in monocytes. The response of STAT3 to IL6 was reduced in SLE T cells.

Conclusions

The basal activation of STATs signaling and reduced response to cytokines may be helpful us to identify the activity and severity of SLE.  相似文献   

16.

Background and Aims

Despite the high prevalence of chronic hepatitis B (CHB) in Africa, few studies have been performed among African patients. We sought to evaluate liver stiffness measurement by FibroScan® (LSM) and two biochemical scores (FibroTest®, Fibrometer®) to diagnose liver fibrosis in Senegalese CHB patients with HBV plasma DNA load ≥3.2 log10 IU/mL and normal alanine aminotransferase (ALT) values.

Methods

LSM and liver fibrosis biochemical markers were performed on 225 consecutive HBV infected Senegalese patients with high viral load. Patients with an LSM range between 7 and 13 kPa underwent liver biopsy (LB). Two experienced liver pathologists performed histological grading using Metavir and Ishak scoring.

Results

225 patients were evaluated (84% male) and LB was performed in 69 patients, showing F2 and F3 fibrosis in 17% and 10% respectively. In these patients with a 7–13 kPa range of LSM, accuracy for diagnosis of significant fibrosis according to LB was unsatisfactory for all non-invasive markers with AUROCs below 0.70. For patients with LSM values below 7 kPa, FibroTest® (FT), and Fibrometer® (FM) using the cut-offs recommended by the test promoters suggested a fibrosis in 18% of cases for FT (8% severe fibrosis) and 8% for FM. For patients with LSM values greater than 13 kPa, FT, FM suggested a possible fibrosis in 73% and 70%, respectively.

Conclusion

In highly replicative HBV-infected African patients with normal ALT and LSM value below 13 kPa, FibroScan®, FibroTest® or Fibrometer® were unsuitable to predict the histological liver status of fibrosis.  相似文献   

17.

Backgrounds and Aim

Current assessment of pre-operative liver function relies upon biochemical blood tests and histology but these only indirectly measure liver function. Mitochondrial function (MF) analysis allows direct measurement of cellular metabolic function and may provide an additional index of hepatic health. Conventional MF analysis requires substantial tissue samples (>100 mg) obtained at open surgery. Here we report a method to assess MF using <3 mg of tissue obtained by a Tru-cut® biopsy needle making it suitable for percutaneous application.

Methods

An 18G Bard® Max-core® biopsy instrument was used to collect samples. The optimal Tru-cut® sample weight, stability in ice-cold University of Wisconsin solution, reproducibility and protocol utility was initially evaluated in Wistar rat livers then confirmed in human samples. MF was measured in saponin-permeabilized samples using high-resolution respirometry.

Results

The average mass of a single rat and human liver Tru-cut® biopsy was 5.60±0.30 and 5.16±0.15 mg, respectively (mean; standard error of mean). Two milligram of sample was found the lowest feasible mass for the MF assay. Tissue MF declined after 1 hour of cold storage. Six replicate measurements within rats and humans (n = 6 each) showed low coefficient of variation (<10%) in measurements of State-III respiration, electron transport chain (ETC) capacity and respiratory control ratio (RCR). Ischemic rat and human liver samples consistently showed lower State-III respiration, ETC capacity and RCR, compared to normal perfused liver samples.

Conclusion

Consistent measurement of liver MF and detection of derangement in a disease state was successfully demonstrated using less than half the tissue from a single Tru-cut® biopsy. Using this technique outpatient assessment of liver MF is now feasible, providing a new assay for the evaluation of hepatic function.  相似文献   

18.

Background

DNA vaccine immunogenicity has been limited by inefficient delivery. Needle-free delivery of DNA using a CO2-powered Biojector® device was compared to delivery by needle and syringe and evaluated for safety and immunogenicity.

Methods

Forty adults, 18–50 years, were randomly assigned to intramuscular (IM) vaccinations with DNA vaccine, VRC-HIVDNA016-00-VP, (weeks 0, 4, 8) by Biojector® 2000™ or needle and syringe (N/S) and boosted IM at week 24 with VRC-HIVADV014-00-VP (rAd5) with N/S at 1010 or 1011 particle units (PU). Equal numbers per assigned schedule had low (≤500) or high (>500) reciprocal titers of preexisting Ad5 neutralizing antibody.

Results

120 DNA and 39 rAd5 injections were given; 36 subjects completed follow-up research sample collections. IFN-γ ELISpot response rates were 17/19 (89%) for Biojector® and 13/17 (76%) for N/S delivery at Week 28 (4 weeks post rAd5 boost). The magnitude of ELISpot response was about 3-fold higher in Biojector® compared to N/S groups. Similar effects on response rates and magnitude were observed for CD8+, but not CD4+ T-cell responses by ICS. Env-specific antibody responses were about 10-fold higher in Biojector-primed subjects.

Conclusions

DNA vaccination by Biojector® was well-tolerated and compared to needle injection, primed for greater IFN-γ ELISpot, CD8+ T-cell, and antibody responses after rAd5 boosting.

Trial Registration

ClinicalTrials.gov NCT00109629  相似文献   

19.

Background

Cytokine response plays a vital role in various human lipopolysaccharide (LPS) infectious and inflammatory diseases. This study aimed to find genetic variants that might affect the levels of LPS-induced interleukin (IL)-6, IL-8, IL-10, IL-1ra and tumor necrosis factor (TNF)-α cytokine production.

Methods

We performed an initial genome-wide association study using Affymetrix Human Mapping 500 K GeneChip® to screen 130 healthy individuals of Danish descent. The levels of IL-6, IL-8, IL-10, IL-1ra and TNF-α in 24-hour LPS-stimulated whole blood samples were compared within different genotypes. The 152 most significant SNPs were replicated using Illumina Golden Gate® GeneChip in an independent cohort of 186 Danish individuals. Next, 9 of the most statistical significant SNPs were replicated using PCR-based genotyping in an independent cohort of 400 Danish individuals. All results were analyzed in a combined study among the 716 Danish individuals.

Results

Only one marker of the 500 K Gene Chip in the discovery study showed a significant association with LPS-induced IL-1ra cytokine levels after Bonferroni correction (P<10−7). However, this SNP was not associated with the IL-1ra cytokine levels in the replication dataset. No SNPs reached genome-wide significance for the five cytokine levels in the combined analysis of all three stages.

Conclusions

The associations between the genetic variants and the LPS-induced IL-6, IL-8, IL-10, IL-1ra and TNF-α cytokine levels were not significant in the meta-analysis. This present study does not support a strong genetic effect of LPS-stimulated cytokine production; however, the potential for type II errors should be considered.  相似文献   

20.

Background

Three-dimensional (3D) in-vitro cultures are recognized for recapitulating the physiological microenvironment and exhibiting high concordance with in-vivo conditions. Taking the advantages of 3D culture, we have developed the in-vitro tumor model for anticancer drug screening.

Methods

Cancer cells grown in 6 and 96 well AlgiMatrix™ scaffolds resulted in the formation of multicellular spheroids in the size range of 100–300 µm. Spheroids were grown in two weeks in cultures without compromising the growth characteristics. Different marketed anticancer drugs were screened by incubating them for 24 h at 7, 9 and 11 days in 3D cultures and cytotoxicity was measured by AlamarBlue® assay. Effectiveness of anticancer drug treatments were measured based on spheroid number and size distribution. Evaluation of apoptotic and anti-apoptotic markers was done by immunohistochemistry and RT-PCR. The 3D results were compared with the conventional 2D monolayer cultures. Cellular uptake studies for drug (Doxorubicin) and nanoparticle (NLC) were done using spheroids.

Results

IC50 values for anticancer drugs were significantly higher in AlgiMatrix™ systems compared to 2D culture models. The cleaved caspase-3 expression was significantly decreased (2.09 and 2.47 folds respectively for 5-Fluorouracil and Camptothecin) in H460 spheroid cultures compared to 2D culture system. The cytotoxicity, spheroid size distribution, immunohistochemistry, RT-PCR and nanoparticle penetration data suggested that in vitro tumor models show higher resistance to anticancer drugs and supporting the fact that 3D culture is a better model for the cytotoxic evaluation of anticancer drugs in vitro.

Conclusion

The results from our studies are useful to develop a high throughput in vitro tumor model to study the effect of various anticancer agents and various molecular pathways affected by the anticancer drugs and formulations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏