首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.

Aims

Accurate liver fibrosis staging is crucial for the management of chronic hepatitis C (CHC). The invasiveness and cost burden of liver biopsy have driven the search for new noninvasive biomarkers of fibrosis. Based on the link between serum angiopoietin-1 and 2 levels and CHC progression, we aimed to determine the value of these angiogenic factors as noninvasive biomarkers of liver fibrosis.

Methods

Serum levels of angiopoietin-1 and -2 were measured by ELISA in 108 CHC patients who underwent pretreatment liver biopsy. The correlation between angiopoietins and clinical and demographic variables with liver fibrosis was analyzed by univariate regression. Significant factors were then subjected to multivariate analysis, from which we constructed a novel noninvasive liver fibrosis index (AngioScore), whose performance was validated in an independent series of 71 CHC patients. The accuracy of this model was compared with other documented fibrosis algorithms by De Long test.

Results

Angiopoietins correlated significantly with hepatic fibrosis; however, only angiopoietin-2 was retained in the final model, which also included age, platelets, AST, INR, and GGT. The model was validated and behaved considerably better than other fibrosis indices in discriminating all, significant, moderate and severe liver fibrosis (0.886, 0.920, 0.923). Using clinically relevant cutoffs, we classified CHC patients by discarding significant fibrosis and diagnosing moderate and severe fibrosis with greater accuracy, sensitivity, and specificity.

Conclusions

Our novel noninvasive liver fibrosis model, based on serum angiopoietin-2 levels, outperforms other indices and should help substantially in managing CHC and monitoring long-term follow-up prognosis.  相似文献   

2.

Background

The pulmonary residence time of inhaled glucocorticoids as well as their rate and extend of absorption into systemic circulation are important facets of their efficacy-safety profile. We evaluated a novel approach to elucidate the pulmonary absorption of an inhaled glucocorticoid. Our objective was to monitor and compare the combined process of drug particle dissolution, pro-drug activation and time course of initial distribution from human lung tissue into plasma for two different glucocorticoid formulations.

Methods

We chose beclomethasone dipropionate (BDP) delivered by two different commercially available HFA-propelled metered dose inhalers (Sanasthmax®/Becloforte™ and Ventolair®/Qvar™). Initially we developed a simple dialysis model to assess the transfer of BDP and its active metabolite from human lung homogenate into human plasma. In a novel experimental setting we then administered the aerosols into the bronchus of an extracorporally ventilated and reperfused human lung lobe and monitored the concentrations of BDP and its metabolites in the reperfusion fluid.

Results

Unexpectedly, we observed differences between the two aerosol formulations Sanasthmax®/Becloforte™ and Ventolair®/Qvar™ in both the dialysis as well as in the human reperfusion model. The HFA-BDP formulated as Ventolair®/Qvar™ displayed a more rapid release from lung tissue compared to Sanasthmax®/Becloforte™. We succeeded to explain and illustrate the observed differences between the two aerosols with their unique particle topology and divergent dissolution behaviour in human bronchial fluid.

Conclusion

We conclude that though the ultrafine particles of Ventolair®/Qvar™ are beneficial for high lung deposition, they also yield a less desired more rapid systemic drug delivery. While the differences between Sanasthmax®/Becloforte™ and Ventolair®/Qvar™ were obvious in both the dialysis and lung perfusion experiments, the latter allowed to record time courses of pro-drug activation and distribution that were more consistent with results of comparable clinical trials. Thus, the extracorporally reperfused and ventilated human lung is a highly valuable physiological model to explore the lung pharmacokinetics of inhaled drugs.  相似文献   

3.

Backgrounds and Aim

Current assessment of pre-operative liver function relies upon biochemical blood tests and histology but these only indirectly measure liver function. Mitochondrial function (MF) analysis allows direct measurement of cellular metabolic function and may provide an additional index of hepatic health. Conventional MF analysis requires substantial tissue samples (>100 mg) obtained at open surgery. Here we report a method to assess MF using <3 mg of tissue obtained by a Tru-cut® biopsy needle making it suitable for percutaneous application.

Methods

An 18G Bard® Max-core® biopsy instrument was used to collect samples. The optimal Tru-cut® sample weight, stability in ice-cold University of Wisconsin solution, reproducibility and protocol utility was initially evaluated in Wistar rat livers then confirmed in human samples. MF was measured in saponin-permeabilized samples using high-resolution respirometry.

Results

The average mass of a single rat and human liver Tru-cut® biopsy was 5.60±0.30 and 5.16±0.15 mg, respectively (mean; standard error of mean). Two milligram of sample was found the lowest feasible mass for the MF assay. Tissue MF declined after 1 hour of cold storage. Six replicate measurements within rats and humans (n = 6 each) showed low coefficient of variation (<10%) in measurements of State-III respiration, electron transport chain (ETC) capacity and respiratory control ratio (RCR). Ischemic rat and human liver samples consistently showed lower State-III respiration, ETC capacity and RCR, compared to normal perfused liver samples.

Conclusion

Consistent measurement of liver MF and detection of derangement in a disease state was successfully demonstrated using less than half the tissue from a single Tru-cut® biopsy. Using this technique outpatient assessment of liver MF is now feasible, providing a new assay for the evaluation of hepatic function.  相似文献   

4.

Background and Aims

Despite the high prevalence of chronic hepatitis B (CHB) in Africa, few studies have been performed among African patients. We sought to evaluate liver stiffness measurement by FibroScan® (LSM) and two biochemical scores (FibroTest®, Fibrometer®) to diagnose liver fibrosis in Senegalese CHB patients with HBV plasma DNA load ≥3.2 log10 IU/mL and normal alanine aminotransferase (ALT) values.

Methods

LSM and liver fibrosis biochemical markers were performed on 225 consecutive HBV infected Senegalese patients with high viral load. Patients with an LSM range between 7 and 13 kPa underwent liver biopsy (LB). Two experienced liver pathologists performed histological grading using Metavir and Ishak scoring.

Results

225 patients were evaluated (84% male) and LB was performed in 69 patients, showing F2 and F3 fibrosis in 17% and 10% respectively. In these patients with a 7–13 kPa range of LSM, accuracy for diagnosis of significant fibrosis according to LB was unsatisfactory for all non-invasive markers with AUROCs below 0.70. For patients with LSM values below 7 kPa, FibroTest® (FT), and Fibrometer® (FM) using the cut-offs recommended by the test promoters suggested a fibrosis in 18% of cases for FT (8% severe fibrosis) and 8% for FM. For patients with LSM values greater than 13 kPa, FT, FM suggested a possible fibrosis in 73% and 70%, respectively.

Conclusion

In highly replicative HBV-infected African patients with normal ALT and LSM value below 13 kPa, FibroScan®, FibroTest® or Fibrometer® were unsuitable to predict the histological liver status of fibrosis.  相似文献   

5.

Background

Video-games have become an integral part of the new multimedia culture. Several studies assessed video-gaming enhancement of spatial attention and eye-hand coordination. Considering the technical difficulty of laparoscopic procedures, legal issues and time limitations, the validation of appropriate training even outside of the operating rooms is ongoing. We investigated the influence of a four-week structured Nintendo® Wii™ training on laparoscopic skills by analyzing performance metrics with a validated simulator (Lap Mentor™, Simbionix™).

Methodology/Principal Findings

We performed a prospective randomized study on 42 post-graduate I–II year residents in General, Vascular and Endoscopic Surgery. All participants were tested on a validated laparoscopic simulator and then randomized to group 1 (Controls, no training with the Nintendo® Wii™), and group 2 (training with the Nintendo® Wii™) with 21 subjects in each group, according to a computer-generated list. After four weeks, all residents underwent a testing session on the laparoscopic simulator of the same tasks as in the first session. All 42 subjects in both groups improved significantly from session 1 to session 2. Compared to controls, the Wii group showed a significant improvement in performance (p<0.05) for 13 of the 16 considered performance metrics.

Conclusions/Significance

The Nintendo® Wii™ might be helpful, inexpensive and entertaining part of the training of young laparoscopists, in addition to a standard surgical education based on simulators and the operating room.  相似文献   

6.

Background

Cytokines and chemokines are relevant biomarkers of pathology and immunity to infectious diseases such as malaria. Several commercially available kits based on quantitative suspension array technologies allow the profiling of multiple cytokines and chemokines in small volumes of sample. However, kits are being continuously improved and information on their performance is lacking.

Methodology/Principal Findings

Different cytokine/chemokine kits, two flow cytometry-based (eBioscience® FlowCytomix™ and BD™ Cytometric Bead Array Human Enhanced Sensitivity) and four Luminex®-based (Invitrogen™ Human Cytokine 25-Plex Panel, Invitrogen™ Human Cytokine Magnetic 30-Plex Panel, Bio-Rad® Bio-Plex Pro™ Human Cytokine Plex Assay and Millipore™ MILLIPLEX® MAP Plex Kit) were compared. Samples tested were supernatants of peripheral blood mononuclear cells of malaria-exposed children stimulated with Plasmodium falciparum parasite lysates. Number of responses in range that could be detected was determined and reproducibility of duplicates was evaluated by the Bland-Altman test. Luminex® kits performed better than flow cytometry kits in number of responses in range and reproducibility. Luminex® kits were more reproducible when magnetic beads were used. However, within each methodology overall performance depended on the analyte tested in each kit. Within the Luminex® kits, the Invitrogen™ with polystyrene beads had the poorer performance, whereas Invitrogen™ with magnetic beads had the higher percentage of cytokines/chemokines with both readings in range (40%), followed by Bio-Rad® with magnetic beads (35%). Regarding reproducibility, the Millipore™ kit had the highest percentage (60%) of cytokines/chemokines with acceptable limits of agreement (<30%), followed by the Invitrogen™ with magnetic beads (40%) that had tighter limits of agreement.

Conclusions/Significance

Currently available kits for cytokine and chemokine quantification differ in reproducibility and concentration range of accurate detection. Luminex®-based kits with magnetic beads perform the best. Data highlights the importance of testing different kits before each study to choose the most appropriate, depending on the priority of the cytokines assessed.  相似文献   

7.

Background

One of the best ways to prevent malaria is the use of insecticide-treated bed nets. Manufacturers pursue easier, safer and more efficient nets. Hence, many studies on the efficacy and wash resistance using World Health Organization standards have been reported. The commonly used detergent is “Savon de Marseille”, because it closely resembles actually used soaps. At the 54th Collaborative International Pesticides Analytical Council (CIPAC) Technical Meeting in 2010, it was suggested to replace it by a standardized “CIPAC washing agent”. The aim of this study was to investigate the difference between a laboratory hand washing simulation using the CIPAC washing agent (method-1) and a domestic washing (method-2) on different bed nets, as well as the effect of the drying process on the release of active ingredient.

Methods

Interceptor®, Permanet®2.0 and Netprotect® nets were used in three treatments, each repeated 20 times. The first treatment included method-1 washing and indoor drying. The second treatment included method-2 washing and indoor drying. The third treatment used method-2 washing and UV-drying. The residual insecticide contents were determined using gas chromatography.

Results

The washing procedure and the number of washes have a significant effect on the release of active ingredient. Statistically, the two washing methods have the same effect on removing the active ingredient from the Interceptor® and Permanet®2.0 net, but a significantly different influence on the Netprotect® nets. The drying process has no significant effect on the insecticide.

Conclusion

Both washing procedures affected the amount of insecticide remaining on nets independently of the impregnation technology. The active ingredient decreases with the number of washing cycles following an exponential or logarithmic model for coated nets. The laboratory hand washing simulation had more impact on the decrease of active ingredient content of the Netprotect® nets. All net types seemed to be effectively protected against UV-light.  相似文献   

8.

Background

Assessing liver fibrosis is traditionally performed by biopsy, an imperfect gold standard. Non-invasive techniques, liver stiffness measurements (LSM) and biomarkers [FibroTest® (FT)], are widely used in countries where they are available. The aim was to identify factors associated with LSM accuracy using FT as a non-invasive endpoint and vice versa.

Methods

The proof of concept was taken using the manufacturers recommendations for excluding patients at high risk of false negative/positive. The hypothesis was that the concordance between LSM and FT, would be improved by excluding high-risk patients. Thereafter, the impact of potential variability factors was assessed by the same methods. Liver biopsy and independent endpoints were used to validate the results.

Results

Applying manufacturers'' recommendations in 2,004 patients increased the strength of concordance between LSM and FT (P<0.00001). Among the 1,338 patients satisfying recommendations, the methodology identified a significant LSM operator effect (P = 0.001) and the following variability factors (all P<0.01), related to LSM: male gender, older age, and NAFLD as a cause of liver disease. Biopsy confirmed in 391 patients these results.

Conclusion

This study has validated the concept of using the strength of concordance between non-invasive estimates of liver fibrosis for the identification of factors associated with variability and precautions of use.  相似文献   

9.

Aim/background

To evaluate how the use of volumetric-modulated arc therapy (VMAT) with RapidArc® can improve treatment delivery efficiency based on the analysis of the beam-on times and monitor units (MU) needed to deliver therapy for multiple clinical applications in a large patient population.

Materials and methods

A total of 898 treatment courses were delivered in 745 patients treated from October 2008 to March 2013 using RapidArc® treatment plans generated in Eclipse™ TPS. All patients were treated with curative or palliative intent using different techniques including conventional fractionation (83%) and radiosurgery or SBRT (17%), depending on the clinical indications. Treatment delivery was evaluated based on measured beam-on time and recorded MU values delivered on a Varian Trilogy™ linear accelerator.

Results

For conventional fractionation treatments using RapidArc®, the delivery times ranged from 38 s to 4 min and 40 s (average 2 min and 6 s). For radiosurgical treatments the delivery times ranged from 1 min and 42 s to 9 min and 22 s (average 4 min and 4 s). The average number of MU per Gy was 301 for the entire group, with 285 for the conventional group and 317 for the radiosurgical group.

Conclusions

In this study with a large heterogeneous population, treatments using RapidArc® were delivered with substantially less beam-on time and fewer MUs than conventional fractionation. This was highly advantageous, increasing flexibility of the scheduling allowing treatment of radiosurgery patients during the regular daily work schedule. Additionally, reduction of leakage radiation dose was achieved.  相似文献   

10.

Background

A combination treatment of interferon and ribavirin is the standard and the commonly used treatment for chronic hepatitis C (CHC). Developing noninvasive tests like serum indicators that can predict treatment outcome at an early stage of therapy is beneficial for individualized treatment and management of CHC. A glyco-indicator based on the glyco-alteration of serum α1-acid glycoprotein, LecT-Hepa, was discovered by glycomics technologies as a robust indicator of liver fibrosis. Here, we investigated the clinical utility of LecT-Hepa for evaluation of treatment outcome.

Results

Firstly, ninety-seven patients with CHC were used for comparison of LecT-Hepa in serum and plasma. We found no significant difference in the concentrations of LecT-Hepa in serum and plasma. And then, 213 serum specimens from 45 patients who received 48 weeks of treatment with interferon and ribavirin were followed up for 96 weeks, and were used for evaluation of the role of LecT-Hepa. We found that LecT-Hepa might reflect the change in fibrosis regression during the treatment process. Moreover, the change of LecT-Hepa at the first 12 weeks of treatment could already predict the antiviral treatment response, which was more superior to FIB-4 index and aspartate aminotransferase-to-platelet ratio index (APRI) in this study.

Conclusions

These results provide a new perspective that serum glycoprotein could be used as a joint diagnosis indicator for estimation treatment outcome of viral hepatitis at earlier stage of therapy.

Electronic supplementary material

The online version of this article (doi:10.1186/1559-0275-11-44) contains supplementary material, which is available to authorized users.  相似文献   

11.

Objective

The aim of our study was to assess a possible association between plasma inflammatory biomarkers (CRP, IL-6, soluble CD14) and the extent of fibrosis or cirrhosis using a FibroScan® in HIV/HCV co-infected patients.

Methods

This cross-sectional study assessed 60 HIV/HCV co-infected patients who had paired plasma samples and FibroScan® values available. All included patients were controlled for HIV infection (HIV-1 RNA <50 copies/mL) and had detectable HCV RNA levels. Levels of three biomarkers were measured in all samples using commercial ELISA kits. Multivariate logistic regression models identified factors associated with the METAVIR stages of fibrosis (F0–F2 vs. F3–F4).

Results

In univariate logistic regression analyses, in addition to sCD14 (odds ratio [OR] = 3.23, 95% confidence interval [95%CI] = 1.30–7.97, P = 0.01), aspartate aminotransferase (AST), alanine aminotransferase, platelet counts, and CD4 cell counts were associated with the stage of liver fibrosis and, thus, were introduced into the model. However, only AST (OR = 1.06, 95%CI = 1.02–1.10, P = 0.0009) was independently associated with F3–F4 stage liver fibrosis.

Conclusions

In our study of HIV/HCV co-infected patients, sCD14 plasma level, a biomarker of monocyte activation, was not independently associated with the F3–F4 stage of liver fibrosis. We hypothesize that the higher levels of inflammation markers observed in HIV/HCV co-infected patients, compared to HCV mono-infected patients, prevent this association being observed within this population.  相似文献   

12.

Background

With the rapid development of real-time elastography (RTE), a variety of measuring methods have been developed for the assessment of hepatic fibrosis. We evaluated the overall performance of four methods based on RTE by performing meta-analysis of published literature.

Methods

Online journal databases and a manual search from April 2000 to April 2014 were used. Studies from different databases that meet inclusion criteria were enrolled. The statistical analysis was performed using a random-effects model and fixed-effects model for the overall effectiveness of RTE. The area under the receiver operating characteristic curve (AUROC) was calculated for various means. Fagan plot analysis was used to estimate the clinical utility of RTE, and the heterogeneity of the studies was explored with meta-regression analysis.

Results

Thirteen studies from published articles were enrolled and analyzed. The combined AUROC of the liver fibrosis index (LFI) for the evaluation of significant fibrosis (F≥2), advanced fibrosis (F≥3), and cirrhosis (F = 4) were 0.79, 0.94, and 0.85, respectively. The AUROC of the elasticity index (EI) ranged from 0.75 to 0.92 for F≥2 and 0.66 to 0.85 for F = 4. The overall AUROC of the elastic ratio of the liver for the intrahepatic venous vessels were 0.94, 0.93, and 0.96, respectively. The AUROC of the elastic ratio of the liver for the intercostal muscle in diagnosing advanced fibrosis and cirrhosis were 0.96 and 0.92, respectively. There was significant heterogeneity in the diagnostic odds ratio (DOR) for F≥2 of LFI mainly due to etiology (p<0.01).

Conclusion

The elastic ratio of the liver for the intrahepatic vein has excellent precision in differentiating each stage of hepatic fibrosis and is recommend to be applied to the clinic.  相似文献   

13.
14.

Background

Tiotropium bromide is an effective therapy for COPD patients. Comparing across programs tiotropium Respimat® Soft Mist™ inhaler was at least as efficacious as tiotropium HandiHaler®, however, concerns have been raised about tiotropium’s safety when given via Respimat®.

Methods

The TIOSPIR® trial (NCT01126437) compares the safety and efficacy of tiotropium Respimat® 5 μg once daily (marketed) and 2.5 μg once daily (investigational) with tiotropium HandiHaler® 18 μ once daily (marketed). The hypotheses to be tested are 1). that tiotropium Respimat® 5 μg once daily and Respimat® 2.5 μg once daily are non-inferior to HandiHaler® in terms of all-cause mortality, and 2). that tiotropium Respimat® 5 μg once daily is superior to HandiHaler® in terms of time to first exacerbation. A spirometry substudy evaluates the bronchodilator efficacy. The trial is a randomized, double-blind, double dummy, event-driven, parallel group study. Participants can use any background treatment for COPD except inhaled anticholinergic agents. The study encompasses a wide range of COPD patients, e.g. patients with stable cardiac diseases including arrhythmia can be included. Clinical sites are international and include both primary care as well as specialists.

Results

To date, over 17,000 participants have been randomized from over 1200 sites in 50 countries with an anticipated treatment duration of 2–3 years.

Conclusion

TIOSPIR® will provide precise estimates of the relative safety and efficacy of the Respimat® and HandiHaler® formulations of tiotropium, assess potential dose-dependence of important outcomes and provide information on the clinical epidemiology of COPD in a large international patient cohort.  相似文献   

15.
WK Seto  DK Wong  J Fung  PP Ip  JC Yuen  IF Hung  CL Lai  MF Yuen 《PloS one》2012,7(8):e43087

Introduction

There is no data on the relationship between hepatitis B surface antigen (HBsAg) levels and liver fibrosis in hepatitis B e antigen (HBeAg)-positive patients with chronic hepatitis B (CHB).

Methods

Serum HBsAg and HBV DNA levels in HBeAg-positive CHB patients with liver biopsies were analyzed. The upper limit of normal (ULN) of alanine aminotransferase (ALT) was 30 and 19 U/L for men and women respectively. Histologic assessment was based on Ishak fibrosis staging for fibrosis and Knodell histologic activity index (HAI) for necroinflammation.

Results

140 patients (65% male, median age 32.7 years) were recruited. 56 (40%) had ALT ≤2×ULN. 72 (51.4%) and 42 (30%) had fibrosis score ≤1 and necroinflammation grading ≤4 respectively. Patients with fibrosis score ≤1, when compared to patients with fibrosis score >1, had significantly higher median HBsAg levels (50,320 and 7,820 IU/mL respectively, p<0.001). Among patients with ALT ≤2×ULN, serum HBsAg levels achieved an area under receiver operating characteristic curve of 0.869 in predicting fibrosis score ≤1. HBsAg levels did not accurately predict necroinflammation score. HBsAg ≥25,000 IU/mL was independently associated with fibrosis score ≤1 (p = 0.025, odds ratio 9.042).Using this cut-off HBsAg level in patients with ALT ≤2×ULN, positive and negative predictive values for predicting fibrosis score ≤1 were 92.7% and 60.0% respectively. HBV DNA levels had no association with liver histology.

Conclusion

Among HBeAg-positive patients with ALT ≤2×ULN, high serum HBsAg levels can accurately predict fibrosis score ≤1, and could potentially influence decisions concerning treatment commencement and reduce the need for liver biopsy.  相似文献   

16.

Background

DNA vaccine immunogenicity has been limited by inefficient delivery. Needle-free delivery of DNA using a CO2-powered Biojector® device was compared to delivery by needle and syringe and evaluated for safety and immunogenicity.

Methods

Forty adults, 18–50 years, were randomly assigned to intramuscular (IM) vaccinations with DNA vaccine, VRC-HIVDNA016-00-VP, (weeks 0, 4, 8) by Biojector® 2000™ or needle and syringe (N/S) and boosted IM at week 24 with VRC-HIVADV014-00-VP (rAd5) with N/S at 1010 or 1011 particle units (PU). Equal numbers per assigned schedule had low (≤500) or high (>500) reciprocal titers of preexisting Ad5 neutralizing antibody.

Results

120 DNA and 39 rAd5 injections were given; 36 subjects completed follow-up research sample collections. IFN-γ ELISpot response rates were 17/19 (89%) for Biojector® and 13/17 (76%) for N/S delivery at Week 28 (4 weeks post rAd5 boost). The magnitude of ELISpot response was about 3-fold higher in Biojector® compared to N/S groups. Similar effects on response rates and magnitude were observed for CD8+, but not CD4+ T-cell responses by ICS. Env-specific antibody responses were about 10-fold higher in Biojector-primed subjects.

Conclusions

DNA vaccination by Biojector® was well-tolerated and compared to needle injection, primed for greater IFN-γ ELISpot, CD8+ T-cell, and antibody responses after rAd5 boosting.

Trial Registration

ClinicalTrials.gov NCT00109629  相似文献   

17.

Background

Older adults with type 2 Diabetes Mellitus are at increased risk of falling. The current study aims to identify risk factors that mediate the relationship between diabetes and falls.

Methods

199 older adults (104 with diabetes and 95 healthy controls) underwent a medical screening. Gait (GAITRite®), balance (AccuGait® force plate), grip strength (Jamar®), and cognitive status (Mini-Mental State Examination and Clock Drawing Test) were assessed. Falls were prospectively recorded during a 12-month follow-up period using monthly calendars.

Results

Compared to controls, diabetes participants scored worse on all physical and cognitive measures. Sixty-four participants (42 diabetes vs. 22 controls) reported at least one injurious fall or two non-injurious falls (“fallers”). Univariate logistic regression identified diabetes as a risk factor for future falls (Odds Ratio 2.25, 95%CI 1.21–4.15, p = 0.010). Stepwise multiple regressions defined diabetes and poor balance as independent risk factors for falling. Taking more medications, slower walking speed, shorter stride length and poor cognitive performance were mediators that reduced the Odds Ratio of the relationship between diabetes and faller status relationship the most followed by reduced grip strength and increased stride length variability.

Conclusions

Diabetes is a major risk factor for falling, even after controlling for poor balance. Taking more medications, poorer walking performance and reduced cognitive functioning were mediators of the relationship between diabetes and falls. Tailored preventive programs including systematic medication reviews, specific balance exercises and cognitive training might be beneficial in reducing fall risk in older adults suffering from diabetes.  相似文献   

18.
19.

Background

High incidence of septic patients increases the pressure of faster and more reliable bacterial identification methods to adapt patient management towards focused and effective treatment options. The aim of this study was to assess two automated DNA extraction solutions with the PCR and microarray-based assay to enable rapid and reliable detection and speciation of causative agents in the diagnosis of sepsis.

Methodology/Principal Findings

We evaluated two automated DNA instruments NucliSENS® easyMAG® and NorDiag Arrow for the preparation of blood culture samples. A set of 91 samples flagged as positive during incubation was analyzed prospectively with the high-throughput generation of Prove-it™ Sepsis assay designed to identify over 60 Gram-negative and Gram-positive bacterial species as well as methicillin resistance marker from a blood culture. Bacterial findings were accurately reported from 77 blood culture samples, whereas 14 samples were reported as negative, containing bacteria not belonging to the pathogen panel of the assay. No difference was observed between the performance of NorDiag Arrow or NucliSENS® easyMAG® with regard to the result reporting of Prove-it™ Sepsis. In addition, we also assessed the quality and quantity of DNA extracted from the clinical Escherichia coli isolate with DNA extraction instruments. We observed only minor differences between the two instruments.

Conclusions

Use of automated and standardized sample preparation methods together with rapid, multiplex pathogen detection offers a strategy to speed up reliably the diagnostics of septic patients. Both tested DNA extraction devices were shown to be feasible for blood culture samples and the Prove-it™ Sepsis assay, providing an accurate identification of pathogen within 4,5 hours when the detected pathogen was in the repertoire of the test.  相似文献   

20.

Background

Transient elastography (TE), a non-invasive tool that measures liver stiffness, has been evaluated in meta-analyses for effectiveness in assessing liver fibrosis in European populations with chronic hepatitis C (CHC). However, these data cannot be extrapolated to populations in Asian countries, where chronic hepatitis B (CHB) is more prevalent. In this study, we performed a meta-analysis to assess the overall performance of TE for assessing liver fibrosis in patients with CHB.

Methods

Studies from the literature and international conference abstracts which enrolled only patients with CHB or performed a subgroup analysis of such patients were enrolled. Combined effects were calculated using area under the receiver operating characteristic curves (AUROC) and diagnostic accuracy values of each study.

Result

A total of 18 studies comprising 2,772 patients were analyzed. The mean AUROCs for the diagnosis of significant fibrosis (F2), severe fibrosis (F3), and cirrhosis (F4) were 0.859 (95% confidence interval [CI], 0.857–0.860), 0.887 (95% CI, 0.886–0.887), and 0.929 (95% CI, 0.928–0.929), respectively. The estimated cutoff for F2 was 7.9 (range, 6.1–11.8) kPa, with a sensitivity of 74.3% and specificity of 78.3%. For F3, the cutoff value was determined to be 8.8 (range, 8.1–9.7) kPa, with a sensitivity of 74.0% and specificity of 63.8%. The cutoff value for F4 was 11.7 (range, 7.3–17.5) kPa, with a sensitivity of 84.6% and specificity of 81.5%.

Conclusion

TE can be performed with good diagnostic accuracy for quantifying liver fibrosis in patients with CHB.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号