首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
PurposeIn image-guided particle radiotherapy of abdominal lesions, respiratory motion hinders treatment accuracy. In this study, 2D cineMRI data were used to quantify the tumor (GTV) motion and to evaluate the clinical approach based on deriving an internal target volume (ITV) from a planning 4DCT for gating treatments.MethodsSeven patients with abdominal lesions were treated with carbon-ion therapy at the National Centre of Oncological Hadron-therapy (Italy). The MR scan was performed on the same day of the 4DCT acquisition. For four patients, an additional MR was acquired approximately after 1 week. The cineMRI combined with deformable image registration algorithm was used to quantify tumor motion. Afterwards, two ITVs were defined considering (1) all phases (ITVFB) and (2) only phases within the gating window (ITVG), and then compared with the clinical (4DCT-derived) ITVs (ITVCG and ITVCFB).ResultsTumor residual motion estimated by cineMRI data in the two MRI sessions resulted not significantly different from 4DCT, although cineMRI accounted for cycle-to-cycle variations. The ITV normalized for the GTV median values were higher for ITVFB with respect to ITVG, ITVCFB and ITVCG. The Hausdorff distances with respect to the GTV were up to 10.55 mm, 3.13 mm, 5.56 mm and 2.51 mm, for ITVFB, ITVG, ITVCFB and ITVCG, respectively. According to both metrics, ITVCG and ITVG were not found significantly different.ConclusionsCineMRI acquisitions allowed to quantify organ motion without delivering additional dose to the patient and to verify treatment margins in gated carbon-ion therapy of abdominal lesions.  相似文献   

2.
AimTo evaluate the target dose coverage for lung stereotactic body radiotherapy (SBRT) using helical tomotherapy (HT) with the internal tumor volume (ITV) margin settings adjusted according to the degree of tumor motion.BackgroundLung SBRT with HT may cause a dosimetric error when the target motion is large.Materials and methodsTwo lung SBRT plans were created using a tomotherapy planning station. Using these original plans, five plans with different ITV margins (4.0–20.0 mm for superior-inferior [SI] dimension) were generated. To evaluate the effects of respiratory motion on HT, an original dynamic motion phantom was developed. The respiratory wave of a healthy volunteer was used for dynamic motion as the typical tumor respiratory motion. Five patterns of motion amplitude that corresponded to five ITV margin sizes and three breathing cycles of 7, 14, and 28 breaths per minute were used. We evaluated the target dose change between a static delivery and a dynamic delivery with each motion pattern.ResultsThe target dose difference increased as the tumor size decreased and as the tumor motion increased. Although a target dose difference of <5 % was observed at ≤10 mm of tumor motion for each condition, a maximum difference of -9.94 % ± 7.10 % was observed in cases of small tumors with 20 mm of tumor motion under slow respiration.ConclusionsMinimizing respiratory movement is recommended as much as possible for lung SBRT with HT, especially for cases involving small tumors.  相似文献   

3.
PurposeTo assess the interplay effect amplitude between different planned MU distributions and respiratory patterns in the CyberKnife system when treating moving targets with static tracking technique.MethodsSmall- and Large-Respiratory Motions (SRM and LRM) differing in amplitude and frequency were simulated in a semi-anthropomorphic dynamic thorax phantom. The interplay effect was evaluated for both respiration motions in terms of GTV coverage and conformity for three plans designed with an increasing range of MU per beam (small, medium and large). Each plan was delivered three times changing the initial beam-on phase to assess the inter-fraction variation. Dose distributions were measured using radiochromic films placed in the GTV axial and sagittal planes.ResultsGenerally, SRM plans gave higher GTV coverage and were less dependent on beam-on phases than LRM plans. For SRM (LRM) plans, the GTV coverage ranged from 95.2% to 99.7% (85.9% to 99.8%). Maximum GTV coverage was found for large MU plans in SRM and for small MU plans in LRM. Minimum GTV coverage was found for medium MU plans for both SRM and LRM. For SRM plans, dose conformity decreased with increasing MU range while the variation was reduced for LRM plans. Large MU plans reduced the inter-fraction variation for SRM and LRM.ConclusionsWe confirmed the interplay effect between target motion and beam irradiation time for CyberKnife static tracking. Plans with large MU per beam improved the GTV coverage for small motion amplitude and the inter-fraction dose variation for large motion amplitude.  相似文献   

4.
ObjectiveTo assess the feasibility of treatment planning for pancreatic tumours subject to respiratory motion using field-specific target volumes (FTV) and field-specific organs at risk (FOAR) using four-dimensional computed tomography (4DCT).MethodsFourteen pancreatic cancer patients underwent 4DCT. Radiation oncologists contoured the gross tumour volume (GTV), clinical target volume (CTV), spinal cord, duodenum, kidneys, and stomach. The gating duty cycle was set to 30 % around exhalation. FTV and FOAR were calculated using the 4DCT dataset. Planning target volumes (PTV) and planning organs at risk volumes (PRV) were defined as equal to FTV and FOAR, respectively. A dose of 55.2 Gy relative biological effectiveness (RBE) was planned to target the PTV from four beam angles. A single field uniform dose (SFUD) plan was selected. The dose distribution, including intrafractional motion changes, was generated.ResultsThe mean volume of target receiving 95 % of the planned doses was 96.4 ± 4.1 % to the GTV and 94.7 ± 0.9 % to the CTV. The highest dose to 2 cc of duodenal volume was 27.5 Gy (RBE). The volume of the stomach receiving ⩾30 Gy (RBE) was <7.0 cc in all patients. All metrics for OARs satisfied dose constraints.ConclusionDose to the CTV was covered sufficiently by the 4DCT-generated FTV, and dose to OARs was reduced by 4DCT-generated FOAR. This methodology may prevent adverse reactions while preserving local tumour control.  相似文献   

5.
PurposeTo evaluate the planning feasibility of dose-escalated total marrow irradiation (TMI) with simultaneous integrated boost (SIB) to the active bone marrow (ABM) using volumetric modulated arc therapy (VMAT), and to assess the impact of using planning organs at risk (OAR) volumes (PRV) accounting for breathing motion in the optimization.MethodsFive patients underwent whole-body CT and thoraco-abdominal 4DCT. A planning target volume (PTV) including all bones and ABM was contoured on each whole-body CT. PRV of selected OAR (liver, heart, kidneys, lungs, spleen, stomach) were determined with 4DCT. Planning consisted of 9–10 full 6 MV photon VMAT arcs. Four plans were created for each patient with 12 Gy prescribed to the PTV, with or without an additional 4 Gy SIB to the ABM. Planning dose constraints were set on the OAR or on the PRV. Planning objective was a PTV Dmean < 110% of the prescribed dose, a PTV V110% < 50%, and OAR Dmean ≤ 50–60%.ResultsPTV Dmean < 110% was accomplished for most plans (n = 18/20), while all achieved V110%<50%. SIB plans succeeded to optimally cover the boost volume (median ABM Dmean = 16.3 Gy) and resulted in similar OAR sparing compared to plans without SIB (median OAR Dmean = 40–54% of the ABM prescribed dose). No statistically significant differences between plans optimized with constraints on OAR or PRV were found.ConclusionsAdding a 4 Gy SIB to the ABM for TMI is feasible with VMAT technique, and results in OAR sparing similar to plans without SIB. Setting dose constraints on PRV does not impair PTV dosimetric parameters.  相似文献   

6.
PurposeTo determine the usefulness of abdominal compression in lung stereotactic body radiation therapy (SBRT) depending on lobe tumor location.Materials and methodsTwenty-seven non-small cell lung cancer patients were immobilized in the Stereotactic Body Frame? (Elekta). Eighteen tumors were located in an upper lobe, one in the middle lobe and nine in a lower lobe (one patient had two lesions). All patients underwent two four-dimensional computed tomography (4DCT) scans, with and without abdominal compression. Three-dimensional tumor motion amplitude was determined using manual landmark annotation. We also determined the internal target volume (ITV) and the influence of abdominal compression on lung dose-volume histograms.ResultsThe mean reduction of tumor motion amplitude was 3.5 mm (p = 0.009) for lower lobe tumors and 0.8 mm (p = 0.026) for upper/middle lobe locations. Compression increased tumor motion in 5 cases. Mean ITV reduction was 3.6 cm3 (p = 0.039) for lower lobe and 0.2 cm3 (p = 0.048) for upper/middle lobe lesions. Dosimetric gain of the compression for lung sparing was not clinically relevant.ConclusionsThe most significant impact of abdominal compression was obtained in patients with lower lobe tumors. However, minor or negative effects of compression were reported for other patients and lung sparing was not substantially improved. At our institute, patients with upper or middle lobe lesions are now systematically treated without compression and the usefulness of compression for lower lobe tumors is evaluated on an individual basis.  相似文献   

7.
BackgroundThe advances in image guidance and capability of highly conformal dose deliveries made possible the use of helical tomotherapy (HT) for lung cancer treatment. To determine the effect of respiratory motion on the delivered dose in HT, film dosimetry using a dynamic phantom was performed. This was a phantom study to determine the effect of motion on the delivered dose in HT.Materials and methods4D computed tomography (4DCT) was acquired for various target motions of CIRS dynamic phantom (CIRS Inc., Norfolk, USA) with 2.5cm diameter spherical target of volume 8.2 cc moving in the COS4 motion pattern. AveIP images and treatment plans were generated in the HT planning system. Target excursions during treatment delivery were changed in the superior-inferior, anteroposterior and lateral directions. The breathing cycle time was varied from 4 to 5 sec. and also the delivery interruptions were introduced. A film was exposed for each delivery and gamma analysis was performed.ResultsThe gamma pass rate (GPR) with 3%, 2 mm criteria for the target motion in the S-I direction showed a significant reduction from 97.5% to 54.4% as the motion increased from 3 mm to 8 mm (p = 0.03). For the target motion in S-I = 8 mm, L-R = A-P = 3 mm, the percentage decrease in the GPR was 74% (p = 0.001) for three interruptions.ConclusionThe ITV based approach in HT is ideal for a shallow breathing situation when the tumor excursions were confined to 5 mm in the S-I and 3 mm in L-R and A-P directions.  相似文献   

8.
PurposeThe aim was to identify vascular calcification in 4DCT scan of lung cancer patients and establish the association between overall survival (OS) and vascular calcification, as surrogate for vascular health.MethodsVascular calcification within the thoracic cavity were segmented in 334 lung cancer patients treated with stereotactic body radiation therapy (SBRT). This has been done automatically on 4D planning CT and average reconstruction scans. Correlation between cardiac comorbidity and calcification volumes was evaluated for patients with recorded Adult Co-Morbidity Evaluation (n = 303). Associations between the identified calcifications and OS were further investigated.ResultsThe volume of calcification from the average scan was significantly lower than from each phase (p < 0.001). The highest level of correlations between cardiac comorbidity and volume of the calcifications were found for one phase representing inhale and two phases representing exhale with the least motion blurring due to respiration (p < 0.005). The volume of the calcifications was subsequently averaged over these three phases. The average of calcification volumes over the three phases (denoted by inhale-exhale) showed the highest likelihood in univariate analysis and was chosen as vascular calcification measure. Cox-model suggested that tumor volume (Hazard Ratio [HR] = 1.46, p < 0.01) and inhale-exhale volume (HR = 1.05, p < 0.05) are independent factors predicting OS after adjusting for age, sex, and performance status.ConclusionIt was feasible to use. It 4DCT scan for identifying thoracic calcifications in lung cancer patients treated with SBRT. Calcification volumes from inhale-exhale phases had the highest correlation with overall cardiac comorbidity and the average of the calcification volume obtained from these phases was an independent predictive factor for OS.  相似文献   

9.
PurposeTo evaluate the respiratory motion of adrenal gland metastases in three-dimensional directions using four-dimensional computed tomography (4DCT) images.MethodsFrom January 2013 to May 2016, 12 patients with adrenal gland metastases were included in this study. They all underwent 4DCT scans to assess respiratory motion of adrenal gland metastases in free breathing state. The 4DCT images were sorted into 10 image series according to the respiratory phase from the end inspiration to the end expiration, and then transferred to FocalSim workstation. All gross tumor volumes (GTVs) of adrenal gland metastases were drawn by a single physician and confirmed by a second. Relative coordinates of adrenal gland metastases were automatically generated to calculate adrenal gland metastases motion in different axial directions.ResultsThe average respiratory motion of adrenal gland metastases in left-right (LR), cranial-caudal (CC), anterior-posterior (AP), 3-dimensional (3D) vector directions was 3.4 ± 2.2 mm, 9.5 ± 5.5 mm, 3.8 ± 2.0 mm and 11.3 ± 5.3 mm, respectively. The ratios were 58.6% ± 11.4% and 63.2% ± 12.5% when the volumes of GTVIn0% and GTV In100% were compared with volume of IGTV10phase. The volume ratio of IGTV10phase to GTV3D was 1.73 ± 0.48.ConclusionsAdrenal gland metastasis is a respiration-induced moving target, and an internal target volume boundary should be provided when designing the treatment plan. The CC motion of adrenal gland metastasis is predominant and >5 mm, thus motion management strategies are recommended for patients undergoing external radiotherapy for adrenal gland metastasis.  相似文献   

10.
IntroductionWe evaluated the impact of 4DCT artifacts on carbon-ion pencil beam scanning dose distributions in lung and liver treatment.Methods & materials4DCT was performed in 20 liver and lung patients using area-detector CT (original 4DCT). 4DCT acquisition by multi-detector row CT was simulated using original 4DCT by selecting other phases randomly (plus/minus 20% phases). Since tumor position can move over the respiratory range in original 4DCT, mid-exhalation was set as reference phase. Total prescribed dose of 60 Gy (RBE) was delivered to the clinical target volume (CTV). Reference dose distribution was calculated with the original CT, and actual dose distributions were calculated with treatment planning parameters optimized using the simulated CT (simulated dose). Dose distribution was calculated by substituting these parameters into the original CT.ResultsFor liver cases, CTV-D95 and CTV-Dmin values for the reference dose were 97.6 ± 0.5% and 89.8 ± 0.6% of prescribed dose, respectively. Values for the simulated dose were significantly degraded, to 88.6 ± 14.0% and 46.3 ± 26.7%, respectively. Dose assessment results for lung cases were 84.8 ± 12.8% and 58.0 ± 24.5% for the simulated dose, showing significant degradation over the reference dose of 95.1 ± 1.5% and 87.0 ± 2.2%, respectively.Conclusions4DCT image quality should be closely checked to minimize degradation of dose conformation due to 4DCT artifacts. Medical staff should pay particular attention to checking the quality of 4DCT images as a function of respiratory phase, because it is difficult to recognize 4DCT artifact on a single phase in some cases  相似文献   

11.
Purpose/objectiveStereotactic ablative body radiotherapy (SABR) in multi-centre trials requires rigorous quality assurance to ensure safe and consistent treatment for all trial participants. We report results of vertebral SABR dosimetry credentialing for the ALTG/TROG NIVORAD trial.Material/methodsCentres with a previous SABR site visit performed axial film measurement of the benchmarking vertebral plan in a local phantom and submitted radiochromic film images for analysis. Remaining centres had on-site review of SABR processes and axial film measurement of the vertebral benchmarking plan. Films were analysed for dosimetric and positional accuracy: gamma analysis (>90% passing 2%/2mm/10% threshold) and ≤ 1 mm positional accuracy at target-cord interface was required.Results19 centres were credentialed; 11 had on-site measurement. Delivery devices included linear accelerator, TomoTherapy and CyberKnife systems. Five centres did not achieve 90% gamma passing rate. Of these, three were out of tolerance (OOT) in low (<5Gy) dose regions and > 80% passing rate and deemed acceptable. Two were OOT over the full dose range: one elected not to remeasure; the other also had positional discrepancy greater than 1 mm and repeat measurement with a new plan was in tolerance. The original OOT was attributed to inappropriate MLC constraints. All centres delivered planned target-cord dose gradient within 1 mm.ConclusionCredentialing measurements for vertebral SABR in a multi-centre trial showed although the majority of centres delivered accurate vertebral SABR, there is high value in independent audit measurements. One centre with inappropriate MLC settings was detected, which may have resulted in delivery of clinically unacceptable vertebral SABR plans.  相似文献   

12.
AimDeveloping and assessing the feasibility of using a three-dimensional (3D) printed patient-specific anthropomorphic pelvis phantom for dose calculation and verification for stereotactic ablative radiation therapy (SABR) with dose escalation to the dominant intraprostatic lesions.Material and methodsA 3D-printed pelvis phantom, including bone-mimicking material, was fabricated based on the computed tomography (CT) images of a prostate cancer patient. To compare the extent to which patient and phantom body and bones overlapped, the similarity Dice coefficient was calculated. Modular cylindrical inserts were created to encapsulate radiochromic films and ionization chamber for absolute dosimetry measurements at the location of prostate and at the boost region. Gamma analysis evaluation with 2%/2mm criteria was performed to compare treatment planning system calculations and measured dose when delivering a 10 flattening filter free (FFF) SABR plan and a 10FFF boost SABR plan.ResultsDice coefficients of 0.98 and 0.91 were measured for body and bones, respectively, demonstrating agreement between patient and phantom outlines. For the boost plans the gamma analysis yielded 97.0% of pixels passing 2%/2mm criteria and these results were supported by the chamber average dose difference of 0.47 ± 0.03%. These results were further improved when overriding the bone relative electron density: 97.3% for the 2%/2mm gamma analysis, and 0.05 ± 0.03% for the ionization chamber average dose difference.ConclusionsThe modular patient-specific 3D-printed pelvis phantom has proven to be a highly attractive and versatile tool to validate prostate SABR boost plans using multiple detectors.  相似文献   

13.
14.
PurposeTo use Discrete Cosine Transform to include tumor motion variations on ITV definition of SBRT patients.MethodsData from 66 patients was collected. 2D planar fluoroscopy images (FI) were available for 54 patients. Daily CBCT projections (CBCTp) from 29 patients were employed to measure interfraction amplitude variability. Systematic amplitude variations were obtained from 17 patients with data from both FI and CBCTp.Tumor motion curves obtained from FI were characterized with a Cosine model (CM), based on cosine functions to the power of 2, 4 or 6, and DCT. Performance of both models was evaluated by means of R2 coefficient and by comparing their results on Internal Target Volume (ITV) margins against those calculated from original tumor motion curves.Amplitude variations from CBCTp, as well as estimations of baseline shift variations were added to the DCT model to account for their effect on ITV margins.ResultsDCT replicated tumor motion curves with a mean R2 values for all patients of 0.86, 0.91 and 0.96 for the lateral (LAT), anterior-posterior (AP) and cranio-caudal (CC) directions respectively. CM yielded worst results, with R2 values of 0.64, 0.61 and 0.74 in the three directions.Interfraction amplitude variation increased ITV margins by a 9%, while baseline shift variability implied a 40% and 80–100% increase for normalized values of baseline shift of 0.2 and 0.4 respectively.ConclusionsProbability distribution functions of tumor positions can be successfully characterized with DCT. This permits to include tumor motion variablilities obtained from patient population into patient specific ITVs.  相似文献   

15.
Background and purposeTomotherapy treatment planning depends on parameters that are not used conventionally such as: field width (FW), pitch factor (PF) and modulation factor (MF). The aim of this study is to analyze the relationship between these parameters and their influence on the quality of treatment plans and beam-on time.Material and methodsTen prostate cancer patients were included in the study. For each patient, two cases of irradiation were considered depending on the target volume: PTV1 included the prostate gland, seminal vesicles, pelvic lymph nodes and a 1 cm margin, whereas PTV2 included only the prostate gland with a 1 cm margin. For each patient and each case of irradiation (PTV1 and PTV2) 8 treatment plans were created – all consisted of a different combination of planning parameters (FW = 1.05, 2.5, 5 cm; PF = 0.107, 0.215, 0.43; MF = 1.5, 2.5, 3.5). Default values used in this study were FW = 2.5 cm, PF = 0.215 and MF = 2.5. Hence, for plans with different FWs, parameters of PF and MF were 0.215 and 2.5, respectively; for different PFs, FW and MF were 2.5 and 2.5, respectively; finally for different MFs, FW and PF were 2.5 and 0.215, respectively. The reference plan was optimized for FW = 1.05 cm, PF = 0.107 and MF = 3.5, which was assumed to result in the best dose distribution and the longest treatment time. As a result, 160 plans were created. Each plan was analyzed for dose distribution and execution time.Results and conclusion: Treatment plans with FW of 5 cm resulted in the shortest execution time compromising the dose distribution. Moreover, the dose fall off in the longitudinal direction was not sharp. FW of 1.05 cm and PF of 0.107 were not recommended for routine prostate plans due to long execution time, which was 3 times longer than for plans with FW = 5 cm. There was no substantial decrease of irradiation time when PF was increased from 0.215 to 0.43 for both cases (PTV1 and PTV2); however, the dose distribution was slightly compromised. Finally, decreasing MF from 2.5 to 1.5 was useless because it did not change the beam-on time; however, it did remarkably decrease the dose distribution. Nevertheless, increasing MF up to 3.5 could be considered. The lowest EUD for the rectum and intestines, could be observed for PF = 0.107. For the other plans the differences were rather small (the EUD was almost the same). By reducing PF from 0.43 to 0.107 or FW from 5 to 1.05 the EUD for bladder (in PTV1 case) decreased by 3.13% and 2.60%. When PTV2 was a target volume, the EUD for bladder decreased by 4.54% and 3.43% when FW was changed from 5 to 1.05 and MF from 1.5 to 3.5, respectively. For optimal balance between beam-on time and dose distribution in OARs for routine patients, the authors would suggest to use: FW = 2.5, PF = 0.215 and MF = 2.5.  相似文献   

16.
IntroductionOur markerless tumor tracking algorithm requires 4DCT data to train models. 4DCT cannot be used for markerless tracking for respiratory-gated treatment due to inaccuracies and a high radiation dose. We developed a deep neural network (DNN) to generate 4DCT from 3DCT data.MethodsWe used 2420 thoracic 4DCT datasets from 436 patients to train a DNN, designed to export 9 deformation vector fields (each field representing one-ninth of the respiratory cycle) from each CT dataset based on a 3D convolutional autoencoder with shortcut connections using deformable image registration. Then 3DCT data at exhale were transformed using the predicted deformation vector fields to obtain simulated 4DCT data. We compared markerless tracking accuracy between original and simulated 4DCT datasets for 20 patients. Our tracking algorithm used a machine learning approach with patient-specific model parameters. For the training stage, a pair of digitally reconstructed radiography images was generated using 4DCT for each patient. For the prediction stage, the tracking algorithm calculated tumor position using incoming fluoroscopic image data.ResultsDiaphragmatic displacement averaged over 40 cases for the original 4DCT were slightly higher (<1.3 mm) than those for the simulated 4DCT. Tracking positional errors (95th percentile of the absolute value of displacement, “simulated 4DCT” minus “original 4DCT”) averaged over the 20 cases were 0.56 mm, 0.65 mm, and 0.96 mm in the X, Y and Z directions, respectively.ConclusionsWe developed a DNN to generate simulated 4DCT data that are useful for markerless tumor tracking when original 4DCT is not available. Using this DNN would accelerate markerless tumor tracking and increase treatment accuracy in thoracoabdominal treatment.  相似文献   

17.
Chi A  Liao Z  Nguyen NP  Xu J  Welsh JS  Jang SY  Howe C  Komaki R 《PloS one》2012,7(4):e35809

Background

No selection criteria for helical tomotherapy (HT) based stereotactic ablative radiotherapy (SABR) to treat early stage non-small cell lung cancer (NSCLC) or solitary lung metastases has been established. In this study, we investigate the dosimetric selection criteria for HT based SABR delivering 70 Gy in 10 fractions to avoid severe toxicity in the treatment of centrally located lesions when adequate target dose coverage is desired.

Materials and Methods

78 HT-SABR plans for solitary lung lesions were created to prescribe 70 Gy in 10 fractions to the planning target volume (PTV). The PTV was set to have ≥95% PTV receiving 70 Gy in each case. The cases for which dose constraints for ≥1 OAR could not be met without compromising the target dose coverage were compared with cases for which all target and OAR dose constraints were met.

Results

There were 23 central lesions for which OAR dose constraints could not be met without compromising PTV dose coverage. Comparing to cases for which optimal HT-based SABR plans were generated, they were associated with larger tumor size (5.72±1.96 cm vs. 3.74±1.49 cm, p<0.0001), higher lung dose, increased number of immediately adjacent OARs ( 3.45±1.34 vs. 1.66±0.81, p<0.0001), and shorter distance to the closest OARs (GTV: 0.26±0.22 cm vs. 0.88±0.54 cm, p<0.0001; PTV 0.19±0.18 cm vs. 0.48±0.36 cm, p = 0.0001).

Conclusion

Delivery of 70 Gy in 10 fractions with HT to meet all the given OAR and PTV dose constraints are most likely when the following parameters are met: lung lesions ≤3.78 cm (11.98 cc), ≤2 immediately adjacent OARs which are ≥0.45 cm from the gross lesion and ≥0.21 cm from the PTV.  相似文献   

18.
AimTo compare the dose to organs at risk with free breathing (FB) or voluntary breath-hold (VBH) during radiotherapy of patients with left sided breast cancer.BackgroundRadiotherapy reduces the risk of breast-cancer-specific mortality but the effects on other organs increase non-cancer-specific mortality. Radiation exposure to the heart, in particular in patients with left sided breast cancer, can be reduced by breath hold methods that increase the distance between the heart and the radiation field.Materials and MethodsThree-dimensional conformal radiotherapy (3D-CRT) dose plans for the left breast and organs at risk including the heart, left anterior descending coronary artery (LAD) and ipsilateral lung were compared with FB and VBH in ten patients with left sided breast cancer.ResultsThe mean doses to the heart and LAD were reduced by 50.4 % (p < 0.001) and 58.8 % (p = 0.006), respectively, in VBH relative to FB. The mean dose to the ipsilateral lung was reduced by 13.8 % (p = 0.11) in VBH relative to FB. The planning target volume (PTV) coverage was at least 95 % in both FB and VBH (p = 0.78).ConclusionThe VBH technique significantly reduces the dose to organs at risk in 3D-CRT treatment plans of left sided breast cancer.  相似文献   

19.
PurposeTo implement a knowledge-based (KB) optimization strategy to our adaptive (ART) early-regression guided boosting technique in neo-adjuvant radio-chemotherapy for rectal cancer.Material and methodsThe protocol consists of a first phase delivering 27.6 Gy to tumor/lymph-nodes (2.3 Gy/fr-PTV1), followed by the ART phase concomitantly delivering 18.6 Gy (3.1 Gy/fr) and 13.8 Gy (2.3 Gy/fr) to the residual tumor (PTVART) and to PTV1 respectively. PTVART is obtained by expanding the residual GTV, as visible on MRI at fraction 9. Forty plans were used to generate a KB-model for the first phase using the RapidPlan tool. Instead of building a new model, a robust strategy scaling the KB-model to the ART phase was applied. Both internal and external validation were performed for both phases: all automatic plans (RP) were compared in terms of OARs/PTVs parameters against the original plans (RA).ResultsThe resulting automatic plans were generally better than or equivalent to clinical plans. Of note, V30Gy and V40Gy were significantly improved in RP plans for bladder and bowel; gEUD analysis showed improvement for KB-modality for all OARs, up to 3 Gy for the bowel.ConclusionsThe KB-model generated for the first phase was robust and it was also efficiently adapted to the ART phase. The performance of automatically generated plans were slightly better than the corresponding manual plans for both phases.  相似文献   

20.
BackgroundA purpose of the study was to investigate the dosimetric impact of contrast media on dose calculation using average 4D contrast-enhanced computed tomography (4D-CECT) and delayed 4D-CT (d4D-CT) images caused by CT simulation contrast agents for stereotactic body radiation therapy (SBRT) of liver cases.Materials and methodsFifteen patients of liver SBRT treated using the volumetric modulated arc therapy (VMAT) technique were selected retrospectively. 4D-CECT, and d4D-CT were acquired with the Anzai gating system and GE CT. For all patients, gross target volume (GTV) was contoured on the ten phases after rigid registration of both the contrast and delayed scans and merged to generate internal target volume (ITV) on average CT images. Region of interest (ROI) was drawn on contrast images and then copied to the delayed images after rigid registration of two average CT datasets. The treatment plans were generated for contrast enhanced average CT, delayed average CT and contrast enhanced average CT with electron density of the heart overridden.ResultsNo significant dosimetric difference was observed in plans parameters (mean HU value of the liver, total monitor units, total control points, degree of modulation and average segment area) except mean HU value of the aorta amongst the three arms. All the OARs were evaluated and resulted in statistically insignificant variation (p > 0.05) using one way ANOVA analysis.ConclusionsContrast enhanced 4D-CT is advantageous in accurate delineation of tumors and assessing accurate ITV. The treatment plans generated on average 4D-CECT and average d4D-CT have a clinically insignificant effect on dosimetric parameters.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号