首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 750 毫秒
1.
Analysis of catecholamines (epinephrine, norepinephrine and dopamine) in plasma and urine is used for diagnosis and treatment of catecholamine-producing tumors. Current analytical techniques for catecholamine quantification are laborious, time-consuming and technically demanding. Our aim was to develop an automated on-line solid phase extraction method coupled to high performance liquid chromatography–tandem mass spectrometry (XLC–MS/MS) for the quantification of free catecholamines in urine. Five microlitre urine equivalent was pre-purified by automated on-line solid phase extraction, using phenylboronic acid complexation. Reversed phase (pentafluorophenylpropyl column) chromatography was applied. Mass spectrometric detection was operated in multiple reaction monitoring mode using a quadrupole tandem mass spectrometer with positive electrospray ionization. Urinary reference intervals were set in 24-h urine collections of 120 healthy subjects. XLC–MS/MS was compared with liquid chromatography with electrochemical detection (HPLC–ECD). Total run-time was 14 min. Intra- and inter-assay analytical variations were <10%. Linearity was excellent (R2 > 0.99). Quantification limits were 1.47 nmol/L, 15.8 nmol/L and 11.7 nmol/L for epinephrine, norepinephrine and dopamine, respectively. XLC–MS/MS correlated well with HPLC–ECD (correlation coefficient >0.98). Reference intervals were 1–10 μmol/mol, 10–50 μmol/mol and 60–225 μmol/mol creatinine for epinephrine, norepinephrine and dopamine, respectively. Advantages of the XLC–MS/MS catecholamine method include its high analytical performance by selective PBA affinity and high specificity and sensitivity by unique MS/MS fragmentation.  相似文献   

2.
This paper presents the development of a simple liquid chromatography–tandem mass spectrometry (LC–MS/MS) method to determine corticosteroids in bovine urine sample matrices. This method uses a single phase extraction (SPE) for cleaning of the sample with an Oasis MAX cartridge at pH 9.0–9.5 and elution by a neutral organic solvent (acetonitrile/dichloromethane), followed by separation on a GEMINI C18 column in the gradient mode with acetate buffer (pH 4.1)/methanol. A triple quadrupole mass spectrometer equipped with a multimode ion source, set to negative atmospheric pressure chemical ionization (APCI) in the multiple reaction monitoring mode was used for detection. The main advantage of this method over other commonly used methods includes the use of SPE with a low volume cartridge for sample preparation and no ion suppression effects from matrix components of the urine samples in the LC–MS/MS analysis. This allowed a reduction the quantification limits (decision limits, CCα) for the first time to 0.1 μg/L (1 and 0.2 μg/L for triamcinolone and flumethasone, respectively). The developed method was validated in accordance with the European Union Commission Decision 2002/657 EC. The recoveries and within-laboratory reproducibility varied from 77% to 115% and 87% to 107.5%, respectively, at 2, 3, and 4 μg/L levels of corticosteroids. The relative standard deviation (RSD) of the measurements was lower than 30%. The decision limit was calculated by multiplying the signal-to-noise ratio by 3 and the obtained values were in the range of 0.1–1.0 μg/L, confirmed by the analysis of twenty blank samples, which were spiked at the desired concentrations. The detection capability was calculated by the addition of the decision limit and the standard deviation followed by multiplication by 1.64 of the within-laboratory reproducibility at 2 μg/L of corticosteroids. The method was applied to four urine samples, giving concentrations of prednisolone (PRED) residues in the range from 0.3 to 0.9 μg/L.  相似文献   

3.
A new method, based on hollow fiber liquid-phase microextraction (HF-LPME) and gas chromatography–tandem mass spectrometry (GC–MSMS), was developed for determination of Δ9-tetrahydrocannabinol (THC), cannabidiol (CBD) and cannabinol (CBN) in samples of human hair. Since hair is a solid matrix, the samples were subjected to alkaline digestion using NaOH. The aqueous solutions obtained were extracted using a 6 cm polypropylene fiber (600 μm i.d., 200 μm wall thickness, 0.2 μm pore size) for each extraction. A 25−1 fractional factorial design for screening, and a central composite design for optimization of significant variables, was applied during development of the extraction method. The variables evaluated were the type of extraction solvent, pH, stirring speed, extraction time, and acceptor phase volume. The optimized conditions for the proposed extraction procedure were 10 mg of hair sample; 20 μL of butyl acetate; aqueous (pH 14) donor phase containing 6.8% NaCl; 600 rpm stirring speed; 20 min extraction time. A linear response was obtained in the ranges 1–500 pg mg−1 (CBD and CBN) and 20–500 pg mg−1 (THC), with regression coefficients >0.99. Precision, determined as the relative standard deviation, was 3.3–8.9% (intra-day) and 4.4–13.7% (inter-day). Absolute recoveries varied in the ranges 4.4–4.8% (CBD), 7.6–8.9% (THC) and 7.7–8.2% (CBN). Limits of detection (LOD, S/N = 3) and quantification (LOQ, S/N = 10) were 0.5–15 pg mg−1 and 1–20 pg mg−1, respectively. The method was successfully used to determine CBD, THC and CBN in hair samples from patients in a drug dependency rehabilitation center. Concentrations varied in the ranges 1–18 pg mg−1 (CBD), 20–232 pg mg−1 (THC) and 9–107 pg mg−1 (CBN), confirming the suitability of the method for monitoring studies.  相似文献   

4.
Tetramethylene disulfotetramine (tetramine) is a rodenticide associated with numerous poisonings was extracted and quantified in human urine using both gas chromatography/mass spectrometry (GC/MS) and GC/tandem mass spectrometry (MS/MS). 1200 μL samples were prepared using a 13C4-labeled internal standard, a 96-well format, and a polydivinyl-benzene solid phase extraction sorbent bed. Relative extraction recovery was greater than 80% at 100 ng/mL. Following extraction, samples were preconcentrated by evaporation at 60 °C, and reconstituted in 50 μL acetonitrile. One-microliter was injected in a splitless mode on both instruments similarly equipped with 30 m × 0.25 mm × 25 μm, 5% phenyl-methylpolysiloxane gas chromatography columns. A quantification ion and a confirmation ion (GC/MS) or analogous selected reaction monitoring transitions (GC/MS/MS) were integrated for all reported results. The method was characterized for precision (5.92–13.4%) and accuracy (96.4–111%) using tetramine-enriched human urine pools between 5 and 250 ng/mL. The method limit of detection was calculated to be 2.34 and 3.87 ng/mL for GC/MS and GC/MS/MS, respectively. A reference range of 100 unexposed human urine samples was analyzed for potential endogenous interferences on both instruments—none were detected. Based on previous literature values for tetramine poisonings, this urinary method should be suitable for measuring low, moderate, and severe tetramine exposures.  相似文献   

5.
A sensitive and rapid HTLC–ESI-MS/MS method with an advanced online sample preparation was developed for determination of the γ-secretase inhibitor MK-0752 in human plasma using an internal standard. Plasma samples (100 μL) were diluted and injected directly onto an online extraction column (Cohesive Cyclone MAX 0.5 mm × 50 mm, >30 μm), the sample matrix was washed out with an aqueous solution, and retained analytes were eluted out and transferred directly to the analytical column (Phenomenex Gemini 3μ C18 110A, 50 mm × 2.0 mm at 50 °C) for separation using a gradient mobile phase. The eluted analytes were then detected on an API-3000 LC–MS/MS System with ESI and a negative multiple reaction monitoring mode. The monitored ion transitions were m/z 441 → 175 for MK-0752 and 496 → 175 for the internal standard. Online extraction recoveries were 81%. The method was validated and was linear in the range of 0.05–50 μg/mL. Within-day and between-day precisions were < 8.6%, and accuracies were 0.7 and 7.1%. This method was applied to the measurement of plasma MK-0752 levels in a Phase I study of pediatric patients with recurrent or refractory brain tumors.  相似文献   

6.
Measurement of organophosphorus (OP) pesticide metabolites in human biological fluids is an important biomarker of pesticides exposure. We measured the urinary excretion of OP pesticide metabolites to evaluate occupational and non-occupational exposure to OP pesticides in the Chinese population in Shanghai (Eastern China). We collected urine samples from 30 exposed workers in a dimethoate emulsion packing division and from 60 healthy adults without any report of occupational exposure. DMP, DMTP, DMDTP, DEP, DEDP and DEDTP were measured by GC-FPD after derivatization with pentafluorobenzyl bromide. The LOQ values (1 mL urine) were 2.0 μg/L for DMP and DETP, 4.0 μg/L for DEP and DEDTP, 8.0 μg/L for DMDTP, and 10.0 μg/L for DMTP. Dimethyl phosphates were detected in the majority of the urine samples, i.e., 90–100% in the exposed group and 80–87% in the control group. The concentration of the urinary diethyl phosphates DEP and DETP was above the LOQ values in 40 and 20% of samples for the exposed group, and in 50 and 30% of the samples for the control group, respectively. DEDTP was not detectable in the urine samples except for a post-shift exposed worker (detection frequency, 6.7%). Median creatinine-adjusted values (μg/g cr.) for DAP in Chinese with pre-shift, post-shift and without occupational exposure to OP were 316, 584 and 170 for DMP, below LOQ, 115 and 114 for DEP, 840, 1730 and 693 for DMTP, and 255, 756 and 135 for DMDTP, respectively. In all subjects, the highest excretion levels were found for DMTP. Several OP pesticide metabolites were frequently detected in urine samples of both populations studied.  相似文献   

7.
We report a rapid and simple HPLC method with fluorescence detection for the quantification of the major flaxseed lignan, secoisolarisiresinol diglucoside (SDG) and its major metabolites. The method is specific for SDG, secoisolarisiresinol (SECO), enterodiol (ED) and entrolactone (EL) in rat serum. The assay procedure involves chromatographic separation using a Waters Symmetry C18 reversed-phase column (4.6 mm × 150 mm, 5 μm) and mobile phase gradient conditions consisting of acetonitrile (0.1% formic acid) and water (0.1% formic acid). SDG extraction from serum requires the use of Centrifuge filters while SECO, ED and EL are extracted with diethyl ether. The organic layer is evaporated and reconstituted in 100 μL of mobile phase and 50 μL of reconstituted sample or filtrate is injected onto the column. Total run time is 25 min. Calibration curves are linear (r2 ≥ 0.997) from 0.05 to 10 μg/mL for SDG and EL and 0.01–10 μg/mL for SECO and ED. Precision and accuracy are within USFDA specified limits. The stability of all lignans is established in auto-injector, bench-top, freeze–thaw and long-term stability at −80 °C for 30 days. The method's reasonable sensitivity and reliance on more widely available HPLC technology should allow for its straightforward application to pharmacokinetic evaluations of lignans in animal model systems such as the rat.  相似文献   

8.
This study reports a sensitive analytical method suitable for the quantitative analysis of ethylenethiourea (ETU) in human urine and its application to samples from the general population. Sample preparation involved the use of diatomaceous earth extraction columns to remove matrix interferences. Quantification was achieved by liquid chromatography–mass spectrometry using positive ion atmospheric pressure chemical ionisation. Within-day and between-day variability of 14% (n = 10) and 11% (n = 6), respectively, were obtained at 98 nmol/l (10 μg l−1). The assay was linear over the investigated range 2.5–245 nmol/l, with a limit of detection of 2.5 nmol/l. The method was applied to monitoring background levels of ETU in urine samples from the general population in the UK. Results obtained from 361 spot samples contained ETU levels ranging from less than the detection limit (54% of samples) to a maximum of 15.8 μmol/mol creatinine (14.3 μg/g creatinine). The 95th percentile was 5.7 μmol/mol creatinine (5.2 μg/g creatinine).  相似文献   

9.
10.
A method based on liquid-liquid-liquid microextraction combined with corona discharge ion mobility spectrometry was developed for the analysis of amantadine in human urine and plasma samples. Amantadine was extracted from alkaline aqueous sample as donor phase through a thin phase of organic solvent (n-dodecane) filling the pores of the hollow fiber wall and then back extracted into the organic acceptor phase (methanol) located in the lumen of the hollow fiber. All variables affecting the extraction of analyte including acceptor organic solvent type, concentration of NaOH in donor phase, ionic strength of the sample and extraction time were studied. The linear range was 20-1000 and 5-250 ng/mL for plasma and urine, respectively (r(2)≥0.990). The limits of detection were calculated to be 7.2 and 1.6 ng/mL for plasma and urine, respectively. The relative standard deviation was lower than 8.2% for both urine and plasma samples. The enrichment factors were between 45 and 54. The method was successfully applied for the analysis of amantadine in urine and plasma samples.  相似文献   

11.
A sensitive and selective capillary electrophoresis method is developed, for the first time, for effective separation and simultaneous determination of aminomethylbezoic acid (PAMBA), cefminox sodium (CMNX) and etamsylate (ETM). The electrophoresis conditions were investigated and optimized. A 25 mM phosphate solution (pH 8.5) was used as a buffer and the peak area was determined with UV detection at 216 nm wavelength under 18 kV separation voltage. Under optimal conditions, the three drugs can be separated effectively. Good linearity was achieved in 3.13–150 μg/mL for PAMBA, 6.25–150 μg/mL for CMNX and 3.13–150 μg/mL for ETM, with the correlation coefficients of >0.999. The limit of detection (LOD) for PAMBA, CMNX and ETM was 1.04, 2.08 and 1.04 μg/mL, respectively. Their recoveries in human urine were in the range from 90.2% to 101% with the RSD (n = 5) of 0.7–3.1%. The proposed method is simple, rapid and accurate, and provides the sensitivity and linearity necessary for analysis of the test drugs in human urine at clinically relevant concentrations.  相似文献   

12.
In this article, we describe a simple, sensitive, accurate, and repeatable method for the measurement of phenol and p-cresol (4-methylphenol) in human urine and feces. We examined a number of parameters to identify an optimal extraction protocol. Purification of sample extracts was achieved by low-temperature vacuum microdistillation. Separation was achieved in approximately 15 min by high-performance liquid chromatography (HPLC) with quantification by fluorescence at 284/310 nm. Limits of detection for phenol were 2 ng/ml for urine and 20 ng/g for feces, and those for p-cresol were 10 ng/ml for urine and 100 ng/g for feces. For comparison, approximate mean values for urine are 3 μg/ml for phenol and 30 μg/ml for p-cresol, and those for feces are 1 μg/g for phenol and 50 μg/g for p-cresol. An experienced analyst can process 60 samples each day using this method.  相似文献   

13.
A rapid, inexpensive, sensitive and specific HPLC-ECD method for the determination of lipoic acid in human plasma was developed and validated over the linearity range of 0.001–10 μg/ml using naproxen sodium as an internal standard (IS). Extraction of lipoic acid and IS from plasma (250 μl) was carried out with a simple one step liquid–liquid extraction using dichloromethane. Similarly solid-phase extraction was carried out using dichloromethane as extraction solvent. The separated organic layer was dried under the stream of nitrogen at 40 °C and the residue was reconstituted with the mobile phase. Complete separation of both lipoic acid and IS at 30 °C on Discovery HS C18 RP column (250 mm × 4.6 mm, 5 μm) was achieved in 6 min using 0.05 M phosphate buffer (pH 2.5 adjusted with phosphoric acid):acetonitrile (50:50, v/v) as a mobile phase pumped at the rate of 1.5 ml/min using electrochemical detector in DC mode at the detector potential of 1.0 V. The limit of detection and limit of quantification of lipoic acid were 200 pg/ml and 1 ng/ml, respectively. While on column limit of detection and limit of quantification of lipoic acid were 10 and 50 pg/ml, respectively. The absolute recoveries of lipoic acid with liquid–liquid and solid-phase extraction were 98.43, 95.65, 101.45, and 97.36, 102.73, 100.17% at 0.5, 1 and 5 μg/ml levels, respectively. Coefficient of variations for both intra-day and inter-day were between 0.28 and 4.97%. The method is validated and will be quite suitable for the analysis of lipoic acid in the plasma of human volunteers as well as patients with diabetes and cardiovascular diseases.  相似文献   

14.
The steroidal liver X receptor agonist, 3α,6α,24-trihydroxy-24,24-di(trifluoromethyl)-5β-cholane (ATI-829) is a potential therapeutic agent for the treatment of atherosclerosis. A sensitive and selective liquid chromatography–tandem mass spectrometry (LC–MS–MS) method for the quantification of ATI-829 in mouse plasma was developed and validated. Proteins in a 25 μL aliquot of mouse plasma were precipitated, and ATI-829 was extracted from the precipitate by the addition of 125 μL methanol. The overall extraction efficiency was greater than 99%. LC–MS–MS with negative ion electrospray and selected reaction monitoring was used for the quantitative analysis of ATI-829. The lower limit of quantitation of ATI-829 corresponded to 5.0 ng/mL (9.7 nM) plasma. Interference from matrix was negligible. The calibration curve was linear over the range 5–2000 ng/mL. The intra-day precision and inter-day precision of the analyses were <4.5% and <6%, respectively, and the accuracy ranged from 92% to 103%. ATI-829 in plasma was stable for at least 6 h at room temperature, 1 week at 4 °C, and 3 weeks at −20 °C. The validated method was then utilized for pharmacokinetic studies of ATI-829 administered to mice.  相似文献   

15.
A rapid and selective high performance liquid chromatography–tandem mass spectrometry (HPLC–MS/MS) method for simultaneous determination of isoniazid (INH), rifampicin (RFP) and levofloxacin (LVX) in mouse tissues and plasma has been developed and validated, using gatifloxacin as the internal standard (I.S.). The compounds and I.S. were extracted from tissue homogenate and plasma by a protein precipitation procedure with methanol. The HPLC separation of the analytes was performed on a Welch materials C4 column (250 mm × 4.6 mm, 5.0 μm, USA) at 25 °C, using a gradient elution program with the initial mobile phase constituting of 0.05% formic acid and methanol (93:7, v/v) at a flow-rate of 1.0 ml/min. For all the three analytes, the recoveries varied between 83.3% and 98.8% in tissues and between 75.5% and 90.8% in plasma, the accuracies ranged from 91.7% to 112.0% in tissues and from 94.6% to 108.8% in plasma, and the intra- and inter-day precisions were less than 13.3% in tissues and less than 8.2% in plsama. Calibration ranges for INH were 0.11–5.42 μg/g in tissues and 0.18–9.04 μg/ml in plasma, for RFP were 0.12–1200 μg/g in tissues and 4.0–200 μg/ml in plasma, and for LVX were 0.13–26.2 μg/g in tissues and 0.09–4.53 μg/ml in plasma. The lower limits of quantification (LLOQs) for INH, RFP and LVX in mouse tissues were 0.11, 0.12 and 0.13 μg/g and for those in mouse plasma were 18.1, 20.0 and 21.8 ng/ml, respectively. The limits of detection (LODs) for INH, RFP and LVX in mouse tissues were 0.04, 0.05 and 0.05 μg/g and for those in mouse plasma were 5.5, 6.0 and 6.6 ng/ml, respectively. The established method was successfully applied to simultaneous determination of isoniazid, rifampicin and levofloxacin in mouse plasma and different mouse tissues.  相似文献   

16.
Among endocrine disruptors, the xenoestrogen bisphenol A (BPA) deserves particular attention due to widespread human exposure. Besides hormonal effects, BPA has been suspected to be responsible for adverse effect on reproductive ability of various species. In the present study the effect of BPA on the quality parameters, oxidative stress, the DNA integrity and intracellular ATP content of sterlet (Acipenser ruthenus) spermatozoa were investigated in vitro. Fish spermatozoa were exposed to concentrations of BPA possibly occurring in nature (0.5, 1.75, 2.5, 5 and 10 μg/L) for 2 h. Results revealed that BPA significantly decreased spermatozoa motility and velocity of spermatozoa at concentration of BPA 2.5–10 μg/L. Significant positive correlation (r = 0.713, P < 0.05) was found between percent motile spermatozoa and ATP content. Oxidative stress was observed at concentrations 1.75–10 μg/L, as reflected by significantly higher levels of protein and lipid oxidation and superoxide dismutase activity. Intracellular ATP content of spermatozoa decreased with increasing concentrations of BPA. A dramatic increase in DNA fragmentation expressed as percent tail DNA (2.2% ± 0.46) and Olive tail moment (0.37 ± 0.09 arbitrary units) was recorded at concentrations of 1.75 μg/L and above. The present study confirms that concentrations of BPA that can be encountered in nature are capable to induce oxidative stress, leading to impaired sperm quality, DNA fragmentation and intracellular ATP content.  相似文献   

17.
We report a sensitive and robust method to determine cholic acid (CA), chenodeoxycholic acid (CDCA), deoxycholic acid (DCA), lithocholic acid (LCA), ursodeoxycholic acid (UDCA), and their taurine- and glycine-conjugate concentrations in human plasma using liquid chromatography–tandem mass spectrometry. Activated charcoal was utilized to prepare bile acid-free plasma, which served as the biological matrix for the preparation of standard and quality control samples. Plasma sample preparation involved solid-phase extraction. A total of 16 bile acids and 5 internal standards were separated on a reverse column by gradient elution and detected by tandem mass spectrometry in negative ion mode. The calibration curve was linear for all the bile acids over a range of 0.005–5 μmol/L. The extraction recoveries for all the analytes fell in the range of 88–101%. Intra-day and inter-day coefficients of variation were all below 10%. A stability test showed that all the bile acids were stable in plasma for at least 6 h at room temperature, at least three freeze–thaw cycles, in the −70 °C or −20 °C freezer for 2 months, and also in the reconstitution solution at 8 °C for 48 h. Comparison of the matrix effect of bile acid-free plasma with that of real plasma indicated that the charcoal purification procedure did not affect the properties of charcoal-purified plasma as calibration matrix. This method has been used to determine the bile acid concentrations in more than 300 plasma samples from healthy individuals. In conclusion, this method is suitable for the simultaneous quantification of individual bile acids in human plasma.  相似文献   

18.
In this paper, a method for the sensitive and reproducible analysis of lignocaine and its four principal metabolites, monoethylxylidide (MEGX), glycylxylidide (GX), 3-hydroxylignocaine (3-HO-LIG), 4-hydroxylignocaine (4-HO-LIG) in equine urine and plasma samples is presented. The method uses liquid chromatography coupled to tandem mass spectrometry operating in electrospray ionisation positive ion mode (+ESI) via multiple reaction monitoring (MRM). Sample preparation involved solid-phase extraction using a mixed-mode phase. The internal standard adopted was lignocaine-d10. Lignocaine and its metabolites were successfully resolved using an octadecylsilica reversed-phase column using a gradient mobile phase of acetonitrile and 0.1% (v/v) aqueous formic acid at a flow rate of 300 μL/min. Target analytes and the internal standard were determined by using the following transitions; lignocaine, 235.2 > 86.1; 3-HO-LIG and 4-HO-LIG, 251.2 > 86.1; MEGX, 207.1 > 58.1; GX, 179.1 > 122.1; and lignocaine-d10, 245.2 > 96.1. Calibration curves were generated over the range 1–100 ng/mL for plasma samples and 1–1000 ng/mL for urine samples. The method was validated for instrument linearity, repeatability and detection limit (IDL), method linearity, repeatability, detection limit (MDL), quantitation limit (LOQ) and recovery. The method was successfully used to analyse both plasma and urine samples following a subcutaneous administration of lignocaine to a thoroughbred horse.  相似文献   

19.
We describe an ultra high performance liquid chromatography–tandem mass spectrometry (UHPLC MS/MS) method suitable for a routine laboratory to determine endogenous and exogenous glucocorticoids in plasma, plasma ultrafiltrate, urine and saliva in a single analytical run. After addition of a multi-analyte internal standard, a standardised sample preparation procedure with solid phase extraction followed, before injecting into a tandem mass spectrometer with positive mode electron spray ionisation and multiple reactant monitoring acquisition. The chromatography time was 3 min. The limit of quantitation for cortisol and cortisone in plasma was 3.75 nmol/L and linearity extended to 2000 nmol/L. The limit of quantitation for cortisol in plasma ultrafiltrate and saliva was 0.6 nmol/L. The limit of quantitation for 11-deoxycortisol and prednisolone was 5 nmol/L and for dexamethasone 1 nmol/L. The intra-assay CV was <5% and the inter-assay CV <10% for all analytes in all matrices. Comparison with an immuno-assay (IA) plasma cortisol method resulted in a regression equation of UHPLC = 0.79 × IA + 31.12 with R2 = 0.960 (p < 0.0001). Comparison with a high performance liquid chromatography (HPLC) cortisol method yielded a regression equation of UHPLC = 1.06 × HPLC + 9.82, R2 = 0.992 (p < 0.0001). The simultaneous measurement of endogenous and exogenous glucocorticoids contributed to patient care in cases with dexamethasone and metyrapone dynamic tests and unsuspected therapeutic glucocorticoid use.  相似文献   

20.
A simple, rapid, sensitive and specific ultra performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS) method was developed and validated for the quantification of ethosuximide in human plasma is described. Analyte was chromatographed on a Hypersil Gold C18 column (100 mm × 2.1 mm, i.d., 1.9 μm) with isocratic elution at a flow rate of 0.250 mL/min and pravastatin was used as the internal standard. The assay involves a simple solid-phase extraction procedure of 0.25 mL human plasma and the analysis was performed on a triple-quadrupole tandem mass spectrometer by MRM mode via electrospray ionization (ESI). The method was linear in the concentration range of 0.25–60.0 μg/mL. The lower limit of quantification (LLOQ) was 0.25 μg/mL. The within- and between-day precision and accuracy of the quality control samples were within 10.0%. The recovery was 95.1% and 94.4% for ethosuximide and pravastatin, respectively. The analysis time for each sample was 1.8 min. The method was highly reproducible and gave peaks with excellent chromatography properties.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号