首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Screen-printed amperometric glucose biosensors have been fabricated using a water-based carbon ink. The enzyme glucose oxidase (GOD) and the electro-catalyst cobalt phthalocyanine were mixed with the carbon ink prior to the screen-printing process; therefore, biosensors are prepared in a one-step fabrication procedure. Optimisation of the biosensor performance was achieved by studying the effects of pH, buffer strength, and applied potential on the analytical response. Calibration studies were performed under optimum conditions, using amperometry in stirred solution, with an operating potential of +500 mV versus SCE. The sensitivity was found to be 1170 nA mM(-1), with a linear range of 0.025-2 mM; the former represents the detection limit. The disposable amperometric biosensor was evaluated by carrying out replicate determinations on a sample of bovine serum. This was achieved by the method of multiple standard additions and included a correction for background currents arising from oxidizable serum components. The mean serum concentration was calculated to be 8.63 mM and compared well with the supplier's value of 8.3 mM; the coefficient of variation was calculated to be 3.3% (n=6).  相似文献   

2.
Amperometric glucose biosensors utilizing commercially available FAD-dependent glucose dehydrogenases from two strains of Aspergillus species are described. Enzymes were immobilized on nanocomposite electrode consisting of multi-walled carbon nanotubes by entrapment between chitosan layers. Unlike the common glucose oxidase based biosensor, the presented biosensors appeared to be O(2)-independent. The optimal amount of enzymes, working potential and pH value of working media of the glucose biosensors were determined. The biosensor utilizing enzyme isolated from Aspergillus sp. showed linearity over the range from 50 to 960 μM and from 70 to 620 μM for enzyme from Aspergillus oryzae. The detection limits were 4.45 μM and 4.15 μM, respectively. The time of response was found to be 60 s. The biosensors showed excellent operational stability - no loss of sensitivity after 100 consecutive measurements and after the storage for 4 weeks at 4 °C in phosphate buffer solution. When biosensors were held in a dessicator at room temperature without use, they kept the same response ability at least after 6 months. Finally, the results obtained from measurements of beverages and wine samples were compared with those obtained with the enzymatic-spectrophotometric and standard HPLC methods, respectively. Good correlation between results in case of analysis of real samples and good analytical performance of presented glucose biosensor allows to use presented concept for mass production and commercial use.  相似文献   

3.
In the present study, we demonstrate the use of a disposable luciferase‐based microfluidic bioassay chip for environmental monitoring and methods for fabrication. The designed microfluidic system includes a chamber with immobilized enzymes of bioluminescent bacteria Photobacterium leiognathi and Vibrio fischeri and their substrates, which dissolve after the introduction of the water sample and thus activate bioluminescent reactions. Limits of detection for copper (II) sulfate, 1,3‐dihydroxybenzene and 1,4‐benzoquinone for the proposed microfluidic biosensor measured 3 μM, 15 mM, and 2 μM respectively, and these values are higher or close to the level of conventional environmental biosensors based on lyophilized bacteria. Approaches for entrapment of enzymes on poly(methyl methacrylate) (PMMA) plates using a gelatin scaffold and solvent bonding of PMMA chip plates under room temperature were suggested. The proposed microfluidic system may be used with some available luminometers and future portable luminescence readers.  相似文献   

4.
A novel disposable biosensor based on direct electron transfer of superoxide dismutase (SOD) was fabricated for the determination of superoxide anion. The biosensor was constructed by electrodeposition of gold nanoparticles (GNPs) on the indium tin oxide (ITO) electrode and then immobilization of SOD in silica sol–gel (SG) network in the presence of cysteine on GNPs/ITO modified electrode surface. The distribution of GNPs on ITO electrode surface was examined by scanning electron microscopy (SEM). The immobilized SOD exhibited high catalytical activity towards superoxide anion. Parameters affecting the performance of the biosensor were also investigated. A linear calibration curve was obtained over the range from 0.08 to 0.64 μM with a correlation coefficient of 0.9937. The resulted biosensors were demonstrated to possess striking analytical properties for superoxide anion determination, such as high sensitivity, good accuracy, and long-term stability. It provides a promising platform for the fabrication of disposable biosensors.  相似文献   

5.
An automated system with semi on-line monitoring of glucose, lactic acid, protein, and optical density during lactic acid fermentations, is set up to study the dynamics of lactic acid bacteria. The analyzers for glucose, lactic acid, and protein are based on flow injection analysis (FIA). The system consists of a laboratory fermentor with a continuous withdrawal system and an analysis system where glucose, lactic acid, and protein concentration are measured together with the optical density of the fermentor sample. The system is controlled by a personal computer.The system response is fast, and it yields a large number of reliable and precise analytical data, whoch is of great importance for mathematical model building. Some premliminary results are shown.  相似文献   

6.
An amperometric glucose biosensor was designed for the detection of glucose in blood, urine, beverages, and fermentation systems. In typical glucose biosensors that employ enzymes, mediators are used for efficient electron transfer between the enzymes and the electrode. However, some of these mediators are known to be toxic to the enzymes and also must be immobilized on the surface of the electrode. We propose a mediator-free glucose biosensor that uses a glucose oxidase immobilized on a tin oxide electrode. Direct electron transfer is possible in this system because the tin oxide has redox properties similar to those of mediators. The method for immobilization of the glucose oxidase onto the tin oxide is also very simple. Tin oxide was prepared by the anodization and annealing of pure tin, and this provides a large surface area for the immobilization step because of its porosity. Glucose oxidase was immobilized onto the tin oxide using the membrane entrapment method. The proposed method provides a simple process for fabricating the enzyme electrode. Glucose oxidase immobilized onto the tin oxide, prepared in accordance with this method, has a relatively large current response when comparedto those of other glucose biosensors. The sensitivity of the biosensor was 19.55 μA/mM, and a linear response was observed between 0∼3 mM glucose. This biosensor demonstrated good reproducibility and stability.  相似文献   

7.
Many high‐value added recombinant proteins, such as therapeutic glycoproteins, are produced using mammalian cell cultures. In order to optimize the productivity of these cultures it is important to monitor cellular metabolism, for example the utilization of nutrients and the accumulation of metabolic waste products. One metabolic waste product of interest is lactic acid (lactate), overaccumulation of which can decrease cellular growth and protein production. Current methods for the detection of lactate are limited in terms of cost, sensitivity, and robustness. Therefore, we developed a whole‐cell Escherichia coli lactate biosensor based on the lldPRD operon and successfully used it to monitor lactate concentration in mammalian cell cultures. Using real samples and analytical validation we demonstrate that our biosensor can be used for absolute quantification of metabolites in complex samples with high accuracy, sensitivity, and robustness. Importantly, our whole‐cell biosensor was able to detect lactate at concentrations more than two orders of magnitude lower than the industry standard method, making it useful for monitoring lactate concentrations in early phase culture. Given the importance of lactate in a variety of both industrial and clinical contexts we anticipate that our whole‐cell biosensor can be used to address a range of interesting biological questions. It also serves as a blueprint for how to capitalize on the wealth of genetic operons for metabolite sensing available in nature for the development of other whole‐cell biosensors. Biotechnol. Bioeng. 2017;114: 1290–1300. © 2017 The Authors. Biotechnology and Bioengineering Published by Wiley Periodicals, Inc.  相似文献   

8.
Novel planar glucose biosensors to be used for continuous monitoring have been developed. The electrodes are produced with the "screen printing" technique, and present a high degree of reproducibility together with a low cost and the possibility of mass production. Prior to enzyme immobilisation, electrodes are chemically modified with ferric hexacyanoferrate (Prussian Blue). This allows the detection of the hydrogen peroxide produced by the enzymatic reaction catalysed by GOD, at low applied potential (ca. 0.0 V versus Ag/AgCl), highly limiting any electrochemical interferences. The layer of Prussian Blue (PB) showed a high stability at the working conditions (pH 7.4) and also after 1 year of storage dry at RT, no loss of activity was observed. The assembled glucose biosensors, showed high sensitivity towards glucose together with a long-term operational and storage stability. In a continuous flow system, with all the analytical parameters optimised, the glucose biosensors detected glucose concentration as low as 0.025 mM with a linear range up to 1.0mM. These probes were also tested over 50-60 h in a continuous flow mode to evaluate their operational stability. A 0.5 mM concentration of glucose was continuously fluxed into a biosensor wall-jet cell and the current due to the hydrogen peroxide reduction was continuously monitored. After 50-60 h, the drift of the signal observed was around 30%. Because of their high stability, these sensors suggest the possibility of using such biosensors, in conjunction with a microdialysis probe, for a continuous monitoring of glucose for clinical purposes.  相似文献   

9.
Integrating graphene-based composites with enzyme provides a potent strategy to enhance biosensor performance due to their unique physicochemical properties. Herein we report on the utilization of graphene-CdS (G-CdS) nanocomposite as a novel immobilization matrix for the enzymes, which glucose oxidase (GOD) was chosen as model enzyme. In comparison with the graphene sheet and CdS nanocrystal, G-CdS nanocomposite exhibited excellent electron transfer properties for GOD with the rate constant (k(s)) of 5.9 s(-1) due to the synergy effect of graphene sheet and CdS nanocrystals. Further, based on the decrease of the electrocatalytic response of the reduced form of GOD to dissolved oxygen, the obtained glucose biosensor displays satisfactory analytical performance over an acceptable linear range from 2.0 to 16 mM with a detection limit of 0.7 mM, and also prevents the effects of interfering species, which is suitable for glucose determination by real samples. These results mean that this immobilization matrix not only can be used for immobilizing GOD, but also can be extended to other enzymes and bioactive molecules, thus providing a promising platform for the development of biosensors.  相似文献   

10.
This article deals with the use of pyranose oxidase (PyOx) and glucose oxidase (GOx) enzymes in amperometric biosensor design and their application in monitoring fermentation processes with the combination of flow injection analysis (FIA). The amperometric studies were carried out at -0.7 V by following the oxygen consumption due to the enzymatic reactions for both batch and FIA modes. Optimization studies (enzyme amounts and pH) and analytical parameters such as linearity, repeatability, effect of interference, storage, and operational stabilities have been studied. Under optimized conditions, for the PyOx-based biosensor, linear graph was obtained from 0.025 to 0.5 mM glucose in phosphate buffer (50 mM) at pH 7.0 with the equation of y = 3.358x + 0.028 and R(2) = 0.998. Linearity was found to be 0.01-1.0 mM in citrate buffer (50 mM and pH 4.0) with the equation of y = 1.539x + 0.181 and R(2) = 0.992 for the GOx biosensor. Finally, these biosensor configurations were further evaluated in a conventional flow injection system. Results from batch experiments provide a guide to design sensitive, stable, and interference-free biosensors for FIA mode. Biosensor stability, dynamic range, and repeatability were also studied in FIA conditions, and the applicability for the determination of glucose in fermentation medium could be successfully demonstrated. The FIA-combined glucose biosensor was used for the offline monitoring of yeast fermentation. The obtained results correlated well with HPLC measurements.  相似文献   

11.
The lack of specific, low-cost, rapid, sensitive, and easy detection of biomolecules has resulted in the development of biosensor technology. Innovations in biosensor technology have enabled many biosensors to be commercialized and have enabled biomolecules to be detected onsite. Moreover, the emerging technologies of lab-on-a-chip microdevices and nanosensors offer opportunities for the development of new biosensors with much better performance. Biosensors were first introduced into the laboratory by Clark and Lyons. They developed the first glucose biosensor for laboratory conditions. Then in 1973, a glucose biosensor was commercialized by Yellow Springs Instruments. The commercial biosensors have small size and simple construction and they are ideal for point-of-care biosensing. In addition to glucose, a wide variety of metabolites such as lactate, cholesterol, and creatinine can be detected by using commercial biosensors. Like the glucose biosensors (tests) other commercial tests such as for pregnancy (hCG), Escherichia coli O157, influenza A and B viruses, Helicobacter pylori, human immunodeficiency virus, tuberculosis, and malaria have achieved success. Apart from their use in clinical analysis, commercial tests are also used in environmental (such as biochemical oxygen demand, nitrate, pesticide), food (such as glutamate, glutamine, sucrose, lactose, alcohol, ascorbic acid), and biothreat/biowarfare (Bacillus anthracis, Salmonella, Botulinum toxin) analysis. In this review, commercial biosensors in clinical, environmental, food, and biowarfare analysis are summarized and the commercial biosensors are compared in terms of their important characteristics. This is the first review in which all the commercially available tests are compiled together.  相似文献   

12.
The pH effect of pyrrole electropolymerization in the presence of glucose oxidase (GODx) on the performance and characteristic of galvanostatically fabricated glucose oxidase/polypyrrole (Ppy) biosensor is reported. Preparing the GODx/Ppy biosensors in 0.1 M KCl saline solution with various pH containing 0.05 M pyrrole monomer and 0.5 mg/ml GODx at 382 microA/cm2 current density for 100 mC/cm2 film thickness, both the galvanostatic responses and characteristics of these resulted biosensors were obtained. The results revealed that the galvanostatic glucose biosensor fabricated at neutral pH condition exhibited much higher sensitivity than those fabricated at lower or higher pH conditions, and had a good linearity form zero to 10 mM glucose with the sensitivity of 7 nA/mM. Finally, the long-term stability and the kinetic parameters, Michaelis constant and maximum current, of this biosensor were also reported.  相似文献   

13.
An approach to the glucose determination by amperometric biosensing in wine industry applications is presented. Integrated screen-printed biosensors based on horseradish peroxidase (HRP) and glucose oxidase (GOx) have been developed. The experimental design methodology has been used to find the optimum conditions of the experimental variables, in such a way that a chronoamperometric response specific for glucose was recorded. Under these conditions, repeatability and reproducibility of the modified electrodes have been analyzed. The detection limit for glucose has been calculated taking into account the probability of false positive (alpha) and negative (beta), reaching a medium value of 4.37+/-0.21 micromol dm-3 (alpha=beta=0.05, and a replicate n=4). The biosensor was applied to the determination of glucose in white wine samples.  相似文献   

14.
Mammalian cell‐based bioprocesses are used extensively for production of therapeutic proteins. Off‐line monitoring of such cultivations via manual sampling is often labor‐intensive and can introduce operator‐dependent error into the process. An integrated multi‐functional off‐line analyzer, the BioProfile FLEX (NOVA Biomedical, Waltham MA) has been developed, which combines the functionality of three off‐line analyzers (a cell counter, an osmometer, and a gas/electrolyte & nutrient/metabolite bio‐profile analyzer) into one device. In addition, a novel automated sampling system has also been developed that allows the BioProfile FLEX to automatically analyze the culture conditions in as many as ten bioreactors. This is the first report on the development and function of this integrated analyzer and an auto‐sampler prototype for monitoring of mammalian cell cultures. Evaluation of the BioProfile FLEX was conducted in two separate laboratories and involved two BioProfile FLEX analyzers and two sets of reference analyzers (Nova BioProfile 400, Beckman‐Coulter Vi‐Cell AS, and Advanced Instruments Osmometer 3900), 13 CHO cell lines and over 20 operators. In general, BioProfile FLEX measurements were equivalent to those obtained using reference analyzers, and the auto‐sampler did not alter the samples it provided to the BioProfile FLEX. These results suggest that the system has the potential to dramatically reduce the manual labor involved in monitoring mammalian cell bioprocesses without altering the quality of the data obtained, and integration with a bioreactor control system will allow feedback control of parameters previously available only for off‐line monitoring. © 2009 American Institute of Chemical Engineers Biotechnol. Prog., 2010  相似文献   

15.
Virus‐like particles (VLPs) are becoming established as vaccines, in particular for influenza pandemics, increasing the interest in the development of VLPs manufacturing bioprocess. However, for complex VLPs, the analytical tools used for quantification are not yet able to keep up with the bioprocess progress. Currently, quantification for Influenza relies on traditional methods: hemagglutination assay or Single Radial Immunodiffusion. These analytical technologies are time‐consuming, cumbersome, and not supportive of efficient downstream process development and monitoring. Hereby we report a label‐free tool that uses Biolayer interferometry (BLI) technology applied on an Octet platform to quantify Influenza VLPs at all stages of bioprocess. Human (α2,6‐linked sialic acid) and avian (α2,3‐linked sialic acid) biotinylated receptors associated with streptavidin biosensors were used, to quantify hemagglutinin content in several mono‐ and multivalent Influenza VLPs. The applied method was able to quantify hemagglutinin from crude samples up to final bioprocessing VLP product. BLI technology confirmed its value as a high throughput analytical tool with high sensitivity and improved detection limits compared to traditional methods. This simple and fast method allowed for real‐time results, which are crucial for in‐line monitoring of downstream processing, improving process development, control and optimization.  相似文献   

16.
The glucose monitor with a screen-printed carbon sensor has been in commercial production since 1994. In last 15 years, around 10 companies have been involved in manufacturing and marketing the meters and glucose test strips and are being strong competitors of the companies which import these products. Comparison of early stage glucose meters and glucose test strips with latest fabrications showed a large increase in production volume and improved functional features. It also showed technological development of glucose monitors including circuit improvement, as more integrated computer processor units (CPU) are now being used. The technology of mass-production of disposable screen-printed test strips has been widely used in local industries mainly for the production of blood glucose test strips. The opportunities and challenges in local diabetes market are discussed in this paper.  相似文献   

17.
Multi-wall carbon nanotubes (MWNTs) functionalized with amino groups were prepared via silane treatment using 3-aminopropyltrimethoxysilane (APS) as a silane-coupling agent. The resultant amino terminated MWNTs (AMWNTs) were applied to construct glucose biosensors with IO(4)(-)-oxidized glucose oxidase (IO(4)(-)-oxidized GOx) through the layer-by-layer (LBL) covalent self-assembly method without any cross-linker. Scanning electron microscopy (SEM) indicated that the assembled AMWNTs were almost in a form of small bundles or single nanotubes, and the surface density increased uniformly with the number of GOx/AMWNTs bilayers. From the analysis of voltammetric signals, a linear increment of the coverage of GOx per bilayer was estimated. The resulting biosensor showed excellent catalytic activity towards the electroreduction of dissolved oxygen at low overvoltage, based on which glucose concentration was monitored conveniently. The enzyme electrode exhibited good electrocatalytic response towards the glucose and that response increased with the number of GOx/AMWNTs bilayers, suggesting that the analytical performance such as sensitivity and detection limit of the glucose biosensors could be tuned to the desired level by adjusting the number of deposited GOx/AMWNTs bilayers. The biosensor constructed with four bilayers of GOx/AMWNTs showed high sensitivity of 7.46muAmM(-1)cm(-2) and the detection limit of 8.0muM, with a fast response less than 10s. Because of relative low applied potential, the interference from other electro-oxidizable compounds was minimized, which improved the selectivity of the biosensors. Furthermore, the obtained enzyme electrodes also showed remarkable stability due to the covalent interaction between the GOx and AMWNTs.  相似文献   

18.
Reduced graphene oxide/PAMAM-silver nanoparticles nanocomposite (RGO-PAMAM-Ag) was synthesized by self-assembly of carboxyl-terminated PAMAM dendrimer (PAMAM-G3.5) on graphene oxide (GO) as growing template, and in-situ reduction of both AgNO(3) and GO under microwave irradiation. The RGO-PAMAM-Ag nanocomposite was used as a novel immobilization matrix for glucose oxidase (GOD) and exhibited excellent direct electron transfer properties for GOD with the rate constant (K(s)) of 8.59 s(-1). The fabricated glucose biosensor based on GOD electrode modified with RGO-PAMAM-Ag nanocomposite displayed satisfactory analytical performance including high sensitivity (75.72 μA mM(-1) cm(-2)), low detection limit (4.5 μM), an acceptable linear range from 0.032 mM to 1.89 mM, and also preventing the interference of some interfering species usually coexisting with glucose in human blood at the work potential of -0.25 V. These results indicated that RGO-PAMAM-Ag nanocomposite is a promising candidate material for high-performance glucose biosensors.  相似文献   

19.
Biosensors containing recombinant carbohydrate oxidase from Microdochium nivale (rMnO) were developed by means of either chemically modified carbon paste or graphite electrode. 1-(N,N-dimethylamine)-4-(4-morpholine)benzene (AMB) and 1,1'-dimethylferrocene (DMFc) have been used as mediators. The biosensors showed a linear calibration graph up to 18 mM of glucose when operated at 0.04-0.36 V versus a saturated calomel electrode. Almost no change was detected in the sensitivity of the biosensors at pH 7.2-8.1. The biosensors responded to other aldoses in the D-configuration, however, maximal sensitivity of the biosensor was towards D-glucose. The biosensor did not response to polyhydroxylic compounds such as D-mannitol, D-sorbitol and inositol. The advantages of the biosensors based on rMnO in comparison to Aspergillus niger glucose oxidase is a wider linear range, low sensitivity to oxygen and (in some cases) broad specificity.  相似文献   

20.
The monitoring and management of blood glucose levels are key components for maintaining the health of people with diabetes. Traditionally, glucose monitoring has been based on indirect detection using electrochemistry and enzymes such as glucose oxidase or glucose dehydrogenase. Here, we demonstrate direct detection of glucose using a surface plasmon resonance (SPR) biosensor. By site-specifically and covalently attaching a known receptor for glucose, the glucose/galactose-binding protein (GGBP), to the SPR surface, we were able to detect glucose binding and determine equilibrium binding constants. The site-specific coupling was accomplished by mutation of single amino acids on GGBP to cysteine and subsequent thiol conjugation. The resulting SPR surfaces had glucose-specific binding properties consistent with known properties of GGBP. Further modifications were introduced to weaken GGBP-binding affinity to more closely match physiologically relevant glucose concentrations (1-30 mM). One protein with a response close to this glucose range was identified, the GGBP triple mutant E149C, A213S, L238S with an equilibrium dissociation constant of 0.5mM. These results suggest that biosensors for direct glucose detection based on SPR or similar refractive detection methods, if miniaturized, have the potential for development as continuous glucose monitoring devices.  相似文献   