共查询到20条相似文献,搜索用时 890 毫秒
1.
Alice J. Szuna Roger W. Blain 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1993,620(2):211-216
Analysis of a new antibacterial agent, Ro 23-9424 (I), in plasma has been complicated by the fact that its metabolite, fleroxacin (II), is formed not only in vivo, but also nonenzymatically by the hydrolysis of the ester bond of I. In order to minimize sample preparation time and possible hydrolysis during sample preparation, a high-performance liquid chromatographic procedure was developed which features direct injection of plasma and multidimensional chromatography. The first dimension size-exclusion separation allows plasma proteins to elute with the column void volume. The second dimension reversed-phase column provides a high-resolution separation dependent upon the hydrophobicity of the sample species. With a 5-μl injection, the limit of quantitation of the method is 0.35 μg/ml for I and 0.27 μg/ml for II. The method was used to determine steady state plasma vs. time profiles for I and II from 750 mg i.v. doses of I administered twice daily. 相似文献
2.
目的:用RP-HPLC方法对注射用重组人尿激酶原制剂蛋白含量进行定量分析。方法:用反相C18柱、0.1%TFA水溶液与0.1%乙腈进行梯度洗脱,280nm波长紫外检测器监测;以重组人尿激酶原同质标准品作为对照品,根据进样量和相应的峰面积建立标准曲线方程,将待测定样品的峰面积代入标准曲线方程,可测得蛋白含量。结果:按照方法学验证要求对此方法进行了专属性、检测限、定量限、线形、精密度(重复性、中间精密度)、准确度(回收率)考察,线性范围为9~27μg,回收率在97%以上,RSD2.0%,完全满足对制剂蛋白的定量需求。结论:本方法准确,适用于注射用重组人尿激酶原成品制剂蛋白定量测定。 相似文献
3.
Balakrishna Maddi Ellen Panisko Karl Albrecht Daniel Howe 《Journal of visualized experiments : JoVE》2016,(109)
Two-dimensional gas chromatography coupled with time-of-flight mass spectrometry is a powerful tool for identifying and quantifying chemical components in complex mixtures. It is often used to analyze gasoline, jet fuel, diesel, bio-diesel and the organic fraction of bio-crude/bio-oil. In most of those analyses, the first dimension of separation is non-polar, followed by a polar separation. The aqueous fractions of bio-crude and other aqueous samples from biofuels production have been examined with similar column combinations. However, sample preparation techniques such as derivatization, solvent extraction, and solid-phase extraction were necessaryprior to analysis. In this study, aqueous fractions obtained from the hydrothermal liquefaction of algae were characterized by two-dimensional gas chromatography coupled with time-of-flight mass spectrometry without prior sample preparation techniques using a polar separation in the first dimension followed by a non-polar separation in the second. Two-dimensional plots from this analysis were compared with those obtained from the more traditional column configuration. Results from qualitative characterization of the aqueous fractions of algal bio-crude are discussed in detail. The advantages of using a polar separation followed by a non-polar separation for characterization of organics in aqueous samples by two-dimensional gas chromatography coupled with time-of-flight mass spectrometry are highlighted. 相似文献
4.
Choi SO Um SY Jung SH Jung SJ Kim JI Lee HJ Chung SY 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2006,830(2):301-305
A direct injection column-switching high-performance liquid chromatography (HPLC) method was developed and validated for quantification of zaltoprofen in rat plasma. Following dilution with mobile phase A, i.e. acetonitrile-10mM potassium phosphate buffer (pH 6.8) (12:88, v/v) samples were directly injected to the pre-column without sample pre-purification step. After endogenous plasma components were eluted to waste, the system was switched and the analyte was eluted to the trap column. Zaltoprofen was then back-flushed to the analytical column for separation with mobile phase B, i.e. acetonitrile-10mM potassium phosphate buffer (pH 6.8) (35:65, v/v) and quantification with an ultraviolet detector at 230 nm. The calibration curve was linear in the concentration range of 40-5000 ngmL(-1). This method has been fully validated and shown to be specific, accurate and precise. The method is simple, rapid and the sample preparation is minimal and appears to be useful for the pharmacokinetic study of zaltoprofen. 相似文献
5.
Petr Jandik Jun Cheng Detlef Jensen Stefan Manz Nebojsa Avdalovic 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,758(2):667
This report describes a new, automated chromatographic procedure eliminating carbohydrates from amino acid samples prior to their analysis by anion-exchange chromatography and integrated amperometric detection. In the first step, a sample is brought onto a short cation-exchange column (trap column) in hydrogen form. Carbohydrates are passing through this column, while only amino acids are retained. Subsequently, the cation-exchange column, holding the amino acid fraction, is switched in-line with the gradient pump and separator column. The mobile phase used at the beginning of the separation (NaOH; pH 12.7) transfers amino acids from the trap column onto the anion-exchange column and the amino acid separation is completed without any interference by carbohydrates. All common amino acids are recovered following the carbohydrate removal step. The average value of their recovery is 88.1%. The calibration plots were tested between 12.5 and 500 pmol (amounts injected). The mean value of correlation coefficients of calibration plots was calculated as 0.99. The mean value of relative standard deviations from five replicates was 3.9%. The usefulness of the method is illustrated with two chromatograms of a carrot juice sample obtained before and after the in-line removal of carbohydrates. 相似文献
6.
Fibrous stationary phase in capillary electrochromatography 总被引:3,自引:0,他引:3
Capillary electrochromatography (CEC) using fibrous cellulose acetate (CA) stationary phase was investigated. The advantage of this fiber-packed column is relatively easy preparation process compared with other conventional CEC columns, such as particle-packed and wall-coated capillaries. CA fibers are manually packed into a capillary with two guide liners and fixed with a frit at the column inlet. The separation characteristics of this column were investigated using n-alkyl p-hydroxybenzoates (parabens) as the sample probe. It has been demonstrated that the use of a short column length and a specially designed tee-connector as the injection device should make the separation performance and efficiency much higher on the fiber-packed columns. Sufficient separation between methyl and n-butylparabens is obtained on the 5-cm-packed column and linear relationships between the injection time and the peak area are observed. Bubble formation is not encountered during the analysis. 相似文献
7.
《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,752(1):133-139
A direct injection column-switching HPLC method was developed and validated for quantification of sanfetrinem in rat and dog plasma. Following dilution with buffer, samples were directly injected onto the system. The analyte was retained in an enrichment column while endogenous plasma components were eluted to waste. Sanfetrinem was then back-flushed to the analytical column for separation and quantification with an ultraviolet detector. Sample batch size was increased by adding a washing phase of the enrichment column and by alternating the injections between two enrichment columns. The method is very simple and sample preparation is minimal. The method has been fully validated and shown to be specific, accurate and reproducible. 相似文献
8.
We propose a two-dimensional sugar map method for the simple, reproducible, and sensitive analysis of the structures of N-linked oligosaccharides. The structure of an unknown oligosaccharide can be characterized from its position on the map. The data base for the sugar map is prepared by the use of 113 kinds of standard oligosaccharides, 58 of whose structures have been confirmed by 1H NMR spectroscopy. The present method involves six steps, (i) preparation of oligosaccharides from glycopeptides by N-oligosaccharide glycopeptidase (almond) digestion, (ii) derivatization of the reducing ends of oligosaccharides with a fluorescent reagent, 2-amino-pyridine, by using sodium cyanoborohydride, (iii) separation of oligosaccharide derivatives by high-performance liquid chromatography with an ODS-silica column, (iv) analysis of the size of each separated oligosaccharide on an amide-silica column, (v) plotting of the elution position of a sample on the two-dimensional sugar map obtained for the standard oligosaccharides, and (vi) structural analysis of the oligosaccharides by a combination of sequential exoglycosidase digestion and the steps (iii-v). The present method was applied to the identification of the structures of oligosaccharides in hen ovalbumin. It was found that two unusual oligosaccharides that have not yet been reported exist in ovalbumin. 相似文献
9.
Rapid and simple high-performance liquid chromatographic determination of nimesulide in human plasma
P. Pt
ek J. Macek J. Klíma 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2001,758(2):183-188
A high-performance liquid chromatographic method for the quantitation of nimesulide in human plasma is presented. The method is based on protein precipitation with methanol and reversed-phase chromatography with spectrophotometric detection at 404 nm. The separation was performed on a Nucleosil 120-5 C18, 50×4-mm I.D. column and the mobile phase consisted of acetonitrile–methanol–15 mM potassium dihydrogenphosphate buffer, pH 7.3 (30:5:65, v/v). Only 250 μl of plasma are used for sample preparation and no internal standard is necessary. The limit of quantitation is 80 ng/ml and the calibration curve is linear up to 10 000 ng/ml. More than 20 samples can be analysed within 1 h. Within-day and between-day precision expressed by relative standard deviation is less than 5% and inaccuracy does not exceed 8%. The assay was used for pharmacokinetic studies. 相似文献
10.
A method is described whereby a large number of chromatographic fractions containing protein or enzyme components may be run on a single-starch gel. A multiple punch for making the sample holes, gel slab support, and a gel slicer used to cut several slices from the one gel for staining for the various enzyme or protien constituents are described. An example is given of a run using fractions obtained from a Sephadex G-200 column chromatography run of a herring muscle extract. Densitometry may be used to assay the stained gels. In another example a commercially obtained muscle lactate dehydrogenase preparation was chromatographed on a Sephadex G-200 column. The electrophoretic run of the fractions revealed the presence of both heart-type A and muscle-type B lactate dehydrogenase subunits and showed that the column run had effected a partial separation of the various tetramers. 相似文献
11.
Inherent problems exist in the use of two-dimensional gel electrophoresis (2-DE) for sample preparation and separation of proteins from Halobacterium salinarum. In particular, proteins from cells grown in 25% NaCl are difficult to resolve by 2-DE due to the abundance of salt. To remove salts, a 3 kDa molecular weight cut-off column was used. When soluble proteins were separated by 2-DE, most of the proteins were concentrated in the acidic range. For separation of proteins in the pH 3-6 range, ultrazoom immobilized pH gradient strips were used. In addition, sample separation using a IPGphor/Multiphor combined system was a more effective method for the proteome analysis of acidic proteins than using IPGphor for the isoelectric focusing step. 相似文献
12.
《Chirality》2017,29(10):579-588
An interesting mode of chromatography for preparation of pure enantiomers from pure samples is the method of stacked injection as a pseudocontinuous procedure. Maximum throughput and minimal production costs can be achieved by the use of total chiral column length in this mode of chromatography. To maximize sample loading, often touching bands of the two enantiomers is automatically achieved. Conventional equations show direct correlation between touching‐band loadability and the selectivity factor of two enantiomers. The important question for one who wants to obtain the highest throughput is “How to optimize different factors including selectivity, resolution, run time, and loading of the sample in order to save time without missing the touching‐band resolution?” To answer this question, tramadol and propranolol were separated on cellulose 3,5‐dimethyl phenyl carbamate, as two pure racemic mixtures with low and high solubilities in mobile phase, respectively. The mobile phase composition consisted of n‐hexane solvent with alcohol modifier and diethylamine as the additive. A response surface methodology based on central composite design was used to optimize separation factors against the main responses. According to the stacked injection properties, two processes were investigated for maximizing throughput: one with a poorly soluble and another with a highly soluble racemic mixture. For each case, different optimization possibilities were inspected. It was revealed that resolution is a crucial response for separations of this kind. Peak area and run time are two critical parameters in optimization of stacked injection for binary mixtures which have low solubility in the mobile phase. 相似文献
13.
Restricted access materials and large particle supports for on-line sample preparation: an attractive approach for biological fluids analysis 总被引:4,自引:0,他引:4
Souverain S Rudaz S Veuthey JL 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2004,801(2):141-156
An analytical process generally involves four main steps: (1) sample preparation; (2) analytical separation; (3) detection; and (4) data handling. In the bioanalytical field, sample preparation is often considered as the time-limiting step. Indeed, the extraction techniques commonly used for biological matrices such as liquid-liquid extraction (LLE) and solid-phase extraction (SPE) are achieved in the off-line mode. In order to perform a high throughput analysis, efforts have been engaged in developing a faster sample purification process. Among different strategies, the introduction of special extraction sorbents, such as the restricted access media (RAM) and large particle supports (LPS), allowing the direct and repetitive injection of complex biological matrices, represents a very attractive approach. Integrated in a liquid chromatography (LC) system, these extraction supports lead to the automation, simplification and speeding up of the sample preparation process. In this paper, RAM and LPS are reviewed and particular attention is given to commercially available supports. Applications of these extraction supports, are presented in single column and column-switching configurations, for the direct analysis of compounds in various biological fluids. 相似文献
14.
Tae-Joon Park Ji-Sun Kim Sung-Sub Choi Yongae Kim 《Biotechnology and Bioprocess Engineering》2011,16(3):477-481
The amyloid precursor protein (APP) is an integral transmembrane protein which has been suggested to play a central role in
the pathogenesis of Alzheimer’s disease. Despite the enormous amount of research conducted on amyloid protein, the precise
mechanism of its toxic effect is not yet fully understood. To better understand the mechanism and function of amyloid protein,
it is critical to elucidate the three-dimensional structure of the single transmembrane spanning region of human APP (hAPP-TM).
Unfortunately, it is difficult to prepare the peptide sample because hAPP-TM is a membrane-bound protein that transverses
the lipid bilayer of the cell membrane. Generally, the preparation of a transmembrane peptide is very difficult and time-consuming.
In fact, high yield production of transmembrane peptides has been limited by experimental difficulties related to insufficient
yields and the low solubility of such peptides. In this study, we describe experimental processes developed to optimize the
expression, purification, and NMR measurement conditions for hAPP-TM transmembrane peptide. 相似文献
15.
Huang L Harvie G Feitelson JS Gramatikoff K Herold DA Allen DL Amunngama R Hagler RA Pisano MR Zhang WW Fang X 《Proteomics》2005,5(13):3314-3328
Separation of complex protein mixtures that have a wide dynamic range of concentration, such as plasma or serum, is a challenge for proteomic analysis. Sample preparation to remove high-abundant proteins is essential for proteomics analysis. Immunoglobulin yolk (IgY) antibodies have unique and advantageous features that enable specific protein removal to aid in the detection of low-abundant proteins and biomarker discovery. This report describes the efficiency and effectiveness of IgY microbeads in separating 12 abundant proteins from plasma with an immunoaffinity spin column or LC column. The protein separation and sample preparation process was monitored via SDS-PAGE, 2-DE, LC-MS/MS, or clinical protein assays. The data demonstrate the high specificity of the protein separation, with removal of 95-99.5% of the abundant proteins. IgY microbeads against human proteins can also selectively remove orthologous proteins of other mammals such as mouse, rat, etc. Besides the specificity and reproducibility of the IgY microbeads, the report discusses the factors that may cause potential variations in protein separation such as protein-protein interactions (known as "Interactome"), binding and washing conditions of immunoaffinity reagents, etc. A novel concept of Seppromics is introduced to address methodologies and science of protein separation in a context of proteomics. 相似文献
16.
Räbinä J Mäki M Savilahti EM Järvinen N Penttilä L Renkonen R 《Glycoconjugate journal》2001,18(10):799-805
Analysis of nucleotide sugar metabolism is essential in studying glycosylation in cells. Here we describe practical methods for both extraction of nucleotide sugars from cell lysates and for their analytical separation. Solid-phase extraction cartridges containing graphitized carbon can be used for the purification of nucleotide sugars by using triethylammonium acetate buffer as a ion-pairing reagent for decreasing retention. After that they are separated by high-performance liquid chromatography using a C18 reversed-phase column and the same ion-pairing reagent for increasing retention. These new sample preparation and analysis methods enable good separation of structurally similar sugar nucleotides, compatibility with rapid evaporative concentration, and possibility to automation. Monitoring the production of GDP-deoxyhexoses in genetically engineered yeast and native bacterial cells are described here as specific applications. 相似文献
17.
Jean W. Lee Weng Naidong Thomas Johnson Alan Dzerk Tetsushiro Miyabayashi Michio Motohashi 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》1995,670(2):287-298
Column-switching HPLC methods have been developed and validated for the determination of a new antihypertensive prodrug, TCV-116 (I), and its metabolites, CV-11974 (II) and CV-15959 (III), in human serum and urine. Initial sample cleanup was achieved by extracting the analytes into an organic solvent. After chromatographing on an ODS column with a mobile phase consisting of acetonitrile and an acidic phosphate buffer, the zone of the analyte's retention was heart-cut onto a second ODS column with a mobile phase of acetonitrile and a phosphate buffer at a higher pH. Complete separation of the analytes and the endogenous peaks was accomplished by the two-dimensional chromatography. Good precision and linearity of the calibration standards, as well as the inter-day and intra-day precision and accuracy of quality control samples, were achieved. The limit of quantitation (LOQ), using 0.5 ml of serum, was 2 ng/ml for I, 0.8 ng/ml for II, and 0.5 ng/ml for III. The LOQ for urine sample was 10 ng/ml for II and III. Stability of the analytes during storage, extraction, and chromatography processes was established. The results illustrate the versatile application of column switching to method development of multiple analytes in various biological matrices. The methods have been successfully used for the analyses of I and its metabolites in thousands of clinical samples to provide pharmacokinetics data. 相似文献
18.
19.
Pagliuca G Zironi E Ceccolini A Matera R Serrazanetti GP Piva A 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,819(1):97-103
An analytical method based on high-performance liquid chromatography (HPLC) combined with fluorescence detection (FL) has been developed for the simultaneous determination of fumonisin B1 (FB1) and its totally hydrolized metabolite aminopentol-1 (AP1) in pig liver. The sample preparation is based on a single solid phase extraction (SPE). o-Phthalaldehyde (OPA) was used for pre-column derivatization before the programmed reversed-phase analysis on phenylhexyl column. The developed method shows good repeatibility for inter- and intra-day precision as well as adequate linearity of calibration curves (r2 was 0.9855 for FB1 and 0.9831 for AP1). Average recoveries from the matrix were 93.6% for FB1 and 95.3% for AP1. The limit of quantification (LOQ) in swine liver was 75 microg/kg for FB1 and 42 microg/kg for AP1. 相似文献
20.
S A Berkowitz 《Analytical biochemistry》1987,164(1):254-260
Rapid preparative scale purification of calmodulin from crude bovine brain extract is achieved in a single chromatographic run by physically coupling two different liquid chromatography columns which employ different separation mechanisms. In this case columns packed with newly commercialized 40-microns silica-based hydrophobic interaction and 5-microns micron silica-based weak anion-exchange chromatography media were used. The only sample preparation required for conducting this purification procedure is the addition of salt to the crude brain supernatant to promote the initial binding of calmodulin to the hydrophobic interaction chromatography media. Chromatography carried out on such linear arrangements of columns has been referred to as linear multidimensional liquid chromatography. 相似文献