首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A rapid and sensitive liquid chromatographic/tandem mass spectrometric method for determination of misoprostol acid, the active metabolite of misoprostol, was developed and validated. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a C(18) column. An API 4000 tandem mass spectrometer equipped with Turbo IonSpray ionization source was used as detector and was operated in the negative ion mode. Multiple reaction monitoring using the precursor to product ion combinations of m/z 367-249 and 296-269 was performed to quantify misoprostol acid and the internal standard hydrochlorothiazide, respectively. The method was linear in the concentration range of 10.0-3000 pg mL(-1) using 200 microL plasma. The lower limit of quantification was 10.0 pg mL(-1). The intra- and inter-day relative standard deviation over the entire concentration range was less than 8.3%. Accuracy determined at three concentrations (25.0, 200 and 2700 pg mL(-1) for misoprostol acid) ranged from -0.5 to 1.2% in terms of relative error. Each plasma sample was chromatographed within 3.5 min. The method was successfully used in a pharmacokinetic study of misoprostol in human plasma after an oral administration of 0.6 mg misoprostol.  相似文献   

2.
A sensitive, specific and fast high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) assay for the determination of vinorelbine in mouse and human plasma is presented. A 200 microL aliquot was extracted with solid-phase extraction (SPE) using Bond-Elut C(2) cartridges. Dried extracts were reconstituted in 100 microL 1 mM ammonium acetate pH 10.5-acetonitrile-methanol (21:9:70, v/v/v) containing the internal standard vintriptol (100 ng/mL) and 10 microL volumes were injected onto the HPLC system. Separation was achieved on a 50 mm x 2.0 mm i.d. Gemini C(18) column using isocratic elution with 1 mM ammonium acetate pH 10.5-acetonitrile-methanol (21:9:70, v/v/v) at a flow rate of 0.4 mL/min. HPLC run time was only 5 min. Detection was performed using positive ion electrospray ionization followed by tandem mass spectrometry (ESI-MS/MS). The assay quantifies vinorelbine from 0.1 to 100 ng/mL using human plasma sample volumes of 200 microL. With this method vinorelbine can be measured in mouse plasma samples when these samples are diluted eight times in control human plasma. Calibration samples prepared in control human plasma can be used for the quantification of the drug. The lower limit of quantification in mouse plasma is 0.8 ng/mL. This assay is used to support preclinical and clinical pharmacologic studies with vinorelbine.  相似文献   

3.
A simple and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method using an atmospheric pressure chemical ionization source (APCI) for the quantification of fenretinide (4-HPR) in mouse plasma was developed and validated. After a simple protein precipitation of plasma sample by acetonitrile, 4-HPR was analyzed by LC-APCI-MS/MS. High-performance liquid chromatography (HPLC) separation was conducted on a Hypurity C18 column (50mmx2.1mm, 5microm) with a flow rate 0.60mL/min using a gradient mobile phase comprised of 0.05% formic acid in water (A) and methanol (B), and a run time of 4.5min. The elimination of a tedious sample preparation process and a shorter run time substantially reduced total analysis time. The method was linear over the range 0.5-100ng/mL, with r>0.998. The intra- and inter-assay precisions were 1.4-9.2% and 5.1-8.2%, respectively, and the intra- and inter-assay accuracies were 93.9-98.6% and 92.7-95.3%, respectively. The absolute recoveries were 90.3% (1.5ng/mL), 97.0% (7.5ng/mL) and 92.1% (75.0ng/mL) for 4-HPR, and 99.1% for the internal standard (150ng/mL). The analytical method had excellent sensitivity using a small sample volume (30microL) with the lower limit of quantification (LLOQ) 0.5ng/mL. This method is robust and has been successfully employed in a pharmacokinetic study of 4-HPR in a mouse xenograft model of neuroblastoma.  相似文献   

4.
A rapid, sensitive and specific high performance liquid chromatography-electrospray ionization tandem quadrupole mass spectrometry (HPLC-MS/MS) method was developed and validated for the determination of 3-n-butylphthalide in rat plasma. Following protein precipitation with acetonitrile, 3-n-butylphthalide and glipizide (internal standard, I.S.) were separated using a gradient elution program on a C18 column and detected by mass spectrometry in positive ion mode with the multiple reaction monitoring (MRM) mode using the respective precursor to product ion combinations of m/z 191/145 for 3-n-butylphthalide and m/z 446/321 for glipizide, respectively. The total chromatographic running time was 2.5 min. The method was linear over the concentration range of 11.14-3480.00 ng/mL, using as little as 100 microL plasma. The lower limit of quantification (LLOQ) was 5.57 ng/mL. Finally, the method was successfully used to support a preclinical pharmacokinetic study of 3-n-butylphthalide in rats following intravenous administration.  相似文献   

5.
A sensitive liquid chromatography-mass spectrometric (LC/MS) method for the quantification of schizandrin in rat plasma was developed and validated after solid-phase extraction (SPE). Chromatographic separation was achieved on a reversed-phase Shimadzu C(18) column with the mobile phase of acetonitrile-sodium acetate (10 micromol/L) and step gradient elution resulted in a total run time of about 11.7 min. The analytes were detected using an electrospray positive ionization mass spectrometry in the selected ion monitoring (SIM) mode. A good linear relationship was obtained in the concentration range studied (0.005-2.000 microg/mL) (r=0.9999). Lower limit of quantification (LLOQ) was 5 ng/mL and the lower limit of detection (LLOD) was 2 ng/mL using 100 microL plasma sample. Average recoveries ranged from 75.85 to 88.51% in plasma at the concentrations of 0.005, 0.100 and 1.000 microg/mL. Intra- and inter-day relative standard deviations were 5.95-12.93% and 3.87-14.53%, respectively. This method was successfully applied for the pharmacokinetic studies in rats.  相似文献   

6.
A rapid and sensitive liquid chromatography/mass spectrometry (LC/MS) method was developed and validated for the determination of rimantadine in rat plasma. Rimantadine was extracted by protein precipitation with methanol, and the chromatographic separation was performed on a C(18) column. The total analytical run time was relatively short (4.6 min), and the limit of assay quantification (LLOQ) was 2 ng/mL using 50 microL of rat plasma. Rimantadine and the internal standard (amantadine) were monitored in selected ion monitoring (SIM) mode at m/z 180.2 and 152.1, respectively. The standard curve was linear over a concentration range from 2 to 750 ng/mL, and the correlation coefficients were greater than 0.999. The mean intra- and inter-day assay accuracy ranged from 100.1-105.0% to 100.3-104.0%, respectively, and the mean intra- and inter-day precision was between 1.3-2.3% and 1.8-3.0%, respectively. The developed assay method was successfully applied to a pharmacokinetic study in rats after oral administration of rimantadine hydrochloride at the dose of 20 mg/kg.  相似文献   

7.
A sensitive method for the determination of lapatinib (GW572016) in human plasma was developed using high-performance liquid chromatographic separation with tandem mass spectrometric detection. Plasma samples (100 microL) were prepared using solid phase extraction (SPE) columns, and 6.0 microL of the reconstituted eluate was injected onto a Phenomenex CuroSil-PFP 3 mu analytical column (50 mm x 2.0mm) with an isocratic mobile phase. Analytes were detected with a PE SCIEX API-365 LC-MS/MS system at unit (Q1) and low (Q3) resolution in positive multiple reaction monitoring mode (m/z 581 (precursor ion) to m/z 364 (product ion) for lapatinib). The mean recovery for lapatinib was 75% with a lower limit of quantification of 15 ng/mL (S/N=11.3, CV< or =14%). This method was validated over a linear range of 100-10,000 ng/mL, and results from a 5-day validation study demonstrated good within-day and between-day precision and accuracy. This method has been used to measure plasma lapatinib concentrations in a Phase I study in children with cancer.  相似文献   

8.
A simple, sensitive and rapid liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and validated to quantify griseofulvin in human plasma using propranolol hydrochloride as internal standard (IS). Samples were prepared using solid phase extraction and analysed without drying and reconstitution. The analytes were chromatographed on Hypersil, hypurity C18 reverse phase column under isocratic conditions using 0.05% formic acid in water:acetonitrile (30:70, v/v) as the mobile phase. Total chromatographic run time was 3.0 min. Quantitation was done on a triple quadrupole mass analyzer API-3000, equipped with turbo ion spray interface and operating in multiple reaction monitoring (MRM) mode to detect parent-->product ion transition for analyte and IS. The method was validated for sensitivity, matrix effect, accuracy and precision, linearity, recovery and stability studies. Linearity in plasma was observed over the concentration range 20-3000 ng/mL for griseofulvin. Lower limit of quantification (LLOQ) achieved was 20 ng/mL with precision (CV) less than 10% using 5 microL injection volume. The absolute recovery of analyte (87.36%) and IS (98.91%) from spiked plasma samples was consistent and reproducible. Inter-batch and intra-batch coefficients of variation across four validation runs (LLOQ, LQC, MQC and HQC) was less than 7.5%. The accuracy determined at these levels was within +/-4.2% in terms of relative error. The method was applied to a pilot bioequivalence study of 500 mg griseofulvin tablet in six healthy human subjects under fed condition.  相似文献   

9.
A rapid, sensitive and selective liquid chromatography-mass spectrometry (LC-MS) method was developed for the simultaneous assay of dextromethorphan and its metabolites in tissue culture medium and its intestinal metabolism studied with the rat everted gut sac model. The method was validated in the concentration range of 0.1-2.5 microM (27.1 ng/mL-0.677 microg/mL) for dextromethorphan and 0.005-0.5 microM for dextrorphan and 3-methoxymorphinan (1.28 ng/mL-0.128 microg/mL) and 3-hydroxymorphinan (1.22 ng/mL-0.122 microg/mL). The limits of quantification (LOQ) were 0.0025 microM (12.5 fmoles, 3.4 pg, 5 microL injected) for dextromethorphan; 0.0025 microM for dextrorphan, 3-methoxymorphinan (24.9 fmoles, 6.4 pg injected), and 3-hydroxymorphinan (25.1 fmoles, 6.1 pg injected) with 10 microL injected. The detection of dextrorphan and 3-methoxymorphinan showed that both the P450 isoforms CYP3A and 2D were active in the intestinal mucosa and metabolised dextromethorphan during its passage across the mucosa.  相似文献   

10.
A 96-well protein precipitation, liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and fully validated for the determination of fudosteine in human plasma. After protein precipitation of the plasma samples (50 microL) by the methanol (150 microL) containing the internal standard (IS), erdosteine, the 96-well plate was vortexed for 5 min and centrifuged for 15 min. The 100 microL supernatant and 100 microL mobile phase were added to another plate and mixed and then the mixture was directly injected into the LC-MS/MS system in the negative ionization mode. The separation was performed on a XB-CN column for 3.0 min per sample using an eluent of methanol-water (60:40, v/v) containing 0.005% formic acid. Multiple reaction monitoring (MRM) using the precursor-product ion transitions m/z 178-->91 and m/z 284-->91 was performed to quantify fudosteine and erdosteine, respectively. The method was sensitive with a lower limit of quantification (LLOQ) of 0.02 microg mL(-1), with good linearity (r>0.999) over the linear range of 0.02-10 microg mL(-1). The within- and between-run precision was less than 5.5% and accuracy ranged from 94.2 to 106.7% for quality control (QC) samples at three concentrations of 0.05, 1 and 8 microg mL(-1). The method was employed in the clinical pharmacokinetic study of fudosteine formulation product after oral administration to healthy volunteers.  相似文献   

11.
A fast, sensitive and specific LC-MS/MS bioanalytical method for the determination of unchanged clopidogrel in human plasma has been developed and validated over the range of 10-12,000 pg mL(-1) (r2 0.9993) by the Contract Research group at HFL. Samples (0.3 mL) were buffered (pH 6.8), extracted using diethyl ether and 10 microL of the sample extract was injected onto the LC-MS/MS system. Analysis was performed using a C8 column (temperature controlled to 50 degrees C) by gradient elution at a flow rate of 0.9 mL min(-1) over a 3 min run time. Retention times of 1.61 and 1.59 min were observed for clopidogrel and 2H3-clopidogrel (I.S.), respectively. Detection was achieved using a Sciex API 4000, triple quadrupole mass spectrometer, in positive TurboIonspray (electrospray) ionisation mode. Ion transitions were monitored using MRM (multiple reaction monitoring) for clopidogrel (m/z 322-212) and for 2H3-clopidogrel (m/z 327-217). This validated method was used to support a pharmacokinetic study in healthy volunteers.  相似文献   

12.
A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of dutasteride (I), a potent and the first specific dual inhibitor of 5alpha-reductase, in human plasma. The analyte and internal standard (finasteride (II)) were extracted by liquid-liquid extraction with diethyl ether/dichloromethane (70/30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on a reverse phase Xterra MS C18 column with a mobile phase of 10 mM ammonium formate/acetonitrile (15/85, v/v, pH adjusted to 3.0 with formic acid). The protonated analyte was quantitated in positive ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 529.5 --> 461.5 and m/z 373.3 --> 317.4 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.1-25.0 ng/mL for dutasteride in human plasma. The lower limit of quantitation was 100 pg/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 1.2 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples/day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

13.
A sensitive liquid chromatography-mass spectrometric (LC/MS) method for the quantification of ginsenoside Rd in dog plasma was developed and validated after solid-phase extraction (SPE).Chromatographic separation was achieved on a reversed-phase Cromosil C(18) column with the mobile phase of acetonitrile-ammonium chloride (500 micromol/L) and step gradient elution resulted in a total run time of about 5.5 min. The analytes were detected by using an electrospray negative ionization mass spectrometry in the selected ion monitoring (SIM) mode. A good linear relationship was obtained in the concentration range studied (0.005-2.500 microg/mL) (r=0.9998). Lower limit of quantification (LLOQ) was 5 ng/mL by using 500 microL plasma sample. Average recoveries ranged from 70.71 to 75.89% in plasma at the concentrations of 0.010, 0.100 and 2.500 microg/mL. Intra- and inter-day relative standard deviations were 8.49-11.71 and 5.71-16.48%, respectively. This method was successfully applied to the pharmacokinetic studies on dogs. The absolute bioavailability of Rd in dogs was 0.26%.  相似文献   

14.
Anabolic androgenic steroids are related to the male sex hormones and are abused in equine sports. In an effort to deter the abuse of anabolic steroids, a sensitive LC-MS/MS method was developed for detection, quantification and confirmation of eight major anabolic steroids (testosterone, normethandrolone, nandrolone, boldenone, methandrostenolone, tetrahydrogestrinone (THG), trenbolone, and stanozolol) in equine plasma. Formation of solvent adduct ions of the analytes was observed under electrospray ionization (ESI) conditions, and desolvation of the solvent adduct ions by source collision-induced decomposition (CID) increased the abundance of the [M+H]+ ions as well as the multiple-reaction monitoring (MRM) signals. ESI (+) and APCI (+) were compared with respect to sensitivity for the analytes and the former provided better sensitivity. The matrix effect on ion suppression or enhancement was evaluated, and was negligible. Confirmation of the analytes was performed using criteria of three ion transitions and LC retention time of each analyte. The limit of detection (LOD) and quantification (LOQ) was 25 pg/mL. The limit of confirmation (LOC) was 25 pg/mL for boldenone; 50 pg/mL for normethandrolone, nandrolone, and methandrostenolone; and 100 pg/mL for testosterone, THG, trenbolone, and stanozolol. The analytes were evaluated for stability and found to be stable in plasma for 24h at room temperature, 13 days at 4 degrees C, and 34 days at -20 and -70 degrees C. The method was successfully applied to analyses of equine plasma samples for pharmacokinetics study. This method is sensitive and useful for detection, quantification and confirmation of these anabolic steroids in equine plasma.  相似文献   

15.
A highly sensitive, selective and evaporation free SPE extraction, ESI-LC-MS/MS method has been developed for estimation of misoprostol free acid in human plasma using misoprostol acid-d(5) as an internal standard (IS). The analyte was separated using isocratic mobile phase on reverse phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective [M-H] anions, m/z 367-249 for misoprostol acid and m/z 372-249 for the IS. The total run time was 5.0 min and the elution of misoprostol acid and misoprostol acid-d(5) (IS) occurred at 3.6 min. The developed method was validated in human plasma with a lower limit of quantification of 2.5 pg/mL. A linear response function was established for the range of concentrations 2.5-1200 pg/mL (r>0.998) for misoprostol acid in human plasma. The intra and inter-day precision values for misoprostol acid met the acceptance as per FDA guidelines. Misoprostol acid was stable in the battery of stability studies viz., bench-top, auto-sampler and freeze/thaw cycles. The developed assay method was applied to an oral pharmacokinetic study in humans.  相似文献   

16.
Imidafenacin (KRP-197/ONO-8025, IM), 4-(2-methyl-1H-imidazol-1-yl)-2,2-diphenylbutanamide, is a new antimuscarinic agent currently under application for the indication of treatment of overactive bladder in Japan. We developed and validated the sensitive and selective bioanalytical methods for the extremely low levels of IM and its metabolite, M-2 (Method 1), M-4 (Method 2) and M-9 (Method 3) in human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS). In each method, plasma sample was extracted by solid phase extraction, separated on a semi-micro high performance liquid chromatography column and detected by tandem mass spectrometer with an atmospheric pressure chemical ionization or ionspray interface. Selected reaction monitoring mode was used for quantification. Each method was found to have acceptable accuracy, precision, stability, selectivity and linearity over the concentration range of 10-500 pg/mL for IM and M-2, 10-1000 pg/mL for M-4 and 50-5000 pg/mL for M-9. Using these analytical methods, concentration profiles of IM and its metabolites in human plasma were successfully determined even in the low pg/mL levels after oral administration of IM at the therapeutic dosage of 0.1 mg.  相似文献   

17.
A sensitive and specific high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS-MS) method has been developed and validated for the determination of palmatine in canine plasma. Palmatine and jatrorrhizine (internal standard, I.S.) were extracted from plasma samples by solid-phase extraction (SPE) using Oasis HLB cartridges. The chromatographic separation was performed on a Waters XTerra MS C(18) reversed-phase column at 30 degrees C. The gradient mobile phase, delivered at 0.25 mL/min, was composed of a mixture of acetonitrile -0.1% (v/v) acetic acid aqueous solution adjusted to pH 2.8 with triethylamine. Positive electrospray ionization was utilized as the ionization source. Palmatine and the internal standard (I.S.) were determined using multiple reaction monitoring (MRM) of precursor-->product ion transitions at m/z 352-->336 and m/z 338-->322, respectively. The lower limit of quantification (LLOQ) was 0.1 ng/mL using 100 microL plasma samples and the linear calibration range was from 0.1 to 500 ng/mL. The inter-day and intra-day RSDs were lower than 9.9% and the recoveries of palmatine ranged from 87.3 to 100.9%. The mean extraction recoveries of palmatine and the I.S. were 99.2 and 96.8%, respectively. The method has been successfully applied to the pharmacokinetic studies of palmatine in beagle dogs after oral administration and intramuscular injection of palmatine.  相似文献   

18.
Dihydroartemisinin (DHA) is a sesquiterpene used in the world as an antimalarial. To evaluate the pharmacokinetics of dihydroartemisinin in rats, a sensitive and specific liquid chromatography/tandem mass spectrometric (LC-MS/MS) method was developed and validated for the quantitation of dihydroartemisinin in rat plasma. For detection, a Sciex API 4000 LC-MS/MS with a TurboIonSpray ionization (ESI) inlet in the positive ion-multiple reaction monitoring (MRM) mode was used. The plasma samples were pre-treated by a simple liquid-liquid extraction with diethyl ether. The statistical evaluation for this method reveals excellent linearity, accuracy and precision for the range of concentrations 0.2-100.0 ng/mL. The method had a lower limit of quantification (LLOQ) of 0.2 ng/mL for beta-dihydroartemisinin in 100 microL of plasma. The method was successfully applied to the characterization of the pharmacokinetic profile of beta-dihydroartemisinin in rats after oral administration.  相似文献   

19.
A sensitive method was developed and validated for the measurement of 17-(allylamino)-17-demethoxygeldanamycin (17AAG) and its active metabolite 17-amino-17-demethoxygeldanamycin (17AG) in human plasma using 17-(dimethylaminoethylamino)-17-demethoxygeldanamycin (17DMAG) as an internal standard. After the addition of internal standard, 200 microL of plasma was extracted using ice cold acetonitrile followed by analysis on a Thermo Finnigan triple-quadruple mass spectrometer coupled to an Agilent 1100 HPLC system. Chromatography was carried out on a 50 mm x 2.1 mm Agilent Zorbax SB-phenyl 5 microm column coupled to a 3mm Varian metaguard diphenyl pre-column using glacial acetic acid 0.1% and a gradient of acetonitrile and water at a flow rate of 500 microL/min. Atmospheric pressure chemical ionization and detection of 17AAG, 17AG and 17DMAG were accomplished using selected reaction monitoring of m/z 584.3>541.3, 544.2>501.2, and 615.3>572.3, respectively in negative ion mode. Retention times for 17AAG, 17AG, and 17DMAG were 4.1, 3.5, and 2.9 min, respectively, with a total run time of 7 min. The assay was linear over the range 0.5-3000 ng/mL for 17AAG and 17AG. Replicate sample analysis indicated within- and between-run accuracy and precision within 15%. The recovery of 17AAG and 17AG from 200 microL of plasma containing 1, 25, 300, and 2500 ng/mL was 93% or greater. This high-performance liquid chromatographic tandem mass spectroscopy (HPLC/MS/MS) method is superior to previous methods. It is the first analytical method reported to date for the quantitation of both 17AAG and its metabolite 17AG and can reliably quantitate concentrations of both compounds as low as 0.5 ng/mL.  相似文献   

20.
A simple, sensitive and rapid liquid chromatography/tandem mass spectrometric (LC-MS/MS) method was developed and validated for quantification of chloroquine, an antimalarial drug, in plasma using its structural analogue, piperazine bis chloroquinoline as internal standard (IS). The method is based on simple protein precipitation with methanol followed by a rapid isocratic elution with 10 mM ammonium acetate buffer/methanol (25/75, v/v, pH 4.6) on Chromolith SpeedROD RP-18e reversed phase chromatographic column and subsequent analysis by mass spectrometry in the multiple reaction monitoring mode (MRM). The precursor to product ion transitions of m/z 320.3-->247.2 and m/z 409.1-->205.2 were used to measure the analyte and the IS, respectively. The assay exhibited a linear dynamic range of 2.0-489.1 ng/mL for chloroquine in dog plasma. The limit of detection (LOD) and lower limit of quantification (LLOQ) were 0.4 and 2.0 ng/mL, respectively in 0.05 mL plasma. Acceptable precision and accuracy were obtained for concentrations over the standard curve range of 2.0-489.1 ng/mL. A run time of 2.0 min for a sample made it possible to achieve a throughput of more than 400 plasma samples analyzed per day. The validated method was successfully used to analyze samples of dog plasma during non-clinical study of chloroquine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号