1.
Xian Y  Hu Y  Liu F  Xian Y  Wang H  Jin L 《Biosensors & bioelectronics》2006,21(10):1996-2000
In this paper, we report a novel glucose biosensor based on composite of Au nanoparticles (NPs)-conductive polyaniline (PANI) nanofibers. Immobilized with glucose oxidase (GOx) and Nafion on the surface of nanocomposite, a sensitive and selective biosensor for glucose was successfully developed by electrochemical oxidation of H2O2. The glucose biosensor shows a linear calibration curve over the range from 1.0x10(-6) to 8.0x10(-4) mol/L, with a slope and detection limit (S/N=3) of 2.3 mA/M and 5.0x10(-7) M, respectively. In addition, the glucose biosensor system indicates excellent reproducibility (less than 5% R.S.D.) and good operational stability (over 2 weeks).  相似文献   

2.
An uric acid biosensor fabricated from a uricase-immobilized eggshell membrane and an oxygen electrode was presented. The detection schemes involve the enzymatic reactions of the uricase leading to the depletion of dissolved oxygen level upon exposure to uric acid solution. The decrease in oxygen level was monitored and related to the uric acid concentration. The scanning electron micrographs show the microstructure of the eggshell membrane within which the uricase is successfully immobilized. The effects of enzyme loading, pH, temperature, and phosphate buffer concentration on the response of the biosensor were investigated in detail. The uric acid biosensor has a linear response range of 4.0-640 microM with a detection limit of 2.0 microM (S/N=3). The response time was less than 100 s. The biosensor exhibited good repeatable response to a 0.10mM uric acid solution with a relative standard deviation of 3.1% (n=7). The reproducibility of fabrication of the biosensors using four different membranes was good with a R.S.D. of 3.2%. The biosensor showed extremely good stability with a shelf-life of at least 3 months. Some common potential interferents in samples such as glucose, urea, ascorbic acid, lactic acid, glycine, DL-alpha-alanine, DL-cysteine, KCl, NaCl, CaCl2, MgSO4, and NH4Cl showed no interferences on the response of the uric acid biosensor. The biosensor was successfully applied to determine the uric acid level in some human serum and urine samples, and the results agreed well with those obtained by a commercial colorimetric assay kit.  相似文献   

3.
Zou Y  Sun LX  Xu F 《Biosensors & bioelectronics》2007,22(11):2669-2674
In this work, a novel route for fabrication polyaniline (PANI)-Prussian Blue (PB) hybrid composites is proposed by the spontaneous redox reaction in the FeCl(3)-K(3)[Fe(CN)(6)] and the aniline solution. With the introduction of multi-walled carbon nanotubes (MWNTs), the PANI-PB/MWNTs system shows synergy between the PANI-PB and MWNTs which amplified the H(2)O(2) sensitivity greatly. A linear range from 8 x1 0(-8) to 1 x 10(-5)M and a high sensitivity 508.1 8 microA microM cm(2) for H(2)O(2) detection are obtained. The composites also show good stability in neutral solution. A glucose biosensor was further constructed by immobilizing glucose oxidase (GOD) with Nafion and glutaraldehyde on the electrode surface. The performance factors influencing the resulted biosensor were studied in detail. The biosensor exhibits excellent response performance to glucose with the linear range from 1 to 11 mM and a detection limit of 0.01 mM. Furthermore, the biosensor shows rapid response, high sensitivity, good reproducibility, long-term stability and freedom of interference from other co-existing electroactive species.  相似文献   

4.
An amperometric glucose biosensor based on an n-alkylamine-stabilized palladium nanoparticles (PdNPs)-glucose oxidase (GOx) modified glassy carbon (GC) electrode has been successfully fabricated. PdNPs were initially synthesized by a biphase mixture of water and toluene method using n-alkylamines (dodecylamine, C??-NH? and octadecylamine, C??-NH?) as stabilizing ligands. The performance of the PdNPs-GOx/GC biosensor was studied by cyclic voltammetry. The optimum working potential for amperometric measurement of glucose in pH 7.0 phosphate buffer solution is -0.02 V (vs. Ag/AgCl). The analytical performance of the biosensor prepared from C??-PdNPs-GOx is better than that of C??-PdNPs-GOx. The C??-PdNPs-GOx/GC biosensor exhibits a fast response time of ca. 3s, a detection limit of 3.0 μM (S/N=3) and a linear range of 3.0 μM-8.0 mM. The linear dependence of current density with glucose concentration is 70.8 μA cm?2 mM?1. The biosensor shows good stability, repeatability and reproducibility. It has been successfully applied to determine the glucose content in human blood serum samples.  相似文献   

5.
In this study, a new chemiluminescence (CL) flow-through biosensor for glucose was developed by immobilizing glucose oxidase (GOD) and horseradish peroxidase (HRP) on the eggshell membrane with glutaraldehyde as a cross-linker. The CL detection involved enzymatic oxidation of glucose to D-gluconic acid and hydrogen peroxide (H2O2) and then H2O2 oxidizing luminol to produce CL emission in the presence of HRP. The immobilization condition (e.g., immobilization time, GOD/HRP ratio, glutaraldehyde concentration) was studied in detail. It showed good storage stability at 4 degrees C over a 5-month period. The proposed biosensor exhibited short response time, high sensitivity, easy operation, and simple sensor assembly, and the proposed biosensor was successfully applied to the determination of glucose in human serum.  相似文献   

6.
A method is described for construction of an amperometric biosensor for detection of phenolic compounds based on covalent immobilization of laccase (Lac) onto manganese dioxide nanoparticles (MnO(2)NPs) decorated carboxylated multiwalled carbon nanotubes (cMWCNTs)/PANI composite electrodeposited onto a gold (Au) electrode through N-ethyl-N'-(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxy succinimide (NHS) chemistry. The modified electrode was characterized by scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The biosensor showed optimum response at pH 5.5 (0.1M sodium acetate buffer) and 35°C, when operated at 0.3 V vs. Ag/AgCl. Linear range, response time, detection limit were 0.1-10 μM (lower concentration range) and 10-500 μM (higher concentration range), 4s and 0.04 μM, respectively. Biosensor measured total phenolic content in tea leaves extract. The enzyme electrode was used 150 times over a period of 5 months.  相似文献   

7.
Yu Y  Liu X  Jiang D  Sun Q  Zhou T  Zhu M  Jin L  Shi G 《Biosensors & bioelectronics》2011,26(7):3227-3232
A new type of hydroxyl functionalized room temperature ionic liquid (RTIL), [C(3)(OH)(2)mim][BF(4)], was synthesized herein and a novel H(2)O(2) biosensor is fabricated with [C(3)(OH)(2)mim][BF(4)] as the substrate and electrodepositing bimetallic Au/Pt nanoparticles (NPs) onto the [C(3)(OH)(2)mim][BF(4)] film. The functionalization of RTIL with hydroxyl groups provided an appropriate environment for the preparation of more uniform and smaller Au/Pt NPs with the diameter of 2.5 nm±0.2 nm. Immobilized with glutamate oxidase (GlutaOx), the resulting GlutaOx-[C(3)(OH)(2)mim][BF(4)]-Au/Pt-Nafion biosensor displayed excellent electrocatalytic response to glutamate at a potential of -200 mV. An effective on-line microdialysis system, which was powered by a microdialysis pump, was set up and used for the detection of glutamate successively in the striatum of rats. The glutamate biosensor in on-line microdialysis system showed good linear range from 0.5 μM to 20.0 μM with the detection limit of 0.17 μM (S/N=3). The basal level of glutamate in the striatum of anaesthetic rats was calculated to be 3.01±0.67 μM (n=3). The application of the GlutaOx-[C(3)(OH)(2)mim][BF(4)]-Au/Pt-Nafion electrode is further demonstrated for in vivo sensing of the variation of glutamate level in the striatum when rats received intraperitoneal (i.p.) injection of 100 mM KCl and brain electrical stimulation of the subthalamic nucleus area (STN). Both of the two kinds of stimulation resulted in an increase in the extracellular concentration of glutamate. This method has proved to be sensitive and reproducible, which enables its promising application in physiology and pathology.  相似文献   

8.
Shan D  He Y  Wang S  Xue H  Zheng H 《Analytical biochemistry》2006,356(2):215-221
A novel glucose biosensor was constructed by electrochemical entrapment of glucose oxidase (GOD) into porous poly(acrylonitrile-co-acrylic acid), which was synthesized via radical polymerization of acrylonitrile and acrylic acid. The obtained biosensor showed a better stability and higher sensitivity than the biosensor prepared by simple physical adsorption. Effects of some experimental variables such as immobilization time, enzyme concentration, pH, applied potential, and temperature on the amperometric response of the sensor were investigated. The biosensor exhibited a rapid response to glucose (< 30s) with a linear range of 5 x 10(-6) to 3 x 10(-3)M and a sensitivity of 6.82 mAM(-1)cm(-2). The apparent Michaelis-Menten constant (K(M)(app)) was 7.3mM.  相似文献   

9.
A sensitive and selective amperometric glucose biosensor based on platinum microparticles dispersed in nano-fibrous polyaniline (PANI) was investigated. Poly (m-phenylenediamine) (PMPD), which was employed as an anti-interferent barrier and a protective layer to platinum microparticles, was deposited onto platinum-modified PANI in the presence of glucose oxidase. The morphology of PANI, Pt/PANI and PMPD-GOD/Pt/PANI were investigated by scanning electron microscopy. The results show that PANI has a nano-fibrous morphology. The enzyme electrode exhibits excellent response performance to glucose with linear range from 2 x 10(-6) to 12 x 10(-3) M and fast response time within 7s. Due to the selective permeability of PMPD, the enzyme electrode also shows good anti-interference to uric acid and ascorbic acid. The Michaelis-Menten constant km and the maximum current density imax of the enzyme electrode were 9.34 x 10(-3) M and 917.43 microA cm(-2), respectively. Furthermore, this glucose biosensor also has good stability and reproducibility.  相似文献   

10.
We have developed a stable and selective ATP biosensor for long-term in vitro tissue monitoring. The electrode was fabricated by entrapping glucose oxidase (GOx) and hexokinase (HEX) in a poly-phenol film on a Pt microelectrode. The biosensor was stable to a fixed concentration of glucose for over 20 min and had a limit of detection of 9.9 ± 3.2 nM, with a sensitivity of 45.8 ± 1.22 pA μM(-1). Most significantly of all, the response on the ATP biosensor did not alter in the presence of 1mM ascorbic acid, 5 μM dopamine, 5 μM serotonin, 5 μM ADP and 5 μM AMP. The ATP biosensor was also shown to have excellent stability over 7 days, and showed only a 23.92 ± 3.55% loss in sensitivity. The ATP biosensor was utilised for the in vitro detection of ATP from gastrointestinal tissue. The ATP biosensor response was stable for 5h during in vitro recordings from ileum tissue. ATP release was shown to be greater from the mucosal surface in the ileum compared to the colon.  相似文献   

11.
Amperometric glucose biosensors utilizing commercially available FAD-dependent glucose dehydrogenases from two strains of Aspergillus species are described. Enzymes were immobilized on nanocomposite electrode consisting of multi-walled carbon nanotubes by entrapment between chitosan layers. Unlike the common glucose oxidase based biosensor, the presented biosensors appeared to be O(2)-independent. The optimal amount of enzymes, working potential and pH value of working media of the glucose biosensors were determined. The biosensor utilizing enzyme isolated from Aspergillus sp. showed linearity over the range from 50 to 960 μM and from 70 to 620 μM for enzyme from Aspergillus oryzae. The detection limits were 4.45 μM and 4.15 μM, respectively. The time of response was found to be 60 s. The biosensors showed excellent operational stability - no loss of sensitivity after 100 consecutive measurements and after the storage for 4 weeks at 4 °C in phosphate buffer solution. When biosensors were held in a dessicator at room temperature without use, they kept the same response ability at least after 6 months. Finally, the results obtained from measurements of beverages and wine samples were compared with those obtained with the enzymatic-spectrophotometric and standard HPLC methods, respectively. Good correlation between results in case of analysis of real samples and good analytical performance of presented glucose biosensor allows to use presented concept for mass production and commercial use.  相似文献   

12.
A highly efficient enzyme-based screen printed electrode (SPE) was obtained by using covalent attachment between 1-pyrenebutanoic acid, succinimidyl ester (PASE) adsorbing on the graphene oxide (GO) sheets and amines of tyrosinase-protected gold nanoparticles (Tyr-Au). Herein, the bi-functional molecule PASE was assembled onto GO sheets. Subsequently, the Tyr-Au was immobilized on the PASE-GO sheets forming a biocompatible nanocomposite, which was further coated onto the working electrode surface of the SPE. The characterization of obtained nanocomposite and modified SPE surface was investigated by atomic force microscopy (AFM), transmission electron microscopy (TEM) and scanning electron microscopy (SEM). Attributing to the synergistic effect of GO-Au integration and the good biocompatibility of the hybrid-material, the fabricated disposable biosensor (Tyr-Au/PASE-GO/SPE) exhibited a rapid amperometric response (less than 6s) with a high sensitivity and good storage stability for monitoring catechol. This method shows a good linearity in the range from 8.3×10(-8) to 2.3×10(-5) M for catechol with a squared correlation coefficient of 0.9980, a quantitation limit of 8.2×10(-8) M (S/N=10) and a detection limit of 2.4×10(-8) M (S/N=3). The Michaelis-Menten constant was measured to be 0.027 mM. This disposable tyrosinase biosensor could offer a great potential for rapid, cost-effective and on-field analysis of phenolic compounds.  相似文献   

13.
A nonenzymatic electrochemical biosensor was developed for the detection of glucose based on an electrode modified with palladium nanoparticles (PdNPs)-functioned graphene (nafion-graphene). The palladium nanoparticle-graphene nanohybrids were synthesized using an in situ reduction process. Nafion-graphene was first assembled onto an electrode to chemically adsorb Pd(2+). And Pd(2+) was subsequently reduced by hydrazine hydrate to form PdNPs in situ. Such a PdNPs-graphene nanohybrids-based electrode shows a very high electrochemical activity for electrocatalytic oxidation of glucose in alkaline medium. The proposed biosensor can be applied to the quantification of glucose with a wide linear range covering from 10 μM to 5mM (R=0.998) with a low detection limit of 1 μM. The experiment results also showed that the sensor exhibits good reproducibility and long-term stability, as well as high selectivity with no interference from other potential competing species.  相似文献   

14.
A nano-molar sensitive disposable biosensor for determination of dopamine.   总被引:1,自引:0,他引:1  
The studies on a nano-molar sensitive disposable biosensor based on the screen-printing basal electrode and the supramolecular assembly of dual mediators, tetramethylbenzidine and ferrocene, by beta-cyclodextrin inclusion complexation have been reported in this paper. This biosensor shows the high quality of analytical performance because of the complexation and the microenvironment in the supramolecular structure. The extracted protein of mushroom, which contains abundant polyphenol oxidase, was immobilized in the membrane of cross-linked cyclodextrin film. This biosensor responds to dopamine with high selectivity and sensitivity. Its response range on the concentration of dopamine is from 1.0 x 10(-9) to 1.0 x 10(-6) M with the detection limit as low as 5.0 x 10(-10) M. The response time reaching to 90% of its steady value is less than 60 s. The biosensor can keep its activity for at least 15 days.  相似文献   

15.
Water safety is one of the most pervasive problems afflicting people throughout the world. Microcystin, a hepatotoxin produced by cyanobacteria, poses a growing and serious threat of water safety. According to World Health Organization (WHO), the limit of content of microcystin-LR (MC-LR) in drinking water is as low as 1μg/L; it is thus necessary to explore a sensitive method for the trace detection of microcystins (MCs). Based on the observation of gold nanoparticles (Au NPs) induced graphene oxide (GO) fluorescence quenching, a reliable biosensor was developed here for microcystins detection. MCs could be attached on Au NPs through the interaction with single strand-DNA (ss-DNA) modified on Au NPs, which formed Au-DNA-MCs complexes. These MCs in the complexes could be immunologically recognized by the antibodies adsorbed on GO sheets, as a result, Au NPs were close enough to quench the photoluminescence of GO by the fluorescence resonance energy transfer (FRET). The fluorescence intensity decreased with the increase of MCs as more Au NPs linked onto GO surface. The limit of detection was 0.5 and 0.3μg/L for microcystin-LR and microcystin-RR (MC-RR), respectively, which satisfies the strictest standard of WHO. Well defined results were also obtained in natural lake water and the specificity experiment. The antibody used here could recognize Adda group, the conservative part of MCs, which allowed the biosensor to detect both single toxin and the total content of MCs existing in the water sample.  相似文献   

16.
Chen C  Wang L  Tan Y  Qin C  Xie F  Fu Y  Xie Q  Chen J  Yao S 《Biosensors & bioelectronics》2011,26(5):2311-2316
Rapid oxidation of dopamine (DA) or L-noradrenaline (NA) by K(3)Fe(CN)(6) yields poly(DA) (PDA(C)) or poly(NA) (PNA(C)) with glucose oxidase (GOx) effectively entrapped, and such an enzyme-entrapped catecholamine polymer is cast on an Au electrode followed by chitosan (CS) strengthening for biosensing and fabrication of a biofuel cell (BFC). The optimized glucose biosensor of CS/PDA(C)-GOx/Au displays an extremely high sensitivity up to 135 μA mM(-1) cm(-2), a very low limit of detection of 0.07 μM, a response time of <3 s, good suppression of interferents, striking thermostability (lifetime of 3 weeks at 60°C and over 2 months at 30°C), and high resistance to urea denaturation. The biosensor also works well in the second generation biosensing mode with p-benzoquinone (BQ) or ferrocene monocarboxylic acid (Fc) as an artificial mediator, with greatly broadened linear detection ranges (2.0 μM-48.0 mM for BQ and 2.0 μM-16.0 mM for Fc) and up to mA cm(-2)-scale glucose-saturated current density. The good permeability of artificial mediators across the enzyme film enables the quantification of the surface concentration of immobilized GOx on the basis of a reported kinetic model, and UV-Vis spectrophotometry is used to measure the enzymatic activity, revealing high enzymatic activity/load at CS/PDA(C)-GOx/Au. A BFC is also successfully fabricated with a bioanode of CS/PDA(C)-GOx/Au in phosphate buffer solution containing 100 mM glucose and 4.0 mM BQ and a carbon cathode in Nafion-membrane-isolated acidic KMnO(4), and its maximum power density of 1.62 mW cm(-2) is superior to those of most BFC hitherto reported.  相似文献   

17.
One-step construction of Pt nanoparticles-chitosan composite film (PtNPs-CS) was firstly proposed as a novel immobilization matrix for the enzymes to fabricate glucose biosensor. This novel interface embedded in situ PtNPs in CS hydrogel was developed by one-step electrochemical deposition in solution containing CS and chloroplatinic acid (H(2)PtCl(6)). Several techniques, including scanning electron microscopy (SEM), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and chronoamperometry were employed to characterize the assembly process and performance of the biosensor. Under the optimized experimental conditions, the resulting biosensor exhibited excellent linear behavior in the concentration range from 1.2 μM to 4.0 mM for the quantitative analysis of glucose with a limit of detection of 0.4 μM at a signal-to-noise ratio of 3. The apparent Michaelis-Menten constant (K(M)(app)) was evaluated to be 2.4 mM, showing good affinity. The proposed biosensor offered good amperometric responses to glucose due to the nanostructured sensing film provided plenty of active sites for the immobilization of glucose oxidase (GOD).  相似文献   

18.
A novel amperometric glucose biosensor was developed using the bio-inspired peptide nanotube (PNT) as an encapsulation template for enzymes. Horseradish peroxidase (HRP) was encapsulated by the PNT and glucose oxidase (GO(x)) was co-immobilized with the PNT on a gold nanoparticle (AuNP)-modified electrode. A binary SAM of 3-mercaptopropionic acid (MPA) and 1-tetradecanethiol (TDT) was formed on the surface of the electrode to immobilize the PNT and GO(x). The resulting electrode appeared to provide the enzymes with a biocompatible nanoenvironment as it sustained the enhanced enzyme activity for an extended time and promoted possible direct electron transfer through the PNT to the electrode. Performance of the biosensor was evaluated in terms of its detection limit, sensitivity, pH, response time, selectivity, reproducibility, and stability in a lab setting. In addition the sensor was tested for real samples. The composite of AuNP-SAM-PNT/HRP-GO(x) to fabricate a sensor electrode in this study exhibited a linear response with glucose in the concentration range of 0.5-2.4mM with a R(2)-value of 0.994. A maximum sensitivity of 0.3mAM(-1)and reproducibility (RSD) of 1.95% were demonstrated. The PNT-encapsulated enzyme showed its retention of >85% of the initial current response after one month of storage.  相似文献   

19.
For the first time glucose oxidase (GOx) was successfully co-deposited on nickel-oxide (NiO) nanoparticles at a glassy carbon electrode. In this paper we present a simple fabrication method of biosensor which can be easily operated without using any specific reagents. Cyclic voltammetry was used for electrodeposition of NiO nanoparticle and GOx immobilization. The direct electron transfer of immobilized GOx displays a pair of well defined and nearly reversible redox peaks with a formal potential (E(0')) of -0.420 V in pH 7 phosphate buffer solution and the response shows a surface controlled electrode process. The surface coverage and heterogeneous electron transfer rate constant (k(s)) of GOx immobilized on NiO film glassy carbon electrode are 9.45 x 10(-13)mol cm(-2) and 25.2+/-0.5s(-1), indicating the high enzyme loading ability of the NiO nanoparticles and great facilitation of the electron transfer between GOx and NiO nanoparticles. The biosensor shows excellent electrocatalytical response to the oxidation of glucose when ferrocenmethanol was used as an artificial redox mediator. Furthermore, the apparent Michaelis-Menten constant 2.7 mM, of GOx on the nickel oxide nanoparticles exhibits excellent bioelectrocatalytic activity of immobilized enzyme toward glucose oxidation. In addition, this glucose biosensor shows fast amperometric response (3s) with the sensitivity of 446.2nA/mM, detection limit of 24 microM and wide concentration range of 30 microM to 5mM. This biosensor also exhibits good stability, reproducibility and long life time.  相似文献   

20.
In situ growth of gold nanoparticles (Au NPs) was performed in an alginate gel matrix co‐encapsulating Au NP seeds and glucose oxidase (GOx) for the development of a glucose‐sensing platform. We observed a simultaneous growth of Au NPs in the alginate matrix through the reduction of AuCl by H2O2 on Au NP seeds. The detection of the glucose level was carried out successfully via the coupling of Au NP enlargement with the oxidation of glucose catalyzed by the immobilized GOx. The enlargement of Au NPs in the alginate matrix exhibited only a red‐shift in absorbance maxima, while the generation of small Au NPs in a free solution caused a blue‐shift in higher glucose concentrations. This study shows that the co‐encapsulation of metal NPs and bioreceptor in a gel matrix may provide a simple route for the fabrication of an optical biosensor. Biotechnol. Bioeng. 2010;105: 210–214. © 2009 Wiley Periodicals, Inc.  相似文献   