首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 234 毫秒
1.
A selective semi-automated solid-phase extraction (SPE) of the non-steroidal anti-inflammatory drugs diclofenac sodium, indomethacin and phenylbutazone from urine prior to high-performance liquid chromatography was investigated. The drugs were recovered from urine buffered at pH 5.0 using C18 Bond-Elut cartridges as solid sorbent material and mixtures of methanol–aqueous buffer or acetonitrile–aqueous buffer as washing and elution solvents. The extracts were chromatographed on a reversed-phase ODS column using 10 mM acetate buffer (pH 4.0)–acetonitrile (58:42, v/v) as the mobile phase, and the effluent from the column was monitored at 210 nm with ultraviolet detection. Absolute recoveries of the anti-inflammatory drugs within the range 0.02–1.0 μg/ml were about 85% for diclofenac and indomethacin, and 50% for phenylbutazone without any interference from endogenous compounds of the urine. The within-day and between-day repeatabilities were in all cases less than 5% and 10%, respectively. Limits of detection were 0.007 μg/ml for diclofenac sodium and indomethacin and 0.035 μg/ml for phenylbutazone, whereas limits of quantitation were 0.02 μg/ml for diclofenac and indomethacin and 0.1 μg/ml for phenylbutazone.  相似文献   

2.
The determination of 3-hydroxyquinine in urine and plasma samples is described. Extraction was performed using a mixture of toluene–butanol (75:25, v/v), followed by back-extraction into the mobile phase, which consisted of 0.1 M phosphate buffer, acetonitrile, tetrahydrofuran and triethylamine. A reversed-phase liquid chromatography system with fluorescence detection and a CT-sil C18 column were used. The within-assay coefficient of variation of the method was 2% at the higher concentration values in plasma, 2.95 μM, 4% at 227 nM and 9% at the lower limit of quantitation, 4.5 nM. In urine, the coefficient of variation was 11% at the lower concentration, 227 nM and was 3% at 56.8 μM. The between-assay coefficient of variation was 4% at the low concentration (5.1 nM) in plasma, 2% at 276.8 nM and 3% at 1.97 μM. In urine, the between assay coefficient of variation was 4% at 204.6 nM, 3% at 5.12 μM and 2% at 56.8 μM.  相似文献   

3.
A selective HPLC method is described for the determination of cefpodoxime levels in plasma and sinus mucosa. Sample preparation included solid-phase extraction with a C8 cartridge. Cefpodoxime and cefaclor (internal standard) were eluted with methanol and analyzed on an optimised system consisting of a C18 stationary phase and a ternary mobile phase (0.05 M acetate buffer pH 3.8—methanol—acetonitrile, 87:10:3, v/v) monitored at 235 nm. Linearity and both between- and within-day reproducibility were assessed for plasma and sinus mucosa samples. Inter-assay coefficients of variation were lower than 13.6% (n = 10) for plasma (0.2 μg/ml) and lower than 12.4% (n = 5) for sinus mucosa (0.25 μg/g). The quantification limit was 0.05 μg/ml for plasma and 0.13 μg/g for tissue. The method was used to study the diffusion of cefpodoxime in sinus mucosa.  相似文献   

4.
5.
A 0.5-ml aliquot of a serum sample, after the addition of a 100-μl aliquot of a 5 μg/ml solution of dibucaine as the internal standard, is vortex-mixed with 0.5 ml of acetonitrile and centrifuged. The supernatant is applied to a 1-ml BondElut C18 silica extraction column conditioned with subsequent washings with 1 M HCl, methanol and water. After passing the sample at a slow rate, the column is washed twice with water and once with acetonitrile. The desired compounds are then eluted with a 0.25-ml aliquot of 35% perchloric acid—methanol (1:40, v/v). A 7-μl aliquot of the eluate is injected onto a 150 × 4.6 mm I.D. column packed with 5-μm C8 silica particles and eluted at ambient temperature with a mobile phase of 10 mM phosphate buffer-acetonitrile (2:1, v/v) (pH 3.2). The peaks are detected with a fluorescence detector (excitation at 295 nm, emission at 365 nm). The resulting chromatogram is clean with no extraneous peaks. Paroxetine and dibucaine give sharp peaks which are well separated from each other and from the solvent peaks. The extraction recovery of the drug and the internal standard is in the range of 90% which allows a highly sensitive determination of paroxetine.  相似文献   

6.
A bioanalytical method for the determination of atovaquone in 100 μl blood-spots by solid-phase extraction and high-performance liquid chromatography has been developed and validated. Atovaquone was extracted from the sampling paper in 0.2 M phosphoric acid and a structurally similar internal standard was added with acetonitrile before being loaded onto a C8 end-capped solid-phase extraction column. Atovaquone and internal standard were analysed by high-performance liquid chromatography on a C18 J’Sphere ODS-M80 (150×4.0 mm) column with mobile phase acetonitrile–phosphate buffer, 0.01 M, pH 7.0 (65:35, v/v) and UV detection at 277 nm. The intra-assay precision was 2.7% at 12.00 μM and 13.5% at 1.00 μM. The inter-assay precision was 3.3% at 12.00 μM and 15.6% at 1.00 μM. The lower limit of quantification was 1.00 μM. The limit of detection was 0.50 μM.  相似文献   

7.
A simple procedure for the simultaneous determination of modafinil, its acid and sulfone metabolites in plasma is described. The assay involved an extraction of the drug, metabolites and internal standard from plasma with a solid-phase extraction using C18 cartridges. These compounds were eluted by methanol. The extract was evaporated to dryness at 40°C under a gentle stream of nitrogen. The residue was redissolved in 250 μl of mobile-phase and a 30 μl aliquot was injected via an automatic sampler into the liquid chromatograph and eluted with the mobile-phase (26%, v/v acetonitrile in 0.05 M orthophosphoric acid buffer adjusted to pH 2.6) at a flow-rate of 1.1 ml/min on a C8 Symmetry cartridge column (5 μm, 150 mm×3.9 mm, Waters) at 25°C. The eluate was detected at 225 nm. Intra-day coefficients of variation ranged from 1.0 to 2.9% and inter-day coefficients from 0.9 to 6.1%. The limits of detection and quantitation of the assay were 0.01 μg/ml and 0.10 μg/ml respectively.  相似文献   

8.
High-performance liquid chromatographic methods were developed for the determination of azosemide and its metabolite, M1, in human plasma and urine and rabbit blood and tissue homogenates. The methods involved deproteinization of the biological samples: 2.5 volumes of acetonitrile were used for the determination of azosemide and 1 volume of saturated Ba(OH)2 and ZnSO4 for that of M1. A 50-μl aliquot of the supernatant was injected onto a C18 reversed-phase column in each instance. The mobile phases employed were 0.03 M phosphoric acid—acetonitrile (50:40, v/v) for azosemide and 0.03 M phosphoric acid/0.2 M acetic acid—acetonitrile (83:17, v/v) for M1. The flow-rate was 1.5 ml/min in both instances. The column effluent was monitored by ultraviolet detection at 240 and 236 nm for azosemide and M1, respectively. The retention times for azosemide and M1 were 6.0 and 8.3 min, respectively. The detection limits for both azosemide and M1 in both human plasma and urine were 50 ng/ml. The coefficients of variation of the assay were generally low (below 11.0%) for plasma, urine, blood and tissue homogenates. No interferences from endogenous substances or other diuretics tested were observed.  相似文献   

9.
We extended the application of a sensitive high-performance liquid chromatography assay of amoxicillin developed in this laboratory for human plasma and middle ear fluid (MEF) to other sample matrices including chinchilla plasma or MEF and human and chinchilla whole blood with minor modification and validated the limit of quantitation at 0.25 μg/ml with a 50-μl sample size for human and chinchilla plasmas or MEFs. Amoxicillin and cefadroxil, the internal standard, were extracted from 50 μl of the samples with Bond Elut C18 cartridges. The extract was analyzed on a Keystone MOS Hypersil-1 (C8) column with UV detection at 210 nm. The mobile phase was 6% acetonitrile in 5 mM phosphate buffer, pH 6.5 and 5 mM tetrabutylammonium. The within-day coefficients of variation were 2.7–9.9 (n=4) and 1.7–7.2% (n=3) for chinchilla plasma and MEF samples, respectively; 2.8–8.1% (n=3) and 2.9–4.7% (n=3) for human and chinchilla whole blood, respectively. An alternative mobile phase composition for chinchilla plasma and MEF samples reduced the analysis time significantly.  相似文献   

10.
A rapid, sensitive, specific liquid chromatographic method has been developed for the determination of therapeutic levels of ganciclovir in human plasma. Plasma (1 ml) and acyclovir (I.S.) were treated with 50% trichloroacetic acid. The supernatant was neutralized with 2 M NaOH and purified with chloroform. The aqueous phase (80 μl) was analyzed by a 3-μm Hypersil ODS C18 column with 0.04 M triethylamine–0.1 M sodium dihydrogen phosphate monohydrate as the mobile phase (1 ml/min) and ultraviolet detection at 254 nm. Calibration was linear from 50 to 10 000 ng/ml. Intra- and inter-day C.V. did no exceed 6.65%. The detection limit was about 10 ng/ml.  相似文献   

11.
A simple, specific, and sensitive high-performance liquid chromatographic (HPLC) method for the determination of riboflavin directly in urine samples using a fixed-wave-length spectrofluorometer is described. Centrifuged raw urine samples (50 μl) are injected onto a reversed-phase microparticulate C18 column. The eluent is 0.01 M KH2PO4 (pH 5.0)—methanol (65:35). This method is capable of differentiating riboflavin from riboflavin-5-phosphate, non-riboflavin fluorescing components in urine, and photo-degraded riboflavin. The method shows good reproducibility and is linear to at least 12 μg/ml. The sensitivity of this procedure, at the 95% confidence limit, determined by linear regression analysis, is estimated to be 0.05 μg/ml using peak height and 0.07 μg/ml using peak area. This HPLC method is compared to an automated fluorometric method for riboflavin. The coefficient of linear regression of this comparison is Y = 0.858 + 0.893X, where X is the HPLC method and Y is the fluorometric method.  相似文献   

12.
A rapid and economical high-performance liquid chromatographic assay is described for norfloxacin in serum. Samples (100 μl) containing N-ethylnorfloxacin as the internal standard were extracted into 1 ml of chloroform. Chromatography was performed at 30°C on a 40×3.2 mm I.D. C18 guard cartridge (3 μm spherical particles) using a mobile phase of 11% (v/v) acetonitrile in 0.01 M phosphate buffer (pH 2.5) containing 0.001 M triethylamine, and pumped at 1 ml/min. Detection was at 279 nm. The retention times of norfloxacin and internal standard were 1.9 and 2.9 min, respectively. Calibration curves were linear (r>0.999) from 0.1 mg/l to at least 2.0 mg/l. Within-day and between-day precision (C.V.) were 8.6% or less, and accuracy was 5.3% or less. Absolute assay recovery of norfloxacin was over 70%.  相似文献   

13.
A high-performance liquid chromatographic method for the routine determination of elevated urinary levels of the serotonin metabolite 5-hydroxytryptophol (5-HTOL) is described. Urine samples were treated with β-glucuronidase, and 5-HTOL was isolated by solid-phase extraction on a small Sephadex G-10 column prior to injection onto an isocratically eluted C18 reversed-phase column. Detection of 5-HTOL was performed electrochemically at +0.60 V vs. Ag/AgCl. The limit of detection was ca. 0.05 μM, and the intra-assay coefficients of variation were below 6% with urine samples containing 0.2 and 2.1 μM 5-HTOL and a standard solution of 2.0 μM (n = 5). The recovery of 5-HTOL after the sample clean-up procedure was close to 100%. A good correlation (r2 = 0.97; n = 12) was obtained between the present method and a sensitive and specific gas chromatographic—mass spectrometric method. The total (free plus conjugated) 5-HTOL levels in urine were normally below 0.2 μM, but after an acute dose of alcohol they increased to 0.5–15 μM.  相似文献   

14.
Achiral and chiral HPLC methods were developed for clinafloxacin, a quinolone antimicrobial agent. For achiral assay, analytes were isolated from plasma by precipitating plasma proteins. Separation was achieved on a C18 column using an isocratic eluent of ion pairing solution–acetonitrile (80:20, v/v) at 1.0 ml/min with UV detection at 340 nm. The ion pairing solution was 0.05 M citric acid, 1.15 mM tetrabutylammonium hydroxide and 0.1% ammonium perchlorate. Inter-assay accuracy was within 4.9% with an inter-assay precision of 3.7% over a quantitation range of 0.025 to 10.0 μg/ml. For chiral assay, analytes were isolated from plasma by solid-phase extraction. Separation was achieved on a Crownpak CR(+) column using an isocratic eluent of water–methanol (88:12, v/v) containing 0.1 mM decylamine at 1.0 ml/min with UV detection at 340 nm. Perchloric acid was added to adjust pH to 2. Inter-assay accuracy was within 3.5% with a inter-assay precision of 5.4% over a quantitation range of 0.040 to 2.5 μg/ml.  相似文献   

15.
A reliable high-performance liquid chromatographic method has been validated for determination of gallamine in rat plasma, muscle tissue and microdialysate samples. A C18 reversed-phase column with mobile phase of methanol and water containing 12.5 mM tetrabutyl ammonium (TBA) hydrogen sulphate (22:78, v/v) was used. The flow-rate was 1 ml/min with UV detection at 229 nm. Sample preparation involved protein precipitation with acetonitrile for plasma and muscle tissue homogenate samples. Microdialysate samples were injected into the HPLC system without any sample preparation. Intra-day and inter-day accuracy and precision of the assay were <13%. The limit of quantification was 1 μg/ml for plasma, 1.6 μg/g for muscle tissue and 0.5 μg/ml for microdialysate samples. The assay was applied successfully to analysis of samples obtained from a pharmacokinetic study in rats using the microdialysis technique.  相似文献   

16.
A simple and sensitive high-performance liquid chromatographic (HPLC) method with UV absorbance detection is described for the quantitation of risperidone and its major metabolite 9-hydroxyrisperidone in human plasma, using clozapine as internal standard. After sample alkalinization with 1 ml of NaOH (2 M) the test compounds were extracted from plasma using diisopropyl ether–isoamylalcohol (99:1, v/v). The organic phase was back-extracted with 150 μl potassium phosphate (0.1 M, pH 2.2) and 60 μl of the acid solution was injected into a C18 BDS Hypersil analytical column (3 μm, 100×4.6 mm I.D.). The mobile phase consisted of phosphate buffer (0.05 M, pH 3.7 with 25% H3PO4)–acetonitrile (70:30, v/v), and was delivered at a flow-rate of 1.0 ml/min. The peaks were detected using a UV detector set at 278 nm and the total time for a chromatographic separation was about 4 min. The method was validated for the concentration range 5–100 ng/ml. Mean recoveries were 98.0% for risperidone and 83.5% for 9-hydroxyrisperidone. Intra- and inter-day relative standard deviations were less than 11% for both compounds, while accuracy, expressed as percent error, ranged from 1.6 to 25%. The limit of quantitation was 2 ng/ml for both analytes. The method shows good specificity with respect to commonly prescribed psychotropic drugs, and it has successfully been applied for pharmacokinetic studies and therapeutic drug monitoring.  相似文献   

17.
An isocratic HPLC method was developed and validated for the quantitation of methocarbamol in human plasma. Methocarbamol and internal standard in 200 μl of human plasma were extracted with ethyl acetate, evaporated to dryness and reconstituted in water. Separation was achieved on a reversed-phase C18 column with a mobile phase of methanol—0.1 M potassium phosphate monobasic—water (35:10:55, v/v/v). The detection was by ultraviolet at 272 nm. Linearity was established at 1–100 μg/ml (r > 0.999). The limit of quantitation was designed as 1 μg/ml to suit pharmacokinetic studies. Inter-day precision and accuracy of the calibration standards were 1.0 to 3.6% coefficients of variance (C.V.) and −2.0 to +1.6% relative error (R.E.). Quality controls of 3, 20 and 70 μg/ml showed inter-day precision and accuracy of 2.5 to 3.6% C.V. and −0.9 to −0.4% R.E. Recovery of methocarbamol was 91.4–100.3% in five different lots of plasma. The method was shown to be applicable on different brands of C18 columns.  相似文献   

18.
A high-performance liquid chromatography assay for hydroxyurea in human serum was developed based on a commercial colorimetric assay kit for urea (Sigma Diagnostics). Serum (0.5 ml), spiked with methylurea as an internal standard, was treated with 70% perchloric acid. Supernatant (0.2 ml) was combined with 0.7 ml of BUN acid reagent and 0.6 ml of BUN color reagent. The resulting colored reactant (100 μl) was analyzed on a 300×3.9 mm Bondclone 10 C18 column coupled with a UV–Vis detector, at 449 nm. The mobile phase was 13% acetonitrile in water. Retention times of colored derivatives of hydroxyurea and methylurea were 6.5 and 12.2 min, respectively. The log–log calibration curve was linear from 0.0065 to 1.31 mM. Average accuracy was 99.9±4.0% and the intra- and inter-day error of assay did not exceed 11%.  相似文献   

19.
Salicylic acid (0.5 mM) is used as a trapping reagent of hydroxyl radical, and the formed 2,3- and 2,5-dihydroxybenzoic acids were collected via an on-line microdialysis device from the blood vessels. This study revealed the use of a sensitive liquid chromatographic system with electrochemical detection for the determination of 2,3- and 2,5-dihydroxybenzoic acids. Mobile phase consisted of 0.1 M monochloroacetic acid, 10 mM EDTA, 0.5 mM sodium octylsulfate, 20% acetonitrile and 5% tetrahydrofuran in 1 l (pH 3.0 adjusted with 1 M NaOH), and the flow-rate of 0.05 ml/min were found to be optimum. Isocratic separation of these adducts on a microbore column (reversed-phase C18, 150×1 mm I.D., 5 μm) was achieved within 10 min. The optimal applied potential of dihydroxybenzoic acids was set at 750 mV based on a hydrodynamic study. This method has the detection limits of 1.3 pmol/ml (or 0.2 ng/ml) for 2,3- and 2,5-dihydroxybenzoic acids in Ringer solution (at signal-to-noise ratio=3).  相似文献   

20.
A sensitive and selective method for the determination of cefuroxime in bronchoalveolar lavage (BAL) fluid using high-performance liquid chromatography (HPLC) with UV detection at 280 nm after solid-phase extraction with C18 cartridges was developed. A Waters symmetry C18 column was used and the mobile phase was acetonitrile-0.05 M ammonium phosphate buffer (pH 3.2) (15:85, v/v). The method enabled the determination of cefuroxime at concentrations below 100 ng/ml, with a linear calibration curve at concentrations of 5–100 ng/ml for 400 μl of BAL. The intra- and inter-assay coefficient of variations for 10, 40 and 80 ng/ml were between 5.3 and 8.9%. Analytical recoveries were between 92.7 and 106.2%. The detection limit was 1 ng/ml at a signal-to-noise ratio of 3:1 using 400 μl of BAL. The method was successfully used for the analysis of BAL fluid from patients after oral administration of 500 mg cefuroxime axetil twice daily.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号