首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and selective method for the determination of cefuroxime in bronchoalveolar lavage (BAL) fluid using high-performance liquid chromatography (HPLC) with UV detection at 280 nm after solid-phase extraction with C18 cartridges was developed. A Waters symmetry C18 column was used and the mobile phase was acetonitrile-0.05 M ammonium phosphate buffer (pH 3.2) (15:85, v/v). The method enabled the determination of cefuroxime at concentrations below 100 ng/ml, with a linear calibration curve at concentrations of 5–100 ng/ml for 400 μl of BAL. The intra- and inter-assay coefficient of variations for 10, 40 and 80 ng/ml were between 5.3 and 8.9%. Analytical recoveries were between 92.7 and 106.2%. The detection limit was 1 ng/ml at a signal-to-noise ratio of 3:1 using 400 μl of BAL. The method was successfully used for the analysis of BAL fluid from patients after oral administration of 500 mg cefuroxime axetil twice daily.  相似文献   

2.
A reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed and validated for the quantitative determination of paclitaxel in human urine. A comparison is made between solid-phase extraction (SPE) and liquid-liquid extraction (LLE) as sample pretreatment. The HPLC system consists of an APEX octyl analytical column and acetonitrile-methanol-0.2 μM ammonium acetate buffer pH 5 (4:1:5, v/v) as the mobile phase. Detection is performed by UV absorbance measurement at 227 nm. The SPE procedure involves extraction on Cyano Bond Elut columns. n-Butylchloride is the organic extraction fluid used for the LLE. The recoveries of paclitaxel in human urine are 79 and 75% for SPE and LLE, respectively. The accuracy for the LLE and SPE sample pretreatment procedures is 100.4 and 104.9%, respectively, at a 5 μg/ml drug concentration. The lower limit of quantitation is 0.01 μg/ml for SPE and 0.25 μg/ml for LLE. Stability data of paclitaxel in human urine are also presented.  相似文献   

3.
An improved high-performance liquid chromatographic (HPLC) method utilizing solid-phase extraction (SPE) and midbore chromatography was developed for the determination of ranitidine in human plasma. A mobile phase of 20 mM K2HPO4-acetonitrile-triethylamine (87.9:12.0:0.1, v/v) pH 6.0 was used with a phenyl analytical column and ultraviolet detection (UV). The method demonstrated linearity from 25 to 1000 ng/ml in 500 μl of plasma with a detection limit of 10 ng/ml. The method was utilized in a pharmacokinetic study evaluating the effects of pancreatico-biliary secretions on ranitidine absorption.  相似文献   

4.
A simple and reproducible method for the analysis of ampicillin in human serum was developed. Serum samples were extracted using solid-phase extraction disk cartridges containing a sorbent of styrene divinyl/benzene. Extracts were separated by reversed-phase C18 high-performance liquid chromatography with UV detection at 220 nm. The mobile phase consisted of acetonitrile–10 mM NaH2PO4 (6.5:93.5, v/v). Using this extraction procedure, recovery from serum was 98.4±5.6%. The quantitation limit was 0.19 μg/ml using 0.5 ml of serum. The calibration curves from 0.19 to 9.41 μg/ml were linear with correlation coefficients of 0.999. This method is suitable for therapeutic drug monitoring of ampicillin (ABPC) after oral administration of lenampicillin hydrochloride.  相似文献   

5.
The determination of 3-hydroxyquinine in urine and plasma samples is described. Extraction was performed using a mixture of toluene–butanol (75:25, v/v), followed by back-extraction into the mobile phase, which consisted of 0.1 M phosphate buffer, acetonitrile, tetrahydrofuran and triethylamine. A reversed-phase liquid chromatography system with fluorescence detection and a CT-sil C18 column were used. The within-assay coefficient of variation of the method was 2% at the higher concentration values in plasma, 2.95 μM, 4% at 227 nM and 9% at the lower limit of quantitation, 4.5 nM. In urine, the coefficient of variation was 11% at the lower concentration, 227 nM and was 3% at 56.8 μM. The between-assay coefficient of variation was 4% at the low concentration (5.1 nM) in plasma, 2% at 276.8 nM and 3% at 1.97 μM. In urine, the between assay coefficient of variation was 4% at 204.6 nM, 3% at 5.12 μM and 2% at 56.8 μM.  相似文献   

6.
A method utilising solid-phase extraction followed by high-performance liquid chromatography has been developed to quantify novel arylene bis(methylketone) chemotherapeutics present in biological samples. The samples are extracted over cyanopropylsilane solid-phase extraction cartridges using 10 mM heptanesulfonate-10 mM tetramethylammonium chloride-4.2 mM H3PO4-95% CH3CN as the eluent. Analytical chromatography utilises a diisopropyl-C8 reversed-phase column and a 7.5–45% CH3CN gradient in 10 mM heptanesulfonate-10 mM tetramethylammonium chloride-4.2 mM H3PO4-H2O. Detection was by ultraviolet spectrophotometry at 300 or 240 nm. The linear response of the assay was found to extend from at least 100 μg/ml down to 97.66 ng/ml for a 100 μl injection. The assay system was utilised to determine the plasma kinetics of the compounds in mice, where all the drugs were found to display rapid absorption and elimination following intraperitoneal dosing. In vitro and in vivo studies of metabolism demonstrated that each of the compounds produced several metabolites, and that this conversion could be extensive in vivo.  相似文献   

7.
Achiral and chiral HPLC methods were developed for clinafloxacin, a quinolone antimicrobial agent. For achiral assay, analytes were isolated from plasma by precipitating plasma proteins. Separation was achieved on a C18 column using an isocratic eluent of ion pairing solution–acetonitrile (80:20, v/v) at 1.0 ml/min with UV detection at 340 nm. The ion pairing solution was 0.05 M citric acid, 1.15 mM tetrabutylammonium hydroxide and 0.1% ammonium perchlorate. Inter-assay accuracy was within 4.9% with an inter-assay precision of 3.7% over a quantitation range of 0.025 to 10.0 μg/ml. For chiral assay, analytes were isolated from plasma by solid-phase extraction. Separation was achieved on a Crownpak CR(+) column using an isocratic eluent of water–methanol (88:12, v/v) containing 0.1 mM decylamine at 1.0 ml/min with UV detection at 340 nm. Perchloric acid was added to adjust pH to 2. Inter-assay accuracy was within 3.5% with a inter-assay precision of 5.4% over a quantitation range of 0.040 to 2.5 μg/ml.  相似文献   

8.
A selective semi-automated solid-phase extraction (SPE) of the non-steroidal anti-inflammatory drugs diclofenac sodium, indomethacin and phenylbutazone from urine prior to high-performance liquid chromatography was investigated. The drugs were recovered from urine buffered at pH 5.0 using C18 Bond-Elut cartridges as solid sorbent material and mixtures of methanol–aqueous buffer or acetonitrile–aqueous buffer as washing and elution solvents. The extracts were chromatographed on a reversed-phase ODS column using 10 mM acetate buffer (pH 4.0)–acetonitrile (58:42, v/v) as the mobile phase, and the effluent from the column was monitored at 210 nm with ultraviolet detection. Absolute recoveries of the anti-inflammatory drugs within the range 0.02–1.0 μg/ml were about 85% for diclofenac and indomethacin, and 50% for phenylbutazone without any interference from endogenous compounds of the urine. The within-day and between-day repeatabilities were in all cases less than 5% and 10%, respectively. Limits of detection were 0.007 μg/ml for diclofenac sodium and indomethacin and 0.035 μg/ml for phenylbutazone, whereas limits of quantitation were 0.02 μg/ml for diclofenac and indomethacin and 0.1 μg/ml for phenylbutazone.  相似文献   

9.
A high-performance liquid chromatographic method for the routine determination of elevated urinary levels of the serotonin metabolite 5-hydroxytryptophol (5-HTOL) is described. Urine samples were treated with β-glucuronidase, and 5-HTOL was isolated by solid-phase extraction on a small Sephadex G-10 column prior to injection onto an isocratically eluted C18 reversed-phase column. Detection of 5-HTOL was performed electrochemically at +0.60 V vs. Ag/AgCl. The limit of detection was ca. 0.05 μM, and the intra-assay coefficients of variation were below 6% with urine samples containing 0.2 and 2.1 μM 5-HTOL and a standard solution of 2.0 μM (n = 5). The recovery of 5-HTOL after the sample clean-up procedure was close to 100%. A good correlation (r2 = 0.97; n = 12) was obtained between the present method and a sensitive and specific gas chromatographic—mass spectrometric method. The total (free plus conjugated) 5-HTOL levels in urine were normally below 0.2 μM, but after an acute dose of alcohol they increased to 0.5–15 μM.  相似文献   

10.
Capillary reversed-phase high-performance liquid chromatography (RP-HPLC) was used to determine acetylmethylprednisolone (A-MP) that had been administered to feline spinal cord tissue. The method used a 300 mm × 0.32 mm I.D. packed capillary octadecylsilyl (ODS) column and an isocratic mobile phase of 40 mM triethylamine formate (TEAF, pH 3.2)-acetonitrile (50:50, v:v). The chromatographic behavior of A-MP was evaluated with respect to peak-area and peak-height by varying the A-MP concentration (12–190 μM) with a fixed injection volume (1 μl), and by varying the injection volume (1–10 μl) with a fixed concentration (12 μM) of A-MP. The limit of detection (signal-to-noise ratio, 3:1) was 250 pg (600 fmol) of synthetic A-MP. Various amounts of A-MP directly spiked into feline spinal cord segments were solvent extracted, separated, and plotted against peak-area (r2 = 1.00). Background tissue without A-MP gives minimal (<1%) interference at 243 nm. The method also detects exogenous A-MP that was administered into feline spinal cord via an intrathecal injection. Furthermore, the presence of A-MP was confirmed via its molecular ion and corresponding product ions that were obtained by fast-atom bombardment tandem mass spectrometry (FAB-MS-MS).  相似文献   

11.
A rapid high-performance liquid chromatographic method for the quantitation of citalopram in human plasma is presented. The sample preparation involved liquid–liquid extraction of citalopram with hexane–isoamyl alcohol (98:2 v/v) and back-extraction of the drug to 0.02 M hydrochloric acid. Liquid chromatography was performed on a cyano column (45×4.6 mm, 5 μm particles), the mobile phase consisted of an acetonitrile–phosphate buffer, pH 6.0 (50:50, v/v). The run time was 2.6 min. The fluorimetric detector was set at an excitation wavelength of 236 nm and an emission wavelength of 306 nm. Verapamil was used as the internal standard. The limit of quantitation was 0.96 ng/ml using 1 ml of plasma. Within- and between-day precision expressed by relative standard deviation was less than 7% and inaccuracy did not exceed 6%. The assay was applied to the analysis of samples from a pharmacokinetic study.  相似文献   

12.
A high-performance liquid chromatography (HPLC) analytical method for the determination of oxolinic acid and flumequine in Artemia nauplii is described. The samples were extracted and cleaned up by a solid-phase extraction (SPE) procedure using SPE C18 cartridges. Oxolinic acid and flumequine were determined by reversed-phase HPLC using a mobile phase of methanol–0.1 M phosphate buffer, pH 3 (45:55, v/v) and a UV detection wavelength of 254 nm. Calibration curves were linear for oxolinic acid in the range of 0.2–50 μg/g (r2=0.9998) and for flumequine in the range of 0.3–50 μg/g (r2=0.9994). Mean recoveries amounted to 100.8% and 98.4% for oxolinic acid and flumequine, respectively. The quantification limit was 0.2 μg/g for oxolinic acid and 0.3 μg/g for flumequine. Quantitative data from an in vivo feeding study indicated excellent uptake of both drugs by Artemia nauplii.  相似文献   

13.
A single-solvent extraction step high-performance liquid chromatographic method is described for quantitating zolpidem in rat serum microsamples (50 μl). The separation used a 2.1 mm I.D. reversed-phase OD-5-100 C18 column, 5 μm particle size with an isocratic mobile phase consisting of methanol–acetonitrile–26 mM sodium acetate buffer (adjusted to pH 2.0 with 40% phosphoric acid) containing 0.26 mM tetrabutylammonium phosphate (13:10:77, v/v/v). The detection limit was 3 ng/ml for zolpidem using an ultraviolet detector operated at 240 nm. The recovery was greater than 87% with analysis performed in 12 min. The method is simple, rapid, and applicable to pharmacokinetic studies of zolpidem after administering two intravenous bolus doses (1 and 4 mg/kg) in rats.  相似文献   

14.
A fully automated on-line method for determination of nortriptyline in human serum was developed using an ASPEC XL (Gilson) solid-phase extraction apparatus in combination with high-performance liquid chromatography. Solid phase extraction was performed on cyanopropyl cartridges. HPLC was carried out using a C18 column with a mobile phase of acetonitrile–0.01 M triethylamine (34:66 v/v) buffer, pH 3.0. UV detection was at 242 nm. The Inter-day CV% was <5%. Comparison with liquid–liquid extraction of serum from patients treated with nortriptyline showed good agreement. Studies of analytical interference from coadministered psychoactive drugs revealed that only imipramine and a methotrimeprazine metabolite interfered.  相似文献   

15.
We present a method for the enantioselective analysis of propafenone in human plasma for application in clinical pharmacokinetic studies. Propafenone enantiomers were resolved on a 10-μm Chiralcel OD-R column (250×4.6 mm I.D.) after solid-phase extraction using disposable solid-phase extraction tubes (RP-18). The mobile phase used for the resolution of propafenone enantiomers and the internal standard propranolol was 0.25 M sodium perchlorate (pH 4.0)–acetonitrile (60:40, v/v), at a flow-rate of 0.7 ml/min. The method showed a mean recovery of 99.9% for (S)-propafenone and 100.5% for (R)-propafenone, and the coefficients of variation obtained in the precision and accuracy study were below 10%. The proposed method presented quantitation limits of 25 ng/ml and was linear up to a concentration of 5000 ng/ml of each enantiomer.  相似文献   

16.
A high-performance liquid chromatographic (HPLC) assay has been developed for the determination of the antifungal drug fluconazole in saliva and plasma of patients infected with the human immunodeficiency virus (HIV). Samples can be heated at 60°C for 30 min to inactivate the virus without loss of the analyte. The sample pretreatment involves a liquid-liquid extraction with chloroform-1-propanol (4:1, v/v). The chromatographic analysis is performed on a Lichrosorb RP-18 (5 μm) column by isocratic elution with a mobile phase of 0.01 M acetate buffer (pH 5.0)-methanol (70:30, v/v) and ultraviolet (UV) detection at 261 nm. The lower limit of is 100 ng/ml in plasma (using 500-μl samples) and 1 μg/ml in saliva (using 250-μl samples) and the method is linear up to 100 μg/ml in plasma and saliva. At a concentration of 5 μg/ml the within-day and between-day precision in plasma are 7.1 and 5.7%, respectively. In saliva the within-day and between-day precision is 10.8% (at 5 μg/ml). The methodology is now being used in pharmacokinetic studies in HIV-infected patients in our hospital.  相似文献   

17.
An improved high-performance liquid chromatographic assay for the cytostatic drug mitomycin C in plasma is presented. The principal steps are precipitation of plasma proteins with acetonitrile, lyophilization of the supernatant and reversed-phase chromatography on a Hypersil ODS 5 μm column with 0.01 M NaH2PO4 buffer (pH 6.5)-methanol (70:30, v/v) in isocratic mode. At a flow-rate of 1.3 ml/min a column pressure of 180–220 bar resulted. Porfiromycin served as internal standard. UV detection was performed at 365 nm. Quantitation limit based on a coefficient of variation <10% in intra- and inter-day assay was 5 μg/l mitomycin C, detection limit based on a signal-to-noise ratio of 3 was 1 μg/l. Recovery was 100% and linearity was shown for the whole range of concentration (1–500 μg/l). None of the five drugs used during chemoembolisation interfered with the assay in vitro. The assay meets the requirements for pharmacokinetic studies of mitomycin C in patients as regards sensitivity and ease of use.  相似文献   

18.
19.
A rapid and sensitive method for the assay of zonisamide in serum was developed using a solid-phase extraction technique followed by high-performance liquid chromatography. A 20-μl volume of human serum was first purified with a Bond-Elut cartridge column. Then, the methanol eluate was injected onto a reversed-phase HPLC column with a UV detector. The mobile phase was acetonitrile—methanol—distilled water (17:20:63, v/v) and the detection wavelength was 246 nm. The detection limit was 0.1 μg/ml in serum. The coefficients of variation were 4.2–5.6% and 5.1–9.1% for the within-day and between-day assays, respectively. This method can be used for clinical pharmacokinetic studies of zonisamide in serum even in infant patients with epilepsy.  相似文献   

20.
A sensitive high-performance liquid chromatographic method using fluorescence detection has been developed for sotalol determination in small plasma samples of children and newborns with limited blood volume. In sample sizes of 100 μl of plasma, sotalol was extracted using an internal standard and solid-phase extraction columns. Chromatographic separation was performed on a Spherisorb C6 column of 150×4.6 mm I.D. and 5 μm particle size at ambient temperature. The mobile phase consisted of acetonitrile–15 mM potassium phosphate buffer (pH 3.0) (70:30, v/v). The excitation wavelength was set at 235 nm, emission at 300 nm. The flow-rate was 1 ml/min. Sotalol and the internal standard atenolol showed recoveries of 107±8.9 and 97±8.1%, respectively. The linearity range for sotalol was between 0.07 and 5.75 μg/ml, the limit of quantitation 0.09 μg/ml. Precision values expressed as percent relative standard deviation of intra-assay varied between 0.6 and 13.6%, that of inter-assay between 2.4 and 14.4%. Accuracy varied between 86.1 and 109.8% (intra-assay) and 95.4 and 103.3% (inter-assay). Other clinically used antiarrhythmic drugs did not interfere. As an application of the assay, sotalol plasma concentrations in a 6-year-old child with supraventricular tachycardia treated with oral sotalol (3.2 mg/kg per day) are reported.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号