首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
Jiang X  Feng S  Tian R  Han G  Jiang X  Ye M  Zou H 《Proteomics》2007,7(4):528-539
An approach was developed to automate sample introduction for nanoflow LC-MS/MS (microLC-MS/MS) analysis using a strong cation exchange (SCX) trap column. The system consisted of a 100 microm id x 2 cm SCX trap column and a 75 microm id x 12 cm C18 RP analytical column. During the sample loading step, the flow passing through the SCX trap column was directed to waste for loading a large volume of sample at high flow rate. Then the peptides bound on the SCX trap column were eluted onto the RP analytical column by a high salt buffer followed by RP chromatographic separation of the peptides at nanoliter flow rate. It was observed that higher performance of separation could be achieved with the system using SCX trap column than with the system using C18 trap column. The high proteomic coverage using this approach was demonstrated in the analysis of tryptic digest of BSA and yeast cell lysate. In addition, this system was also applied to two-dimensional separation of tryptic digest of human hepatocellular carcinoma cell line SMMC-7721 for large scale proteome analysis. This system was fully automated and required minimum changes on current microLC-MS/MS system. This system represented a promising platform for routine proteome analysis.  相似文献   

2.
Plasma lipoproteins were isolated at d less than 1.225 g/ml from nonhuman primates of three species, cynomolgus, rhesus, and African green (vervet) monkeys. Individual lipoprotein classes were separated by high performance gelfiltration chromatography and low density lipoprotein (LDL) molecular weight was determined. A comparison was made using column configurations including TSK 3000 SW, 4000 SW, and 5000 PW columns. Due to its relative simplicity, stability, and economy, a single 5000 PW column was selected for most of the work. The recovery of lipoprotein cholesterol from the column averaged 91 +/- 2.5%. A comparison of the immunologic, chemical, and electrophoretic properties of high density lipoproteins (HDL) and LDL isolated by this technique with those of HDL and LDL isolated by conventional agarose column chromatography indicated that lipoproteins isolated by high performance gel-filtration chromatography were intact and reasonably free of cross contamination. A standard preparation of 125I-labeled LDL was added to the d less than 1.225 g/ml lipoprotein fraction just prior to separation and a relative size index, r1, was determined. When r1 values for a large number of samples were compared with the log of the LDL molecular weight (determined by agarose column chromatography) a linear relationship was found with a correlation coefficient, r = 0.85. The regression equation for this relationship could be used to calculate LDL molecular weights from the r1 value. These values agreed with LDL molecular weight determined by flotation equilibrium analysis in the analytical ultracentrifuge. We conclude that high performance gel-filtration chromatography using the TSK 5000 PW column provides an analytical and preparative technique for simultaneous separation of individual lipoproteins and determination of LDL molecular weight.  相似文献   

3.
The performance of three different affinity and immunoaffinity subtraction spin columns was investigated for the removal of the most abundant proteins in human cerebrospinal fluid (CSF). A pool of human CSF was processed with the spin columns and both the bound and flow through fractions were compared with each other and with intact CSF using 1D gel electrophoresis and nanoLC–MALDI-TOF/TOF-MS analysis. MASCOT MS/MS ionscores were compared before and after processing with the columns. The non-specific co-removal of proteins bound to the high abundant proteins, so called “sponge effect” was also examined for each spin column. The reproducibility of one of the spin columns, ProteomeLab IgY-12 proteome partitioning spin column, was further investigated by isobaric tags for relative and absolute quantification (iTRAQ) labeling and MS/MS analysis. Overall, 173 unique proteins were identified on a 95% MudPIT confidence scoring level. For all three spin columns, the number of proteins identified and their MASCOT scores were increased up to 10 times. The largest degree of non-specific protein removal was observed for a purely affinity based albumin removal column, where 28 other proteins also were present. The ProteomeLab IgY-12 proteome partitioning spin column showed very high reproducibility when combined with iTRAQ labeling and MS/MS analysis. The combined relative standard deviation (R.S.D.) for the high abundant protein removal, iTRAQ labeling and nanoLC–MALDI-TOF/TOF-MS analysis was less than 17.5%.  相似文献   

4.
A high-speed liquid chromatograph equipped with a gel permeation column (Toyo Soda TSK GEL SW 3000) was directly connected to an atomic absorption spectrophotometer for rapid analysis of metalloproteins and applied for analysis of metallothionein. Although the column used in the present study exhibits a nonselective adsorption for metals attached to biopolymers with low stability constants, the analytical system was shown to be practically useful, especially for metalloproteins with high stability constants. Metallothioneins were separated into two isometallothioneins on the column, indicating that the column has both gel chromatographic and ion-exchange chromatographic properties.  相似文献   

5.
A bioanalytical method was developed for the quantitation of methadone (MTD) and its primary metabolite, (EDDP) in plasma. The extraction step was performed within a capillary column packed with large particles (35x0.3 mm I.D.; d(p) 30 micrometer) at high flow-rate conditions (450 microliter/min). The separation was performed on a microbore analytical column (55x2 mm I.D.; d(p) 3 micrometer) coupled to a mass spectrometer (MS). This procedure was based on a column-switching unit. Analytes of interest were retained on the precolumn by hydrophobic interactions and backflushed from the precolumn to the analytical column. The detection was carried out with a MS single quadrupole equipped with an electrospray interface. The total analysis time was 6 min. The limits of quantification were evaluated at 10 and 25 ng/ml for MTD and EDDP, respectively. At this level, good accuracies were obtained for both analytes with repeatability values less than 18%.  相似文献   

6.
Feng S  Pan C  Jiang X  Xu S  Zhou H  Ye M  Zou H 《Proteomics》2007,7(3):351-360
Immobilized metal affinity chromatography (IMAC) is a commonly used technique for phosphoproteome analysis due to its high affinity for adsorption of phosphopeptides. Miniaturization of IMAC column is essential for the analysis of a small amount of sample. Nanoscale IMAC column was prepared by chemical modification of silica monolith with iminodiacetic acid (IDA) followed by the immobilization of Fe3+ ion inside the capillary. It was demonstrated that Fe3+-IDA silica monolithic IMAC capillary column could specifically capture the phosphopeptides from tryptic digest of alpha-casein with analysis by MALDI-TOF MS. The silica monolithic IMAC capillary column was manually coupled with nanoflow RPLC/nanospray ESI mass spectrometer (muRPLC-nanoESI MS) for phosphoproteome analysis. The system was validated by analysis of standard phosphoproteins and then it was applied to the analysis of protein phosphorylation in mouse liver lysate. Besides MS/MS spectra, MS/MS/MS spectra were also collected for neutral loss peak. After database search and manual validation with conservative criteria, 29 singly phosphorylated peptides were identified by analyzing a tryptic digest of only 12 mug mouse liver lysate. The results demonstrated that the silica monolithic IMAC capillary column coupled with muRPLC-nanoESI MS was very suitable for the phosphoproteome analysis of minute sample.  相似文献   

7.
A rapid method for the quantification of L-ascorbic acid (1) in berry fruit by HPLC with photodiode array detection is presented. L-Ascorbic acid was resolved on a C18 monolithic column with aqueous buffer, after which the column was washed with acetonitrile to remove lipophilic compounds prior to re-equilibration for analysis of the next sample. Using the monolithic column format with high mobile phase flow rates, the entire separation, wash and re-equilibration were achieved in 3 min. With the exception of gooseberry (Ribes uva-crispa), for which an interfering compound co-eluted, concentrations of 1 could be determined in a wide range of berry fruits after extraction in metaphosphoric acid without further sample preparation. Using this extraction method, recoveries of 1 in excess of 85% were achieved. Fruit or juice extracts were stable in 5% metaphosphoric acid for at least 4 h and stability could be extended to longer than 150 h by the addition of the reducing agent tris(2-carboxethyl)phosphine hydrochloride. Following validation, the method was utilised for the phenotyping of fruit in a Scottish Crop Research Institute (SCRI) Ribes nigrum L. breeding population of 300 individuals. An improved extraction method allowed extraction, quantification of 1 and data analysis to be undertaken in less than one working week.  相似文献   

8.
A high-performance liquid chromatographic method has been developed for the forensic analysis of eleven frequently used cyclic antidepressant drugs (ADSs) (amitriptyline, amoxapine, clomipramine, desipramine, dosulepine, doxepin, imipramine, maprotiline, melitracen, mianserine and nortriptyline) using a recently developed reversed-phase column with 2 μm particles for the analysis of biological samples. The separation was carried out using two different C8 reversed-phase columns (column 1: 100 mm × 4.6 mm I.D., particle size 2 μm, TSK gel Super-Octyl; column 2: 100 mm × 4.6 mm I.D., particle size 5 μm, Hypersil MOS-C8) for comparison. The mobile phase was composed of methanol-20 mM KH2PO4 (pH 7) (60:40, v/v) and the flow-rate was 0.6 ml/min for both columns. The absorbance of the eluent was monitored at 254 nm. When the eleven drugs were determined, the sensitivity with the 2 μm particles was about five times greater than with the 5 μm particles. Retention times on column 1 were shorter than those on column 2. These results show that the new ODS column packing with a particle size of 2 μm gives higher sensitivity and a shorter analysis time than the conventional ODS column packing when applied to the analysis of biological samples.  相似文献   

9.
A superficially porous particle (SPP)‐based hydroxypropyl‐β‐cyclodextrin (HPBCD) chiral stationary phase (CSP) was produced and its chromatographic performance was compared to both 5 µm and 3 µm fully porous particle (FPP)‐based CSPs. The relative surface coverage of the HPBCD chiral selector on each particle was approximately equal, which resulted in equivalent enantiomeric selectivity (α) values on each phase when constant mobile phase conditions were used. Under such conditions, the SPP column resulted in greatly reduced analysis times and three times greater efficiencies compared to the FPP columns. When higher flow rates were used, efficiency gains per analysis times were five times greater for the SPP column compared to the FPP‐based columns. When the mobile phases were altered to give similar analysis times on each column, resolution values were doubled for the SPP column. Finally, the novel SPP based HPBCD column proved to be stable for 500 injections under high flow rate (4.5 mL/min) and high pressure (400 bar) conditions used for an ultrafast (~45 sec) enantiomeric separation. Chirality 27:788–794, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

10.
A rapid isocratic method for determining the total phosphatidylcholine and disaturated phosphatidylcholine levels in lung surfactant preparations by high performance liquid chromatography (HPLC) is described. The analysis was performed on a 3.9 x 300 mm mu-Porasil column with detection by refractive index. The lipids were eluted with a solvent system of chloroform-acetonitrile-methanol-water-85% phosphoric acid 650:650:500:130:2 (v/v/v/v/v). A 4.6 x 30 mm silica guard column was used in place of an injector loop which served as a sample concentrator and purifier. Phosphatidylinositol, phosphatidylserine, phosphatidylethanolamine, and phosphatidylglycerol, all known components of lung surfactants, were eluted from the loop column and were prevented from reaching the analytical column. Sphingomyelin and lysophosphatidylcholine elute later than the phosphatidylcholines on the analytical column. The method was developed so that phosphatidylcholines elute as a single peak regardless of the fatty acid chain length (C12-C20). When the sample was first oxidized with a potassium permanganate-potassium metaperiodate solution, and potentially interfering oxidation products were removed by extraction into a basic aqueous phase, then only the disaturated phosphatidylcholines were analyzed.  相似文献   

11.
Serum analysis represents an extreme challenge due to the dynamic range of the proteins of interest, and the high structural complexity of the constituent proteins. In serum, the quantities of proteins and peptides of interest range from those considered "high abundance", present at 2-70% by mass of total protein, to those considered "low abundance", present at 10(-12) M or less. This range of analytical target molecules is outside the realm of available technologies for proteomic analysis. Therefore, in this study, we have developed a workflow toward addressing the complexity of these samples through the application of multidimensional separation techniques. The use of reversed-phase methods for the separation and fractionation of protein samples has been investigated, with the goal of developing an optimized serum separation for application to proteomic analysis. Samples of human serum were depleted of the six most abundant proteins, using an immunoaffinity LC method, then were separated under a variety of reversed-phase (RP) conditions using a macroporous silica C18 surface modified column material. To compare the qualities of the RP separations of this complex protein sample, absorbance chromatograms were compared, and fractions were collected for off-line SDS-PAGE and 2D-LC-MS/MS analysis. The column fractions were further investigated by determination of protein identities using either whole selected fractions, or gel bands excised from SDS-PAGE gels of the fractions. In either case samples underwent tryptic fragmentation and peptide analysis using MALDI-MS or LC-MS/MS. The preferred conditions for RP protein separation exhibited reproducibly high resolution and high protein recoveries (>98%, as determined by protein assay). Using the preferred conditions also permitted high column mass load, with up to 500 microg of protein well tolerated using a 4.6 mm ID x 50 mm column, or up to 1.5 mg on a 9.4 mm ID x 50 mm column. Elevated column temperature (80 degrees C) was observed to be a critical operational parameter, with poorer results observed at lower temperatures. The combination of sample simplification by immunoaffinity depletion combined with a robust and high recovery RP-HPLC fractionation yields samples permitting higher quality protein identifications by coupled LC-MS methods.  相似文献   

12.
Peptidome analysis has received increasing attention in recent years. Cancer diagnosis by serum peptidome has also been reported by peptides' profiling for discovery of peptide biomarkers. Tissue, which may have a higher biomarker concentration than blood, has not been investigated extensively by means of peptidome analysis. Here, a method for the peptidome analysis of mouse liver was developed by the combination of size exclusion chromatography (SEC) prefractionation with nano-liquid chromatography-tamdem mass spectrometry (nanoLC-MS/MS) analysis. The extracted peptides from mouse liver were separated according to their molecular weight using a size exclusion column. MALDI-TOF MS was used to characterize the molecular weight distribution of the peptides in fractions eluted from the SEC column. The low molecular weight (LMW) (MW < 3000 Da) peptides in the collected fractions were directly analyzed by LC-MS/MS which resulted in the identification of 1181 unique peptides (from 371 proteins). The high molecular weight (HMW) (MW > 3000 Da) peptides in the early two fractions from the SEC column were first digested with trypsin, and the resulted digests were then analyzed by LC-MS/MS, which led to the identification of 123 and 127 progenitor proteins of the HMW peptides in fractions 1 and 2, respectively. Analysis of the peptides' cleavage sites showed that the peptides are cleaved in regulation, which may reflect the protease activity and distribution in body, and also represent the biological state of the tissue and provide a fresh source for biomarker discovery.  相似文献   

13.
Two dimensional high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (2D-HPLC-ESI-MS/MS) is one of the most powerful techniques for high resolution, efficiency, and throughput separation and identification of proteomes. For a bottom-up strategy-based proteome analysis, usually multistep salt elution was needed in the first dimension separation by SCX, to simplify the peptides for the further second dimensional separation by RPLC. Here, by using a 30 cm-long serially coupled long column (SCLC) in the second dimension, we reduced the salt steps of SCX from 13 to 5 to shorten the total analysis time. Compared to the commonly applied 2D-HPLC with over 10-step salt elution in SCX and microRPLC with a short column (SC), named as SC-2D, the peak capacity of 2D-HPLC with a SCLC column, named as SCLC-2D, was increased 3.3-folds while the analysis time was increased by only 1.17-folds. Therefore, the time-based protein identification efficiency was ~55 protein groups/h, nearly 2-fold of that for SC-2D (~28 protein groups/h). With the further combination of assisted solubilization by ionic liquids and SCLC-2D, 608 integral membrane proteins (IMPs) (27.66% of the total 2198 proteins, FDR < 1%) were identified from rat brain, more than those obtained by the traditional urea method (252 unique IMPs, occupying 17.03% of total 1480 proteins). All of these results demonstrate the promise of the developed technique for large-scale proteome analysis.  相似文献   

14.
In this study a protocol for the analysis of thiamin and thiamin coenzymes in whole blood was developed. Thiamin and its coenzymes are analyzed by reversed phase liquid chromatography (RPLC), precolumn derivatisation with alkaline potassium ferricyanide and fluorescence detection, all at pH 10. Under these relatively high pH conditions the detectability of the analytes and the robustness of the method were substantially improved. The use of a high pH resistant RPLC column was a crucial step in developing this analysis method. Reproducibility, linearity, recovery, detection limit and column robustness were investigated. The within-batch CV was <2.5%, the between-batch CV <4.5%. The method was linear far above the physiological relevant concentration level. Recovery was almost 100% on an average. The limit of quantification was 1 nmol/l. The robustness of the RPLC column proved to be very high. Up to 1500 injections hardly any substantial changes in retention times and efficiency were observed. In summary: Using a high pH resistant RPLC column resulted in a robust, sensitive and precise method for the analysis of total Vitamin B1 and especially of TDP.  相似文献   

15.
Multidimensional HPLC is a powerful tool for the analysis of samples of a high degree of complexity. This work reports the use of multidimensional HPLC by coupling a RAM column with a chiral polysaccharide column to the analysis of Pantoprazole in human plasma by direct injection. The enantiomers from the plasma samples were separated with high resolution on a tris(3,5-dimethoxyphenylcarbamate) of amylose phase after clean-up by a RAM BSA octyl column. Water was used as solvent for the first 5 min in a flow-rate of 1.0 ml/min for the elution of the plasmatic proteins and then acetonitrile-water (35:65 v/v) for the transfer and analysis of pantoprazole enantiomers, which were detected by UV at 285 nm. Analysis time was 28 min with no time spent on sample preparation. A good linear relationship was obtained in the concentration range of 0.20 to 1.5 microg/ml for each enantiomer. Inter and intra-day precision and accuracy were determined by one low (0.24 microg/ml), one medium (0.70 microg/ml) and one high (1.3 microg/ml) plasma concentration and gave a C.V. varying from 1.80 to 8.43% and accuracy from 86 to 92%. Recoveries of pantoprazole enantiomers were in the range of 93.7-101.2%. The validated method was applied to the analysis of the plasma samples obtained from ten Brazilian volunteers who received an 80 mg oral dose of racemic pantoprazole and was able to quantify the enantiomers of pantoprazole in all clinical samples analyzed.  相似文献   

16.
A high-performance liquid chromatographic procedure for recovering subnanomole amounts of protein from SDS/polyacrylamide gel electroeluates in a form suitable for gas-phase sequence analysis has been developed. By a judicious choice of reversed-phase column packing, proteins can be retained at high concentrations of n-propanol (90-100%) where sodium dodecylsulfate and acrylamide gel-related contaminants are washed through the column. Retained proteins can be recovered from the column in high yield (greater than 90%) by the simultaneous adding of an ion-pairing reagent into the mobile phase and elution with a gradient of decreasing n-propanol concentration (i.e. an 'inverse or negative gradient'). Furthermore, by using a steep gradient (e.g. 50%/min) at a low flow rate (20-200 microliters/min) the proteins can be recovered in less than 100 microliters and can be used for gas-phase sequence analysis without further manipulation. This procedure is independent of sodium dodecylsulfate concentration (up to 1.2% w/v) in sample loading volumes of up to 1.5 ml. Microbore columns (2.1 mm internal diameter) have been employed for recovering small amounts of protein (1-100 micrograms from electroeluates of protein-containing gel spots while conventional columns (4.6 mm internal diameter) were used for isolating larger amounts of protein (greater than 500 micrograms) from electroeluates of preparative gel bands. The general utility of this inverse-gradient high-performance liquid chromatography procedure has been demonstrated by its successful application in recovering a wide variety of proteins from sodium dodecylsulfate gel electroeluates in a form suitable for N-terminal sequence analysis in the 10-500 pmol range.  相似文献   

17.
Pre-column derivatization of amikacin with 1-fluoro-2,4-dinitrobenzene in 25 μl of guinea pig plasma or human serum produced a stable chromophore which was measured by UV detection after rapid separation on normal-phase or reversed-phase high-performance liquid chromatography systems. The reversed-phase system, selected for routine analysis due to instability of the normal-phase column, consisted of an Ultrasphere-ODS C18 column preceded by a guard column, and used acetonitrile—water (68:32) as the mobile phase. A high degree of linearity was found in the range of 2—64 μg/ml with a coefficient of variation averaging less than 5%.  相似文献   

18.
A column switching high performance liquid chromatographic method with estimable sensitivity and accuracy was developed for the determination of cetirizine and ambroxol in human plasma using nebivolol as the internal standard. Plasma samples were prepared by liquid-liquid extraction in methylene chloride and a mixture of diethylether (80:20, v/v). The extracted samples were injected into a multifunctional clean-up column Supelcosil LCABZ (50 mm × 4.6 mm, 5 μm particle size) using mobile phase 1 comprising acetonitrile-phosphate buffer (pH 3.5; 20 mM) (20:80, v/v). The eluate of cetirizine and ambroxol were separated to an analytical Kromasil C(8) micro bore column (50 mm × 0.3 mm, 5 μm particle size) via a column switching device. A Kromasil C(18) analytical column (250 mm × 2.1 mm, 5 μm particle size) was used as a separation column. Mobile phase 2 consisting acetonitrile-triethylamine (0.5%) in phosphate buffer (pH 3.5; 20mM) (55:45, v/v) was used for the compound elution. The eluents were detected at 230 nm with photodiode array detector. An aliquot of 150 μl of plasma sample was introduced into the pretreatment column via the auto sampler using mobile phase 1 at a flow rate of 0.5 ml/min, column switching valve being positioned at A. The pretreatment column retained cetirizine, ambroxol and nebivolol (IS) in the column leaving the residual proteins of plasma eluted in void volume and drained out. The switching valve was shifted to position B at 7.5 min. Cetirizine, ambroxol and IS were eluted from the pretreatment column between 7. 5 and 11.5 min and introduced to the concentration column. Finally, cetirizine, ambroxol and IS were introduced to the separation column by switching valve using mobile phase 2 at a flow rate of 0.4 ml/min. During the analysis the pretreatment column was washed for the next analysis and resume to the position A. The total run time was 25 min for a sample. The procedure was repeated for urine analysis also. The method was linear from 2 to 450 ng/ml and 7-300 ng/ml for cetirizine and ambroxol respectively in plasma and 1-500 ng/ml and 5-400 ng/ml, respectively for cetirizine and ambroxol in urine. Intra-day and inter-day precision of cetirizine and ambroxol was below 15% in terms of coefficient of variation and accuracy of cetirizine and ambroxol was ranged from 94 to 101.6% and 91.1 to 100.2%, respectively. The method demonstrated high sensitivity and selectivity and therefore, applied to evaluate pharmacokinetics of cetirizine and ambroxol in healthy human volunteer after a single oral administration. Urine samples obtained from healthy human volunteers and clinical subjects with renal impairment have also been analyzed by the method to compare the elimination pattern. The method was precise and accurate for the estimation of cetirizine and ambroxol both in blood and in urine.  相似文献   

19.
A microtubule cross-bridging factor was isolated from erythrocytes of the toad, Bufo marinus. Erythrocytes were lysed and their cytoskeletons disassembled by sonication and high salt extraction. The solubilized proteins were recovered and fractionated using Sephadex G-200 column chromatography. The protein fractions from the column were analysed by SDS-PAGE and pooled into three groups: high molecular weight (HMW) proteins that eluted from the column in the void volume and had a protein composition that included HMW polypeptides; intermediate MW proteins that were shown by SDS-PAGE to contain polypeptides smaller than 120,000 D; and low MW (LMW) proteins that contained polypeptides smaller than 70,000 D. Each group was further fractionated by phosphocellulose (PC) chromatography. The flow-through was recovered, and bound proteins were then eluted by a step gradient of salt (0.2, 0.4, 0.6 and 0.8 M KCl). To assay for microtubule cross-bridging activity, column fractions were incubated with taxol-stabilized microtubules, formed from PC-purified brain tubulin (PC microtubules). Negatively stained samples were examined in the electron microscope for the reconstitution of microtubule bundles with interconnecting cross-bridges. The HMW protein fraction from the G-200 column contained the cross-bridging factor. When these proteins were further fractionated by PC chromatography only the fraction eluted by 0.2 M KCl induced the formation of microtubule bundles with cross-bridges. No other protein fraction isolated by the described method revealed cross-bridges between microtubules in vitro.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号