首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The HPLC/MS system, in which a monolithic silica capillary column is directly connected to an electronspray-ionization mass spectrometer, showed superior performance at high mobile phase linear velocity. A two-dimensional (2D) HPLC/MS system was established, using an ion-exchange particle-packed capillary column at the first dimension and a monolithic silica capillary column at the second dimension. In an analysis of tryptic fragments from bovine serum albumin, an 81% sequence coverage, obtained by the 2D-HPLC/MS system, increased by 23% as compared to a 1D-HPLC/MS system. This 2D-HPLC/MS system using a monolithic silica capillary column should be useful for enhancing sequence coverage of tryptic fragments in proteomics.  相似文献   

2.
Feng S  Pan C  Jiang X  Xu S  Zhou H  Ye M  Zou H 《Proteomics》2007,7(3):351-360
Immobilized metal affinity chromatography (IMAC) is a commonly used technique for phosphoproteome analysis due to its high affinity for adsorption of phosphopeptides. Miniaturization of IMAC column is essential for the analysis of a small amount of sample. Nanoscale IMAC column was prepared by chemical modification of silica monolith with iminodiacetic acid (IDA) followed by the immobilization of Fe3+ ion inside the capillary. It was demonstrated that Fe3+-IDA silica monolithic IMAC capillary column could specifically capture the phosphopeptides from tryptic digest of alpha-casein with analysis by MALDI-TOF MS. The silica monolithic IMAC capillary column was manually coupled with nanoflow RPLC/nanospray ESI mass spectrometer (muRPLC-nanoESI MS) for phosphoproteome analysis. The system was validated by analysis of standard phosphoproteins and then it was applied to the analysis of protein phosphorylation in mouse liver lysate. Besides MS/MS spectra, MS/MS/MS spectra were also collected for neutral loss peak. After database search and manual validation with conservative criteria, 29 singly phosphorylated peptides were identified by analyzing a tryptic digest of only 12 mug mouse liver lysate. The results demonstrated that the silica monolithic IMAC capillary column coupled with muRPLC-nanoESI MS was very suitable for the phosphoproteome analysis of minute sample.  相似文献   

3.
A comprehensive on-line sample clean-up with an integrated two-dimensional HPLC system was developed for the analysis of natural peptides. Samples comprised of endogenous peptides with molecular weights up to 20 kDa were generated from human hemofiltrate (HF) obtained from patients with chronic renal failure. The (poly-)peptides were separated using novel silica-based restricted access materials with strong cation-exchange functionalities (SCX-RAM). The size-selective sample fractionation step is followed by cation-exchange chromatography as the first dimension. The subsequent second dimension of separation is based on hydrophobic interaction using four parallel short reversed-phase (RP) columns implemented via a fully automated column switching technique. More than 1000 peaks were resolved within the total analysis time of 96 min. Substances of selected peaks were sampled to analyse their molecular weights by off-line MALDI-TOF mass spectrometry and to determine their amino acid sequence by Edman degradation. The potential for comprehensive peptide mapping and identification is demonstrated.  相似文献   

4.
Weak cation-exchange (WCX) and HILIC modes columns were prepared by on-column polymerization of acrylic acid on monolithic silica capillary columns modified with N-(3-triethoxysilylpropyl)methacrylamide anchor groups. The polymer-coated columns could be used for HILIC mode separation of pyridylamino (PA)-sugars and peptides including a tryptic digest of BSA, while for weak cation-exchange mode for the separation of proteins and nucleosides even at high linear velocity. The poly(acrylic acid) coated monolithic silica capillary columns showed greater retention toward PA-sugars than a polyacrylamide coated monolithic silica capillary columns prepared in the same manner. Proteins and nucleosides were separated effectively at pH 6.9 using the same column. The column provided fair permeability after the polymer-coating step. High-speed separation of proteins at u=4.66 mm/s with high efficiency was shown to be possible, while high-speed separation of nucleosides has achieved within one minute using the column at u=8.67 mm/s, suggesting that the column will be suitable for the second dimension separation of multidimensional HPLC systems.  相似文献   

5.
The HPLC/MS system, in which a monolithic silica capillary column is directly connected to an electronspray-ionization mass spectrometer, showed superior performance at high mobile phase linear velocity. A two-dimensional (2D) HPLC/MS system was established, using an ion-exchange particle-packed capillary column at the first dimension and a monolithic silica capillary column at the second dimension. In an analysis of tryptic fragments from bovine serum albumin, an 81% sequence coverage, obtained by the 2D-HPLC/MS system, increased by 23% as compared to a 1D-HPLC/MS system. This 2D-HPLC/MS system using a monolithic silica capillary column should be useful for enhancing sequence coverage of tryptic fragments in proteomics.  相似文献   

6.
We report a new design of a fully automated, high-efficiency parallel nonsplit nanoflow capillary HPLC system, coupled on-line with linear ion trap (LTQ) and high performance nanoelectrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (nanoESI LTQ-FTICR MS). The system, intended for high-throughput proteome analysis of complex protein mixtures, notably serum and plasma, consists of two reversed-phase trap columns for large volume sample injection with high speed sample loading and desalting and two reversed-phase analytical capillary columns. Through a nanoscale two-position, 10-port switching valve, the whole system is terminated by a 10 microm i.d. of nanoemitter mounted on the nanoelectrospray source in front of the sampling cone of the LTQ-FTICR MS. Gradient elution to both nanoflow-rate capillary columns is simultaneously delivered by a single HPLC system via two independent binary gradient pump systems. The parallel capillary column approach eliminates the time delays for column regeneration/equilibration since one capillary column is used for separating the sample mixtures and delivering the separated fractions to the MS, while the other capillary column is being regenerated and equilibrated. The reproducibility of retention time and peak intensity of the present automated parallel nanoflow-rate capillary HPLC system is comparable to that obtained using a single column configuration. Replicate injections of tryptic digests indicated that this system provided good reproducibility of retention time and peak area on both columns with average CV values of less than 1.08% and 7.04%, respectively. Throughput was increased to 100% for 2-h LC-MS analysis compared to the single capillary column LC-MS pipeline. Application of this system is demonstrated in a plasma proteomic study. A total of 312 868 MSMS events were acquired and 1564 proteins identified with high confidence (Protein Prophet > or = 0.9, and peptides matched > or = 2). Comparison of a series of plasma fractions run using the single-column LC-MS versus the parallel-column LC-MS demonstrated that parallel-column LC-MS system significantly reduced the sample carryover, improved MS data quality and increased the number of MS/MS sequence scan events.  相似文献   

7.
Zhou H  Xu S  Ye M  Feng S  Pan C  Jiang X  Li X  Han G  Fu Y  Zou H 《Journal of proteome research》2006,5(9):2431-2437
Phosphorylation is one of the most important post-translational modifications of proteins, which modulates a wide range of biological functions and activity of proteins. The analysis of phosphopeptides is still one of the most challenging tasks in proteomics research by mass spectrometry. In this study, a novel phosphopeptide enrichment approach based on the strong interaction of zirconium phosphonate (ZrP) modified surface with phosphopeptides has been developed. ZrP modified porous silicon (ZrP-pSi) wafer was prepared to specifically capture the phosphopeptides from complex peptide mixtures, and then the captured phosphopeptides were analyzed by MALDI-TOF MS by directly placing the wafer on a MALDI target. The phosphopeptide enrichment and MALDI analysis were both performed on the ZrP-pSi wafer which significantly reduced the sample loss and simplified the analytical procedures. The prepared ZrP-pSi wafer has been successfully applied for the enrichment of phosphopeptides from the tryptic digest of standard phosphoproteins beta-casein and alpha-casein. The excellent selectivity of this approach was demonstrated by analyzing phosphopeptides in the digest mixture of beta-casein and bovine serum albumin with molar ratio of 1:100. High detection sensitivity has been achieved for the analysis of the phosphopeptides from tryptic digestion of 2 fmol beta-casein on the ZrP-pSi surface.  相似文献   

8.
Due to the dynamic nature and low stoichiometry of protein phosphorylation, enrichment of phosphorylated peptides from proteolytic mixtures is often necessary prior to their characterization by mass spectrometry. Immobilized metal affinity chromatography (IMAC) is a popular way to enrich phosphopeptides; however, conventional IMAC lacks enough specificity for efficient phosphoproteome analysis. In this study, novel Fe 3O 4@TiO 2 microspheres with well-defined core-shell structure were prepared and developed for highly specific purification of phosphopeptides from complex peptide mixtures. The enrichment conditions were optimized using tryptic digests of beta-casein, and the high specificity of the Fe 3O 4@TiO 2 core-shell microspheres was demonstrated by effectively enriching phosphopeptides from the digest mixture of alpha-casein and beta-casein, as well as a five-protein mixture containing nonphosphoproteins (bovine serum albumin (BSA), myoglobin, cytochrome c) and phosphoproteins (ovalbumin and beta-casein). The Fe 3O 4@TiO 2 core-shell microspheres were further successfully applied for the nano-LC-MS/MS analysis of rat liver phosphoproteome, which resulted in identification of 56 phosphopeptides (65 phosphorylation sites) in mouse liver lysate in a single run, indicating the excellent performance of the Fe 3O 4@TiO 2 core-shell microspheres.  相似文献   

9.
BackgroundMonolithic chromatography using convective interaction media (CIM) disks or columns can be used in the separation step of speciation analysis. When different monolithic disks are placed in one housing, forming conjoint liquid chromatography (CLC) monolithic column, two-dimensional separation is achieved in a single chromatographic run.MethodsHere, we assembled low-pressure (maximum 50 bar) CLC monolithic column, which consists of two 0.34 mL shallow CIM monolithic disks and high-pressure CLC column (maximum 150 bar) from 0.1 mL analytical high performance short bed CIMac monolithic disks. Both the CLC columns constructed from affinity Protein G and weak anion exchange diethylamine (DEAE) disks, were applied for the speciation of cisplatin, oxaliplatin and carboplatin in spiked standard serum proteins, spiked human serum and serum of cancer patients. The analytical performances of the CLC columns used were evaluated by comparing their robustness, selectivity, repeatability and reproducibility. The separated serum proteins were detected on-line by ultraviolet (UV) and eluted Pt species by inductively coupled plasma mass spectrometry (ICP-MS). For accurate quantification of the separated Pt species (unbound Pt-based chemotherapeutic from species associated to transferrin (Tf), human serum albumin (HSA) and Immunoglobulin G (IgG)), post column isotope dilution (ID)-ICP-MS was used.ResultsThe data from analyses showed that both tested CLC monolithic columns gave statistically comparable results, with the low-pressure CLC column exhibiting better resolving power and robustness. It also enables more effective cleaning of monolithic disks and to analyse larger series of serum samples than the high-pressure CLC column. Analyses of serum samples of cancer patients treated with cisplatin or carboplatin showed that Pt-chemotherapeutics were bound preferentially to HSA (around 80%). The portion of unbound Pt in general did not exceed 2%, up to 5% of Pt was associated with Tf and approximately 20% with IgG. Column recoveries, calculated as a ratio between the sum of concentrations of Pt species eluted and concentration of total Pt in serum samples, were close to 100%.ConclusionsLow-pressure CLC column exhibited greater potential than high-pressure CLC column, and can be thus recommended for its intended use in speciation analysis of metal-based biomolecules.  相似文献   

10.
A methodology for the rapid and quantitative analysis of phosphorylation sites in proteins is presented. The coupling of capillary high-performance liquid chromatography (HPLC) to electrospray ionization mass spectrometry (ESI-MS) allowed one to distinguish phosphorylation sites based on retention time and mass difference from complex peptide mixtures. The methodology was first evaluated and validated for a mixture of non-, mono-, and dityrosine-phosphorylated synthetic peptides, corresponding to the tryptic fragment 485–496 (ALGADDSYYTAR) of the human protein tyrosine kinase ZAP-70. The limits of detection for the non-, mono- and diphosphorylated peptides were about 15, 40 and 100 fmol, respectively, when using a 300 μm I.D. column. Application of the method was extended to identify phosphopeptides generated from a trypsin digest of recombinant autophosphorylated ZAP-70, in particular with respect to quantifying the status at the regulatory phosphorylation sites Tyr-492 and Tyr-493. Combination of chromatographic and on-line tandem mass spectrometry data allowed one to ascertain the identity of the detected peptides, a prerequisite to analyses in more complex biological samples. As an extension to the methodology described above, we evaluated the feasibility of interfacing capillary HPLC to matrix assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI-TOF-MS), using a micromachined piezoelectric flow-through dispenser as the interface. This enabled direct arraying of chromatographically separated components onto a target plate that was precoated with matrix for subsequent analysis by MALDI-TOF-MS without further sample handling.  相似文献   

11.
Methods employing monolithic HPLC columns for the determination of the cyclooxygenase II inhibitors rofecoxib (I) and 3-isopropoxy-4-(4-methanesulfonylphenyl)-5,5'-dimethyl-5H-furan-2-one (DFP, III) in human plasma are described. Each analyte, together with an internal standard was extracted from the plasma matrix using solid-phase extraction in the 96-well format. The analytes were chromatographed on a Chromolith Speed Rod monolithic HPLC column (4.6 x 50 mm). Analyte detection for rofecoxib was via fluorescence following post-column photochemical derivatization. Detection for III was based on the native fluorescence of the compound. The precision, accuracy, and linearity of the methods were found to be comparable to those obtained using methods employing conventional packed HPLC columns. Use of the monolithic column permitted mobile phase flow-rates of up to 6.5 ml/min to be employed in the assays. The use of elevated flow-rates enabled the per sample analysis time to be reduced by up to a factor of 5 compared with assays based on packed HPLC columns. The results of experiments aimed at evaluating the ruggedness and reproducibility of monolithic columns employed in bioanalytical methods are presented.  相似文献   

12.
Pigment extracts from Emiliania huxleyi (Lohm.) Hay et Mohler (strains CCMP 370, CCMP 373, and NIOZ CH 24) were analyzed using high-performance liquid chromatography (HPLC) on highly efficient monomeric and polymeric octadecylsilica columns using either ammonium acetate or pyridine containing mobile phases. Both systems showed chromatographic profiles with peaks corresponding to pigments of uncertain structure: those of the polar and nonpolar chlorophyll c forms and one peak whose on-line diode array spectrum resembled that of the fucoxanthin acyloxy derivatives. Liquid chromatography coupled with atmospheric pressure chemical ionization mass spectrometry gave a molecular mass of 786 units for the unknown carotenoid. The pigments corresponding to each of these fractions were isolated and their visible spectra recorded in various solvents. Samples of the isolated pigments were subjected to analysis by fast atom bombardment mass spectrometry that confirmed a molecular mass of 786 for the unknown carotenoid and gave a mass of 654 units for the polar chlorophyll c 3, compatible with the monovinylic structure previously suggested. The detection of these new pigments calls for attention on the use of correct methodologies when HPLC pigment signatures are used to study the taxonomic composition of natural phytoplankton populations.  相似文献   

13.
In this work, monolithic columns were used as a fast separation tool for multiple-component quantitative liquid chromatography-tandem mass spectrometry (LC-MS-MS) assays of drug candidates in biological fluids. A considerably reduced runtime was achieved while maintaining good chromatographic separations. This significantly improved separation speed demanded higher throughput on sample extraction. To this end, monolithic separations were coupled on-line with high-flow extraction, which allowed for the fast extraction and separation of samples containing multiple analytes. An evaluation of this system was performed using a mixture of fenfluramine, temazepam, oxazepam, and tamoxifen in plasma. A total cycle time of 1.2 min was achieved which included both sample extraction and subsequent monolithic column separation via column switching. A total of over 400 plasma samples were analyzed in less than 10 h. The sensitivity and responses were reproducible throughout the run. The system has been routinely used in the authors' laboratory for high-throughput quantitation of compounds in biological fluids in support of drug discovery programs. The assay for samples from a 9-in-1 dog pharmacokinetic study is shown as an example to demonstrate the capability of this system.  相似文献   

14.
A new fast method for identification and characterization of proteolytic digests of proteins by monolithic liquid chromatography coupled with mass spectrometry has been developed. The advantages of the monolithic columns are a high-pressure stability and low back pressure resulting in higher flow rates for capillary or nanosize columns simplifying the system handling. As was shown in several publications, such monolithic stationary phases are highly qualified for the analysis of peptides and proteins, but so far, only small volumes could be injected into the system, which might hamper the sample preparation leading to protein precipitation and partial loss of sample. To overcome the problem of small injection volumes, we established a system including a short monolithic trap column to allow preconcentration of the peptides. The injected sample is flushed at higher flow rates onto the trap column, bound to the stationary phase, and in this way concentrated in a few nanoliters before starting the separation. The expanded system was optimized and tested using different reference protein samples. Eluting peptides were detected by MALDI-TOF/TOF-MS and identified by database searching. The system is now a permanent part for proteome analysis in our lab, and as such, it was successfully applied for the detection of post-translational modifications and the analysis of membrane proteins. One example for these analyses is also included in this paper.  相似文献   

15.
Peptides, proteins, single-stranded oligonucleotides, and double-stranded DNA fragments were separated with high resolution in micropellicular, monolithic capillary columns prepared by in situ radical copolymerization of styrene and divinylbenzene. Miniaturized chromatography both in the reversed-phase and the ion-pair reversed-phase mode could be realized in the same capillary column because of the nonpolar character of the poly-(styrene/divinylbenzene) stationary phase. The high chromatographic performance of the monolithic stationary phase facilitated the generation of peak capacities for the biopolymers in the range of 50-140 within 10 min under gradient elution conditions. Employing volatile mobile phase components, separations in the two chromatographic separation modes were on-line hyphenated to electrospray ionization (tandem) mass spectrometry, which yielded intact accurate molecular masses as well as sequence information derived from collision-induced fragmentation. The inaccuracy of mass determination in a quadrupole ion trap mass spectrometer was in the range of 0.01-0.02% for proteins up to a molecular mass of 20000, and 0.02-0.12% for DNA fragments up to a molecular mass of 310000. High-performance liquid chromatography-electrospray ionization mass spectrometry utilizing monolithic capillary columns was applied to the identification of proteins by peptide mass fingerprinting, tandem mass spectrometric sequencing, or intact molecular mass determination, as well as to the accurate sizing of double-stranded DNA fragments ranging in size from 50 to 500 base pairs, and to the detection of sequence variations in DNA fragments amplified by the polymerase chain reaction.  相似文献   

16.
We report here on the preparation of monolithic capillary columns in view to their integration in a microsystem for on-chip sample preparation before their on-line analysis by electrospray and mass spectrometry (ESI-MS). These monolithic columns are based on polymer materials and consist of reverse phases for peptide separation and/or desalting. They were prepared using lauryl methacrylate (LMA), ethylene dimethacrylate (EDMA) as well as a suitable porogenic mixture composed of cyclohexanol and ethylene glycol. The resulting stationary phases present thus a C12-functionality. The LMA-based columns were first prepared in a capillary format using capillary tubing of 75 microm i.d. and tested in nanoLC-MS experiments for the separation of a commercial Cytochrome C digest composed of 12 peptidic fragments whose isoelectric point values and hydrophobic character cover a wide range. The LMA-based columns were capable of separating the peptidic fragments and their performances were seen to be similar as those of standard commercial columns dedicated to proteomic purposes with calculated separation efficiencies up to 145 x 10(3) plates/m. Monolithic LMA-based phases were then successfully polymerized in microchannels fabricated using the negative photoresist SU-8. After the polymerization, the systems were seen to withstand the pressures applied during the nanoLC-MS separation tests that were carried out in the same conditions as for the monolithic capillary columns. The pressure drop during these tests of the in-microchannel monoliths was as high as 50 bar; however, the separation was not as good as for a capillary format which could be accounted for by the monolith dimensions.  相似文献   

17.
C-terminal labelling of beta-casein   总被引:1,自引:0,他引:1  
This paper is the first to report specific labelling of a native protein at its C-terminal end by carboxypeptidase Y-catalyzed transpeptidation between beta-casein and tritiated Phe amide. A tryptic digest of the radiolabelled protein was resolved by reversed-phase HPLC and a single labelled peptide was isolated therefrom. Sequence determination and FAB mass spectrometry showed that the last 2 residues (Val-209, Ile-208) of beta-casein had been deleted and Ile 207 substituted by Phe, deamidation presumably occurring after transpeptidation. Identical results were obtained by transpeptidating the isolated C-terminal tryptic heptapeptide (203-209) of native beta-casein.  相似文献   

18.
A system which consisted of multidimensional liquid chromatography (Yin-yang MDLC) coupled with mass spectrometry was used for the identification of peptides and phosphopeptides. The multidimensional liquid chromatography combines the strong-cation exchange (SCX), strong-anion exchange (SAX), and reverse-phase methods for the separation. Protein digests were first loaded on an SCX column. The flow-through peptides from SCX were collected and further loaded on an SAX column. Both columns were eluted by offline pH steps, and the collected fractions were identified by reverse-phase liquid chromatography tandem mass spectrometry. Comprehensive peptide identification was achieved by the Yin-yang MDLC-MS/MS for a 1 mg mouse liver. In total, 14 105 unique peptides were identified with high confidence, including 13 256 unmodified peptides and 849 phosphopeptides with 809 phosphorylated sites. The SCX and SAX in the Yin-Yang system displayed complementary features of binding and separation for peptides. When coupled with reverse-phase liquid chromatography mass spectrometry, the SAX-based method can detect more extremely acidic (pI < 4.0) and phosphorylated peptides, while the SCX-based method detects more relatively basic peptides (pI > 4.0). In total, 134 groups of phosphorylated peptide isoforms were obtained, with common peptide sequences but different phosphorylated states. This unbiased profiling of protein expression and phosphorylation provides a powerful approach to probe protein dynamics, without using any prefractionation and chemical derivation.  相似文献   

19.
The mass spectrometric analysis of protein phosphorylation is still far from being routine, and the outcomes thereof are often unsatisfying. Apart from the inherent problem of substoichiometric phosphorylation, three arguments as to why phosphorylation analysis is so problematic are often quoted, including (a) increased hydrophilicity of the phosphopeptide with a concomitant loss during the loading onto reversed-phase columns, (b) selective suppression of the ionization of phosphopeptides in the presence of unmodified peptides, and (c) lower ionization/detection efficiencies of phosphopeptides as compared with their unmodified cognates. Here we present the results of a study investigating the validity of these three arguments when using electrospray ionization mass spectrometry. We utilized a set of synthetic peptide/phosphopeptide pairs that were quantitated by amino acid analysis. Under the applied conditions none of the experiments performed supports the notions of (a) generally increased risks of losing phosphopeptides during the loading onto the reversed-phase column because of decreased retention and (b) the selective ionization suppression of phosphopeptides. The issue of ionization/detection efficiencies of phosphopeptides versus their unphosphorylated cognates proved to be less straightforward when using electrospray ionization because no evidence for decreased ionization/detection efficiencies for phosphopeptides could be found.  相似文献   

20.
A novel open tubular nanoproteomic platform featuring accelerated on-line protein digestion and high-resolution nano liquid chromatography mass spectrometry (LC-MS) has been developed. The platform features very narrow open tubular columns, and is hence particularly suited for limited sample amounts. For enzymatic digestion of proteins, samples are passed through a 20 µm inner diameter (ID) trypsin + endoproteinase Lys-C immobilized open tubular enzyme reactor (OTER). Resulting peptides are subsequently trapped on a monolithic pre-column and transferred on-line to a 10 µm ID porous layer open tubular (PLOT) liquid chromatography LC separation column. Wnt/ß-catenein signaling pathway (Wnt-pathway) proteins of potentially diagnostic value were digested+detected in targeted-MS/MS mode in small cell samples and tumor tissues within 120 minutes. For example, a potential biomarker Axin1 was identifiable in just 10 ng of sample (protein extract of ∼1,000 HCT15 colon cancer cells). In comprehensive mode, the current OTER-PLOT set-up could be used to identify approximately 1500 proteins in HCT15 cells using a relatively short digestion+detection cycle (240 minutes), outperforming previously reported on-line digestion/separation systems. The platform is fully automated utilizing common commercial instrumentation and parts, while the reactor and columns are simple to produce and have low carry-over. These initial results point to automated solutions for fast and very sensitive MS based proteomics, especially for samples of limited size.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号