首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Effects of Reusing Baseline Volumes of Interest by Applying (Non-)Rigid Image Registration on Positron Emission Tomography Response Assessments
Authors:Floris H P van Velden  Ida A Nissen  Wendy Hayes  Linda M Velasquez  Otto S Hoekstra  Ronald Boellaard
Institution:1. Department of Radiology & Nuclear Medicine, VU University Medical Center, Amsterdam, Noord-Holland, The Netherlands.; 2. Exploratory Clinical and Translational Research, Bristol-Myers Squibb, Princeton, New Jersey, United States of America.; NIH, United States of America,
Abstract:

Objectives

Reusing baseline volumes of interest (VOI) by applying non-rigid and to some extent (local) rigid image registration showed good test-retest variability similar to delineating VOI on both scans individually. The aim of the present study was to compare response assessments and classifications based on various types of image registration with those based on (semi)-automatic tumour delineation.

Methods

Baseline (n = 13), early (n = 12) and late (n = 9) response (after one and three cycles of treatment, respectively) whole body 18F]fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (PET/CT) scans were acquired in subjects with advanced gastrointestinal malignancies. Lesions were identified for early and late response scans. VOI were drawn independently on all scans using an adaptive 50% threshold method (A50). In addition, various types of (non-)rigid image registration were applied to PET and/or CT images, after which baseline VOI were projected onto response scans. Response was classified using PET Response Criteria in Solid Tumors for maximum standardized uptake value (SUVmax), average SUV (SUVmean), peak SUV (SUVpeak), metabolically active tumour volume (MATV), total lesion glycolysis (TLG) and the area under a cumulative SUV-volume histogram curve (AUC).

Results

Non-rigid PET-based registration and non-rigid CT-based registration followed by non-rigid PET-based registration (CTPET) did not show differences in response classifications compared to A50 for SUVmax and SUVpeak,, however, differences were observed for MATV, SUVmean, TLG and AUC. For the latter, these registrations demonstrated a poorer performance for small lung lesions (<2.8 ml), whereas A50 showed a poorer performance when another area with high uptake was close to the target lesion. All methods were affected by lesions with very heterogeneous tracer uptake.

Conclusions

Non-rigid PET- and CTPET-based image registrations may be used to classify response based on SUVmax and SUVpeak. For other quantitative measures future studies should assess which method is valid for response evaluations by correlating with survival data.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号