首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Determination of perospirone by liquid chromatography/electrospray mass spectrometry: application to a pharmacokinetic study in healthy Chinese volunteers
Authors:Ma Ning  Liu Wen-Ying  Li Huan-De  Zhu Yun-Gui  Zhang Bi-Kui  Wang Feng  Zhu Rong-Hua  Xiang Da-Xiong
Institution:Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, Department of Pharmaceutical Analysis, China Pharmaceutical University, Nanjing 210009, PR China.
Abstract:Perospirone is a novel atypical antipsychotic with a unique combination of 5-HT(1A) receptor agonism as well as 5-HT(2A) and D(2) receptor antagonism. A simple rapid and selective LC-MS method utilizing a single quadrupole mass spectrometer was developed and validated for the determination of perospirone hydrochloride in human plasma. N-hexane was used to extract perospirone hydrochloride and amlodipine benzenesulfonate (internal standard (IS)) from an alkaline plasma sample. LC separation was performed on a XTerra MS C(18) column (100mmx2.1mm, i.d. 3.5microm) using methanol -10mM ammonium acetate (84:16, v/v) as a mobile phase. The quantification of target compounds was obtained by using a selected ion monitoring (SIM) at m/z 427.5 M+H](+) for perospirone hydrochloride, and at m/z 431.4 M+Na](+) for IS (amlodipine benzenesulfonate). Perospirone and IS eluted as sharp, symmetrical peaks with retention times of 3.11+/-0.01min and 4.15+/-0.2min, respectively. Calibration curves of perospirone hydrochloride in human plasma at concentrations ranging from 0.10 to 21.1ng/mL exhibited excellent linearity (r(2)=0.9997). The mean absolute recovery of the drug from plasma was more than 85%. Intra- and inter-day relative standard deviations were less than 6.43% and 11.9% for perospirone hydrochloride at the range from 0.32 to 10.6ng/mL. Stability characteristics of the drug-containing plasma were thoroughly evaluated to establish appropriate conditions to process, store and prepare for chromatographic analysis without inducing significant chemical degradation. The following pharmacokinetic parameters were elucidated after administering a single dose of 8mg perospirone hydrochloride. The area under the plasma concentration versus time curve from time 0 to 24h (AUC(0-24)) was 15.48+/-4.23microg/Lh; peak plasma concentration (C(max)) was 2.79+/-0.78microg/L; time to C(max) (T(max)) was 1.79+/-0.45h; and elimination half-life (t(1/2)) 6.78+/-1.38h. The described assay method showed acceptable precision, accuracy, linearity, stability, and specificity and can be used for pharmacokinetic studies, therapeutic drug monitoring, and drug abuse screening.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号