首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Development of fast Fourier transformation continuous cyclic voltammetry as a highly sensitive detection system for ultra trace monitoring of penicillin V
Authors:Norouzi Parviz  Ganjali Mohammad Reza  Daneshgar Parandis  Alizadeh Taher  Mohammadi Ali
Institution:Center of Excellence in Electrochemistry, Faculty of Chemistry, University of Tehran, Tehran, Iran. norouzi@khayam.ut.ac.ir
Abstract:Fast continuous cyclic voltammetry was used as a detection method for penicillin V in a flow injection system. Additionally, a special computer-based numerical calculation method (using fast Fourier transformation) providing enhancement of the analyte signal and noise reduction is introduced here. During the measurements, the potential waveform (consisting of the potential steps of cleaning, stripping, and the potential ramp) was continuously applied to an Au disk microelectrode (12.5 microm in radius). In particular, the effects of accumulation potential, sweep rate, and delay time on the sensitivity and selectivity of the method were investigated. Eventually, the stripping time was found to be less than 300 ms, the detection limit of the method was 7.0x10(-12) M, and the associated relative standard deviation at 5.0x10(-6) M penicillin V was 2.3 for eight runs.
Keywords:Penicillin V  Continuous cyclic voltammetry  Flow injection  Ultramicroelectrode
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号