首页 | 本学科首页   官方微博 | 高级检索  
     


Valid and reliable instruments for arm-hand assessment at ICF activity level in persons with hemiplegia: a systematic review
Authors:Ryanne JM Lemmens  Annick AA Timmermans  Yvonne JM Janssen-Potten  Rob JEM Smeets  Henk AM Seelen
Affiliation:1. Research School CAPHRI, Department of Rehabilitation Medicine, Maastricht University, Maastricht, the Netherlands
2. Adelante, Centre of Expertise in Rehabilitation and Audiology, Hoensbroek, the Netherlands
3. Department of Rehabilitation Medicine, Maastricht University Medical Centre, Maastricht, the Netherlands
Abstract:

Background

Loss of arm-hand performance due to a hemiparesis as a result of stroke or cerebral palsy (CP), leads to large problems in daily life of these patients. Assessment of arm-hand performance is important in both clinical practice and research. To gain more insight in e.g. effectiveness of common therapies for different patient populations with similar clinical characteristics, consensus regarding the choice and use of outcome measures is paramount. To guide this choice, an overview of available instruments is necessary. The aim of this systematic review is to identify, evaluate and categorize instruments, reported to be valid and reliable, assessing arm-hand performance at the ICF activity level in patients with stroke or cerebral palsy.

Methods

A systematic literature search was performed to identify articles containing instruments assessing arm-hand skilled performance in patients with stroke or cerebral palsy. Instruments were identified and divided into the categories capacity, perceived performance and actual performance. A second search was performed to obtain information on their content and psychometrics.

Results

Regarding capacity, perceived performance and actual performance, 18, 9 and 3 instruments were included respectively. Only 3 of all included instruments were used and tested in both patient populations. The content of the instruments differed widely regarding the ICF levels measured, assessment of the amount of use versus the quality of use, the inclusion of unimanual and/or bimanual tasks and the inclusion of basic and/or extended tasks.

Conclusions

Although many instruments assess capacity and perceived performance, a dearth exists of instruments assessing actual performance. In addition, instruments appropriate for more than one patient population are sparse. For actual performance, new instruments have to be developed, with specific focus on the usability in different patient populations and the assessment of quality of use as well as amount of use. Also, consensus about the choice and use of instruments within and across populations is needed.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号