首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Flow‐injection chemiluminescence determination of gentamicin: optimization by central composite design
Authors:M Iranifam  A Hasanzadeh  M Fathinia  A R Khataee  S A Mousavi
Institution:1. Department of Chemistry, Faculty of Science, University of Maragheh, Maragheh, East Azerbaijan, Iran;2. Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran;3. Sama Technical and Vocational Training College, Azad University, Mamaghan Branch, Mamaghan, East Azerbaijan, Iran
Abstract:A simple and sensitive flow‐injection chemiluminescence (CL) method has been developed for the determination of gentamicin sulfate. The method is based on the inhibitory effect of gentamicin on the CL emission accompanying oxidation of luminol by H2O2 in an alkaline medium in the presence of Cu(II) as a catalyst. Inhibition was caused by the formation of a strong complex between analyte and the catalyst. Experimental variables, including the concentrations of luminol (µmol/L), H2O2 (mol/L), Cu(II) (mol/L) and NaOH (mol/L), were optimized using a central composite design. Under optimum conditions, the plot of CL intensity versus gentamicin concentration was found to have two linear ranges. One range was at low concentrations from 1.0 to 10.0 mg/L and the other was from 10.0 to 30.0 mg/L. Precision was calculated by analyzing samples containing 5.0 mg/L gentamicin (n = 11) and the relative standard deviation (RSD) was 1.7%. Also, a high injection throughput of 120 samples/h was achieved. This method was successfully applied to the determination of gentamicin sulfate in pharmaceutical formulations and water samples. Copyright © 2013 John Wiley & Sons, Ltd.
Keywords:flow‐injection  chemiluminescence  gentamicin  pharmaceuticals  response surface methodology
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号